• Title/Summary/Keyword: Separated Crossover

Search Result 13, Processing Time 0.019 seconds

Advanced Genetic Algrorithm Strategies in Optimal Design of Stiffened Composite Panels (보강된 복합재 패널의 최적설계를 위한 유전알고리듬의 연구)

  • Lee, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1193-1202
    • /
    • 2000
  • The paper describes the use of genetic algorithms (GA's) to the minimum weight design of stiffened composite panels for buckling constraints. The proposed design problem is characterized by mixture of continuous and discrete design variables corresponding to panel elements and stacking sequence of laminates, respectively. Design space is multimodal and non-convex, thereby introducing the need for global search strategies. Advanced strategies in GA's such as directed crossover, multistage search and separated crossover are adopted to improve search ability and to save computational resource requirements. The paper explores the effectiveness of genetic algorithms and their advanced strategies in designing stiffened composite panels under various uniaxial compressive load conditions and the linrlit on stacking sequence of laminates.

Nafion-Sulfonated Poly(arylene ether sulfone) Composite Membrane for Direct Methanol Fuel Cell

  • Choi Jisu;Kim II Tae;Kim Sung Chul;Hong Young Taik
    • Macromolecular Research
    • /
    • v.13 no.6
    • /
    • pp.514-520
    • /
    • 2005
  • Composite membranes of Nafion and sulfonated poly(arylene ether sulfone) were prepared. Sulfonated poly(arylene ether sulfone)s with different degrees of sulfonation were blended with Nafion to reduce the methanol crossover. The morphology, proton conductivity and methanol permeability of the resulting composite membranes were investigated by SEM, EDAX, AC impedance spectroscopy and permeability measuring instrument. The cross­sections of the composite membranes showed a phase separated morphology. The morphology and phase separation mechanism could be controlled by varying the blend ratio and the degree of sulfonation of poly(arylene ether sulfone). These complex morphologies can be applied for reducing methanol crossover. The methanol permeability and proton conductivity of the composite membranes were lower than those of Nafion 117 membrane since the development of an ionic pathway in the blend membrane was more difficult than that in Nafion itself.

Transport Properties of Polymer Blend Membranes of Sulfonated and Nonsulfonated Polysulfones for Direct Methanol Fuel Cell Application

  • Kim, Dong-Hwee;Kim, Sung-Chul
    • Macromolecular Research
    • /
    • v.16 no.5
    • /
    • pp.457-466
    • /
    • 2008
  • The relation between the phase separated morphologies and their transport properties in the polymer blend membrane for direct methanol fuel cell application was studied. In order to enhance the proton conductivity and reduce the methanol crossover, sulfonated poly(arylene ether sulfone) copolymer, with a sulfonation of 60 mol% (sPAES-60), was blended with nonsulfonated poly(ether sulfone) copolymer (RH-2000, Solvay). Various morphologies were obtained by varying the drying condition and the concentration of the casting solution (10, 15, 20 wt%). The transport properties of proton and methanol molecule through the polymer blend membranes were studied according to the absorbed water. AC impedance spectroscopy was used to measure the proton conductivity and a liquid permeability measuring instrument was designed to measure the methanol permeability. The state of water in the blend membranes was confirmed by differential scanning calorimetry and was used to correlate the morphology of the membrane with the membrane transport properties.

Measurement of Hydrogen Crossover by Gas Chromatograph in PEMFC (고분자전해질 연료전지에서 기체 크로마토그래프에 의한 수소투과도 측정)

  • Jeong, Jaejin;Jeong, Jaehyeun;Kim, Saehoon;Ahn, Byungki;Ko, Jaijoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.425-429
    • /
    • 2014
  • Until a recent day, degradation of PEMFC MEA(membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. During simultaneous degradation, there was interaction between membrane degradation and electrode degradation. Hydrogen permeability was used often to measure degradation of electrolyte membrane in PEMFC. In case of hydrogen permeability measured by LSV(Linear Sweep Voltammetry) method, the degradation of electrode decrease the value of hydrogen crossover current due to LSV methode's dependence on electrode active area. In this study hydrogen permeability was measured by gas chromatograph(GC) when membrane and electrode degraded at the same time. It was showed that degradation of electrode did not affect the hydrogen permeability measured by GC because of GC methode's independence on electrode active area.

Degradation Accelerated Stress Test of Electrode and Membrane in PEMFC (PEMFC에서 전극과 전해질 막의 열화 가속 시험)

  • Song, Jin-Hoon;Kim, Sae-Hoon;Ahn, Byung-Ki;Ko, Jai-Joon;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.778-782
    • /
    • 2012
  • Until a recent day, degradation of PEMFC MEA (membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. Therefore in this work, AST (Accelerated Stress Test) of MEA degradation was done at the condition that membrane and electrode were degraded simultaneously. There was interaction between membrane degradation and electrode degradation. Membrane degradation reduced the decrease range of catalyst active area by electrode degradation. Electrode degradation reduces increase range of the hydrogen crossover current and FER (Fluoride Emission Rate) by membrane degradation.

A Study on the Structure of Turbulent non-Premixed Oxy-fuel Flame Using CMC Model-based Simulation (CMC 모델 기반 수치해석을 사용한 순산소 난류확산화염 구조 연구)

  • Kim, Jong-Soo;Sreedhara, S.;Huh, Kang-Yeol;Yang, Won
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2008
  • Oxy-fuel flame has a significantly different structure from that of air-fuel flame because of its high temperature. This study is aimed to find out the difference of the oxy-fuel flame structure in order to understand reaction mechanism closely, which is crucial to design real-scale oxy-fuel combustion system. By examining pictures of counterflow flame and LIF images, we found that oxy-fuel flame had two-zone structure: fuel decomposition region and distributed CO oxidation region. In the oxy-fuel flame, OH radical was distributed intensely through the whole flame due to its higher flame temperature than crossover temperature. For showing those features of the oxy-fuel flame, 1 MW scale IFRF oxy-natural gas burner was simulated by conditional moment closure(CMC) model. Calculation results were compared with experimental data, and showed agreements in trend. In the simulated distributions of fuel decomposition/CO oxidation rates, CO oxidation region was also separated from fuel decomposition zone considerably, which showed the two-zone structure in the oxy-fuel flame.

  • PDF

A Techniques for Information Hiding in the Steganography using LSB and Genetic Algorithm (유전적 알고리즘과 LSB를 이용한 스테가노그래피의 정보은닉 기법)

  • Ji, Seon-Su
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.3
    • /
    • pp.277-282
    • /
    • 2018
  • The goal of the secret message communication on the internet is to maintain invisibility and confidentiality. Digital steganography is a technique in which a secret message is inserted in a cover medium and transmitted to a destination so that a third party can not perceive the existence of the message itself. Steganography is an efficient method for ensuring confidentiality and integrity together with encryption techniques. In order to insert a secret (Hangul) message, I propose a image steganography method that the secret character is separated and converted into binary code with reference to the encryption table, the cover image is divided into two areas, and the secret message and the right l-LSB information of the second area are encrypted and crossed, concealing the k-LSB of the first region. The experimental results of the proposed method show that the PSNR value is 52.62 and the acceptable image quality level.

Effect of Electrode Degradation on the Membrane Degradation in PEMFC (PEMFC에서 전극 열화가 전해질 막 열화에 미치는 영향)

  • Song, Jinhoon;Kim, Saehoon;Ahn, Byungki;Ko, Jaijoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.68-72
    • /
    • 2013
  • Until a recent day, degradation of PEMFC MEA (membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. During simultaneous degradation, there was interaction between membrane degradation and electrode degradation. The effect of electrode degradation on membrane degradation was studied in this work. We compared membrane degradation after electrode degradation and membrane degradation without electrode degradation. I-V performance, hydrogen crossover current, fluoride emission rate (FER), impedance and TEM were measured after and before degradation of MEA. Electrode degradation reduced active area of Pt catalyst, and then radical/$H_2O_2$ evolution rate decreased on Pt. Decrease of radical/$H_2O_2$ reduced the velocity of membrane degradation.

A Study on the Phased Cultural Product Design with Characteristics of Unlined Cheollik in Early 17th Century and Baby Typed Doll's Body (17세기 초 홑철릭 유물의 시대특성과 유아형 인형의 체형특성을 응용한 단계별 복식문화상품 디자인 연구)

  • Choi, Jeong
    • Fashion & Textile Research Journal
    • /
    • v.19 no.4
    • /
    • pp.385-399
    • /
    • 2017
  • This study will broaden the application of doll costume product with historical characteristics and the image of unlined cheollik in the $17^{th}$ century period of transition during the Joseon Dynasty. Historical design sources were extracted from old documents and precedent studies. Unlined cheollik of Shin Gyeong-yu, meritorious retainer, were selected as main reference-relic because of various fabric, preserved conditions and definite shape. 'Baby doll' was selected as main model because of consumer preferences and awareness. Design sources from unlined cheollik in the early $17^{th}$ century were about a 1:2 ratio of upper and under parts, removable separated doori-somae, knife-shaped collar (outside), projected square collar (inside), long pleats line, side slit, traditional flat fell seam sewing. Trapezoidal side line, round waistline, and thin fabric were applied in designs because of toddler-body of doll model. Three designs were produced in step 1: Cheollik A focusing on the historical remake (traditional type), Cheollik B with belt and side slit (crossover type), and Cheollik C with back- opening (modern type). In step 2, interview with fashion major student was conducted to increase the utility of designs. As a result, modern trend sources (frill, velcro, round armhole line, slope of sleeves, and floral pattern) were reflected in Cheollik B, C. Finally, three doll cheollik and cheollik-styled doll apron sample were produced. Various versions must be suggested in the study of doll costume products with traditional sources that balance historical characteristics and practicality to improve customer satisfaction.

A clinical comparative study between conventional and camouflaged syringes to evaluate behavior and anxiety in 6-11-year-old children during local anesthesia administration-a novel approach

  • Melwani, Anjana M;Srinivasan, Ila;Setty, Jyothsna V;Murali, Krishna D.R.;Pamnani, Sunaina S;Lalitya, Dandamudi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • Background: The sight of dental injection can bring about severe anxiety in children. Therefore, an alternative method that is convenient, effective, and keeps the needle hidden making it child friendly is necessary. The objective of the study was to compare the efficacy of a camouflaged syringe and conventional syringe on behavior and anxiety in 6-11-year-old children during local anesthesia administration. Methods: The study was a randomized, crossover clinical study including 30 children. Children were separated into two groups. Group 1 consisted of 15 children aged 6-8 years while group 2 consisted of 15 children aged 9-11 years. This study involved two sessions wherein all the children were injected using conventional and camouflaged syringes in separate sessions. Their behavior was assessed using the Faces, Legs, Activity, Cry, Consolability (FLACC) behavior pain scale and anxiety was assessed by measuring changes in pulse rate. Patient and operator preferences were compared. Results: The results showed a lower mean change in pulse rate and FLACC scores in the camouflaged group, suggesting a positive behavior and lesser anxiety with camouflaged syringes than with conventional syringes. Conclusions: The use of camouflaged syringes for anesthesia was demonstrated to be effective in improving the behavior of children and decreasing their anxiety, and is therefore recommended as an alternative to the use of conventional syringes for local anesthesia.