• 제목/요약/키워드: Sensor wire

검색결과 397건 처리시간 0.026초

이중보온관 부식감지선의 응력부식파괴에 관한 연구 (A study on Stress Corrosion Cracking of Sensor Wire in Thermally Insulated Underground Pipeline)

  • 최윤제;김정구
    • 한국재료학회지
    • /
    • 제12권2호
    • /
    • pp.103-111
    • /
    • 2002
  • The thermally insulated underground pipelines have been used for district heating system. The sensor wire embedded in the insulation was used for monitoring the insulating resistance between the sensor wire and the pipe. The resistance measurement system detects corrosion of steel pipe under insulation. The corrosion and stress corrosion cracking(SCC) characteristics of sensor wire in synthetic ground water were investigated using the electrochemical methods and constant load SCC tests. The polarization tests were used to study the electrochemical behavior of sensor wire. The sensor wire was passivated at temperatures ranging from 25 to $95^{\circ}C$. However, the applied sensing current larger than passive current resulted in breakdown of passive film. The constant load SCC tests were performed to investigate the effects of applied current and load on the fracture behavior. Stress-corrosion cracks initiated at pits that were produced by sensing current. The growth of the pit involves a tunnelling mechanism, which leads to ductile fracture.

다수의 분할된 긴 열선과 짧은 열선을 갖는 새로운 비정상열선법 센서개발 (Development of a New Sensor with Divided Multiple Long and Short Wires in Transient Hot-wire Technique)

  • 이신표;이명훈
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.510-517
    • /
    • 2004
  • A fine hot-wire is used both as a heating element and a temperature sensor in transient hot-wire method. The traditional sensor system is unnecessarily big so that it takes large fluid volume to measure the thermal conductivity. To dramatically reduce this fluid volume, a new sensor fabrication and a data processing method are proposed in this article. Contrast to the conventional and most popular two wire sensor, the new sensor system is made up of divided multiple long and short wires. Through validation experiments, it is found that the measured thermal conductivities of the glycerin are exactly same each other between the conventional and proposed new method. Also some technical considerations in arranging the multiple wires are briefly discussed.

나노유체의 열전도율 측정을 위한 새로운 비정상열선법 센서설계와 자료처리방법 (Development of a New Sensor and Data Processing Method in Transient Hot-wire Technique for Nanofluid)

  • 이신표;이명훈;김민태;오제명
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.210-215
    • /
    • 2003
  • A fine hot-wire is used both as a heating element and a temperature sensor in transient hot-wire method. The traditional sensor system is unnecessarily big so that it takes large fluid volume to measure the thermal conductivity. To dramatically reduce this fluid volume, a new sensor fabrication and a data processing method are proposed in this article. Contrast to the conventional and most popular two wire sensor, the new sensor system is made up of divided multiple long and short wires. Through validation experiments, it is found that the measured thermal conductivities of the glycerin are exactly same each other between the conventional and proposed new method. Also some technical considerations in arranging the multiple wires are briefly discussed.

  • PDF

진동현 센서 제작 공정 자동화를 위한 자동 장력 조절 및 접합 장치의 개발 (Development of Automatic Tension Control and Fixing Device for An Automatic Manufacturing Process of A Vibrating Wire Sensor)

  • 고석조;박장식;유기호;김성원;이승훈
    • 한국산업융합학회 논문집
    • /
    • 제17권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Constructing structures is the basic process requiring establishment of grounds. However, cracks due to sinking and distorting ground influence directly on the safety of structural health. Vibrating wire sensor measures the crack of structure by detecting the differences of wire tensions in analogue manner. In the previous production process, the tension is adjusted manually measuring the frequency of vibrating wire. Therefore, the accuracy of a sensor was depends on the skill level of labor. In this study, the automatic tension control and fixing devise is developed to enhance both accuracy and productivity. To evaluate the performance of the vibrating wire sensor, the nonlinearity of sensor is measured. The automatic tension control and fixing devise enhances the nonlinearity of the sensor from 0.398 to 0.056%. Therefore, the accuracy of the newly proposed method is successful.

Initial Study of a Wire Mesh Tomography Sensor for Liquid/Gas Component Investigation

  • Rahiman, M.H.F.;Siow, L.T.;Rahim, R.A.;Zakaria, Z.;Ang, Vernoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2205-2210
    • /
    • 2015
  • Experimental studies have been carried out to study the principle operation of the conductive type wire-mesh tomography sensor and analyse the wire-mesh tomography sensor for the liquid/gas two-phase flow interface and void fraction distribution in a process column. The measurement of the two-phase flows in the process column is based on the cross-sectional local instantaneous conductivity. The sensor consists of two planes of parallel electrode wires with 16 electrodes each and was placed orthogonally with each plane. The sensor electrode wires were made of tinned copper wire with an outer diameter of 0.91 mm which stretched over the sensor fixture. Therefore, this result in the mesh grid size with 5.53×5.53mm2. The wire-mesh sensor was tested in a horizontal liquid/gas two-phase flows process column with nominal diameter of 95.6 mm and the sampling frequency of 5882.3529 Hz. The tomogram results show that the wire-mesh tomography provides significant results to represent the void fraction distribution in the process column and estimation error was found in the liquid/gas interface level

Development of smart transducer with embedded sensor for automatic process control of ultrasonic wire bonding

  • Or, Siu Wing;Chan, Helen Lai Wa;Liu, Peter Chou Kee
    • Smart Structures and Systems
    • /
    • 제1권1호
    • /
    • pp.47-61
    • /
    • 2005
  • A ring-shaped lead zirconate titanate (PZT) piezoceramic sensor has been integrated with the Langevin-type piezoceramic driver of an ultrasonic wire-bonding transducer to form a smart transducer for in-situ measurement of three essential bonding parameters: namely, impact force, ultrasonic amplitude and bond time. This sensor has an inner diameter, an outer diameter and a thickness of 12.7 mm, 5.1 mm and 0.6 mm, respectively. It has a specifically designed electrode pattern on the two major surfaces perpendicular to its thickness along which polarization is induced. The process-test results have indicated that the sensor not only is sensitive to excessive impact forces exerted on the devices to be bonded but also can track changes in the ultrasonic amplitude proficiently during bonding. Good correlation between the sensor outputs and the bond quality has been established. This smart transducer has good potential to be used in automatic process-control systems for ultrasonic wire bonding.

철조망 감시를 위한 무선 센서 네트워크에서 이산 웨이블릿 변환과 동적 시간 정합 알고리즘을 이용한 특징 추출 (Feature Extraction using Discrete Wavelet Transform and Dynamic Time-Warped Algorithms in Wireless Sensor Networks for Barbed Wire Entanglements Surveillance)

  • 이태영;차대현;홍진근;한군희;황찬식
    • 한국산학기술학회논문지
    • /
    • 제11권4호
    • /
    • pp.1342-1347
    • /
    • 2010
  • 무선 센서 네트워크의 다양한 연구 분야 중에서 철조망에서의 표적의 침입 탐지 및 식별에 관한 연구는 산업시설, 보안지역, 교도소, 군사지역, 공항 등 다양한 분야에서 사용된다. 현재 철조망 감시는 대부분 유선 센서 노드를 통한 유선 센서 네트워크 환경에서 이루어지고 있다. 기존의 유선 센서 네트워크는 100bps 이상의 높은 데이터 전송률을 통해 수신되는 높은 샘플링 신호를 이용하여 고속 푸리에 변환에 의한 신호의 주파수 분석 기법을 사용해 왔다. 하지만, 유선 센서 네트워크의 높은 데이터 전송률과 비교하여 무선 센서 네트워크의 센서 노드는 유선 센서 네트워크에 비해 매우 낮은 데이터 전송률을 가진다. 따라서 무선 센서 네트워크에서 수신되는 신호의 샘플링이 매우 낮고, 유선 센서 네트워크에서 사용된 고속 푸리에 변환에 의한 신호의 주파수 분석에 따른 주파수별 특징 추출을 할 수 없다. 따라서 본 논문에서는 철조망 감시를 위한 높은 데이터 전송률을 보장하는 유선 센서 네트워크에 비해 제한된 통신자원과 센서 노드의 낮은 데이터 전송률로 인해 수신되는 한정적인 신호의 정보를 이용한 무선 센서 네트워크에서 철조망의 표적 침입 탐지 및 식별을 위한 특징 추출 알고리즘을 제안한다.

Impaction of a continuous glucose monitoring sensor

  • Park, Kyong Chan;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.392-394
    • /
    • 2021
  • A 33-year-old man presented to the plastic surgery department for foreign body removal 1 month after the insertion of a continuous glucose monitoring (CGM) sensor (Dexcom G5) in the left upper arm. The patient had used the CGM system for 5 years, and the insertion was done in the usual manner. The entire sensor wire was visible on simple radiography and ultrasonography. In the operating room, and the sensor wire was identified in the intermuscular septum and removed. No foreign body reaction or inflammatory signs were found around the CGM, and the extracted wire measured 2.5 cm. Thus, it was assumed that the whole sensor wire was detached from the transmitter, not fractured. No remnant foreign body was observed on follow-up simple radiography.

Zinc Oxide Wire-Like Thin Films as Nitrogen Monoxide Gas Sensor

  • Hung, Nguyen Le;Kim, Hyojin;Kim, Dojin
    • 한국재료학회지
    • /
    • 제25권7호
    • /
    • pp.358-363
    • /
    • 2015
  • We present an excellent detection for nitrogen monoxide (NO) gas using polycrystalline ZnO wire-like films synthesized via a simple method combined with sputtering of Zn metallic films and subsequent thermal oxidation of the sputtered Zn nanowire films in dry air. Structural and morphological characterization revealed that it would be possible to synthesize polycrystalline hexagonal wurtzite ZnO films of a wire-like nanostructure with widths of 100-150 nm and lengths of several microns by controlling the sputtering conditions. It was found from the gas sensing measurements that the ZnO wire-like thin film gas sensor showed a significantly high response, with a maximum value of 29.2 for 2 ppm NO at $200^{\circ}C$, as well as a reversible fast response to NO with a very low detection limit of 50 ppb. In addition, the ZnO wire-like thin film gas sensor also displayed an NO-selective sensing response for NO, $O_2$, $H_2$, $NH_3$, and CO gases. Our results illustrate that polycrystalline ZnO wire-like thin films are potential sensing materials for the fabrication of NO-sensitive high-performance gas sensors.

Draw-Wire센서를 이용한 파이프 플랜지 계측시스템 (Pipe Flange Measurement System Using Draw-Wire Sensor)

  • 윤재웅;윤강섭;이수철
    • 한국정밀공학회지
    • /
    • 제20권8호
    • /
    • pp.62-69
    • /
    • 2003
  • In most shipyards, the measurement of 3-dimensional relative position of pipes should be connected in the block depends on the manual operation. It results a very tedious and inefficient procedure, thus the proper measurement system is needed to improve productivity and accuracy. This paper describes the development of pipe measurement system including system concepts, measuring procedures, system calibration, and its accuracy and productivity. And also, the possibility and things to be improved for application in shipyard are discussed in this paper.