• Title/Summary/Keyword: Sensitivity study

Search Result 9,097, Processing Time 0.044 seconds

Comparison of the Diagnostic Performance of $^{14}C$-urea Breath Test According to Counting Method for the Diagnosis of Helicobacter pylori Infection (Helicobacter pylori 감염 진단 시 $^{14}C$-요소호기검사의 계수측정 방법에 따른 진단성능 비교)

  • Kim, Min-Woo;Lim, Seok-Tae;Lee, Seung-Ok;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • Purpose: $^{14}C$-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylori (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid $^{14}C$-UBT (Heliprobe method), which was equipped with $Geiger-M\ddot{u}ller$ counter and compared the results with those obtained by using the conventional method. Materials and Methods: Forty-nine patients with dyspepsia underwent gastroduodenoscopy and $^{14}C$-UBT. A 37 KBq $^{14}C$-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Hellprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. Results: In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). Thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). Conclusion: The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.

Role of Whole Body FDG-PET in the Diagnosis of Hidden Distant Metastasis before Liver Transplantation in Patients with Primary Liver Cancer (고식적 검사로 간외 전이를 진단하지 못한 원발성 간암 환자에서 간이식 전에 시행한 전신 FDG-PET의 역할)

  • Lee, Won-Woo;Ryu, Jin-Sook;Yang, You-Jung;Kim, Jae-Seung;Yeo, Jeong-Seok;Moon, Dae-Hyuk;Lee, Sung-Gyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.368-380
    • /
    • 2002
  • Purpose: Liver transplantation (LT), one of the therapeutic options of primary liver cancer has been suffering from recurrence caused by metastasis in 8-54% of patients. This study was performed to investigate whether FDG-PET is useful for detecting hidden metastasis in LT candidates. Materials and Methods: Twenty-six patients (male:female=23:3, mean age 55.7 years) underwent FDG-PET. Their previous conventional diagnostic studies (CDS) like abdomen US and CT, chest x-ray and CT, and bone scan were negative (n=22) or equivocal (n=4) for metastasis. Positive FDG-PET findings were confirmed by biopsy or clinical follow-up. Results: Among 4 patients with equivocal metastatic lesions on CDS, 3 had 6 hypermetabolic lesions on FDG-PET, which were confirmed as metastasis and subsequently LTs were cancelled. Of these, 5 lesions were initially negative on CDS. Remained 1 patient underwent LT with a negative FDG-PET result. Among 22 patients without metastasis on CDS, 5 had 7 hypermetabolic lesions on FDG-PET. One of these patients proved to have 2 metastatic lesions, and LT was cancelled. The other 4 patients had S hypermetabolic lesions on FDG-PET, which were confirmed as benign lesions, and 3 patients of them underwent LT. In summary, FDG-PET was useful in avoiding 4 unwarranted LT by detecting unsuspected metastatic lesions on CDS. A total of 17 patients underwent LT. In comparison with pathology, the sensitivity and specificity of FDG-PET for detecting viable primary liver cancer were 55.6% (5/9) and 87.5% (7/8), respectively. Conclusion: FDG-PET can detect additional hidden metastasis and contribute to reducing unwarranted LT in the patients with primary liver cancer.

Effects of Electrical Stimulation on the Biochemical Properties of Plaice, Paralichthys olivaceus, Sarcoplasmic Reticulum and Myofibrils (넙치 근소포체 및 근원섬유의 생화학적 특성에 미치는 전기자극의 영향)

  • KIM Tae-Jin;CHOI Young-Jun;KIM Dong-Su;CHO Young-Je
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.545-552
    • /
    • 1998
  • This study was undertaken to clarify the effects of electrical stimulation on the biochemical properties of plaice sarcoplasmic reticulum and myofibrils at early period of death. The plaices were electrically stimulated (110V/60 Hz) In sea water bath for 15, 35, and 60 seconds, and killed instantly by spiking at the head. Killed samples were investigated for the changes in $Ca^{2+}$-ATPase activity of FSR (fragmented sarcoplasmic reticulum), LSR (light SR), HSR (heavy SR), and SDS-PAGE pattern of FSR. $Ca^{2+}$-ATPase activity of FSR increased until $45^{\circ}C$ and inactivated over $50^{\circ}C$. $Ca^{2+}$-ATPase activity of FSR remarkably decreased according to the duration of electrical stimulation. Myofibrillar $Mg^{2+}$-ATPase activity of electrically stimulated plaices in the presence of $Ca^{2+}$ was higher than that of sample instantly killed by spiking. $Mg^{2+}$-ATPase activity of myofibrils increased by electrical stimulation and the activity decreased during storage at $5^{\circ}C$. Myofibrillar $Mg^{2+}$-ATPase activity in sample killed by spiking was not affected by $Ca^{2+}$ ion. Myofibrillar $Mg^{2+}$-ATPase activity of electrically stimulated sample in the absen-re of $Ca^{2+}$ decreased during storage at $5^{\circ}C$, whit $Mg^{2+}$-ATPase activity in unstimulated sample did not show any change. $Ca^{2+}$-sensitivity of myofibrils showed no differences between electrically stimulated sample and sample killed by spiking, and the was no change during at $5^{\circ}C$.

  • PDF

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Usefulness of Serum Thymidine Kinase 1 as a Biomarker for Aggressive Clinical Behavior in B-cell Lymphoma (B세포림프종의 임상적 악성도 표지자로서 혈청 Thymidine Kinase 1의 유용성)

  • Kim, Heyjin;Kang, Hye Jin;Lee, Jin Kyung;Hong, Young Jun;Hong, Seok-Il;Chang, Yoon Hwan
    • Laboratory Medicine Online
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • Background: The cell cycle-dependent enzyme thymidine kinase 1 (TK1) is known to increase during cancer cell proliferation and has been reported as a prognostic marker for various hematologic malignancies and solid tumors. This study aimed to determine the reference interval in Korean healthy controls and to evaluate the usefulness of TK1 as a biomarker for aggressive clinical behavior in B-cell lymphoma patients. Methods: We enrolled 72 previously untreated patients with B-cell lymphoma and 143 healthy controls. Serum TK1 levels were measured by chemiluminescence immunoassay ($Liaison^{(R)}$, DiaSorin, USA). We established the reference intervals in healthy controls. The diagnostic performance of serum TK1 was studied using receiver operating characteristic (ROC) analysis, and the correlation between the cutoff level for serum TK1 and clinical characteristics of B-cell lymphoma was evaluated. Results: The reference range (95th percentile) of serum TK1 in healthy controls was 5.4-21.8 U/L. There was a clear difference in TK1 levels between patients with B-cell lymphoma and healthy controls ($40.6{\pm}68.5$ vs. $11.8{\pm}4.4U/L$, P <0.001). The area under the curve of serum TK1 for the diagnosis of B-cell lymphoma was 0.73 (cutoff, 15.2 U/L; sensitivity, 59.7%; specificity, 83.2%). An increased TK1 level (${\geq}15.2U/L$) correlated with the advanced clinical stage (P <0.001), bone marrow involvement (P =0.013), international prognostic index score (P =0.001), lactate dehydrogenase level (P =0.001), low Hb level (<12 g/dL) (P =0.028), and lymphocyte count (P =0.023). Conclusions: The serum TK1 level could serve as a useful biomarker for aggressive clinical behavior in B-cell lymphoma patients.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

Efficiency Comparison of Environmental DNA Metabarcoding of Freshwater Fishes according to Filters, Extraction Kits, Primer Sets and PCR Methods (분석조건별 담수어류의 환경 DNA 메타바코딩 효율 비교: 필터, 추출 키트, 프라이머 조합 및 PCR 방법)

  • Kim, Keun-Sik;Kim, Keun-Yong;Yoon, Ju-Duk
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.3
    • /
    • pp.199-208
    • /
    • 2021
  • Environmental DNA (eDNA) metabarcoding is effective method with high detection sensitivity for evaluating fish biodiversity and detecting endangered fish from natural water samples. We compared the richness of operational taxonomic units(OTUs) and composition of freshwater fishes according to filters(cellulose nitrate filter vs. glass fiber filter), extraction kits(DNeasy2® Blood & Tissue Kit vs. DNeasy2® PowerWater Kit), primer sets (12S rDNA vs. 16S rDNA), and PCR methods (conventional PCR vs. touchdown PCR) to determine the optimal conditions for metabarcoding analysis of Korean freshwater fish. The glass fiber filter and DNeasy2® Blood & Tissue Kit combination showed the highest number of freshwater fish OTUs in both 12S and 16S rDNA. Among the four types, the primer sets only showed statistically significant difference in the average number of OTUs in class Actinopterygii (non-parametric Wilcoxon signed ranks test, p=0.005). However, there was no difference in the average number of OTUs in freshwater fish. The species composition also showed significant difference according to primer sets (PERMANOVA, Pseudo-F=6.9489, p=0.006), but no differences were observed in the other three types. The non-metric multidimensional scaling (NMDS) results revealed that species composition clustered together according to primer sets based on similarity of 65%; 16S rDNA primer set was mainly attributed to endangered species such as Microphysogobio koreensis and Pseudogobio brevicorpus. In contrast, the 12S rDNA primer set was mainly attributed to common species such as Zacco platypus and Coreoperca herzi. This study provides essential information on species diversity analysis using metabarcoding for environmental water samples obtained from rivers in Korea.

A Study on the Protection of Personal Information in the Medical Service Act (의료법의 개인정보보호에 관한 연구)

  • Sung, Soo-Yeon
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.75-103
    • /
    • 2020
  • There is a growing voice that medical information should be shared because it can prepare for genetic diseases or cancer by analyzing and utilizing medical information in big data or artificial intelligence to develop medical technology and improve patient care. The utilization and protection of patients' personal information are the same as two sides of the same coin. Medical institutions or medical personnel should take extra caution in handling personal information with high environmental distinct characteristics and sensitivity, which is different from general information processors. In general, the patient's personal information is processed by medical personnel or medical institutions through the processes of collection, creation, and destruction. Still, the use of terms related to personal information in the Medical Service Act is jumbled, or the scope of application is unclear, so it relies on the interpretation of precedents. For the medical personnel or the founder of the medical institution, in the case of infringement of Article 24(4), it cannot be regarded that it means only medical treatment information among personal information, whether or not it should be treated the same as the personal information under Article 23, because the sensitive information of patients is recorded, saved, and stored in electronic medical records. Although the prohibition of information leakage under Article 19 of the Medical Service Act has a revision; 'secret' that was learned in business was revised to 'information', but only the name was changed, and the benefit and protection of the law is the same as the 'secret' of the criminal law, such that the patient's right to self-determination of personal information is not protected. The Privacy Law and the Local Health Act consider the benefit and protection of the law in 'information learned in business' as the right to self-determination of personal information and stipulate the same penalties for personal information infringement such as leakage, forgery, alteration, and damage. The privacy regulations of the Medical Service Act require that the terms be adjusted uniformly because the jumbled use of terms can confuse information subjects, information processors, and shows certain limitations on the protection of personal information because the contents or scope of the regulations of the Medical Service Law for special corporations and the Privacy Law may cause confusion in interpretation. The patient's personal information is sensitive and must be safely protected in its use and processing. Personal information must be processed in accordance with the protection principle of Privacy Law, and the rights such as privacy, freedom, personal rights, and the right to self-determination of personal information of patients or guardians, the information subject, must be guaranteed.

Evaluation of a Rapid Diagnostic Antigen Test Kit Ribotest Mycoplasma® for the Detection of Mycoplasma pneumoniae (Mycoplasma pneumoniae 감염의 신속 항원 검사 키트 "Ribotest Mycoplasma®"의 진단적 평가)

  • Yang, Song I;Han, Mi Seon;Kim, Sun Jung;Lee, Seong Yeon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.2
    • /
    • pp.81-88
    • /
    • 2019
  • Purpose: Early detection of Mycoplasma pneumoniae is important for appropriate antimicrobial therapy in children with pneumonia. This study aimed to evaluate the diagnostic value of a rapid antigen test kit in detecting M. pneumoniae from respiratory specimens in children with lower respiratory tract infection (LRTI). Methods: A total of 215 nasopharyngeal aspirates (NPAs) were selected from a pool of NPAs that had been obtained from children admitted for LRTI from August 2010 to August 2018. The specimens had been tested for M. pneumoniae by culture and stored at $-70^{\circ}C$ until use. Tests with Ribotest $Mycoplasma^{(R)}$ were performed and interpreted independently by two investigators who were blinded to the culture results. Results: Among the 215 NPAs, 119 were culture positive for M. pneumoniae and 96 were culture negative. Of the culture-positive specimens, 74 (62.2%) were positive for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$, and 92 of the 96 (95.8%) culture-negative specimens were negative for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$. When culture was used as the standard test, the sensitivity and specificity of Ribotest $Mycoplasma^{(R)}$ were 62.2% and 95.8%, respectively. Additionally, the positive predictive value, negative predictive value, and overall agreement rates with Ribotest $Mycoplasma^{(R)}$ were 94.9%, 67.2%, and 77.2%, respectively. Conclusions: A positive test result of Ribotest $Mycoplasma^{(R)}$ suggests a high likelihood of culture-positive M. pneumoniae infection. However, a negative test result should be interpreted with caution because nearly one-third of negative test results reveal culture-positive M. pneumoniae infections.

Determination and Validation of an Analytical Method for Dichlobentiazox in Agricultural Products with LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Dichlobentiazox 시험법 개발 및 검증)

  • Gu, Sun Young;Lee, Han Sol;Park, Ji-Su;Lee, Su Jung;Shin, Hye-Sun;Kang, Sung Eun;Chung, Yun Mi;Choi, Ha Na;Yoon, Sang Soon;Jung, Young-Hyun;Yoon, Hae Jung
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.2
    • /
    • pp.108-117
    • /
    • 2021
  • BACKGROUND: Dichlobentiazox is a newly registered pesticide in Korea as a triazole fungicide and requires establishment of an official analysis method for the safety management. Therefore, the aim of this study was to determine the residual analysis method of dichlobentiazox for the five representative agricultural products. METHODS AND RESULTS: Three QuEChERS methods were applied to establish the extraction method, and the EN method was finally selected through the recovery test. In addition, various adsorbent agents were applied to establish the clean-up method. As a result, it was found that the recovery of the tested pesticide was reduced when using the d-SPE method with PSA and GCB, but C18 showed an excellent recovery. Therefore this method was established as the final analysis method. For the analysis, LC-MS/MS was used with consideration of the selectivity and sensitivity of the target pesticide and was operated in MRM mode. The results of the recovery test using the established analysis method and inter laboratory validation showed a valid range of 70-120%, with standard deviation and coefficient of variation of less than 3.0% and 11.6%, respectively. CONCLUSION: Dichlobentiazox could be analyzed with a modified QuEChERS method, and the method determined would be widely available to ensure the safety of residual pesticides in Korea.