• Title/Summary/Keyword: Separated instrument

Search Result 42, Processing Time 0.029 seconds

Retrieval of a separated nickel-titanium instrument using a modified 18-guage needle and cyanoacrylate glue: a case report

  • Andrabi, Syed Mukhtar-Un-Nisar;Kumar, Ashok;Iftekhar, Huma;Alam, Sharique
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.2
    • /
    • pp.93-97
    • /
    • 2013
  • During root canal preparation procedures, the potential for instrument breakage is always present. When instrument breakage occurs, it leads to anxiety of the clinician and as well as a metallic obstruction of the canal which hinders further cleaning and shaping. Separated instruments must always be attempted for retrieval and if retrieval is not possible bypass should be tried. With the increased use of nickel-titanium (NiTi) instruments the incidence of separated instruments has increased. A considerable amount of research has been done to understand the various factors related to the fracture of NiTi instruments to minimize its occurrence. This paper presents a review of the literature regarding the fracture of NiTi instruments and also describes a case report showing the use of a modified 18-guage needle and cyanoacrylate glue to retrieve a separated NiTi instrument from the mesiolingual canal of a mandibular first molar.

An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method- (眞圓度 測定器의 誤差特性에 대한 解析 -위상차법-)

  • 한응교;허문석;박익근
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).

  • PDF

Comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit for the removal of separated endodontic instruments

  • Pruthi, Preeti Jain;Nawal, Ruchika Roongta;Talwar, Sangeeta;Verma, Mahesh
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.14.1-14.7
    • /
    • 2020
  • Objective: The aim of this study was to perform a comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit (TFRK) for the removal of broken endodontic instruments. Materials and Methods: A total of 80 extracted human first mandibular molars with moderate root canal curvature were selected. Following access cavity preparation canal patency was established with a size 10/15 K-file in the mesiobuccal canals of all teeth. The teeth were divided into 2 groups of 40 teeth each: the P group (ProUltra tips) and the T group (TFRK). Each group was further subdivided into 2 smaller groups of 20 teeth each according to whether ProTaper F1 rotary instruments were fractured in either the coronal third (C constituting the PC and TC groups) or the middle third (M constituting the PM and TM groups). Instrument retrieval was performed using either ProUltra tips or the TFRK. Results: The overall success rate at removing the separated instrument was 90% in group P and 95% in group T (p > 0.05) The mean time for instrument removal was higher with the ultrasonic tips than with the TFRK (p > 0.05). Conclusion: Both systems are acceptable clinical tools for instrument retrieval but the loop device in the TFRK requires slightly more dexterity than is needed for the ProUltra tips.

Recycling of PC/ABS Blend Used in Instrument Panel of Automotive (자동차 Instrument Panel에 사용된 PC/ABS계의 재활용)

  • Lee, Chang Hyung;Jung, In Kwon;Lee, Yong Moo;Oak, Sung Hyun;Choi, Hyeong Ki
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.118-123
    • /
    • 1999
  • The recycle of the polycarbonate(PC)/acrylonitrile-butadiene-styrene(ABS) separated from the instrument panel (In-Panel) of the automotive was investigated. The small amount of polyurethane(PU) foam contained in the separated PC/ABS decreased the mechanical properties of the recycled PC/ABS. However, it is found that the PU foam formed the dispered phase of small particles at high temperature ($260^{\circ}C$) under high shear of the twin extruder, whereas it formed the big particles at low extrusion temperature ($220^{\circ}C$). The mechanical properties of the recycled PC/ABS extruded at high temperature was better than those at low temperature, which enabled the recycled PC/ABS seperated from In-Panel to be applied to the radiator grille without the addition of the compatibilizers or virgin PC/ABS. This was ascribed to the smaller particle sizes of the PU foam formed at high extrusion temperature under high shear.

  • PDF

MANAGEMENT OF SEPARATED FILE IN THE ROOT CANAL (근관 내 File의 파절 시 대처 방안)

  • Kim, Hye-Jeong;Jang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.161-168
    • /
    • 2006
  • During root canal preparation procedures, the potential for instrument separation is always present. Files, a lentulo, a Gates-Glidden (GG) bur or any manufactured obstruction can be left behind in the canal Nickel-titanium (NiTi) rotary files are in common usage in these days. Despite their undeniable advantages, there is a potential risk of separation within the canals. It is very rapid, unpredictable, and creates a great deal of stress for the practitioner. When an endodontic instrument separates, the best option is to remove it. Ultrasonic instruments and microscopes have improved the success rate for removing separated instruments. But It is difficult and not always possible. Therefore prevention is the key. In this case report, several management methods of separated file in the canal are presented.

Implementation of the High-Quality Audio System with the Separately Processed Musical Instrument Channels (악기별 분리처리를 통한 고음질 오디오 시스템 구현)

  • Kim, Tae-Hoon;Lee, Sang-Hak;Kim, Dae-Kyung;Lee, Sang-Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.346-353
    • /
    • 2013
  • This paper deals with the implementation of a high-quality audio system for karaoke. For improving the key/tempo changes performance, we separated the audio into many musical instrument channels. By separating musical instrument channels, high-quality key/tempo changes can be achieved and we confirmed this using the cross-correlation distribution and the MOS evaluation. The improved audio system was implemented using the TMS320C6747 DSP with fixed/floating-point operations. The implemented audio system can perform the multi-channel WMA decoding, the MP3 encoding/decoding, the wav playing, the EQ, and the key/tempo changes in real time. The WMA channels used for processing the separated instrument channels. The audio system includs the MP3 encoding/decoding function for playing and recording and the wav channel for the effect sound.

Arthroscopic Capsular Repair without Relaying Sutures: 'Simple Sewing Technique'

  • Kim, Hyungsuk;Song, Hyun Seok;Kang, Seung Gu;Han, Sung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.3
    • /
    • pp.146-148
    • /
    • 2019
  • We report a simple technique for repairing capsular tear, using only a hook-like, cannulated instrument and braided sutures without relaying steps. A No. 2 braided suture is passed through the lumen of the instrument. Under direct arthroscopic view, the tip of the instrument is passed through the side of the capsule that has previously been separated with the probe. One end of the suture is retrieved with a grasper through a separate portal. The tip is moved back without withdrawing through the skin, and reinserted into the other side of the capsule. Holding the end retrieved earlier, the other end of the suture is retrieved with a suture retriever. After complete removal of the instrument, the suture is tied through a cannula using the standard knot tying techniques. The same procedures are repeated for other required knots.

Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study

  • Liliana Machado Ruivo;Marcos de Azevedo Rios;Alexandre Mascarenhas Villela;Alexandre Sigrist de Martin;Augusto Shoji Kato;Rina Andrea Pelegrine;Ana Flavia Almeida Barbosa;Emmanuel Joao Nogueira Leal Silva;Carlos Eduardo da Silveira Bueno
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.49.1-49.8
    • /
    • 2021
  • Objectives: To evaluate the fracture incidence of Reciproc R25 instruments (VDW) used during non-surgical root canal retreatments performed by students in a postgraduate endodontic program. Materials and Methods: From the analysis of clinical record cards and periapical radiographs of root canal retreatments performed by postgraduate students using the Reciproc R25, a total of 1,016 teeth (2,544 root canals) were selected. The instruments were discarded after a single use. The general incidence of instrument fractures and its frequency was analyzed considering the group of teeth and the root thirds where the fractures occurred. Statistical analysis was performed using the χ2 test (p < 0.01). Results: Seven instruments were separated during the procedures. The percentage of fracture in relation to the number of instrumented canals was 0.27% and 0.68% in relation to the number of instrumented teeth. Four fractures occurred in maxillary molars, 1 in a mandibular molar, 1 in a mandibular premolar and 1 in a maxillary incisor. A greater number of fractures was observed in molars when compared with the number of fractures observed in the other dental groups (p < 0.01). Considering all of the instrument fractures, 71.43% were located in the apical third and 28.57% in the middle third (p < 0.01). One instrument fragment was removed, one bypassed, while in 5 cases, the instrument fragment remained inside the root canal. Conclusions: The use of Reciproc R25 instruments in root canal retreatments carried out by postgraduate students was associated with a low incidence of fractures.

Development of Low-inertia Master device for Haptic system configuration of surgical robot (수술용 로봇 햅틱 시스템 구성을 위한 저관성 마스터 장치 핸들부 개발)

  • Kang, Byeong-Ho;Yoon, Sung-Min;Lee, Min Cheol;Kim, Chi-Yen
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.267-275
    • /
    • 2012
  • When using commercialized robot assisted laparoscopic, surgeon has met some problems to depend only on image of the surgical field. To solve it, there were various researches. The previous study showed that it is possible to estimate the operation force on the commercialized instrument inside patient without sensors. To apply the estimated force to a haptic master console for the laparoscopy surgical robot system, the light haptic master console should be designed. This paper suggests the design of lighter master console handle to reduce a weight of the console whose structure can match with the joint and DOF of an instrument. A cable-conduit mechanism is designed to make light structure to perform a delicate manipulation. The cable-conduit mechanism removes the weight and inertia of link caused by haptic actuator and encoder which is separated from handle link of a manipulator.

Measurement of Apnea Using a Polyvinylidene Fluoride Sensor Inserted in the Pillow (베게에 삽입된 PVDF센서를 이용한 무호흡증 측정)

  • Keum, dong-Wi;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.407-413
    • /
    • 2018
  • Most sleep apnea patients exhibit severe snoring, and long-lasting sleep apnea may cause insomnia, hypertension, cardiovascular diseases, stroke, and other diseases. Although polysomnography is the typical sleep diagnostic method to accurately diagnose sleep apnea by measuring a variety of bio-signals that occur during sleep, it is inconvenient as the patient has to sleep with attached electrodes at the hospital for the diagnosis. In this study, a diagnostic pillow is designed to measure respiration, heart rate, and snoring during sleep, using only one polyvinylidene fluoride (PVDF) sensor. A PVDF sensor with piezoelectric properties was inserted into a specially made instrument to extract accurate signals regardless of the posture during sleep. Wavelet analysis was used to identify the extractability and frequency domain signals of respiration, heart rate, and snoring from the signals generated by the PVDF sensor. In particular, to separate the respiratory signal in the 0.2~0.5 Hz frequency region, wavelet analysis was performed after removing 1~2 Hz frequency components. In addition, signals for respiration, heart rate, and snoring were separated from the PVDF sensor signal through a Butterworth filter and median filter based on the information obtained from the wavelet analysis. Moreover, the possibility of measuring sleep apnea from these separated signals was confirmed. To verify the usefulness of this study, data obtained during sleeping was used.