• Title/Summary/Keyword: Separate Dust

Search Result 42, Processing Time 0.032 seconds

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF

Analysis of Vertical Profiles and Optical Characteristics of the Asian Dust Using Ground-based Measurements (지상관측장비를 이용하여 관측한 봄철 황사의 연직분포와 광학적 특성 분석)

  • Lee, Byung-Il;Yoon, Soon-Chang;Kim, Yoonjae
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.287-297
    • /
    • 2008
  • The vertical profiles and optical properties of Asian dust are investigated using ground-based measurements from 1998 to 2002. Vertical profiles of aerosol extinction coefficient are evaluated using MPL (Micro Pulse Lidar) data. Optical parameters such as aerosol optical thickness ($\tau$), ${\AA}ngstr\ddot{o}m$ exponent ($\alpha$), single scattering albedo ($\omega$), refractive index, and volume size distribution are analyzed with sun/sky radiometer data for the same period. We can separate aerosol vertical profiles into three categories. First category named as 'Asian dust case', which aerosol extinction coefficient is larger than $0.15km^{-1}$ and dust layer exists from surface up to 3-4km. Second category named as 'Elevated aerosol case', which aerosol layer exists between 2 and 6km with 1-2.5km thickness, and extinction coefficient is smaller than $0.15km^{-1}$. Third category named as 'Clear sky case', which aerosol extinction coefficient appears smaller than $0.15km^{-1}$. and shows that diurnal variation of background aerosol in urban area. While optical parameters for first category indicate that $\tau$ and $\alpha$ are $0.63{\pm}0.14$, $0.48{\pm}0.19$, respectively. Also, aerosol volume concentration is increased for range of 1 and $4{\mu}m$, in coarse mode. Optical parameters for second category can be separated into two different types. Optical properties of first type are very close to Asian dust cases. Also, dust reports of source region and backward trajectory analyses assure that these type is much related with Asian dust event. However, optical properties of the other type are similar to those of urban aerosol. For clear sky case, $\tau$ is relatively smaller and $\alpha$ is larger compare with other cases. Each case shows distinct characteristics in aerosol optical parameters.

Development of Geochemical Tracers to Identify a Specific Source Region of Mineral Dust in China and Preliminary Test of Their Applicability (중국 기원 광물성 먼지 입자의 지화학 추적자 개발 및 기초 적용연구)

  • Lee, Sojung;Hyeong, Kiseong;Kim, Wonnyon;Kim, Tae-Hoon
    • Ocean and Polar Research
    • /
    • v.41 no.3
    • /
    • pp.169-181
    • /
    • 2019
  • The purpose of this study is to develop geochemical tracers to identify a specific source desert of mineral dust in China using the published data. In addition, we tested the applicability of these tracers to wet-deposits and soil samples collected in Jeju, Korea. Because of similarity in trace elemental compositions of mineral dust from the major arid regions in China, such as Taklimakan, West Ordos (Badain Jaran), East Ordos (Mu Us and Hobq), East Northern China (Horqin), West Northern China (Gurbantunggut), and Chinese Loess Plateau, there has been limited to the use of geochemical data for source identification. Here we propose the four (4) plots using combination of seven (7) geochemical variables as a source indicator to distinguish one from other source regions in China: $\frac{Y}{Tb_N}$ vs. $\frac{Th}{{\Sigma}REE_N}$, $\(\frac{La}{Gd}\)_N$ vs. $\frac{Y}{{\Sigma}REE_N}$, $\frac{Th}{Tb_N}$ vs. $\frac{Y}{Nd_N}$, and $\frac{Th}{Tb_N}$ vs. $\(\frac{Ce}{Ce}\)_N^*$, where $_N$ and $\(\frac{Ce}{Ce}\)_N^*$ stand for values normalized to Post-Archean Average Shale composition and Ce anomaly, respectively. Mineral dusts from aforementioned six major deserts are distinguished one from the others by the combined use of these variables. Jeju rock and soil samples form a separate domain from Chinese mineral dusts in all four plots. In contrast, most of Jeju dust samples were comparable with the West Ordos desert (Badain Jaran) domain, indicative of strong influence of Badain Jaran dust in Jeju in spring season when the mineral dust was collected. A weak positive Ce anomaly in Jeju samples implies minimal local contribution. Our study suggests that the combination of $\frac{Y}{Tb_N}$ vs. $\frac{Th}{{\Sigma}REE_N}$, $\(\frac{La}{Gd}\)_N$ vs. $\frac{Y}{{\Sigma}REE_N}$, $\frac{Th}{Tb_N}$ vs. $\frac{Y}{Nd_N}$, and $\frac{Th}{Tb_N}$ vs. $\(\frac{Ce}{Ce}\)_N^*$ can be used to identify a specific source region of mineral dust in China as well as Jeju mineral particles.

The Implementation of the Fine Dust Measuring System based on Internet of Things(IoT) (사물인터넷기반 미세먼지 측정 시스템 구현)

  • Noh, Jin-Ho;Tack, Han-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.4
    • /
    • pp.829-835
    • /
    • 2017
  • Recently, the health issues triggered by fine dust matters occurred in higher frequency. Having adverse effects on health, particulate matters affect the human body indoors as well as outdoors. There is thus a need for a system to measure the concentration of particulate matters and control harmful particulate matters for human health in the indoor spaces where people live. The present study applied Internet of Things(IoT) technologies in order to increase the efficiency of the conventional fine dust measurement system. Especially, for the bidirectional communication environment, directly construct a separate server and applied to the system instead of a free cloud server also we used it directly in the school lab and home. When the proposed system is used in schools and homes, it can recognize the indoor environment quickly and it is expected that this will gradually contribute to the health of the individual. Users can also check the server data outside and deal with the current indoor situations.

Process Technology of the Direct Separation and Recovery of Iron and Zinc Metals Contained in High Temperature EAF Exhaust Gas

  • Furukawa, Takeshi;Sasamoto, Hirohiko;Isozaki, Shinichi;Tanno, Fumio
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.393-397
    • /
    • 2001
  • The innovatory process, that is the direct separation and recovery of the iron and zinc metals contained in the high temperature exhaust gas generated from the electric arc furnace fer the inn scrap melting and/or the dust treatment, has been proposed. This proposed process consists of the moving coke bed filter that is directly connected to the electric furnace, and the following heavy metal condenser. The exhaust gas passes through the filter and the condenser right after exhausting from the electric furnace. The moving coke bed filter is being controlled at about 1000℃ and collects iron and slag components contained in the high temperature exhaust gas. Heavy metals such as zinc and lead pass through the filter as vapor. Based on the thermodynamic considerations, the iron oxide and the zinc oxide are reduced in the filter. The solution loss reaction rate is comparatively low at about 1000℃ in the coke bed filter by the analysis using the mathematical simulation model. The heavy metal condenser is installed in the position after the coke bed filter, and rapidly cools the gas from about 1000℃ to 450℃ by a full of the cooling medium like the solid ceramic ball in addition to the cooling from the wall. The zinc and lead vapor condense and separate f개m the gas in a liquid state. The investigation of the characteristics of the exhaust gas of the commercial electric arc furnace, the fundamental experiments of the laboratory scale and the bench scale ensured the formation of this proposed process. A small-scale pilot plant examination is carrying out at present to confirm the formation of the process. It is certain that the dust generation of the electric arc furnace is extremely decreased, and it can save the energy consumption of usual dust treatment processes by the realization of this process.

  • PDF

Development of Detection and Monitoring by Light Scattering in Real Time (광산란 방식 실시간 미세먼지 측정 및 모니터링 시스템 개발)

  • Lee, Nuri;Um, Hyun-Uk;Cho, Hyun-Sug
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.134-139
    • /
    • 2018
  • Extremely fine particles seriously affect people and are becoming a social problem. Conventional methods using the type of beta ray absorption are difficult to have real-time measurements and miniaturization for the acquisition of fine dust. In this paper, a light scattering method was used. The sensors were configured internally with semiconductor laser diodes for miniaturization, low cost and lightweight. The use of the FFT method makes it easier to separate fine dust according to size compared to conventional light scattering sensors. Bluetooth communication also allows the connection, monitoring and control of devices using smart phones.

A study on the development of drainage system for rapid drainage of thermal power plant outdoor coal storage during rainfall and characteristics of discharged water quality (강우시 화력발전소 옥외저탄장 신속한 배수를 위한 배수시스템 개발 및 배출 수질 특성에 관한 연구)

  • Lim, Chang-Min;Kwon, Hyun-Woo;Kim, Young-Min;Cho, Do-Young;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.189-190
    • /
    • 2022
  • Power plants that produce electricity through thermal power plants mainly store coal in outdoor storage yards. In particular, coal is directly exposed to rainwater during rainfall, including torrential rain. There is no separate drainage facility in the outdoor coal yard, and coal is simply stored on the ground. Accordingly, during rainfall, coal dust flows down by rainwater, and a large amount of rainwater that is not drained overflows the outdoor coal yard, overflowing the surrounding facilities and causing environmental pollution. Therefore, in this study, a drainage system was developed for the rapid drainage of an outdoor coal mine, and the quality of the water was evaluated when rainwater mixed with drainage characteristics and coal dust was discharged through the drainage system.

  • PDF

A study on the response of environmental sanitation problems in action of the volume based waste charge system (쓰레기 종량제 실시에 따른 환경위생 문제에 관한 조사)

  • 김영환;손종렬;문경환;류재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.35-44
    • /
    • 1995
  • The study was carried out to investigate on the response of environmental sanitation problems in action of the volume based waste charge system in Seoul The responses from the 346 persons who dwelled in Seoul was stimulatively answered, this system was considered as a successful on 70.5% of total answers, but little portion(29.4 % ) of those was unknown on the mean of this system. And we knew that this system was need to the communication and education through the press media about this one. After the action of the volume based waste system, the volume of refuse discharged in a day was decreased 30 ∼40% than before. In the problems of environmental sanitation after this system, the number of sanitary insect( cockroach etc ) and rat was decreased, also the production of orders and dust caused by refuse was decreased in comparison with those before. This results were considered that the Separate Collection should be perfectly performed. In response, the regular envelope of refuse was serious problems, the improvement for this one was demanded. The kind of difficult refuse treated was waste rubbers> electric products > furniture> foodstuffs> bottles, cans> papers, pulps etc, and the next proposal for this system should be prepared. Conclusively, the volume based waste charge system should be remarkable system In terms of resources recycling as well as wastes reduction. Above all in order to conform this system the separate collection system should be systematically performed, the next improvable proposal of the detailed methods in this system should be prepared.

  • PDF

A Study on the Response of Environmental Sanitation Problems in Action of the Volume Based Waste Charge System. (쓰레기 종량제 실시에 따른 환경위생 문제에 관한 조사)

  • 손종렬;문경환;김영환;류재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.82-90
    • /
    • 1998
  • The study was carried out to investigate on the response of environmental sanitation problems in action of the volume based waste charge system in Seoul. The responses from the 396 persons who dwelled in Seoul was stimulatively answered, this system was considered as a successful one 69.6% of total answers, but little portion (21.2%) of those was unknown on the mean of this system. And we knew that this system was need to the communication and education through the press media about this one. After the action of the volume based waste charge system, the volume of refuse discharged in a day was decreased 30-50% than before. In the problems of environmental sanitation after this system, the number of sanitary insect(cockroach etc) and rat was decreased, also the production of order and dust caused by refuse was decreased in comparison with those before. This results were considered that the Separate Collection should be perfectly performed. In response, the regular envelope of refuge was serious problems, the improvement for this one was demanded, The kind of difficult refuse treated was waste foodstuffs> electric products> rubbers> furniture> bottles, cans>papers, pulps etc. and the next proposal for this system should be prepared. Conclusively, the volume based waste charge system should be remarkable system in terms of resources recycling as well as wastes reduction. Above all in order to conform this system the separate collection system should be systematically performed, the next improvable proposal of the detailed methods in this system should be prepared.

  • PDF

The Study of PM10, PM2.5 Mass Extinction Efficiency Characteristics Using LIDAR Data (라이다 데이터를 이용한 PM10, PM2.5 질량소산효율 특성 연구)

  • Kim, TaeGyeong;Joo, Sohee;Kim, Gahyeong;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_2
    • /
    • pp.1793-1801
    • /
    • 2021
  • From 2015 to June 2020, the backscattering coefficients of 532 and 1064 nm measured using LIDAR and the depolarization ratio at 532 nm were used to separate the backscattering coefficient at 532 nm as three types as PM10, PM2.5-10, PM2.5 according to particle size. The mass extinction efficiency (MEE) of three types was calculated using the mass concentration measured on the ground. The overall mean values of the calculated MEE were 5.1 ± 2.5, 1.7 ± 3.7, and 9.3 ± 6.3 m2/g in PM10, PM2.5-10, and PM2.5, respectively. When the mass concentration of PM10 and PM2.5 was low, higher than average MEE was calculated, and it was confirmed that the MEE decreased as the mass concentration increased. When the MEE was calculated for each type according to the mixing degree of Asian dust, PM2.5-10 was twice at pollution aerosol as high as 2.1 ± 2.8 m2/g, compare to pollution-dominated mixture, dust-dominated mixture, and pure dust of 1.1 ± 1.8, 1.4 ± 3.3, 1.1 ± 1.5 m2/g, respectively. However, PM2.5 MEE showed similar values irrespective of type: 9.4 ± 6.5, 9.0 ± 5.8, 10.3 ± 7.5, and 9.1 ± 9.0 m2/g. The MEE of PM10 was 5.6 ± 2.9, 4.4 ± 2.0, 3.6 ± 2.9, and 2.8 ± 2.4 m2/g in pollution aerosol (PA), pollution-dominated mixture (PDM), dust-dominated mixture (DDM), and pure dust (PD), respectively, and increased as the dust ratio value decreased. Even if the same type according to the same mass concentration or Asian dust mixture was shown, as the PM2.5/PM10 ratio decreased, the MEE of PM2.5-10 decreased and the MEE of PM2.5 showed a tendency to increase.