• Title/Summary/Keyword: Sensory Transfer

Search Result 58, Processing Time 0.029 seconds

Production of a Mozzarella Cheese Analogue by Using Raw Milk and Soy Milk Blends (원유를 두유에 첨가한 혼합액으로 Mozzarella Cheese Analogue 제조에 관한 연구)

  • Lee, Joon-Ha;Song, Kwang-Young;Seo, Kun-Ho;Yoon, Yoh-Chang
    • Journal of Dairy Science and Biotechnology
    • /
    • v.31 no.1
    • /
    • pp.9-20
    • /
    • 2013
  • The study was conducted to evaluate the feasibility of Mozzarella cheese analogue generation by using a mixture of soy milk and raw milk and to compare the quality of the resultant cheese with that of Mozzarella cheese manufactured using the traditional method. The mixtures showed increase in protein and decrease in lactose and SNF in a dose-dependent manner with the addition of soy milk. The Mozzarella cheese analogue had lower total solids content than the control cheese product, while the fat content was similar between both. The analogue cheese had lower ash content than the traditionally prepared cheese; the content was proportional to the amount of soy milk in the mixture. Higher soy milk quantities within mixtures also resulted in proportionally higher levels of fat content within analogue cheese. Water-soluble nitrogen content was lower in the analogue cheese than in the control cheese. While the WSN level increased in the control cheese, it was almost constant in the analogue cheese. The control cheese had much higher actual and predicted yield than the analogue cheese, while the analogue cheese had a higher stability level. The control cheese had a higher transfer rate than the analogue cheese, with the exception of lactose. Electrophoresis analysis showed bands for Mozzarella cheese analogues that were present in addition to the normal ${\alpha}$-casein and ${\beta}$-casein bands. Physical characteristic analysis showed that hardness was affected by the addition of soy milk to cheese, while cohesiveness and brittleness were affected by the addition of raw milk, and elasticity was barely affected by milk composition. The meltability of the control cheese was higher than that of the analogue cheese and increased during 30 days of storage at $4^{\circ}C$. Browning, oiling-off, and stretching characteristics were almost identical between the 2 types of cheeses. Sensory evaluation findings showed that the control cheese had much better body texture, appearance, and flavor than the analogue cheese.

  • PDF

The Reconstruction of Foot using Medial Plantar Flap (내측 족저 피판을 이용한 족부의 재건)

  • Chung, Duke-Whan;Lee, Jae-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.2
    • /
    • pp.153-161
    • /
    • 2002
  • Purpose : Plantar surfaces, calcaneal area, and region of Achilles insertion, which are extremely related with weight-bearing area and shoes application, must be reconstructed with glabrous and strong fibrous skin. Numerous methods of reconstructing defects of these regions have been advocated, but the transfer of similar local tissue as a cutaneous flap with preservation of sensory potential would best serve the functional needs of the weight-bearing and non-weight-bearing surfaces of this region. Therefore it is recommended to use the limited skin of medial surface of foot that is similar to plantar region and non-weight-bearing area. In this paper we performed the medial plantar flap transfered as a fasciocutaneous island as one alterative for moderate-sized defects of the plantar forefoot, plantar heel, and area around the ankle in 25 cases and report the result, availability and problem of medial plantar flap. Materials and methods : We performed proximally based medial plantar flap in 22 cases and reverse flow island flap in 3 cases. Average age was $36.5(4{\sim}70)$ years and female was 3 cases. The causes of soft tissue defect were crushing injury on foot 4 cases, small bony exposure at lower leg 1 case, posterior heel defect with exposure of calcaneus 8 cases, severe sore at heel 2 cases, skin necrosis after trauma on posterior foot 4 cases, and defect on insertion area of Achilles tendon 6cases. Average follow up duration was 1.8(7 months-9.5 years) years. Results: Medial plantar flaps was successful in 22 patients. 18 patients preserved cutaneous branches of medial plantar nerve had sensation on transfered flap but diminished sensation or dysesthesia. At the follow up, we found there were no skin ulceration, recurrence of defect or skin breakdown in all 18 patients. But there was one case which occurred skin ulceration postoperatively among another 4 cases not contained medial plantar nerve. At the last follow up, all patients complained diminished sensation and paresthesia at medial plantar area distally to donor site, expecially with 4 patients having severe pain and discomfort during long-time walking. Conclusion : Medial plantar island flap based on medial plantar neurovascualr pedicle have low failure rate with strong fibrous skin and preserve sensibility of flap, so that it is useful method to reconstruct the skin and soft tissue defect of foot. But it should be emphasized that there are some complications such like pain and paresthesia by neuropraxia or injury of medial plantar nerve at more distal area than donor site. We may consider that medial plantar flap have limited flap size and small arc of rotation, and require skin graft closure of the donor defect and must chose this flap deliberately.

  • PDF

Temperature Distribution in Water Cascading Horizontal Retort (열수식 살균기의 온도 분포에 관한 연구)

  • Chung, Myong-Soo;Ahn, Tae-Hoe;Lee, Yong-Gab;Yoo, Moo-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.827-833
    • /
    • 1995
  • Temperature distribution tests for a water cascading horizontal retort utilizing superheated water with overpressure as a heating medium were carried out under three different loading conditions, that is, empty(P-0), half-fully(P-3000) and fully(P-6000) loaded operating conditions. Tank volume and full loading capacity of sterilizer used for this study were about 5,900 liter and 1,140 kg(6000 pouches having 190 g weight each), respectively. Set point condition for sterilization was $122^{\circ}C$, 23 minutes and pressure was maintained in the range of $1.8{\sim}2.0\;kg/cm^2$ during sterilization. For each experiment, time-temperature data and F values were obtained from temperature microprocessor($F_0$ monitor). There were significant variations in the temperature distribution at different positions in the sterilizer. The temperature distribution was also affected by the pouch loading condition significantly. The application of the temperature distribution test to a product (retort pouched curry sauce) was conducted at the fully(P-6000) loading condition. Although heat transfer parameters($f_h\;and\;f_c$), and F values were varied with the position of sterilizer, sensory evaluation showed that the temperature distribution of the sterilizer used in this study didn't affect the quality of retorted curry sauce.

  • PDF

Effect of Dietary Organic or Inorganic Minerals (Selenium and Copper) on Layer's Production and Their Transfer into the Egg (사료 내 유기태 및 무기태 미네랄(셀레늄, 구리)의 수준별 첨가가 산란계의 생산성과 계란 내 이행에 미치는 영향)

  • Park, T.S.;Kim, J.Y.;You, S.J.;Lee, B.K.;Kim, J.M.;Kim, E.J.;Ahn, B.K.;Kang, C.W.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.2
    • /
    • pp.103-110
    • /
    • 2009
  • This experiment was conducted using 350 Lohmann Brown layers (67 weeks of age) to evaluate the dietary effect of organic or inorganic Se and Cu on their contents in chicken eggs. The layers were divided into seven groups and fed a commercial diet or one of the six experimental diets containing different levels of Se and Cu (T1, 0.3ppm organic Se; T2, 1.0ppm organic Se; T3, 1.0ppm inorganic Se; T4, 125ppm organic Cu; T5, 250ppm organic Cu; and T6, 250ppm inorganic Cu) for 5 weeks. No significant differences were observed in egg production and its qualities among groups. The contents of blood cholesterol in the birds fed various levels of Se and Cu were not significantly different as compared to control. Se contents in eggs were linearly increased as dietary Se levels increased for both sources, but Se contents from the groups fed organic Se were slightly higher than those fed inorganic Se. Sensory characteristics of eggs were not influenced by dietary treatments. In conclusion, Se contents in eggs were linearly increased as dietary levels of organic or inorganic Se increased, but eggs in layers fed the diet containing organic Se did not show higher Se contents than those in birds fed dietary inorganic Se.

Inhibition of Microbial Growth in Cabbage-Kimchi by Heat Treatment and Nisin·Yucca Extract (열처리 및 나이신·유카추출물 첨가에 의한 김치의 미생물 증식 저해)

  • Kim, Ji-Sun;Kim, Yu-Jin;Park, Jung-Mi;Kim, Tae-Jip;Kim, Beom-Soo;Kim, Yeon-Mi;Kim, Hye-Rim;Han, Nam-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.11
    • /
    • pp.1678-1683
    • /
    • 2010
  • For extension of storage period of cabbage-kimchi, effects of heat treatment as well as nisin or yucca extract were examined on the growth of microbes. Firstly, when kimchi was heated at various temperatures in polyethylene plastic bottle or membrane pouch, the optimum inhibitory condition giving no sensory change was at $80^{\circ}C$ for 30 min in a plastic membrane pouch and this treatment made a reduction of $0.3\;log_{10}CFU/g$ in total microbes. The result showed that use of plastic bottle was inefficient due to low heat transfer rate. Interestingly, pasteurization of seasoning pastes at $80^{\circ}C$ for 30 min separately from cabbage resulted in better inhibitory effect reducing $0.5\;log_{10}CFU/g$ of total bacteria and $1.0\;log_{10}CFU/g$ of lactic acid bacteria, and this operation was regarded as a promising inhibitory method. Secondly, when nisin and yucca extract were separately added in kimchi, microbial growth was inhibited during storage period and their inhibition effects were enhanced at lower temperature.

Scapular Free Flap (유리 견갑 피판 이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Yim, Chang-Moo
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.24-34
    • /
    • 1996
  • There are many kinds of free flaps for management of extensive soft tissue defect of extremities in orthopaedic field. Free vascularized scapular flap is one of the most useful and relatively easy to application. This flap has been utilize clinically from early eighties by many microsurgical pioneers. Authors performed 102 cases of this flap from 1984 to 1995. We have to consider about the surgical anatomy of the flap, technique of the donor harvesting procedures, vascular varieties and anatomical abnormalities and success rate and the weak points of the procedure. This flap nourished by cutaneous branches from circumflex scapular vessels emerges from the lateral aspect of the subscapular artery 2.5-5cm from its lateral origin passing through the triangular space(bounded by subscapularis, teres minor, teres major, long head of triceps). The terminal cutaneous branch runs posteriorly around the lateral border of the scapular and divided into two major branches, those transeverse horizontally and obliquely to the fascial plane of overlying skin of the scapular body. We can utilize these arteries for scapular and parascapular flap. The vascular pedicle ranged from 5 to 10 cm long depends on the dissection, usually two venae comitantes accompanied circumflex scapular artery and its major branches. The diameter of the circumflex scapular artery is more than 1mm in adult, rare vascular variation. Surgical techniques : The scapular flap can be dissected conveniently with prone or lateral decubitus position, prone position is more easier in my experience. There are two kinds of surgical approaches, most of the surgeon prefer elevation of the flap from its outer border towards its base which known easier and quicker, but I prefer elevation of the flap from its outer border because of the lowering the possibilities of damage to vasculature in the flap itself which runs just underneath the subcutaneous tissue of the flap and provide more quicker elevation of the flap with blunt finger dissection after secure pedicle dissection and confirmed the course from the base of the pedicle. There are minimal donor site morbidity with direct skin closure if the flap size is not so larger than 10cm width. This flap has versatility in the design of the flap shape and size, if we need more longer and larger one, we can use parascapular flap or both. Even more, the flap can be used with latissimus dorsi musculocutaneous flap and serratus anterior flap which have common vascular pedicle from subscapular artery, some instance can combined with osteocutaneous flap if we include the lateral border of the scapular bone or parts of the ribs with serratus anterior. The most important shortcoming of the scapular free flap is non sensating, there are no reasonable sensory nerves to the flap to anastomose with recipient site nerve. Results : Among our 102 cases, overall success rate was 89%, most of the causes of the failure was recipient site vascular problems such as damaged recipient arterial conditions, and there were two cases of vascular anomalies in our series. Patients ages from 3 years old to 62 years old. Six cases of combined flap with latissimus dorsi, 4 cases of osteocutaneous flap for bone reconstruction, 62 parascapular flap was performed - we prefer parascapular flap to scapular. Statistical analysis of the size of the flap has less meaningful because of the flap has great versatility in size. In the length of the pedicle depends on the recipient site condition, we can adjust the pedicle length. The longest vascular pedicle was 14 cm in length from the axillary artery to the enter point cutaneous tissue. In conclusion, scapular free flap is one of the most useful modalities to manage the large intractable soft tissue defect. It has almost constant vascular pedicle with rare anatomical variation, easy to dissect great versatility in size and shape, low donor morbidity, thin and hairless skin.

  • PDF

Monitoring of Aflatoxins in Medicinal Herbs (유통 생약재의 아플라톡신 모니터링)

  • Kim, Yong-Hoon;Kang, Han-Saem;Oh, Sun-Woo;Lee, Hwa-Jung;Kim, Mi-Gyeong;Chung, So-Young;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Lee, Ji-Won;Kim, Young-Seon;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.27-32
    • /
    • 2010
  • This study was conducted to monitor aflatoxins in various medicinal herbs, providing available data for the safety of those products. To monitor aflatoxins in medicinal herbs, a total of 400 samples of 40 different herbs were collected in commercial retailers in Seoul, Daejeon, Gwangju, Daegu, and Busan from March to August, 2008. The samples that passed the sensory evaluation were tested for aflatoxins. Aflatoxins in samples were analyzed by HPLC-florescence coupled with photochemical enhancement. Samples were extracted with 70% methanol and then diluted to the appropriate concentration. A refining process was performed using an immunoaffinity column. The analytical method used in this study was validated. The $R^2$ value for aflatoxin $B_1$ was 0.99946, and the detection range was from 0.25 to 10.0 ng/mL. The accuracy of the analysis was ranged from 83.2% to 101.8%. The relative standard deviation (RSD) in the aflatoxin $B_1$ analysis was 3.4%, demonstrating the precision of this method. In addition, the detection limit and quantitative analysis limit of aflatoxin $B_1$ was $0.53\;{\mu}g/kg$ and $1.76\;{\mu}g/kg$, respectively. These results indicated that the analytical method used in this study was appropriate. The results of HPLC showed that 1% (4 samples) of the samples may contain aflatoxins. The concentration of quantified aflatoxin was $2.3\;{\mu}g/kg$ for both Quisqualis fructus and Remotiflori radix samples. The other samples were below the limit of quantification. Moreover, the concentration of aflatoxin $B_1$ which is made by specific fungi were below the level of regulation. Only 20% of aflatoxin $B_1$ were transferred to hot water. Therefore, the levels of aflatoxins in medicinal herbs were considered to be safe especially considering the aflatoxin transfer ratio.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF