• 제목/요약/키워드: Separation Coefficient

Search Result 432, Processing Time 0.024 seconds

Analysis of Compressive Strength of Lightweight Air-mixed Soil According to the Properties of Soil (원료토의 특성에 따른 경량기포혼합토의 압축강도 영향인자 분석)

  • Song, Jun-Ho;Im, Jong-Chul;Hong, Seok-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.157-166
    • /
    • 2008
  • To investigate the relationship between compressive strength ($q_u$) of Lightweight Air-mixed soil (LAS) and its physical deformation coefficient ($E_{50}$), a series of unconfined compressive tests have been performed on specimens of LAS according to various dredged soil types by percentage of sand, silt and clay. From the results it was found that the cement content ($C_i$) and unit weight (${\gamma}_m$) are most influence factors on strength, and percentage of sand, silt, clay by grain size analysis (KS F2302) have more effect on compressive strength than other physical properties of soil. It was also found that the rate of strength (a) increases with curing time, but it reduces with the increase of percentage of clay ($C_%$).

Enhancement of phosphate removal using stabilized Fe-Mn particle (Fe-Mn 입자의 안정화를 통한 인산염 효율 향상)

  • Seoyeon Kang;Jeongwoo Shin;Byugnryul An
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.375-382
    • /
    • 2023
  • The binary oxide adsorbent using Fe and Mn (Fe-Mn) has been prepared by precipitation method to enhance the removal of phosphate. Different amounts of chitosan, a natural organic polymer, were used during preparation of Fe-Mn as a stabilizer to protect an aggregation of Fe-Mn particles. The optimal amount of chitosan has been determined considering the separation of the Fe-Mn particles by gravity from solution and highest removal efficiency of phosphate (Fe-Mn10). The application of Fe-Mn10 increased removal efficiency at least 15% compared to bare Fe-Mn. According to the Langmuir isotherm model, the maximum uptake (qm) and affinity coefficient (b) were calculated to be 184 and 240 mg/g, and 4.28 and 7.30 L/mg for Fe-Mn and Fe-Mn10, respectively, indicating 30% and 70% increase. The effect of pH showed that the removal efficiency of phosphate was decrease with increase of pH regardless of type of adsorbent. The enhanced removal efficiency for Fe-Mn10 was maintained in entire range of pH. In the kinetics, both adsorbents obtained 70% removal efficiency within 5 min and 90% removal efficiency was achieved at 1 h. Pseudo second order (PSO) kinetic model showed higher correlation of determination (R2), suggesting chemisorption was the primary phosphate adsorption for both Fe-Mn and Fe-Mn10.

Transport Properties of CO2 and CH4 using Poly(ether-block-amide)/GPTMS Hybird Membranes (Poly(ether-block-amide)/GPTMS 하이브리드 분리막을 이용한 이산화탄소와 메탄의 투과특성)

  • Lee, Keun Chul;Kim, Hyunjoon
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.653-658
    • /
    • 2016
  • Poly(ether-block-amide)(PEBAX$_{(R)}$) resin is a thermoplastic elastomer combining linear chains of hard-rigid polyamide block interspaced soft-flexible polyether block. It was believed that the hard polyamide block provides the mechanical strength and permselectivity, whereas gas transport occurs primarily through the soft polyether block. The objective of this work was to investigate the gas permeation properties of carbon dioxide and methane for PEBAX$^{(R)}$-1657 membrane, and compare with those obtained for other grade of pure PEBAX$^{(R)}$, PEBAX$^{(R)}$-2533 and PEBAX$^{(R)}$ based hybrid membranes. The hybrid membranes based PEBAX$^{(R)}$ were obtained by a sol-gel process using GPTMS ((3-glycidoxypropyl) trimethoxysilane) as the only inorganic precursor. Molecular structure and morphology of membrane were analyzed by $^{29}Si$-NMR, DSC and SEM. PEBAX$_{(R)}$-2533 membrane exhibited higher gas permeability coefficients than PEBAX$^{(R)}$-1657 membrane. This was explained by the increase of chain mobility. In contrast, ideal separation factor of $CO_2/CH_4$ for PEBAX$^{(R)}$-1657 membrane was higher than PEBAX$^{(R)}$-2533 membrane. It was explained by the decrease of diffusion selectivity caused by increase of chain mobility. For PEBAX$^{(R)}$/GPTMS hybrid membrane, gas permeability coefficients were decreased with reaction time. Gas permeability coefficient of $CH_4$ was more significantly decreased than $CO_2$. It can be explained by the reduction of chain mobility caused by the sol-gel process, and strong affinity of PEO segment with $CO_2$. Comparing with pure PEBAX$^{(R)}$-1657 membrane, ideal separation factor of $CO_2/CH_4$ for PEBAX$^{(R)}$/GPTMS hybrid membrane has decreased to 4.5%, and gas permeability coefficient of $CO_2$ has increased 3.5 times.

Identification and Measurement of Hospital-Related Fears in Hospitalized School-Aged Children (학령기 입원아동의 병원관련 공포에 관한 탐색연구)

  • 문영임
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.61-79
    • /
    • 1995
  • When children are admitted to hospital, they have to adapt to new and unfamiliar stimuli. Children may respond with fear to stimuli such as pain or unfamiliar experiences. One goal of nursing is to help hospitalized children to adapt effectively to their hospital experience. Accordingly, nurses need to assess childrens' fears of their hospital experience to contribute to the planning of care to alleviate these fears. The problem addressed by this study was to identify and measure hospital-related fears(hereafter called HRF) in hospitalized school-aged children. The study was conceptualized with Roy's model. A descriptive qualitative approach was used first, followed by a quantitative approach. This study was conducted from November 30, 1989 to January 12, 1991. The sample consisted of 395 hospitalized school-aged children selected through an allocated sampling technique in nine general hospitals. The HRF questionnaire (three point likert scale ) was developed by a delphi technique. The data were analyzed by an SAS program. Factor analysis was used for the examination of component factors. Differences in the HRF related to demographic variables were examined by t-test, analysis of variance and the Scheffe test. The crude scores of the HRF scale were transformed into T- scores to calculate the standard scores. The results included the following : 1. Forty-four items were derived from 188 statements identifying the childrens' hospital-re-lated fears. These items clustered into 14 factors, fear of injections, operations, bodily harm others' pain, medical rounds, physical examinations, medical staff, disease process, blood and X-rays, drugs and cockroaches, tests, harsh discipline from parents or staff, being absent from school, and separation from family. The 14 factors was classified into four categories,'pain','the unfamiliar','the un-known' and 'separation'. 2. The reliability of the HRF instruments was .92(Cronbach's alpha). In the factor analysis, Cronbach's alpha coefficients for the 14 factors ranged from .84 to .86 and Cronbach's alpha coefficients for the four categories ranged from .70 to .84. Pearson correlation coefficient scores for relationships among the 14 factors ranged from ,11 to .50, and among the four categories, from ,44 to ,63, indicating their relative independence. 3. The total group HRF score ranged from 45 to 130 in a possible range of H to 132, with a mean of 74.51. The fears identified by the children were, in order, injections, harsh discipline by parents or staff, bodily harm, operations, medical staff, disease process, and medical rounds ; the least feared was others' pain. The fear item with the highest mean score was surgery and the lowest was examination by a doctor. HRF scores were higher for girls than for boys, and for grade 1 students than for grade 6 students. HRF scores were lower for children whose fathers were over 40 than for those whose fathers were in the 30 to 39 age group, and whose mothers were over 35 than for those whose mothers were in the 20 to 34 age group. HRF scores were lower when the mother rather than any other person stayed with the child. The expressed fear of pain, the unfamiliar, the un-known and of separation directs nurses' concern to the threat felt by hospitalized children to their concept of self. This study contributes to the assessment of fears of hospitalized children and of stimuli impinging on those fears. Accordingly, nursing practice will be directed to the alleviation of pain, pre-admission orientation to the hospital setting and routines, initiation of information about procedures and experiences and arrangments for mothers to stay with their children. Recommendations were made for further research in different settings and for development and testing of the instrument.

  • PDF

Image Analysis of Angle Changes in the Forearm during Elbow Joint Lateral General Radiography: Evaluation of Humerus Epicondyle and Elbow Joint (팔꿉관절 측방향 일반촬영에서 아래팔뼈 각도 변화에 따른 영상 분석 : 위팔뼈 위관절융기와 팔꿉관절 평가)

  • Hyo-Soo Shin;Hye-Won Jang;Jong-Bae Park;Ki Baek Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.607-614
    • /
    • 2023
  • Clear overlapping of the bilateral epicondyle and proper separation of the elbow joint are crucial for obtaining accurate lateral general radiographs of the elbow. However, due to the complex anatomical structure of the elbow, achieving optimal positioning is challenging, leading to the need for repeated x-ray examinations. Therefore, the purpose of this study was to investigate the angle of the forearm in patients where accurate lateral images of the elbow joint can't be obtained after vertical incidence using a styrofoam device during elbow joint lateral x-ray imaging. Twenty patients were enrolled in our study following the established protocol. First, a vertical x-ray at an angle of 0° between the forearm and the table was taken (control group). Here, if the lateral image of the elbow joint was deemed inadequate, the forearm angle was adjusted using custom-made styrofoam supports with 5° and 10° inclinations (experimental groups). For the evaluation method, two assessors utilized a 5-point Likert scale to assess the images. The reliability of the assessments was analyzed using Cronbach's alpha coefficient. As a result, patients with inadequate overlap of the bilateral epicondyle and separation of the elbow joint in the initial examination (control group) were able to obtain the best images when setting a 10° angle between the forearm and the table. The subjective evaluation was 1.6 ± 0.8 points at 0°, 2.7 ± 0.8 points at 5°, and 4.4 ± 1.3 points at 10°, respectively. The reliability analysis for the angles of 0°, 5°, and 10° yielded Cronbach's alpha values of 0.867, 0.697, and 0.922, respectively. In conclusion, when it is not possible to obtain accurate images using the conventional position and X-ray beam direction, it is considered that by initially acquiring images with an angle of 10° between the forearm and the table, and gradually decreasing the angle while obtaining images, it would be possible to achieve the optimal image while reducing the number of repeat examinations.

Emulsion Liquid Membrane Transport of Heavy Metal Sons by Macrocyclic Carriers (거대고리 운반체에 의한 중금속이온의 에멀죤 액체막 수송)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.223-232
    • /
    • 1995
  • New two macrocyclic compounds using as carriers of liquid emulsion menbrame, have been synthesized. These reuslts provide evidance for the usefulness of the theory in designing the systems. The efficiency of selective transport for heavy metal ions have been discussed from the membrane systems that make use of $SCN^-$,<>,$I^-$,CN- and $Cl^-$ ion as co-anions in source phase and make use of $S_2O_3^{2-}$ and $P_2O_7^{4-}$ ion as receiving phase, respectively. The transport rate of M(II) was highest when a maximum amount of the M(II) in the source phase was present as$Cd(SCN)_2$$(P[SCN^-]= 0.40M)$, $Hg(SCN)_2([SCN^-]=0.40M)$ and Pd(CN)$([CN^-]= 0.40M)$. The Cd(II) and Pb(II) over each competitive cations were well transprted with 0.3M-S2032- and 0.3M-P2O74-, respectively in the receiving phase. Results of this study indicate that two criteria must be met in order to have effective macrocycle-mediated transport in these emulsion system. First one must effective extraction of the $M^{n+}$ into the toluene systems. The effectiveness of this extraction is the greatest if locK for $M^{n+}$macrocycle interaction is large and if the macrocycle is very insoluble in the aqueous phase. Second, the ratio of the locK values (or Mn+-receiving phase ($S_2O_3^{2-}$- or $P_2O_7^{4-}$) to $M^{n+}$-macrocycle (($L_1$이나 $L_2$) interaction must be large enough to ensure quantitative stripping of Mn+(($Cd^{2+}$,$Pb^{2+}$)at the toluene receiving Phase interface. $L_1$(3.5-benzo-10,13,18,21-tetraoxa-1,7,diazabicyclo(8,5,5) eicosan) forms a stable ($Cd^{2+}$ and >,$Pb^{2+}$ complexes and $L_1$ is very insoluble in water and its $Cd^{2+}$ and >,$Pb^{2+}$ complex is considerably less stable than $Cd^{2+}$-(S2O3)22- and $Pd^{2+}-P_2O_7^{4-}$ complexes. On the other hand, the stability of the $Hg^{2+}$)+-$L_1$( complex exceed that of the $Hg^{2+}$- (S2O3)22- and Hg2+-P2O74-, and the distribution coefficient of $L_2$(5,8,15,18,23,26-hexaoxa-1,12- diazabicyclo-(10,8,8) octacosane) is much smaller than that of $L_1$. Therefore, the partitioning of Lr is favored by the aqueous receiving Phase, and little heavy metal ions transport is seen despite the large logK for $Hg^{2+}$+-$L_1$ and $Mn^+$($Cd^{2+}$+, $Pb^{2+}$+ and $Hg^{2+}$)-$L_2$ interactions. Key Words : macrocycles, transport, heavy metal, co-anion, source phase, receiveing, complex separation, interaction, destribution coefficient.

  • PDF

Estimation of Soil Surface Temperature by Heat Flux in Soil (Heat flux를 이용한 토양 표면 온도 예측)

  • Hur, Seung-Oh;Kim, Won-Tae;Jung, Kang-Ho;Ha, Sang-Keon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.3
    • /
    • pp.131-135
    • /
    • 2004
  • This study was carried out for the analysis of temperature characteristics on soil surface using soil heat flux which is one of the important parameters forming soil temperature. Soil surface temperature was estimated by using the soil temperature measured at 10 cm soil depth and the soil heat flux measured by flux plate at 5 cm soil depth. There was time lag of two hours between soil temperature and soil heat flux. Temperature changes over time showed a positive correlation with soil heat flux. Soil surface temperature was estimated by the equation using variable separation method for soil surface temperature. Arithmetic mean using temperatures measured at soil surface and 10 cm depth, and soil temperature measured at 5 cm depth were compared for accuracy of the value. To validate the regression model through this comparison, F-validation was used. Usefulness of deductive regression model was admitted because intended F-value was smaller than 0.001 and the determination coefficient was 0.968. It can be concluded that the estimated surface soil temperatures obtained by variable separation method were almost equal to the measured surface soil temperature.

A Study on the Effect of Sample Storage Condition on the RIA Results of Plasma renin activity Test (Plasma renin activity 검사의 검체 보관 방법이 방사면역 측정법 결과에 미치는 영향에 대한 고찰)

  • Choe, Jin-joo;Back, Song-ran;Yoo, Seon-hee;Lee, Sun-ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.29-33
    • /
    • 2021
  • Purpose Plasma renin activity (PRA) test is important for the diagnosis of primary aldosteronism. PRA is an easily deformed substance in vitro and affected by temperature changes. Laboratory of ASAN medical center has consistently found that there was a difference between the initial and re-experimental results. We compared and analyzed the differences in PRA test results according to the sample storage status. Materials and Methods The measurement of PRA was performed by using the radioimmunoassay. From August to September 2020, 43 PRA re-test samples were tested with different sample storage condition. The first group was re-examined by freezing the plasma-separated samples at -18℃, and the second group was re-examined with refrigerated EDTA sample. Also, additional tests were conducted on 13 PRA samples to verify the effect on thawing temperature differences in plasma-separated samples. The same samples were divided into two parts and stored frozen at -18℃, respectively, and thawing samples in room temperature and those in refrigerator were were conducted. Each result was compared and analyzed based on the initial experimental results. Results The results of re-examination after frozen storing plasma separation samples showed a lower correlation than the results of re-examination with EDTA plasma samples in refrigerator. When calculating the percentage based on the initial test results, the average percentage of each was 404.9% and 133.8%. The correlation coefficient was also R=0.8501 and R=0.9966, respectively, showing a higher correlation between plasma in the refrigerated sample EDTA tube. In comparison experiments with differences in thawing temperature, average percentage of the results of initial test and room temperature thawing was 94.3% and the average percentage of the results of refrigerated thawing was 88.0%. After again freezing the sample, the average percentage of the second room temperature thawing result is 107.5%, and the second refrigerated thawing group is 112.7%. Both groups showed an increase from first thawing. Conclusion A comparative analysis of retesting according to differences in sample storage methods in PRA tests showed a higher correlation between the results of retesting of the refrigerated EDTA plasma. And repeated freezing and melting of plasma separation samples, regardless of temperature during defrosting, has been shown to affect results. Therefore, retest of PRA should re-collect plasma from original EDTA plasma to increase reproducibility.

A Study on Spectra of Laser Induced Flourescence in Phantom of N-propyl-N,N-dimethylethanolamine (N-propyl-N,N-dimethylethanolamine의 Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구)

  • Kim, Ki-Jun;Lee, Joo-Ho;Lee, Joo-Youb;Sung, Wan-Mo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.330-338
    • /
    • 2015
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering of N-propyl-N,N-dimethylethanolamine, fluorescence agent and absorption agent were interpreted for the scattered fluorescence intensity and wavelength. They have been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF) and flocculation. The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process. The values of scattering coefficient ${\mu}_s$ are large by means of the increasing scattering of scatterer, The values have been found that the slope decays exponentially as a function of concentration from laser source to detector by our experimental result. It may also aid in designing the best model for oil chemistry, bio-pharmaceutical, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

Monitoring of Veterinary Antibiotics in Agricultural Soils using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 농경지 토양 중 항생제 모니터링)

  • Lee, Young-Jun;Choi, Jeong-Heui;Chung, Hyung Suk;Lee, Han Sol;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.166-174
    • /
    • 2016
  • BACKGROUND: The current study developed a monitoring method of 6 veterinary antibiotics (amoxicillin, ampicillin, enrofloxacin, tetracycline, chlortetracycline, oxytetracycline) in agricultural soils using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization mode.METHODS AND RESULTS: Sample preparation was carried out using acidic acetonitrile and citrate salts followed by purification with dispersive solid phase extraction (d-SPE). Separation on Eclipse Plus C18 column was conducted in gradient of the mobile phase, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations expressed as the coefficient of determination was good with R2≥0.9900. The limit of quantifications (LOQs) ranged from 0.5 to 10 μg/kg for all analytes. Analysis of 51 agricultural soil samples taken in the Republic of Korea revealed concentrations less than 1.9 μg/kg for enrofloxacin, 75.5 μg/kg for chlortetracycline.CONCLUSION: The method was successfully applied to monitor 6 veterinary antibiotics from 51 field incurred agricultural soil samples in 17 provincial areas throughout the Republic of Korea. The developed method was simple, easy, and versatile and can be used for monitoring various veterinary antibiotics in soil.