• Title/Summary/Keyword: Separation control

Search Result 1,030, Processing Time 0.033 seconds

A Study on Database Access Control using Least-Privilege Account Separation Model (최소 권한 계정 분리 모델을 이용한 데이터베이스 엑세스 제어 연구)

  • Jang, Youngsu
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.3
    • /
    • pp.101-109
    • /
    • 2019
  • In addition to enabling access, database accounts play a protective role by defending the database from external attacks. However, because only a single account is used in the database, the account becomes the subject of vulnerability attacks. This common practice is due to the lack of database support, large numbers of users, and row-based database permissions. Therefore if the logic of the application is wrong or vulnerable, there is a risk of exposing the entire database. In this paper, we propose a Least-Privilege Account Separation Model (LPASM) that serves as an information guardian to protect the database from attacks. We separate database accounts depending on the role of application services. This model can protect the database from malicious attacks and prevent damage caused by privilege escalation by an attacker. We classify the account control policies into four categories and propose detailed roles and operating plans for each account.

FLOW CONTROL ON ELLIPTIC AIRFOILS USING SYNTHETIC JET (합성제트를 이용한 타원형 익형 유동제어)

  • Kim, S.H.;Kim, C.W.
    • Journal of computational fluids engineering
    • /
    • v.15 no.4
    • /
    • pp.46-52
    • /
    • 2010
  • In the present work, the aerodynamic characteristics of elliptic airfoils which have a 12% thickness ratio are numerically investigated based on Reynolds-averaged Navier-Stokes equations and a transition SST model at a Reynolds number 8.0$\times$105. The numerical simulation of a synthetic jet actuator which is a well-known zero-net-mass active flow control actuator located at x/c = 0.00025, was performed to control massive flow separation around the leading edge of the elliptic airfoils. Four cases of non-dimensional frequencies were simulated at an angle of attack of 12 degree. It is found that the size of the vortex induced by synthetic jets was getting smaller as the jet frequency becomes higher. Comparison of the location of synthetic jets between x/c = 0.00025 (around the leading edge) and x/c = 0.9 (near the separation) shows that the control near the leading edge induces closed recirculation flow regions caused by the interaction of the synthetic jet with the external flow, but the control applied at 0.9c (near the trailing edge) induces a very small and weak vortex which quickly decays due to weak intensity.

Pollutant Control using the Separation Wall between Stormwater and Sewage in a Combined Sewer System (우오수분리벽을 이용한 합류식 하수관거의 오염물질 제어효과)

  • Lee, Kuang Chun;Choi, Bong Choel;Lim, Bong Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.461-469
    • /
    • 2004
  • This research is to determine the stormwater effects on sewer concentrations by measuring and comparing the flow and pollutant concentrations during dry and rainy periods in the existing BOX type combined sewer pipes. The monitoring was carried out in two sites, which are the Daesachen outfall having PE separation wall in BOX type combined sewer pipes and the Yongunchen outfall not having seperatioin wall. The average flow-weighted BOD concentraion in Yongunchen outfall is 2-fold lower than in Daesachen outfall because of the dilution effect from ravine water. However, the pollutant mass loading is 16 fold higher in Yongunchen outfall than in Daesachen outfall because of more flows. According to the research, the separation wall controls 52% pollutant mass during a storm period (11.5 mm/hr rainfall intensity). Therefore, the Yongunchen combined sewer system (CSS) need separation wall to control and to prevent more pollutant input in stream. In Daesachen area, the maximum sewer flow rate during a storm period measured about 10 fold bigger than average sewer flow during dry periods. Also the concentrations between rainy and dry periods increase approximately 33 fold for BOD and 120 fold for SS. In Yongunchen area, it increases about 9 fold for the maximum flow rate, 18 fold for BOD and 22 fold for SS during a storm. Therefore, the research is concluded that the separation wall between stromwater (or ravine water) and sewage can decrease the dilution effect in CSS and control the pollutant loading.

A PIV Study of Flow Patterns Over Stationary and Pitch-Oscillating Airfoils with Blowing Jet

  • Lee, Ki-Young;Chung, Hyoung-Seog;Cho, Dong-Hyun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.1
    • /
    • pp.111-120
    • /
    • 2008
  • A particle image velocimetry (PIV) technique was employed to investigate the effects of blowing jet on the flow characteristics over stationary and pitch-oscillating airfoils. The Reynolds number was $7.84{\times}10^5$ based on the chord length. It was found that for stationary airfoil cases, continuous and pulsating blowing jets successfully reduced separated wake region at high angles of attack. A comparison study of two different types of jet blowing indicated that pulsating jet is more effective than continuous jet for flow separation control. Pulsating leading-edge blowing postpones flow separation and increased stall angle of attack by $2^{\circ}{\sim}3^{\circ}$. For pitch-oscillating airfoil cases, the PIV results showed that blowing jet efficiently delays the separation onset point during pitch-up stroke, whereas it does not prevent flow separation during pitch-down stroke, even at angles of attack smaller than static ones.

Study on multi-stage magnetic separation device for paramagnetic materials operated in low magnetic fields

  • F. Mishima;Aoi Nagahama;N. Nomura;S. Nishijima
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.13-17
    • /
    • 2023
  • Magnetic separation technology for small paramagnetic particles has been desired for the volume reduction of contaminated soil from the Fukushima nuclear power plant accident and for the separation of scale and crud from nuclear power plants. However, the magnetic separation for paramagnetic particles requires a superconducting high gradient magnetic separation system applied, hence expanding the bore diameter of the magnets is necessary for mass processing and the initial and running costs would be enormous. The use of high magnetic fields makes safe onsite operation difficult, and there is an industrial need to increase the magnetic separation efficiency for paramagnetic particles in as low a magnetic field as possible. Therefore, we have been developing a magnetic separation system combined with a selection tube, which can separate small paramagnetic particles in a low magnetic field. In the previous technique we developed, a certain range of particle size was classified, and the classified particles were captured by magnetic separation. In this new approach, the fluid control method has been improved in order to the selectively classify particles of various diameters by using a multi-stage selection tube. The soil classification using a multi-stage selection tube was studied by calculation and experiment, and good results were obtained. In this paper, we report the effectiveness of the multi-stage selection tube was examined.

The Effects of Two Types of Parental Psychological Control on Dependency, Self-Criticism and Depression in Adolescents (부모의 심리적 통제유형이 청소년의 의존심, 자아비난 및 우울에 미치는 영향)

  • Park, Seong Yeon;Lee, Eun Gyoung;Song, Ju Hyun;Soenens, Bart
    • Korean Journal of Child Studies
    • /
    • v.29 no.5
    • /
    • pp.65-78
    • /
    • 2008
  • This study examined whether parental psychological control influences adolescents' depressive feelings through personality features of dependency and self-criticism. Participants were 315 high school students (M=16 years) who completed questionnaires tapping two types of parental psychological control and student personality and depressive symptoms. Both girls and boys perceived equal levels of maternal and paternal separation-anxious psychological control. Boys perceived higher achievement- oriented psychological control of fathers than mothers; girls perceived equal levels of maternal and paternal achievement-oriented control. Structural relations between types of psychological control, personality features, and depressive symptoms were equivalent for both mothers and fathers and for both boys and girls. Results confirmed that separation-anxious and achievement-oriented control have negative effects on adolescents' adjustment through differential pathways; dependency and self-criticism, respectively.

  • PDF

An Integrated Management Model of OS-RBAC and Separation Of Duty Policy (OS-RBAC과 임무분리 정책의 통합 관리 모델)

  • Byun, Chang-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.1
    • /
    • pp.167-175
    • /
    • 2010
  • Like most large organizations, there are business rules such as 'separation of duty' and 'delegation' which should be considered in access control. From a SOD point of view, previous SOD models built on the (Administrative) Role-Based Access Control model cannot present the best solution to security problems such as information integrity by the limited constituent units such as role hierarchy and role inheritance. Thus, we propose a new integrated management model of administration role-based access control model and SOD policy, which is called the OS-SoDAM. The OS-SoDAM defines the authority range in an organizational structure that is separated from role hierarchy and supports a decentralized security officer-level SOD policy in which a local security officer can freely perform SOD policies within a security officer's authority range without the security officer's intervention.

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

Development of a Forced-Vortex Oil-Water Separator (강제와류 유수분리기의 걔발)

  • 박외철;이광진
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.22-26
    • /
    • 1997
  • A small scale centrifugal oil separator consisted of two concentric tubes was fabricated for spilt oil recovery. With speed control of the inner tube, its performance of oil separation was investigated. Oil-water mixture is separated by forced vortex motion with the rotating inner tube. Velocity and pressure distributions in the tubes were calculated. Control of rotating speed, which is the most influencing parameter, showed an optimum value 946rpm corresponding to the acceleration of 20g at the inner tube surface. Separation performance was suddenly deteriorated at rotating speed higher than 1200rpm.

  • PDF

Analysis of interlinked separation processes using homotopy continuation methods (Homotopy continuation 방법을 이용한 다탑 분리 공정의 해석)

  • 한경택;이강주;윤인섭;김화용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.93-98
    • /
    • 1991
  • An improved and flexible matrix algorithm for solving interlinked separation problems which is based on the homotopy continuation method has been developed. A flexible model of the interlinked stream in standardized matrix form and JACOBIAN generation I algorithm for homotopy continuation are suggested. Also DOF analysis is performed for easy-understanding of equation based simulation of complex column systems. The Algorithm is tested on several problems of interlinked separation processes and some of results are documented.

  • PDF