• Title/Summary/Keyword: Separation Time

Search Result 1,797, Processing Time 0.025 seconds

Efficiency criteria for optimization of separation cascades for uranium enrichment

  • Sulaberidze, Georgy;Zeng, Shi;Smirnov, Andrey;Bonarev, Anton;Borisevich, Valentin;Jiang, Dongjun
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.126-131
    • /
    • 2018
  • As it is known, uranium enrichment is carried out on industrial scale by means of multistage separation facilities, i.e., separation cascades in which gas centrifuges (GCs) are connected in series and parallel. Design and construction of these facilities require significant investment. So, the problem of calculation and optimization of cascade working parameters is still relevant today. At the same time, in many cases, the minimum unit cost of a product is related to the cascade having the smallest possible number of separation elements/GCs. Also, in theoretical studies, it is often acceptable to apply as an efficiency criterion the minimum total flow to supply cascade stages instead of the abovementioned minimum unit cost or the number of separation elements. In this article, cascades with working parameter of a single GC changing from stage to stage are optimized by two of the abovementioned performance criteria and are compared. The results obtained allow us to make a conclusion about their differences.

Audio Source Separation Method Based on Beamspace-domain Multichannel Non-negative Matrix Factorization, Part I: Beamspace-domain Multichannel Non-negative Matrix Factorization system (빔공간-영역 다채널 비음수 행렬 분해 알고리즘을 이용한 음원 분리 기법 Part I: 빔공간-영역 다채널 비음수 행렬 분해 시스템)

  • Lee, Seok-Jin;Park, Sang-Ha;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.317-331
    • /
    • 2012
  • In this paper, we develop a multichannel blind source separation algorithm based on a beamspace transform and the multichannel non-negative matrix factorization (NMF) method. The NMF algorithm is a famous algorithm which is used to solve the source separation problems. In this paper, we consider a beamspace-time-frequency domain data model for multichannel NMF method, and enhance the conventional method using a beamspace transform. Our decomposition algorithm is applied to audio source separation, using a dataset from the international Signal Separation Evaluation Campaign 2010 (SiSEC 2010) for evaluation.

A Flow Characteristics for a Separation Behavior of Two-body Vehicle (비행 조건에 따른 비행체 단분리의 주위 유동장 해석)

  • Park, Geunhong;Kim, Kiun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.266-267
    • /
    • 2017
  • A numerical investigation of the stage separation behavior of two-body vehicle focusing on its flow characteristics were carried out. For this simulation, separation of a booster from vehicle was modeled by a chimera grid system and calculated by using commercial code, CFD-FASTRAN$^{TM}$. Consideration of a spring force, gravity and relative acceleration of a booster was the essential factor that simulates the realistic situation. In this study, It was validated that the booster separation time decreases with increase in flight mach number and angle of attack. In view of the results so far achieved, it was expected that the dynamics modeling and boundary condition set up applied in this study will be helpful in a estimation of a safe stage separation and event sequence of flight test.

  • PDF

A Study on Surface Charge Characteristics on Various Plastic Materials for Ttiboelectrostatic Separation of Plastic Wastes (폐플라스틱 정전분리를 위한 하전특성에 관한 연구)

  • 김도균;조희찬;전호석
    • Resources Recycling
    • /
    • v.11 no.3
    • /
    • pp.37-45
    • /
    • 2002
  • Triboelectrostatic Separation procese is a technology that different particles charged after contact and rubbing different materials are separated in an electric field. At this time, charged polarity of different materials depends on their own work function. Therefore this study discovers work functions of various plastics and determines charging characteristics for the specific optimum operation condition. The experiment is conducted with two sample sets composed of various different plastics. Each sample is charged by contact and rubbing different materials. Surface charge of charged particles is measured by Faraday Cage. The specific work function of an each plastic is driven by measured charging amount and charged particles are separated in a certain electric field ($\pm$20 kV). At last, the relationship between charging amount and separation efficiency is induced by the separation experiment.

A Study of Numerical Analysis for Stage Separation Behavior of Two-body Vehicle (비행체 단분리 거동 예측에 대한 수치 연구)

  • Park, Geunhong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.91-98
    • /
    • 2018
  • A numerical investigation of stage separation behavior of a two-body vehicle focusing on its flow characteristics is carried out. For this simulation, the separation of a booster from a vehicle is modeled using a chimera grid system and calculated with commercial code, $CFD-FASTRAN^{TM}$. Consideration of spring force, gravity and relative acceleration of a booster is the essential factor of a realistic simulation. In this study, it is validated that the booster separation time decreases with an increase in flight Mach number and angle of attack. In view of results thus far achieved, it is expected that the dynamics modeling and boundary condition set-up applied in this study will be useful for estimating safe stage separation and event sequencing of flight tests.

A Study on Comparision of the Quantity of Phoria as Way to Separation of Binocular Fusion (양안융합의 분리 시간에 따른 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.331-337
    • /
    • 2014
  • Purpose: This is a comparative experimental study on the amount of phoria by the removal time of binocular fusion. In this study, three tests were used for phoria test like Howell test, Thorington test and developed 3D polarizing test. Methods: In this study, it was considered the removal time of binocular fusion for measuring phoria. The three methods were used for measuring quantity of phoria: Howell test, Thorington test and developed 3D Polarizing test. The measurements progressed quickly to avoid eye-strain. So we designed the test charts for marking 3D display modules and the apparatus inserted lenses, like Maddox lens and prism, which are compatible with three phoria tests. The phoria at the moment separation was measured when the binocular fusion was broken through the apparatus and the that at the stable separation was measured when activity of the separated two images like indicated box and figure on horizontal axis stopped. Results: There were statistically significant difference between quantity of phoria at moment separation and that at stable separation. Amount of phoria at moment separation was relatively larger than amount of that at stable separation. In result in exophoria, the quantity of phoria at moment separation was higher than that at stable separation, and in phoria measured by developed 3D polarizing test, it shows the similar results at two condition. Conclusions: For exophoria, the amount of phoria at moment separation of binocular fusion was relatively larger than that at stable separation. The amount of difference between phoria values at moment separation and that at stable separation was alike among three phoria tests. Usually in working, there is no distinction between moment separation and stable separation. But there were definitely the difference between two ways to separate binocular fusion. Therefore, it is need for writing on prescription test name for measuring phoria and condition of separation of binocular fusion.

Time-Resolved Two-Phase PIV Measurements of Freely Rising Bubble Flows with an Image Separation Method (단일 카메라의 영상분리를 이용한 자유 상승 기포의 고속 이상 유동 PIV 계측)

  • Sung Jaeyong;Park Sang Min;Yoo Jung Yul
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • A time-resolved two-phase PIV system using a single camera has been developed, which introduces a method of image separation into respective phase images, and is applied to freely rising single bubble. Gas bubble, tracer particle and background have different gray intensity ranges on the same image frame when reflection and dispersion in the phase interface are intrinsically eliminated by optical filters and fluorescent particles. Further, the signals of the two phases do not interfere with each other. Gas phase velocities are obtained from the separated bubble image by applying the two-frame PTV. On the other hand, liquid phase velocities are obtained from the tracer particle image by applying the cross-correlation algorithm. As a result, the bubble rises rectilinearly just after it is released from an injector and then has a zigzag motion in the far field. From the trajectory of the bubble, it is found that the period of the zigzag motion is closely related to the vortex shedding although the wavelength of it varies along its movement.

  • PDF

Evaluating optimal preprocessing method for separation of microalgae colonies into single cells for image quality (미세조류 이미지 품질 성능 향상을 위한 최적 전처리방법 선정 연구)

  • Sang Yeob Kim;Sung Kyu Maeng
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.109-117
    • /
    • 2024
  • In this study, various pre-treatment methods were evaluated for microalgae separation. These methods aimed to facilitate safe, rapid, and cost-effective online imaging for real-time observation and cell counting. As pre-treatment techniques, heating, chemical hydrolysis, heating combined with chemical hydrolysis, and sonication were employed. The effectiveness of these methods was evaluated in the context of online imaging quality through experimentation on cultivated microalgae (Chlorella vulgaris and Scenedesmus quadricauda). The chemical treatment method was found to be inappropriate for improving image acquisition. The heating pre-treatment method exhibited a drawback of prolonged cell dispersion time. Additionally, the heating combined with chemical hydrolysis method was confirmed to have the lowest dispersion effect for Chlorella vulgaris. Conversely, ultrasonication emerged as a promising technique for microalgae separation in terms of repeatability and reproducibility. This study suggests the potential for selecting optimal pre-treatment methods to effectively operate real-time online monitoring devices, paving the way for future research and applications in microalgae cultivation and imaging.

Harmonic and Percussive Separation Based on NMF and Tonality Mask

  • Choi, Keunwoo;Chon, Sang Bae;Kang, Kyeongok
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.958-961
    • /
    • 2012
  • In this letter, we present a new algorithm for the harmonic and percussive separation of jazz music. Using a short-time Fourier transform and nonnegative matrix factorization, the signal is decomposed into rank components. Each component is then split into harmonic and percussive parts using masks calculated based on their tonalities. Finally, the harmonic and percussive parts are separated after applying the masks and a summation. We evaluate the algorithm based on real audio examples using both objective and subjective assessments. The proposed algorithm performs well for the separation of harmonic and percussive parts of jazz excerpts.

Separation of large DNA molecules by pulsed field gel electrophoresis (역전장 전기영동장치를 이용한 대형 DNA 분리에 관한 연구)

  • Joo, Yi-seok;Casey, Thomas A;Yoon, Yong-dhuk
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.1
    • /
    • pp.81-85
    • /
    • 1993
  • Gel electrophoresis has proven to be one of the most useful of DNA separation and purification. The new technique of pulsed field gel electrophoresis (PFGE) is high resolution separation of large size DNA moleculs. Conventional continuous gel electrophresis can not be separation of large DNA fragments(20~50 k base). Field inversion gel electrophoresis(FIGE) is very useful for large DNA molecules. We have found that a pulse ratio ; 2 : 1, time ; 24hrs., volts ; $10^{volts}/_{cm}$, start ; 0.45sec, end ; 1sec, is most effectively resolves DNA fragment in the 6~50k base.

  • PDF