• 제목/요약/키워드: Separation failure

검색결과 165건 처리시간 0.027초

CFRP 판으로 전단 보강된 이후 동결융해에 노출된 철근콘크리트 보의 보강성능 및 파괴특성 (Strengthening Performance and Failure Characteristics of Reinforced Concrete Beams Exposed to Freezing-and-thawing Cycles after Shear Strengthening with CFRP Plate)

  • 윤현도;김선우;전에스더;이민정
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.457-460
    • /
    • 2008
  • CFRP plates has been established as an effective method for rehabilitation and strengthening of concrete structures. The CFRP reinforcements are bonded to beams and slabs using structural adhesives. Adhesive strength can be affected by environmental exposure. During freezing-and-thawing cycling, temperature-induced stresses in the adhesive layer, due to differential thermal expansion between the CFRP and the substrate concrete, may lead to bond damage and contribute to or cause premature CFRP composite separation. This paper presents the results of experimental program undertaken to investigate the effects of freeze-thaw cycling (from -18 to $4^{\circ}C$) on the behavior and failure characteristics of RC beams strengthened in shear with CFRP plate using acoustic emission (AE) technique.

  • PDF

The medical management of mitral stenosis in a Bull Terrier

  • Kun Ho Song;Aleksandra Domanjko Petric
    • 한국동물위생학회지
    • /
    • 제46권1호
    • /
    • pp.75-79
    • /
    • 2023
  • An eight-year-old, 28-kg male bull terrier who showed signs of lethargy and cough was referred for further evaluation of congestive heart failure. On presentation, physical examination revealed a systolic murmur at the left apex of the heart. Moreover, chest radiograph evaluation confirmed the mild alveolar and interstitial patterns in the caudal lung lobes and a grossly enlarged left atrium and left ventricle. Electrocardiography showed atrial fibrillation with a wide QRS complex, and transthoracic echocardiography revealed marked enlargement of the left atrium with abnormal morphology of the mitral valve. The thickened, hammer-like appearance and abnormal diastolic motion of the mitral valve leaflets were characterized by decreased leaflet separation and doming of the valve. The diagnosis was mitral stenosis with congestive heart failure and atrial fibrillation. The owner declined interventional valvuloplasty. Medical treatment included furosemide, pimobendan and diltiazem. Regular health check-ups have shown that vitality and clinical signs have improved considerably, and the dog have remained stable for 6 months after the presentation.

강판으로 휨 보강된 철근콘크리트 보의 조기파괴하중 산정 (Premature Failure Load of Reinforced Concrete Beams with Flexural Strengthened by Steel Plates)

  • 김행준;김우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.283-292
    • /
    • 2005
  • 강판으로 부분 보강된 철근콘크리트 보의 조기파괴하중을 추정하기 위하여 변수연구를 수행하였다. 설계변수는 전단철근의 유무, 비보강길이의 비, 인장철근에 대한 보강 강판의 철근비, 전단지간 대 보강된 보의 유효깊이 비로 하였다. 유한요소해석 결과, 강판으로 부분 보강된 철근콘크리트 보의 조기파괴를 지배하는 1차 적인 요인은 비보강길이이지만 보강철근비, 전단지간 대 유효깊이의 비 등도 영향을 주는 것으로 나타났다. 설계변수의 조합작용을 고려한 근사식을 기존의 실험결과와 비교한 결과 거의 일치하였다.

복합재료 스킨-보강재 접합 시편의 파손 특성에 대한 시험 연구 (Experimental Debonding Failure Behaviors of Composite Skin-Stiffener Bonded Specimens)

  • 김광수;안재모;장영순;이영무
    • Composites Research
    • /
    • 제20권6호
    • /
    • pp.8-14
    • /
    • 2007
  • 스킨-보강재 시편 시험을 통해 스킨과 보강재의 분리 파손 특성을 살펴보고 접합방법, 보강재 단면 및 이차 접합 파라미터의 영향을 조사하였다. 본 시험 결과와 이전 시험[1]의 결과를 종합해 볼 때, 보강패널의 스킨-보강재 분리 파손 강도를 판단하는 기준으로 스킨-보강재 시편의 파손 변위를 이용하는 것이 타당하며 동일한 접합 방법을 사용할 경우, closed형 보다 open형 보강재를 사용하는 것이 복합재 보강 패널에서 스킨과 보강재의 분리파손을 방지하는데 유리함을 알 수 있었다. 접합방법으로는 이차접합 및 접착제를 사용한 동시성형이 좋은 파손 강도를 보였으며 접착제 없는 동시성형이 가장 나쁜 파손 강도를 나타내었다. 파손 모드는 이차접합 시편은 주로 계면 파손이 발생하였으며 동시성형 시편은 복합재료의 층간분리 파손이 발생하였다. 이차 접합 시편에서는 접착제 두께가 작을수록 높은 파손 강도를 보였다. Fillet은 시편의 강도에 영향을 미치지 않았다. 표면 조도의 영향은 open형 및 closed형 시편이 다르게 나타났다.

인공 가속열화에 따른 차동식 스포트형 열감지기의 고장 원인분석 (Failure Analysis of the Rate of Rise Spot Type Heat Detector on Artificially Accelerated Aging)

  • 김찬영
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.48-55
    • /
    • 2011
  • 차동식 스포트형 공기 팽창식 열감지기를 인공 가속열화 시켰을 때 발생하는 고장 원인에 대하여 분석하였다. 감지기에 고장이 발생하는 원인은 감열실 금속을 고정하는 접합재(binder)가 플라스틱 몰딩(moulding)에서 분리되어 발생하는 고장과, 감열실 금속과 다이어프램 금속을 고정하는 플라스틱 몰딩에 균열이 발생되는 고장으로 확인되었다. 고장이 발생하지 않은 감지기는 감열실 금속 및 다이어프램 금속이 플라스틱 몰딩에 접합재로 완전히 부착되어 있었다. 또한 2010G 감지기는 접합재의 기계적 강도를 향상시키기 위하여 접합재에 유리강화섬유가 추가되었음이 확인되었다. 감지기 종류별에 따른 플라스틱과 접합재의 밀도에는 큰 차이가 없었다. 그러나 감지기의 플라스틱에 대한 열중량분석(TGA) 결과, 제작년도는 같지만 제조회사가 다른 2005A와 2005B의 플라스틱 열적특성이 동일하지 않은 것으로 확인되었다.

Influence of interfacial adhesive on the failure mechanisms of truss core sandwich panels under in-plane compression

  • Zarei, Mohammad J.;Hatami, Shahabeddin;Gholami, Mohammad
    • Steel and Composite Structures
    • /
    • 제44권4호
    • /
    • pp.519-529
    • /
    • 2022
  • Sandwich structures with the superior mechanical properties such as high stiffness and strength-to-weight ratio, good thermal insulation, and high energy absorption capacity are used today in aerospace, automotive, marine, and civil engineering industries. These structures are composed of moderately stiff, thin face sheets that withstand the majority of transverse and in-plane loads, separated by a thick, lightweight core that resists shear forces. In this research, the finite element technique is used to simulate a sandwich panel with a truss core under axial compressive stress using ABAQUS software. A review of past experimental studies shows that the bondline between the core and face sheets plays a vital role in the critical failure load. Therefore, this modeling analyzes the damage initiation modes and debonding between face sheet and core by cohesive surface contact with traction-separation model. According to the results obtained from the modeling, it can be observed that the adhesive stiffness has a significant influence on the critical failure load of the specimens. To achieve the full strength of the structure as a continuum, a lower limit is obtained for the adhesive stiffness. By providing this limit stiffness between the core and the panel face sheets, sudden failure of the structure can be prevented.

장기 보관된 분리장치의 성능 및 노화에 관한 연구 (Study of Aging and Performance About Separation Devices Has Been Stored)

  • 김동성;진홍식
    • 한국항공우주학회지
    • /
    • 제49권7호
    • /
    • pp.565-572
    • /
    • 2021
  • 본 연구에서는 국방 분야에서 분리장치로 사용되고 있는 파이로 장치 중 장기간 보관된 폭발볼트의 성능 및 노화에 관한 연구를 수행하였다. 연구를 위해 약 10년간 무기체계에 탑재되어 있던 폭발볼트를 확보하였으며, AIAA Standard 및 MIL-STD를 기반으로 성능 및 수명 평가 절차를 수립하였다. 성능 평가를 위해 먼저 비기능 검사를 수행하여 외적인 변화나 고장이 발생하였는지 확인하였으며, 내부 회로 및 구조에 이상이 없는지 회로검사와 X-ray 검사를 수행하였다. 비기능 검사가 통과된 시료에 대해서 작동 확인을 위한 성능 시험을 실시하였다. 성능 시험을 통해 폭발볼트의 분리 여부 및 분리시간을 측정하였으며, 일부 시료의 경우 잔여 수명 및 연장 가능성을 확인하기 위해 고온저장시험 후 성능 시험을 실시하였다. 마지막으로 시험 결과와 아레니우스 모델을 바탕으로 잔여 수명 및 신뢰도를 예측하였으며, 수명에 따른 신뢰도를 확인하였다.

Fatigue life prediction for radial truck tires using a global-local finite element method

  • Jeong, Kyoung Moon;Beom, Hyeon Gyu;Kim, Kee-Woon;Cho, Jin-Rae
    • Interaction and multiscale mechanics
    • /
    • 제4권1호
    • /
    • pp.35-47
    • /
    • 2011
  • A global-local finite element modeling technique is employed in this paper to predict the fatigue life of radial truck tires. This paper assumes that a flaw exists inside the tire, in the local model. The local model uses an FEM fracture analysis in conjunction with a global-local technique in ABAQUS. A 3D finite element local model calculates the energy release rate at the belt edge. Using the analysis of the local model, a study of the energy release rate is performed in the crack region and used to determine the crack growth rate analysis. The result considers how different driving conditions contribute to the detrimental effects of belt separation in truck tire failure. The calculation of the total mileage on four sizes of radial truck tires has performed on the belt edge separation. The effect of the change of belt width design on the fatigue lifetime of tire belt separation is discussed.

MDF를 이용한 알루미늄 평판 절개 해석 (Numerical Analysis of MDF for Aluminum Plate Cutting)

  • 이주호
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.134-141
    • /
    • 2018
  • 본 연구에서는 MDF(Mild-detonating Fuse)를 이용한 선형분리장치 개발 가능성을 확인하기 위해 기초 연구를 수행하였다. 지름이 작은 금속(납) 튜브 내부에 화약(RDX)이 충전되어 있는 MDF를 활용한 알루미늄 평판 절개 기초 시험을 수행하였다. 평판의 두께와 MDF의 단위 길이당 화약량을 조절해가며 시험을 수행하였으며, 평판 두께와 화약량에 따른 절개 여부를 확인하였다. 시험 결과를 바탕으로 AUTODYN 기반의 수치 해석 모델을 개발하였으며, 정확한 파괴 조건을 결정하였다. 시험 및 해석 결과 분석을 통해 MDF의 알루미늄 평판 절개 메커니즘과 특성을 확인하였으며, 체계 적용 가능성을 확인하였다. 개발된 해석 기법을 활용하면 다양한 MDF 및 구조물에 대한 절개 가능 여부를 미리 확인하여 개발 과정에서의 시험 비용을 최소화 할 수 있다.

부하-강도 분석을 이용한 격막형 펄스분리장치의 내열강도에 대한 신뢰성 예측 사례연구 (Case Study on Reliability Prediction of Barrier Type Pulse Separation Device using Stress-Strength Analysis)

  • 이동원;정세용;이방업;정규동;박부희;안동근;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권2호
    • /
    • pp.124-130
    • /
    • 2015
  • A stress-strength analysis is used to assess the reliability of a multi-pulse rocket motor system. Main stress is found to be thermal during explosion and the distribution is obtained by simulation. The strength distribution is derived from the results of actual specimen tests. The failure rate of barrier type pulse separation device is estimated.