• Title/Summary/Keyword: Sensor Precision

Search Result 1,643, Processing Time 0.036 seconds

IEEE 1451 based Smart Module for In-vehicle Networking Systems in Intelligent Vehicles (지능형 차량에서 IVN 시스템을 위한 IEEE 1451 기반 스마트 모듈의 개발)

  • Kim, Man-Ho;Ryu, Se-Hyung;Lee, Kyung-Chang;Lee, Seok
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.168-171
    • /
    • 2003
  • As vehicles are more intelligent for convenience and safety of drivers, the in-vehicle networking systems and smart modules are essential components for intelligent vehicles. However, for the smart module to widely apply to the IVN systems, two problems are considered as follows. Firstly, because it is very difficult that transducer manufacturers developed the smart module that supports the existing all IVN protocols, the smart module must be independent to the type of networking protocols. Secondly, when the smart module is exchanged due to its failure, it is necessary how the transducer is only exchanged without exchange of the microprocessor and network transceiver. This paper deals with the IEEE 1451 based smart module that describes the digital interface between a network transceiver and sensor module. Finally. efficiency of the IEEE 1451 based smart module was evaluated on the experimental model.

  • PDF

Design of Irrigation Pumping System Controller for Operational Instrument of Articulation (관절경 수술을 위한 관주(灌注)시스 (Irrigation Pumping System) 제어기의 개발)

  • 김민수;이순걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1294-1297
    • /
    • 2003
  • With the development of medical field, many kinds of operations have been performed on human articulation. Arthroscopic surgery, which has Irrigation Pumping System for security of operator vision and washing spaces of operation, has been used for more merits than others. In this paper, it is presented that the research on a reliable control algorithm of the pumping system instrument for arthroscopic surgery. Before clinical operation, the flexible artificial articulation model is used for realizing the model the most same as human's and the algorithm has been exploited for it. This system is considered of the following; limited sensing point, dynamic effect by compliance, time delay by fluid flow and so on. The system is composed with a pressure controller, a regulator for keeping air pressure, an airtight tank that can have distilled water packs, artificial articulation and a measuring system, and has controlled by the feedback of pressure sensor on the artificial articulation. Also the system has applied to Smith Predictor for time delay and the parameter estimation method for the most suitable system with both the experiment data and modeling. In this paper, the pressure error that is between an air pressure tank and an artificial articulation was measured so that the system could be presumed and then the controller had developed for performing State-Feedback. Finally, the controller with a real microprocessor has realized. The confidence of system can be proved by applying this control algorithm to an artificial articulation experiment material.

  • PDF

Development of the Training System for Equilibrium Sense Using the Unstable Platform (불안정판을 이용한 평형감각 훈련시스템 개발)

  • Piao, Yong-Jun;Yu, Mi;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.192-198
    • /
    • 2005
  • In this paper, we propose a new training system for the improvement of equilibrium sense using unstable platform. The equilibrium sense, which provides orientation with respect to gravity, is important to integrate the vision, somatosensory and vestibular function to maintain the equilibrium sense of the human body. In order to improve the equilibrium sense, we developed the software program such as a block game, pingpong game using Visual C++. These training system for the equilibrium sense consists of unstable platform, computer interface and software program. The unstable platform was a simple structure of elliptical-type which included tilt sensor, wireless RF module and the device of power supply. To evaluate the effect of balance training, we measured and evaluated the parameters as the moving time to the target, duration to maintain cursor in the target of screen and the error between sine curve and acquired data. As a results, the moving time to the target and duration to maintain cursor in the target was improved through the repeating training of equilibrium sense. It was concluded that this system was reliable in the evaluation of equilibrium sense. This system might be applied to clinical use as an effective balance training system.

Development and Evaluation of a New Gait Phase Detection System using FSR Sensors and a Gyrosensor (저항센서와자이로센서를이용한새로운보행주기검출시스템의개발및평가)

  • Ahn Seung Chan;Hwang Sung Jae;Kang Sung Jae;Kim Young Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.196-203
    • /
    • 2004
  • In this study, a new gait phase detection system using both FSR(Force Sensing Resister) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the posterior aspect of a shoe. An algorithm was also developed to determine eight different gait transitions among four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was compared with the conventional gait phase detection system using only FSR sensors in various gait experiments such as level walking, fore-foot walking and stair walking. In fore-foot walking and stair walking, the developed system showed much better accuracy and reliability to detect gait phases. The developed gait phase detection system using both FSR sensors and a gyrosensor will be helpful not only to determine pathological gait phases but to apply prosthetics, orthotics and functional electrical stimulation to patients with gait disorders.

A study on the Development of the Portable Device for Safety Diagnosis and Dynamic Characteristics Analysis of Elevator using Fuzzy Algorithm (Fuzzy 알고리즘을 이용한 엘리베이터 안전진단 및 동특성 분석 포터블 장비 개발)

  • 김태형;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.199-202
    • /
    • 2001
  • An elevator system, which is essential equipment for vertical movement of an object, as a property of building, has been driven by various expenditures and purposes. Since developing electrical control technology, control system are highly developed. The elevator system has expanded widely, but a data accuracy acquisition technique and safety predict technique for securing system safety is still at a basic level. So, objective verification for elevator confidence condition requires an absolute accuracy measurement technique. Therefore, this study is executed in order to acquire a method of depending on sense of a manager with simple numeric measurement data, and to construct a logical, analytical foresight system for more efficient elevator management system. As an artificial intelligence for diagnosis, the fuzzy inference algorithm is used for foreseeing the system in this thesis, because the fuzzy algorithm is the most useful method for resolving subjective ideas and a vague judgment of humans. The fuzzy inference algorithm is developed for each sensor signal(i.e. vibration, velocity, current).

  • PDF

The Development of Micro NCT for Micro Blanking/Punching of Thin Plates (미세박판가공을 위한 마이크로 NCT 제작에 관한 연구)

  • 홍남표;신용승;최근형;김병희;장인배;김헌영;오수익
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.1084-1087
    • /
    • 1997
  • In this paper, we developed the micro NCT system for punching the thin plates, which is driven is driven by the standalone type microprocessor. In order to adjust the alignment between the punch and die in-situ punching procedures, the non-contact type laser sensor for measuring the burr and micro-driving system for punching die with using the differential screw are developed. The height of burr in four directions in the punched hole of test specimen are measured, and the measured data are transferred to the personal computer by RS232C serial communication technology. In the personal computer, by using the graphic user interface type monitoring program and data handling procedures which includes the filtering algorithms, the direction and length of movement of the die position is decided and these data are transferred back to the microprocessor. The microprocessor drives the micro positioning stage based on these data. Even if this method is not a perfect solution for the in-situ alignment in micro punching, but this alignment methodology is accomplished in the same stage just after the punching that we hope to solve the alignment problem in the punching system based on this technology.

  • PDF

Development of Force Reflecting Joystick for Feild Robot (필드로봇을 위한 힘방향 조이스틱 개발)

  • 송인성;안경관;양순용;이병룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.357-360
    • /
    • 1997
  • Abstract: In teleoperation field robotic system such as hydraulically actuated robotic excavator, the maneuverability and convenience is the most important part in the operation of robotic excavator. Particularly the force information is important in dealing with digging and leveling operation in the teleoperated excavator. Excavators are also subject to a wide variation of soil-tool interaction forces. This paper presents a new force reflecting joystick in a velocity-force type bilateral teleoperation system. The master system is electrical joystick and the slave system IS hydraulically actuated cylinder with linear position sensor. Particularly Pneumatic motor is used newly in the master joystick for force reflection and the information of the pressure of salve cylinder is measured and utilized as the force feedback signal. Also force-reflection gain greatly affects the excavation performance of a hydraulically actuated robotic system and it is very difficult to determine it appropriately since slave excavator contacts with various environments such as from soft soil to rock. To overcome this, this paper proposes a force-reflection gain selecting algorithm based on artificial neural network and fuzzy logic.

  • PDF

Cellular Force Measurement for Force Feedback-Based Biomanipulation (힘반향 기반의 바이오매니퓰레이션을 위한 세포 조작력 측정)

  • Kim, Duk-Ho;Kim, Byung-Kyu;Yoon, Seok;Kang, Hyun-Jae
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.237-240
    • /
    • 2003
  • In biological cell manipulation, manual thrust or penetration of an injection pipette into an embryo cell is currently performed by a skilled operator, relying on visual feedback information only. Accurately measuring cellular forces is a requirement for minimally invasive cell injections. Moreover, the cellular farce sensing is essential in investigating the biophysical properties for cell injury and membrane modeling studies. This paper presents cellular force measurements for the force feedback-based biomanipulation. Cellular force measurement system using piezoelectric polymer sensor is implemented to measure the penetration force of a zebrafish egg cell. First, measurement system setup and calibration are described. Second, the force feedback-based biomanipulation is experimentally carried out. Experimental results show that it successfully supplies real-time cellular force feedback to the operator at several tens of uN and thus plays a main role in improving the reliability of biological cell injection tasks.

  • PDF

Development of Liquid Metal Strain Gauge for Measuring WT Blade's Deformation (풍력발전기 블레이드 변형 측정을 위한 액체금속 스트레인 게이지 개발)

  • Park, In Kyum;Seo, Youngho;Kim, Byeong Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.3
    • /
    • pp.307-314
    • /
    • 2015
  • In this paper, the embedding type novel liquid metal strain gauge was developed for measuring the deformation of wind turbine blades. In general, the conventional methods for the SHM have many disadvantages such as frequency distortion in FBG sensors, the low gauge factor and mechanical failures in strain gauges and extremely sophisticated filtering in AE sensors. However, the liquid metal filled in a pre-confined micro channel shows dramatic characteristics such as high sensitivity, flexibility and robustnes! s to environment. To adopt such a high feasibility of the liquid metal in flexible sensor applications, the EGaIn was introduced to make flexible liquid metal strain gauges for the SHM. A micro channeled flexible film fabricated by the several MEMS processes and the PDMS replication was filled with EGaIn and wire-connected. Lots of experiments were conducted to investigate the performance of the developed strain gauges and verify the feasibility to the actual wind turbine blades health monitoring.

Measurement of the Time Constant of Industrial Platinum Resistance Thermometers (산업용 백금저항온도계의 시정수 측정)

  • Kim, Yong-Gyoo;Kim, Sook-Hyang;Yang, In-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.41-46
    • /
    • 2009
  • We present experimental data on the time response behavior of industrial platinum resistance thermometers (IPRT) to help with the selection of proper sensors in industry and research laboratories. Time constants of IPRTs were measured using a method specified in ASTM standards. Two different sensors of different protecting sheath diameters were tested in air, water and silicon oil at temperatures from $0^{\circ}C$ to $200^{\circ}C$. The time constant was the smallest in water and the highest in air. As the test temperature increased, time constants tended to decrease at all heat conducting media. For different diameters of sheath of IPRT at the same temperature, it was found that the IPRT of larger diameter showed higher time constant in air, but the opposite dependence was observed in water and oil. From the measured results, it was suggested that the sensor diameter and heat conducting medium should be considered if one wants to select proper thermometer to measure the dynamic temperature change in industry and research area.