• Title/Summary/Keyword: Separation condition

Search Result 866, Processing Time 0.027 seconds

Optimum Condition of Soil Dispersion for Remediating Heavy Metal-Contaminated Soils using Wet Magnetic Separation (중금속 오염 토양 정화를 위한 습식자력선별법 사용 시 최적 토양분산 조건)

  • Chon, Chul-Min;Park, Jeong-Sik;Park, Sook-Hyun;Kim, Jae-Gon;Nam, In-Hyun
    • Economic and Environmental Geology
    • /
    • v.45 no.2
    • /
    • pp.121-135
    • /
    • 2012
  • Soil dispersion and heavy metal leaching with two heavy metal-contaminated soils were studied to derive the optimal dispersion condition in the course of developing the remedial technology using magnetic separation. The dispersion solutions of pyrophosphate, hexametaphosphate, orthophosphate and sodium dodecylsulfate (SDS) at 1 - 200 mM and the pH of solutions was adjusted to be 9 - 12 with NaOH. The clay content of suspension as an indicator of dispersion rate and the heavy metal concentration of the solution were tested at the different pHs and concentrations of the dispersion solution during the experiment. The dispersion rate increased with increasing the pH and dispersion agent concentration of the solution. The dispersion efficiency of the agents showed as follows: pyrophosphate > hexametaphosphate > SDS > orthophosphate. Arsenic leaching was sharply increased at 50 mM of phosphates and 100 mM of SDS. The adsorption of $OH^-$, phosphates and dodecysulfate on the surface of Fe- and Mn-oxides and soil organic matter and the broken edge of clay mineral might decrease the surface charge and might increase the repulsion force among soil particles. The competition between arsenic and $OH^-$, phosphates and dodecylsulfate for the adsorption site of soil particles might induce the arsenic leaching. The dispersion and heavy metal leaching data indicate that pH 11 and 10 mM pyrophosphate is the optimum dispersion solution for maximizing dispersion and minimizing heavy metal leaching.

Development of Analysis Method for Cholesterol in Infant Formula by Direct Saponification (직접 검화법을 이용한 조제분유의 콜레스테롤 분석법 개발)

  • Kim, Jin-Man;Park, Jung-Min;Yoon, Tae-Hyung;Leem, Dong-Gil;Yoon, Chang-Yong;Jeong, Ja-Young;Jeong, In-Seek;Kwak, Byung-Man;Ahn, Jang-Hyuk
    • Food Science of Animal Resources
    • /
    • v.31 no.6
    • /
    • pp.944-951
    • /
    • 2011
  • An improved cholesterol analysis method was developed for powdered infant formula by gas chromatographic separation after liquid-liquid extraction and partition. In the official Korea Food Standard method for cholesterol analysis, the water phase and solvent phase were not well separated in the case of emulsified foods such as powdered infant formulas and baby foods. For the rapid and simple sample preparation method, an optimized direct saponification condition was established for heating temperature, heating time, and KOH concentration. From the results, the optimum conditions were as follows: heating temperature $90^{\circ}C$, heating time 60 min, and 16 M KOH 10 mL for a 2 g infant formula sample; improved separation condition for gas chromatography was as follows: the initial oven condition was $250^{\circ}C$ for 25 min, the oven temperature was increased to $290^{\circ}C$ by $10^{\circ}C$/min ratio, and finally the oven temperature remained at $290^{\circ}C$for 9 min. The developed method could be implemented for the study of cholesterol, providing the advantages of reduced inspection time and cost in emulsified foods such as infant formula.

Numerical Simulation of Dynamic Soil-pile Interaction for Dry Condition Observed in Centrifuge Test (원심모형실험에서 관측된 건조 지반-말뚝 동적 상호작용의 수치 모델링)

  • Kown, Sun-Yong;Kim, Seok-Jung;Yoo, Min-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.4
    • /
    • pp.5-14
    • /
    • 2016
  • Numerical simulation of dynamic soil-pile-structure interaction embedded in a dry sand was carried out. 3D model of the dynamic centrifuge model tests was formulated in a time domain to consider nonlinear behavior of soil using the finite difference method program, FLAC3D. As a modeling methodology, Mohr-Coulomb criteria was adopted as soil constitutive model. Soil nonlinearity was considered by adopting the hysteretic damping model, and an interface model which can simulate separation and slip between soil and pile was adopted. Simplified continuum modeling (Kim et al., 2012) was used as boundary condition to reduce analysis time. Calibration process for numerical modeling results and test results was performed through the parametric study. Verification process was then performed by comparing numerical modeling results with another test results. Based on the calibration and validation procedure, it is identified that proposed modeling method can properly simulate dynamic behavior of soil-pile system in dry condition.

A Study on the Application of the Korean Valuation Weights for EuroQoL-5 Dimension (EuroQoL-5 Dimension 한국 가중치 모형의 적용 연구)

  • Lee, Young-Hoon;Choi, Jin-Su;Rhee, Jung-Ae;Ryu, So-Yeon;Shin, Min-Ho;Kim, Jin-Hee
    • Korean Journal of Health Education and Promotion
    • /
    • v.26 no.1
    • /
    • pp.1-13
    • /
    • 2009
  • Objectives: This study was conducted to estimate the health-related quality of life (HRQOL) using EuroQoL-5 Dimension (EQ-5D) and to identify its related factors among urban-dwelling adults. Methods: The data for this study were obtained from 1,134 subjects aged $20\sim91$, who participated in 'Survey on the health status and demand for health' in two cities of Korea (Dong-gu, Gwangju and Suncheon-si, Jeollanamdo). The HRQOL was measured using the EQ-5D instrument and EQ-5D index scores were calculated by two Korean valuation study model using time trade-off method. Results: The mean EQ-5D index scores for all subjects were $0.865{\pm}0.218$ (model A), and $0.921{\pm}0.170$ (model B). The EQ-5D index score was significantly different according to demographic and socioeconomic characteristics (gender, age, marital status, education, occupation, income, and health security system), self-rated health condition, health-related psychological assessments (enough sleep, fatigue rate, stress rate, and degree of satisfaction on the residence). The results of multiple linear regression showed that age, marital status, income, coverage of medical insurance, self-rated health condition, and fatigue rate were significantly related common statistical factors of HRQOL in two Korean valuation study model. Conclusion: Among the adults residing in urban environment, the HRQOL was significantly lower on the subjects with following conditions: higher age, being alone without a spouse as a result of death, divorce or separation, low income, medical aid program, poor self-rated health condition, and chronic fatigue. In order to improve the urban adults' quality of life, healthcare policy and health promotion program must be developed with considerations to factors related to the HRQOL.

Optimization of Manufacturing Condition for Fried Garlic Flake and the Physicochemical Properties (튀긴 마늘 flake 제조조건의 최적화 및 이화학적 특성)

  • Kim, Kyeong-Yee;Lee, Eun-Kyung
    • Korean journal of food and cookery science
    • /
    • v.28 no.6
    • /
    • pp.805-811
    • /
    • 2012
  • This study was carried out in order to optimize the manufacturing condition of fried garlic flakes as well as to investigate the physicochemical properties of the flakes. Fried garlic flake samples were prepared as follows: garlic was sliced by a thickness of 1.5 mm, 2.0 mm, 2.5 mm, which were measured by a thickness gage. The samples were fried in vegetable oil under different temperatures of $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$. The compression strength depending on the height (h) was measured in order to find the thickness effect by the rheometer (force control: 50 N, h: 3.25 mm). Moreover, the sample with 1.5 mm thickness showed crisp phenomena of the split compared with the crush shape of the 2.0 mm and 2.5 mm thick samples. The result of strength for time dependence showed a sample with a thickness of 1.5 mm, which was measured 5~9 times more than the 2.0 mm and 2.5 mm thick samples. We thought the reason that the 1.5 mm sample had less response power equivalent to compression force than the other samples. Alliin has been found to affect the immune responses in the blood, it is a derivative of the amino acid cysteine and is also quite heat stable. The LC system with a UV detection at 210 nm consists of a separation on a Zorbax TMS column and isocratic elution with water and ACN as a mobile phase. The alliin contents of raw and fried garlic flake under $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$ were 18.10 mg/mL, 14.0 mg/mL, 11.6 mg/mL and 11.1 mg/mL, respectively. The decrement of alliin content under different temperature was a small quantity hence, we confirmed that the increasing manufacturing temperature was not affected by the alliin content. Examining for the particle structure of fried garlic flakes by a polarization microscope, the color of the sample treated at $160{\sim}170^{\circ}C$ was pure yellow. Furder, the fiber shaped particle, which has an effect on the tough texture, almost did not appear compared to the different temperature conditions. Finally, the sensory test for the preference of fried garlic flake under different conditions was carried out and the scores for various sensory characteristics were surveyed. According to the physicochemical measurements and sensory evaluation, we confirmed that the optimum manufacturing condition of fried garlic flake was 1.5 mm thick at a temperature of $160{\sim}170^{\circ}C$.

Numerical study of dividing open-channel flows at bifurcation channel using TELEMAC-2D (TELEMAC-2D모형을 이용한 개수로 분류흐름에 대한 수치모의 연구)

  • Jung, Dae Jin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.635-644
    • /
    • 2016
  • This study investigates variation of flow characteristics due to variation of branch channel width and discharge ratio at bifurcation channel using 2D numerical model. The calculated result considering secondary flow is more accurate and stable than without considering one. The diversion flow rate ($Q_3/Q_1$) is reduced by flow stagnation effect according to the interaction of the secondary flow and flow separation zone in branch channel. The less upstream inflow or the lower upstream velocity, the bigger variation of diversion flow rate by changing branch channel width. At uniform downstream boundary condition, the rate of change in Froude number of downstream of main channel($Fr_2$)-diversion flow rate ($Q_3/Q_1$) relations is similar about -2.4843~-2.6675 when branch channel width ratio (b/B) is decreased. At uniform diversion flow rate ($Q_3/Q_1$) condition, the width of recirculation zone in branch channel is decreased when branch channel width ratio (b/B) is decreased. The less upstream inflow in the case of increasing branch channel width or the narrower branch channel width in the case of increasing upstream inflow, the bigger reduction ratio of recirculation zone width. At uniform inflow discharge ($Q_1$) condition, diversion flow rate, the width and length of recirculation zone in branch channel are decreased when branch channel width ratio (b/B) is decreased.

Determination of Aldehydes in Tap Water by Reverse Phase Liquid Chromatography (역상 액체 크로마토그래피에 의한 수도수 중 알데하이드류의 정량)

  • Choi, Yong Wook;Choi, Yun Jung
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.438-446
    • /
    • 1999
  • The optimum analytical method of aldehydes, ozone by-products, was established by reverse phase liquid chromatography. Six aldehydes including formaldehyde, acetaldehyde, acrolein, propionaldehyde, butylaldehyde and benzaldehyde, and one ketone including acetone were selected as aldehyde test samples through preliminary experiments. Such analytical conditions as the pH of citrate buffer solution, reaction temperature, reaction time, and concentration of DNPH, the component and composition of desorption solvent were optimized. As the result, pH 3.0 of citrate buffer solution, 40$^{\circ}C$ of reaction temperature, 15 minutes of reaction time, and 0.012% of DNPH concentration were chosen as optimum conditions. Aldehydes-DNPH derivatives in water were concentrated on $C_18$ Sep-Pak cartridge and followed by elution of their derivatives fraction with THF/ACN(70/30) mixture, and showed recoveries of the range from 87 to 107%. Separation condition on Nova-Pak $C_18$ column with low pressure gradient elution from ACN/MeOH/water(30/10/60) of an initial condition to 80% ACN of a final condition was found to give a good resolution within 20 minutes of run time. 86% to 103% of recovery for aldehydes using this method was similar to that for aldehyde using EPA Method 554 which is ranged from 84% to 103%.

  • PDF

The Study of Modified Sequencing Batch Reactor Process for Small Advanced Wastewater Treatment (소규모 고도하수처리를 위한 변형 연속회분식공정에 관한 연구)

  • Han, Woonwoo;Kim, Kyuhyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • This study was carried out to estimate the performance of modified sequencing batch reactor (SBR) process by the application of SBR process for small advanced wastewater treatment plant. Organic, nitrogen and phosphorus were able to remove in the unit reactor by SBR process and it would be able to select the suitable operation method. The plant was operated to achieve high performance with influent control, optimum anoxic/oxic condition using intermediate aeration method, and solid (sludge) /liquid (effluent) separation by modified decanter. The optimum operating mode was 3Cycles a day and intermediate input and aeration. Under these conditions, the treatment efficiencies were good with 60% of designed flow rate and low influent quality. When the influent concentrations of BOD and CODMn were 120.4 mg/L and 95.7 mg/L, respectively. The effluent concentrations of BOD and CODMn were 6.8 mg/L and 11.0 mg/L, respectively. The average removal efficiencies of BOD and CODMn were 94.4% and 88.5%, respectively. The removal efficiencies of T-N and T-P were 69.6% and 73.6%, respectively when the average T-N and T-P concentrations were 32.2mg/L and 4.65mg/L, respectively. The T-N and T-P removal efficiencies were slightly decreased to 58.8% and 68.5%, respectively in the winter season but its were also stable efficiencies. BOD, T-N and T-P were removed by 90%. 67% and 46% respectively in the first anoxic/oxic condition, in addition to T-P was removed by 70% in the second anoxic/oxic condition. From the results, modified sequencing batch reactor (SBR) process is suitable for small advanced wastewater treatment.

  • PDF

A High Efficiency Power Conversion Circuit with Wide ZVS Range for Large Screen PDP Sustaining Power Module (넓은 영전압 스위칭 범위를 갖는 대화면 PDP용 유지전원단을 위한 고효율 전력 변환회로)

  • Park Kyung-Hwa;Moon Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.578-586
    • /
    • 2005
  • Recently, due to the launch of digital broadcasting service, the demand of Flat Panel Display (FPD) is sharply rising. Among them, the PDP is expected to be one of the most promising digital displays of next generation because of its large screen size, high resolution, thinness and board field of view. Meanwhile, the PDP uses ADS (Address Display-period Separation) scheme which divide one subfield into address and sustaining period to express the grey scale of images. Since the output of sustaining power module Is mostly used for sustaining period, the load of the sustaining power module can be considered as a pulsating load. Due to this particular load condition, if the wide ZVS range of the power switches is not guaranteed, the hard switching causes large amount of switching loss and serious thermal problem in power module. In this paper, a high efficiency power conversion circuit for 60' PDP sustaining power module which achieves wide ZVS range with the help of additional ZVS tank is proposed. According to the various gating methods, the different operations of the proposed converter are presented. And, to confirm the properties of the proposed converter, an experimental prototype of 900W power converter is constructed md tested. As a result, more than $92\%$ of high efficiency is obtained at $10\%$ load condition, and the ZVS operation is achieved from full load to $10\%$ load condition.

Determination of Unit Hydrograph for the Hydrological Modelling of Long-term Run-off in the Major River Systems in Korea (장기유출의 수문적 모형개발을 위한 주요 수계별 단위도 유도)

  • 엄병현;박근수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.4
    • /
    • pp.52-65
    • /
    • 1984
  • In general precise estimation of hourly of daily distribution of the long-term run-off should be very important in a design of source of irrigation. However, there have not been a satisfying method for forecasting of stationar'y long-term run-off in Korea. Solving this problem, this study introduces unit-hydrograph method frequently used in short-term run-off analysis into the long-term run-off analysis, of which model basin was selected to be Sumgin-river catchment area. In the estimation of effective rainfall, conventional method neglects the Soil moisture condition of catchment area, but in this study, the initial discharge (qb) occurred just before rising phase of the hydrograph was selected as the index of a basin soil moisture condition and then introduced as 3rd variable in the analysis of the reationship between cumulative rainfall and cumulative loss of rainfall, which built a new type of separation method of effective rainfall. In next step, in order to normalize significant potential error included in hydrological data, especially in vast catchment area, Snyder's correlation method was applied. A key to solution in this study is multiple correlation method or multiple regressional analysis, which is primarily based on the method of least squres and which is solved by the form of systems of linear equations. And for verification of the change of characteristics of unit hydrograph according to the variation of a various kind of hydrological charateristics (for example, precipitation, tree cover, soil condition, etc),seasonal unit hydrograph models of dry season(autumn, winter), semi-dry season (spring), rainy season (summer) were made respectively. The results obtained in this study were summarized as follows; 1.During the test period of 1966-1971, effective rainfall was estimated for the total 114 run-off hydrograph. From this estimation results, relative error of estimation to the ovservation value was 6%, -which is mush smaller than 12% of the error of conventional method. 2.During the test period, daily distribution of long-term run-off discharge was estimated by the unit hydrograph model. From this estimation results, relative error of estimation by the application of standard unit hydrograph model was 12%. When estimating by each seasonal unit bydrograph model, the relative error was 14% during dry season 10% during semi-dry season and 7% during rainy season, which is much smaller than 37% of conventional method. Summing up the analysis results obtained above, it is convinced that qb-index method of this study for the estimation of effective rainfall be preciser than any other method developed before. Because even recently no method has been developed for the estimation of daily distribution of long-term run-off dicharge, therefore estimation value by unit hydrograph model was only compared with that due to kaziyama method which estimates monthly run-off discharge. However this method due to this study turns out to have high accuracy. If specially mentioned from the results of this study, there is no need to use each seasonal unit hydrograph model separately except the case of semi-dry season. The author hopes to analyze the latter case in future sudies.

  • PDF