• Title/Summary/Keyword: Seop

Search Result 12,192, Processing Time 0.043 seconds

Evaluation of Groundwater Quality Deterioration using the Hydrogeochemical Characteristics of Shallow Portable Groundwater in an Agricultural Area (수리지화학적 특성 분석을 이용한 농촌 마을 천부 음용지하수의 수질 저하 원인 분석)

  • Yang, Jae Ha;Kim, Hyun Koo;Kim, Moon Su;Lee, Min Kyeong;Shin, In Kyu;Park, Sun Hwa;Kim, Hyoung Seop;Ju, Byoung Kyu;Kim, Dong Su;Kim, Tae Seung
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.533-545
    • /
    • 2015
  • Spatial and seasonal variations in hydrogeochemical characteristics and the factors affecting the deterioration in quality of shallow portable groundwater in an agricultural area are examined. The aquifer consists of (from the surface to depth) agricultural soil, weathered soil, weathered rock, and bedrock. The geochemical signatures of the shallow groundwater are mostly affected by the NO3 and Cl contaminants that show a gradual downward increase in concentration from the upper area, due to the irregular distribution of contamination sources. The concentrations of the major cations do not varied with the elapsed time and the NO3 and Cl ions, when compared with concentrations in background groundwater, increase gradually with the distance from the upper area. This result suggests that the water quality in shallow groundwater deteriorates due to contaminant sources at the surface. The contaminations of the major contaminants in groundwater show a positive linear relationship with electrical conductivity, indicating the deterioration in water quality is related to the effects of the contaminants. The relationships between contaminant concentrations, as inferred from the ternary plots, show the contaminant concentrations in organic fertilizer are positively related to concentrations of NO3, Cl, and SO42− ions in the shallow portable groundwaters, which means the fertilizer is the main contaminant source. The results also show that the deterioration in shallow groundwater quality is caused mainly by NO3 and Cl derived from organic fertilizer with additional SO42− contaminant from livestock wastes. Even though the concentrations of the contaminants within the shallow groundwaters and the contaminant sources are largely variable, it is useful to consider the ratio of contaminant concentrations and the relationship between contaminants in groundwater samples and in the contaminant source when analyzing deterioration in water quality.

Virus Inactivation Processes for the Manufacture of Human Acellular Dermal Matrix (인체이식용 무세포 진피 제조를 위한 바이러스 불활화 공정)

  • Bae, Jung-Eun;Kim, Jin-Young;Ahn, Jae-Hyoung;Choi, Da-Mi;Jeong, Hyo-Sun;Lee, Dong-Hyuck;Kim, In-Seop
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.2
    • /
    • pp.168-176
    • /
    • 2010
  • Acellular dermal matrix (ADM), produced by decellularization from human cadaveric skin, has been used for various biomedical applications. A manufacturing process for ADM ($SureDerm^{TM}$) using tri-n-butyl phospahate (TnBP) and deoxycholic acids as the decellularization solution has been developed. The manufacturing process for $SureDerm^{TM}$ has 70% ethanol treatment and ethylene oxide gas sterilization for inactivating infectious microorganisms. The purpose of this study was to examine the efficacy of the 70% ethanol treatment, decellularization process using 0.1% TnBP and 2% deoxycholic acids, and EO gas sterilization process in the inactivation of viruses. A variety of experimental model viruses for human pathogens, including the human immunodeficiency virus type 1 (HIV-1), bovine herpes virus (BHV), bovine viral diarrhoea virus (BVDV), hepatitis A virus (HAV), and porcine parvovirus (PPV) were all selected for this study. Enveloped viruses such as HIV-1, BHV, and BVDV were effectively inactivated to undetectable levels by 70% ethanol treatment. However HAV and PPV showed high resistance to 70% ethanol treatment with the log reduction factors of 1.85 and 1.15, respectively. HIV-1, BHV, and BVDV were effectively inactivated to undetectable levels by decellularization process. All the viruses tested were completely inactivated to undetectable levels by EO gas treatment. The cumulative log reduction factors of HIV-1, BHV, BVDV, HAV, and PPV were $\geq12.71$, $\geq18.08$, $\geq14.92$, $\geq6.57$, and $\geq7.18$, respectively. These results indicate that the production process for $SureDerm^{TM}$ has a sufficient virus-reducing capacity to achieve a high margin of the virus safety.

Comparison of the Ambiguous Advertising Messages Effect with Clear Advertising Messages (모호한 광고와 명료한 광고의 메시지효과 비교)

  • Lee, Hyun-Woo;Oh, Chang-Il;Cho, Kyoung-Seop
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.129-138
    • /
    • 2005
  • It has been assumed that the clarification of a message is a necessary element for successful communication. However, in the today's complicated and changing environment of business marketing media, it is shown that the clarification of the message of advertisement may inhibit the effectiveness of communication. This study was to examine what was effective communication in advertisement when the company, provoking the people's negative emotional response, needs to establish new identities such as the goals and the special fields of business. In particular, the study was to investigate what effect the advertising strategy of strategically emitting ambiguous messages makes on the consumer's recognition, emotional attitude, reliability, and attitude towards the company. It was hypothesized that an ambiguous message in an advertisement has an effect on the consumer's recognition, emotional attitude, reliability, and attitude towards the company. Three texts from the 'Imagination Praises' campaign of KT&G which has been in process since 2003 were systematically sampled and the survey was performed by the means of questionnaires made on the sample The results showed that the ambiguous message of advertising texts gained better responses on the consumer's attention, good impression, affirmation, memory, sympathy than the dear message and that the ambiguous message had an effect on the consumer's attitude towards the advertisement itself. Thus, it could be tentatively concluded that the ambiguous message could be more effective in recognition and recall to promote the changes of identities of the company having the people's unfavorable emotion. But there wasn't any evidence that an ambiguous message in an advertisement was more effective in terms of the consumer's emotional response, reliability, and attitude towards the company. From this, it could be inferred that the receiver had an uncomfortable, doubtful and negative attitude about the implicit expressive code contained in the message. In the future deeper qualitative studies can compensate for the limited explanation of this empirical study focused on statistical analyses.

  • PDF

Consideration about LINAC movable range by H&N patient immobilization device manufacture (두경부환자 고정기구제작을 통한치료기 가동범위에 관한 고찰)

  • Jung DoHyung;Shim JinSeop;Youm DuSeok;Choi GyeSuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.63-67
    • /
    • 2004
  • Purpose : New therapy technique appeared in 3D-CRT or IMRT according to a radiation treatment developing and worked. Such treatment technique requires the radiation irradiation of many direction. It has many restriction at radiation irradiation of many direction to the linear acceleration deception of now actually. Consequently We make new fix device and measure consequently the improvement of the activate range. Method and Material : We upload the fix device on a linear accelerator Couch. We fixed Gantry at 45, 90, 135 and Couch is spin and measure the clearance of the equipment. Couch is fixed at 0 45 90 and measures the clearance of Gantry. We upload the Extended head holder(EHH) on a linear accelerator Couch. and We measure with the experiment of the front. Result : The action range did not have big difference to increase Gantry45. but The activate range of Couch increases the angle in Gantry 90 and Gantry 135 when it uses EHH. The activate range of Gantry increases the angle in Couch 45 when it uses EHH. We showed good activate situation all in Couch 0 and Couch 90. The utility of EHH could keep a behind radiation diminution. Conclusion : The radiation irradiation of many direction comes to be possible the utility of the fix instrument(EHH). The safety space between the patient and equipment or between equipment and equipment increased the utility of the fix device. Also, The manufacture is possible imports to rather cheap price. and We could bring the frugality of the treatment expendable supplies.

  • PDF

Evaluation of biological treatment of cutting-oil wastes using sequencing batch reactor (SBR) process (연속 회분식 반응조 (SBR) 공정을 이용한 폐절삭유의 생물학적 처리능 평가)

  • Baek, Byung-Do;Kim, Chang-Seop;Kim, Jun-Young;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1654-1660
    • /
    • 2009
  • Two different cutting-oils from H and B companies which are sold as an eco-friendly cutting-oils were selected and the biodegradability of these commercially available cutting-oils was evaluated by the sequencing batch reactor (SBR) processes. The cutting-oil wastes ($H_1$) pre-treated by coagulation/flocculation was used as an influent to SBR. When the F/M ratio was operated 0.04 to 0.08kgCOD/kgMLSS d, removals of $BOD_5$and $COD_{Cr}$were above 97% and 91%, respectively. T-N and T-P removals were above 76% and 81%, respectively. If the diluted cutting-oil wastes ($B_1$) was used as an influent of the SBR, $COD_{Cr}$removals were above 77% at the F/M ratio of 0.01-0.02kgCOD/kgMLSS d. After the cutting-oil wastes was treated by coagulation/ flocculation ($B_2$), $COD_{Cr}$removals was above 85%. If the pre-treated cutting-oil wastes were mixed with a synthetic wastewater ($B_3$) and fed into the SBR in order to mimic the real wastewater treatment plant situation, $BOD_5$and $COD_{Cr}$removals were above 97%, 91%, respectively. T-N and T-P removals were above 79% and 76%. The ratio between $BOD_5$and $COD_{Cr}$, ($COD_{Cr}$-$BOD_5$)/$COD_{Cr}$, indicating the biodegradability of effluent of the SBR, was calculated to 85% and 61%. This means that significant amounts of non-readily-biodegradable organic compounds in the effluent of $H_1$, $B_3$are still present.

Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections (콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능)

  • Park, Chang-Hee;Lee, Cheol-Ho;Park, Hong-Gun;Hwang, Hyeon-Jong;Lee, Chang-Nam;Kim, Hyoung-Seop;Kim, Sung-Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.503-514
    • /
    • 2011
  • In this research, the seismic connection details for two concrete-filled U-shape steel beam-to-H columns were proposed and cyclically tested under a full-scale cruciform configuration. The key connecting components included the U-shape steel section (450 and 550 mm deep for specimens A and B, respectively), a concrete floor slab with a ribbed deck (165 mm deep for both specimens), welded couplers and rebars for negative moment transfer, and shear studs for full composite action and strengthening plates. Considering the unique constructional nature of the proposed connection, the critical limit states, such as the weld fracture, anchorage failure of the welded coupler, local buckling, concrete crushing, and rebar buckling, were carefully addressed in the specimen design. The test results showed that the connection details and design methods proposed in this study can well control the critical limit states mentioned above. Especially, the proposed connection according to the strengthening strategy successfully pushed the plastic hinge to the tip of the strengthened zone, as intended in the design, and was very effective in protecting the more vulnerable beam-to-column welded joint. The maximum story drift capacities of 6.0 and 6.8% radians were achieved in specimens A and B, respectively, thus far exceeding the minimumlimit of 4% radians required of special moment frames. Low-cycle fatigue fracture across the beam bottom flange at a 6% drift level was the final failure mode of specimen A. Specimen B failed through the fracture of the top splice plate of the bolted splice at a very high drift ratio of 8.0% radian.

Effect of Annual Ring Angles on Static Bending Strength Performances of Cross-Laminated Woods Made with Spruce (연륜경사각이 가문비나무 직교형적층재의 정적 휨 강도성능에 미치는 영향)

  • Sung, Eun-Jong;Kwon, Chang-Bae;Ryu, Hyun-Soo;Byeon, Hee-Seop;Park, Han-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.290-300
    • /
    • 2014
  • In this study, cross-laminated woods were made with spruce wood and the effects of annual ring angles of perpendicular direction laminae on static bending strength performance were investigated. Static bending strength performances of parallel laminated woods with all layers composed of laminae perpendicular to the grain ($P_{\bot}$ type) were in the order of $90^{\circ}$ > $0^{\circ}$ > $45^{\circ}$. The MOE and MOR for the $45^{\circ}$ annual ring angle were 0.0989 GPa and 3.25 MPa, and it showed the lowest values. By placing longitudinal-direction laminae in the core of $P_{\bot}$ type, the strength performances were markedly improved. In the case of cross-laminated woods with perpendicular-direction laminae in the faces ($C_{\bot}$ type), the bending strength performances were in the order of $90^{\circ}$ > $0^{\circ}$ > $45^{\circ}$, but the differences among annual ring angles were less than those of the parallel-laminated woods. In the case of cross-laminated woods with perpendicular-direction laminae in the core ($C_{\parallel}$ type), the bending strength performances were in the order of $45^{\circ}$ > $90^{\circ}$ > $0^{\circ}$ unlike $P_{\bot}$ type and $C_{\bot}$ type. The MOE and MOR for the $45^{\circ}$ annual ring angle were 12.0 GPa and 55.8 MPa, and it showed the highest values.

Acute Renal Failure after On-pump Coronary Artery Bypass Surgery (체외순환하 시행한 관상동맥우회술 후 발생한 급성신부전증)

  • Jin, Ung;Jo, Min-Seop;Park, Chan-Beom;Sa, Young-Jo;Kim, Chi-Kyung
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.416-422
    • /
    • 2004
  • Acute renal failure (ARF) is a common postoperative complication after the cardiac surgery. Postoperative ARF have various causes, and are combined with other complications rather than being the only a complication. It deteriorates the general condition of the patient, and makes it difficult to manage the combined complications by disturbing the adequate medication and fluid therapy. We have planned this study to evaluate the effects of postoperative ARF after the on-pump coronary artery bypass surgery (CABG) on the recovery of patients and identify the risk factors. Method and Material: We reviewed the medical records of patients who underwent CABG with cardiopulmonary bypass by a single surgeon from Jan. 2000 to Dec. 2002, We checked the preoperative factors; sex, age, history of previous serum creationism over 2.0 mg/㎗, preoperatively last checked serum creatinine, diabetes, hypertension, left ventricular ejection fraction, intraoperative factors; whether the operation is an emergent case or not, cardiopulmonary bypass time, aortic cross clamp time, the number of distal anastomosis, postoperative factors: IABP. Then we have studied the relations of these factors and the cases of postoperative peak serum creatinine over 2.0 mg/㎗. Result: There were 19 cases with postoperative peak serum creatinine over 2.0 mg/㎗ in a total 97 cases. Dialysis were done in 3 cases for ARF with pulmonary edema and severely reduced urine output. There were 8 cases (42.1%) with combined complications among the 19 patients. This finding showed a significant difference from the 5 cases (6,4%) in the patients whose creatinine level have not increased over 2.0 mg/㎗. The mortalities are different as 1.3% to 10.5%. The risk factors that are related with postoperative serum creatinine increment over 2.0 mg/㎗ are diabetes, the history of previous serum creatinine over 2.0 mg/㎗ and left ventricular ejection fraction. Conclusion: Postoperative ARF after the on-pump CABG is related with preoperative diabetes, the history of previous serum creatinine over 2,0 mg/㎗ and left ventricular ejection fraction. Postoperative ARF could De the reason for increased rate of complications and mortality after on-pump CABG. Therefore, in the patients with these risk factors, the efforts to prevent postoperative ARF like off-pump CABG should be considered.

Clinical Experiences of Congenital Aortic Stenosis (선천성 대동맥 판막협착증의 임상 경험)

  • Jeong, Dong-Seop;Ra, Yong-Joon;Lee, Jeong-Ryul;Kim, Yong-Jin;Lee, Chang-Ha;Lee, Cheul;Lim, Hong-Gook;Hwang, Seong-Wook;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.17-24
    • /
    • 2007
  • Background: The aim of this study is to assess the clinical results of various procedures in congenital aortic stenosis. Material and Method: From August 1987 to June 2004, 53 patients of congenital aortic stenosis underwent procedures such as percutaneous balloon valvuloplasty, aortic valvuloplasty, Ross procedure, and aortic valve replacement. The mean age of initial procedures was $8.2{\pm}6.0$ years. Percutaneous balloon valvuloplasty was peformed in sixteen patients, aortic valvulopiasty in thirty two patients, Ross procedure in nineteen patients, and aortic valve replacement in fourteen patients. The mean follow duration was $80.6{\pm}60\;(0{\sim}207)$ months. Result: There was 15.1% (8/53) of early mortality and no late mortality. The six patients with critical aortic stenosis were died of left ventricular dysfunction in early series (before 1 year; 4 cases) and two patients died after the Ross procedure and aortic valve replacement respectively. After percutaneous balloon valvuloplasty, most patients needed reoperations (14/16). Thirteen patients needed reoperation, after aortic valvuloplasty. After Ross procedure, two patients needed reoperation due to aortic regurgitation caused by progressive aortic root dilatation. The actuarial survival rate after Ross procedure at 7 years was 90.5%. Conclusion: In young children before the age of one, percutaneous balloon valvuloplasty was considered as :he safe initial palliative procedure. But children over one year-old, aortic valvuloplasty were the effective procedure. Ross procedure can be preformed safely with good results.

Clinical Result of Aortic Arch Replacement using Antegrade Brain Perfusion Via Right Axillary Artery (우액와동맥을 통한 순행성 뇌관류법을 이용한 대동맥궁 치환의 임상성적)

  • Kim, Dong-Jin;Na, Yong-Jun;Jeong, Dong-Seop;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.25-31
    • /
    • 2007
  • Background: Cerebral protection is one of the most important procedures during aortic arch surgery. We can minimize neurological complications through short period of total circulatory arrest and resuming of brain perfusion. We evaluated 11 patients who underwent arch replacement using antegrade brain perfusion via right axillary artery. Material and Method: Between July 2004 and July 2006, 11 patients (male 9, female 2) underwent aortic arch replacement with antegrade brain perfusion via right axillary artery. Preoperative diagnosis was listed; 5 type A aortic dissections (5/11, 45.5%), 5 aortic aneurysms (5/11, 45,5%) and 1 type A IMH (intramural hematoma, 1/11, 9%). The mean age at the time of operation was $60.3{\pm}12.8$ years. For antegrade brain perfusion, we performed right axillary artery cannulation in all patients. Retrograde brain perfusion was used briefly during total circulatory arrest. Result: The mean total circulatory arrest time was $31.1{\pm}16.9$ minutes and the mean retrograde brain perfusion time was $21{\pm}17.8$ minutes. Mean antegrade brain perfusion time was $77.9{\pm}17.5\;(43{\sim}101)$ minutes. We had neither operative mortality nor permanent neurological complications. Conclusion: By means of antegrade brain perfusion via right axillary artery, that could lead to decrease circulatory arrest time and minimize damages to severely atheromatous arch vessels, we can expect to reduce neurological complications after aortic arch replacement. Further investigation with iarge patient populations will be required.