• Title/Summary/Keyword: Separation Behavior Analysis

Search Result 197, Processing Time 0.026 seconds

Investigation into the Internal Flow Characteristics of a Pump-turbine Model

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.4
    • /
    • pp.36-42
    • /
    • 2015
  • This is a study about one of the most widely used hydro machinery all over the world - pump-turbine. The system has an impeller which pumps water to an upper reservoir during the night and the same impeller acts as a runner for turbine mode during the day for providing stable electrical power to the grid. The internal flow analysis is investigated in this study to help understand how the water passes through the passage of the vanes and blades, providing the designer with useful information on the behavior of recirculation flows which could reduce the efficiency of the pump-turbine. The 100 kW pump-turbine model has H = 32 m, $Q=0.336m^3/s$ and $N=1200min^{-1}$. For this study there are 7 blades, 19 stay vanes and 20 guide vanes. From this study, it was observed that this pump-turbine design showed very good internal flow characteristics with no flow separation and no recirculation flows in normal operation mode.

Free In-plane Vibration of a Clamped Circular Plate (고정된 원형 플레이트의 평면내 자유진동)

  • Park, Chan-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.836-839
    • /
    • 2005
  • The in-plane vibration response of a clamped circular plate should be predicted in many applications. Up to now, papers on the in-plane vibration of rectangular plate are published. However, analytical derivation on the in-plane vibration of the clamped circular plate is not carried out. Therefore, the in-plane vibration of the clamped circular plate is the concern of this paper. In order to derive the equations of motion for the clamped circular plate in the cylindrical coordinate, the kinetic energy and potential energy for the in-plane behavior are obtained by us ing the stress-strain-displacement expressions. Application of Hamilton's principle leads to two sets of differential equations. These displacement equations were highly coupled. It is possible to obtain a simpler set of equations by introducing Helmholtz decomposition. Substituting them into the coupled differential equations, we obtain the uncoupled equations of motion. In order to solve them, we assume that the solutions are harmonic. Then, they lead to the wave equations. Using the separation of variable, we obtain the general solutions for the equations. Based on the solutions, the displacements for r and $\theta$ direction are assumed. Finally we obtain the frequency equation for the clamped circular plate by the application of boundary conditions. The derived equation is compared with the finite element analysis for validation by using the some numerical examples.

  • PDF

A Study on the Location and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 배치 및 규모에 관한 연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.93-104
    • /
    • 2019
  • Purpose: To establish the building guidelines and to analyze the function of Regional Public Hospitals, the survey was conducted primarily on the current status focusing on the location and relationship of the department, area composition ratio, area per bed, and area per operating room. Methods: The research methods of this paper are as follows. 1) A literature survey on the function of the operating and related departments, 2) A drawing analysis for spatial composition and net area calculation. Results: The area of the Operation Department in the Regional Public Hospitals with 200 to 300 beds are as follows. Area ratio: 3.35%, area per Bed: 2.53㎡/bed, the number of beds per operating room: 64.37bed, area per operating room: 146.46㎡/n, area per operating room by plan type: integration corridor 133.84㎡/n, separation corridor 184.82㎡/n. Implications: This paper analyzed data on the current state of Operation Departments for setting up the function and role for the Regional Public Hospital. In the future, it is also required to provide size that takes into account user behavior and the user's psychological aspect in order to suggest appropriate area.

Performance Analysis of the NREL Phase IV Wind Turbine by CFD (CFD에 의한 NREL Phase IV 풍력터빈 성능해석)

  • Kim, Bum-Suk;Kim, Mann-Eung;Lee, Young-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.652-655
    • /
    • 2008
  • Despite of the laminar-turbulent transition region co-exist with fully turbulence region around the leading edge of an airfoil, still lots of researchers apply to fully turbulence models to predict aerodynamic characteristics. It is well known that fully turbulent model such as standard k-${\varepsilon}$ model couldn't predict the complex stall and the separation behavior on an airfoil accurately, it usually leads to over prediction of the aerodynamic characteristics such as lift and drag forces. So, we apply correlation based transition model to predict aerodynamic performance of the NREL (National Renewable Energy Laboratory) Phase IV wind turbine. And also, compare the computed results from transition model with experimental measurement and fully turbulence results. Results are presented for a range of wind speed, for a NREL Phase IV wind turbine rotor. Low speed shaft torque, power, root bending moment, aerodynamic coefficients of 2D airfoil and several flow field figures results included in this study. As a result, the low speed shaft torque predicted by transitional turbulence model is very good agree with the experimental measurement in whole operating conditions but fully turbulent model(k-${\varepsilon}$) over predict the shaft torque after 7m/s. Root bending moment is also good agreement between the prediction and experiments for most of the operating conditions, especially with the transition model.

  • PDF

Creep analysis of the FG cylinders: Time-dependent non-axisymmetric behavior

  • Arefi, Mohammad;Nasr, Mehrdad;Loghman, Abbas
    • Steel and Composite Structures
    • /
    • v.28 no.3
    • /
    • pp.331-347
    • /
    • 2018
  • In this paper history of stresses, strains, radial and circumferential displacements of a functionally graded thick-walled hollow cylinder due to creep phenomenon is investigated. The cylinder is subjected to an arbitrary non-axisymmetric two dimensional thermo-mechanical loading and uniform magnetic field along axial direction. Using equilibrium, strain-displacements and stress-strain relations, the governing differential equations of the problem containing creep strains are derived in terms of radial and circumferential displacements. Since the displacements are varying with time due to creep phenomenon, an analytical solution is not available for these equations. Thus, a semi-analytical procedure based on separation of variables and Fourier series together with a numerical procedure is employed. The numerical results indicate that the non-axisymmetric loading and the material grading index have significant effect on stress redistributions. Moreover, by proper selection of material for any combination of non-axisymmetric loading, one can arrive suitable response for the cylinder to achieve optimal design. With some simplifications, the results are validated with the existing literature.

EXPERIMENTAL REPRODUCTION AND NUMERICAL ANALYSIS OF THE SIDE FORCE ON AN OGIVE FOREBODY AT A HIGH ANGLE OF ATTACK (고받음각 동체에 발생하는 측력의 실험적 재현 및 수치적 분석)

  • Lee, E.S.;Lee, J.I.;Lee, K.S.
    • Journal of computational fluids engineering
    • /
    • v.18 no.1
    • /
    • pp.28-35
    • /
    • 2013
  • Behavior of the side force generated at high angles of attack by two ogive-cylinder bodies of revolution with nose fineness ratio of 2.3 (B1) and 3.5 (B2) and the effect of a strip placed close the nose tip of each body (B1S and B2S) are analyzed through the wind tunnel test at ReD=200,000 and a=42~60 deg. The side force generated by B1 is increased by placing a strip. The side force generated by B2 is in the starboard direction and its magnitude is higher than that of the B1S. The effect of the strips with various dimensions placed on B2 is investigated. It is found that the 4-layer strip placed on the starboard reversed the direction of the side force into port direction. It is confirmed by numerical simulations that the strip promotes the flow separation and increases the average pressure on the side where it is placed and consequently produces the side force in the corresponding direction.

Shielding effects and buckling of steel tanks in tandem arrays under wind pressures

  • Portela, Genock;Godoy, Luis A.
    • Wind and Structures
    • /
    • v.8 no.5
    • /
    • pp.325-342
    • /
    • 2005
  • This paper deals with the buckling behavior of thin-walled aboveground tanks under wind load. In order to do that, the wind pressures are obtained by means of wind-tunnel experiments, while the structural non linear response is computed by means of a finite element discretization of the tank. Wind-tunnel models were constructed and tested to evaluate group effects in tandem configurations, i.e. one or two tanks shielding an instrumented tank. Pressures on the roof and on the cylindrical part were measured by pressure taps. The geometry of the target tank is similar in relative dimensions to typical tanks found in oil storage facilities, and several group configurations were tested with blocking tanks of different sizes and different separation between the target tank and those blocking it. The experimental results show changes in the pressure distributions around the circumference of the tank for half diameter spacing, with respect to an isolated tank with similar dimensions. Moreover, when the front tank of the tandem array has a height smaller than the target tank, increments in the windward pressures were measured. From the computational analysis, it seems that the additional stiffness provided by the roof prevents reductions in the buckling load for cases even when increments in pressures develop in the top region of the cylinder.

Analysis of the Flexural Strength of Reinforced Concrete Beams Strengthened with Prestressed Carbon Fiber-Reinforced Polymer Plates (CFRP판으로 프리스트레싱 보강된 RC 보의 휨강도 해석)

  • Woo, Sang-Kyun;Hong, Ki-Nam;Han, Sang-Hoon;Song, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.181-192
    • /
    • 2007
  • The purpose of this study is to analyse and compare experimentally flexural behavior of RC beams strengthened with CFRP plates by different methods, and finally suggest the evaluation equations of flexural capacity of RC beams with the aim of application of prestressed CFRP strengthening. The experimental parameters are compressive strength, reinforcement ratio, prestressing level and strengthening methods. The non-prestressed specimens failed on account of separation of the plates from the beams due to premature de-bonding, while most of the prestressed specimens failed due to CFRP plate fracture. The evaluation equations of flexural capacity of RC beams is suggested and these equations have a good reliability in predicting flexural strength of RC beams.

Explaining the Drift Behavior of Caffeine and Glucosamine After Addition of Ethyl Lactate in the Buffer Gas of an Ion Mobility Spectrometer

  • Fernandez-Maestre, Roberto;Velasco, Andres Reyes;Hill, Herbert H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.1023-1028
    • /
    • 2014
  • Protonated caffeine ($CH^+$) and glucosamine ($GH^+$) overlapped in an analysis with ion mobility spectrometryquadrupole mass spectrometry. Ethyl lactate vapor (L) at different concentrations from 0 to 22 mmol $m^{-3}$ was added as a buffer gas modifier to separate these signals. The drift times of $CH^+$ and $GH^+$ increased with L concentration. The drift time increase was associated to clustering equilibria of $CH^+$ and $GH^+$ with one molecule of L and the equilibrium of $GH^+$ was more displaced to the formation of $GLH^+$ than that of $GLH^+$. $GH^+$ clustered more to L than $CH^+$ because $GLH^+$ formed more stable hydrogen bonds (26.30 kcal/mol) than $GLH^+$ (24.66 kcal/mol) and the positive charge in $GH^+$ was more sterically accessible than in $CH^+$. The aim of this work was to use theoretical calculations to guide the selection of a buffer gas modifier for IMS separations of two compounds that overlap in the mobility spectra and predict this separation, simplifying that empirical process.

Determination of Recombinant Human Epidermal Growth factor (rhEGF) in a Pharmaceutical Preparation by Capillary Electrophoresis

  • Hwang, Kyung-Hwa;Lee, Kang-Woo;Kim, Chang-Soo;Han, Kun;Chung, Youn-Bok;Moon, Dong-Cheul
    • Archives of Pharmacal Research
    • /
    • v.24 no.6
    • /
    • pp.601-606
    • /
    • 2001
  • A simple assay method of recombinant human epidermal growth factor (rhEGF) in a pharmaceutical preparation was studied and validated by capillary electrophoresis (CE) using micellar electrokinetic chromatography (MEKC) techniques. Factors affecting the migration behavior and separation performances of the peptide; type of buffers pH, butler concentration, and concentration of sodium dodecyl sulfates (SDS) were investigated to optimize the analytical performance. CE was performed using running buffers 50.0 mM borate (pH 8.5) containing 12.5 mM SDS at 20 $mutextrm{V}$ of the applied voltage. Calibration curves for the rhEGF showed good linearity (r>0.999) over the wide dynamic range from 1.25 to $100{\mu\textrm{g}}/ml$. Sample analysis was performed by using standard addition method to eliminate the matrix effects of dosage vehicle. This method is assumed to be useful for quality control (QC) of various forms of pharmaceutical products of the peptide.

  • PDF