• 제목/요약/키워드: Sensitivity of Low Temperature

검색결과 351건 처리시간 0.027초

급냉응고된 과공정 Al-Si합금의 고온변형특성에 관한 연구 (High Temperature Deformation Behavior of Rapid-Solidification Processed Al-18Si Alloy)

  • 김성일
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2000년도 춘계학술대회논문집
    • /
    • pp.183-186
    • /
    • 2000
  • The high temperature deformation behavior of spray-formed Al-19wt%Si-1.87wt%Mg-0.085wt.%Fe alloy was studied by torsion testing in the strain rate range of 0.001-1 sec-1 and in the temperature range of 300-500 $^{\circ}C$. The relationship between stress temperature and strain rate is expressed using the Power law. the behavior of dynamic recrystallization is showed in 300-35$0^{\circ}C$, 1-0.1sec-1 and the behavior of dynamic recovery is showed in 450-50$0^{\circ}C$, 0.01-0.001sec-1 The size of Si particles is mall when the temperature is low and the strain rate is high. The strain rate sensitivity(m) and the apparent activation energy(Q) indicate the dependence on strain rate and temperature for flow stress respectively. The hot ductility is high when m is high and Q is low. The maps of strain rate sensitivity and apparent activation energy suggest the optimum processing conditions.

  • PDF

Low temperature-operating NiO-CoO butane gas sensors

  • 정동호;최순돈;민봉기
    • 센서학회지
    • /
    • 제17권4호
    • /
    • pp.303-307
    • /
    • 2008
  • $NiO,\;Cu_2O,\;Mn_2O_3$ and $Cr_2O_3$ as p-type semiconductors were added in CoO with 15 wt.% ethylene glycol binder and measured the butane gas sensing characteristics. The highest sensitivity is obtained for the NiO-CoO sensors. CoO-20 at.% NiO sensor with 15 wt.% ethylene glycol binder sintered at $1100^{\circ}C$ for 24 h exhibits high sensitivity of 90 % to 5000 ppm butane gas at the sensor temperature of $250^{\circ}C$, compared to low sensitivities at the low operating temperature for commercial sensors. Response and recovery times are, respectively, within few seconds and 1min in the static flow system, indicating rapid adsorption and desorption of butane gas on sensor surface even at this low temperature.

차체용 강판의 온도에 따른 변형률 속도 민감도 연구 (A study on the strain rate sensitivity according to the temperature for steel sheets of an auto-body)

  • 이희종;송정한;조상순;김석봉;허훈;박성호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.148-151
    • /
    • 2005
  • This paper is concerned with the thermo-mechanical behavior and temperature dependent strain rate sensitivity of steel sheet for an auto-body. In order to Identify the temperature dependent strain rate sensitivity of SPRC35R and SPRC45E, uniaxial tension tests are performed with the variation of the strain rates from 0.001/sec to 200/sec, and the variation of environmental temperatures from $-40^{\circ}C\;to\;200^{\circ}C$. The thermo-mechanical response at the quasi-static state is obtained with the static tensile test and at the intermediate strain rate is from the high speed tensile test. The experimental results show that the strain rate sensitivity increases at low temperature and it decreases at high temperature. It means that as the strain rate getting increasing, the variation of flow stress is more sensitive on the temperature. The results also indicates that the material properties of SPRC35R is more depend on the changes of strain rates and temperature than those of SPRC45E.

  • PDF

금속박막형 압력센서의 제작 (Fabrication of Metal Thin-Film Type Pressure Sensors)

  • 최성규;김병태;남효덕;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.587-590
    • /
    • 2000
  • This paper presents the characteristics of metal thin-film pressure sensors. The micro pressure sensors consists of a chrom thin-film, patterned on a Wheatstone bridge configuration, sputter-deposited onto thermally oxidized Si wafer an aluminium interconnection layer. The fabricated micro pressure sensors shows a low temperature coefficient of resistance, high-sensitivity, low non-linearity and excellent temperature stability. The sensitivity is 1.16~1.21 mV/V.kgf/$\textrm{cm}^2$ in the temperature range of 25~l0$0^{\circ}C$ and the maximum non-linearity is 0.21 %FS.

  • PDF

차체용 강판의 온도에 따른 변형률속도 민감도 연구 (A Study on the Strain-Rate Sensitivity According to the Temperature for Steel Sheets of an Auto-Body)

  • 이희종;송정한;조상순;박성호;허훈
    • 소성∙가공
    • /
    • 제15권2호
    • /
    • pp.132-137
    • /
    • 2006
  • This paper is concerned with the thermo-mechanical behavior including temperature dependent strain-rate sensitivity of steel sheet for an auto-body. In order to identify the temperature dependent strain-rate sensitivity of SPRC35R and SPRC45E, uniaxial tension tests are performed with the variation of the strain-rates from 0.001 /sec to 200 /sec at environmental temperatures varied from $-40^{\circ}C\;to\;200^{\circ}C$. The thermo-mechanical response at the quasi-static state is obtained with the static tensile test and at the intermediate strain-rate is from the high speed tensile test. Experimental results show that the strain-rate sensitivity increases at low temperature. It represents that as the strain-rate increases, the variation of flow stress becomes sensitive on the temperature. The results indicate that the flow stress of SPRC35R is more dependent on the changes of strain-rate and temperature than those of SPRC45E.

Differential Recovery of Photosystem II Complex from Low-Temperature Photoinhibition in Plants with Different Chilling Sensitivity

  • Moon, Byoung-Yong;Norio Murata
    • Journal of Photoscience
    • /
    • 제7권2호
    • /
    • pp.39-44
    • /
    • 2000
  • To examine the chilling tolerance lipids, we compared the chilling susceptibility of photosystem II of wild type tobacco plants with that of transgenic tobacco plants, in which the sensitivity to chilling had been enhanced by genetic modification of fatty acid unsaturation of chloroplast membrane lipids. The transgenic tobacco plants were found to contain reduced levels of unsaturated membrane fatty acids by being tansformed with cDNA for glycerol-3-phosphate acyltransferase from squash. For the purpose of studying on the functional integrity of photosystem II during low-temperature photoinhibition, the photochemical efficiency was measured as the ration of the maximun fluorescence of chlorophyll (Fv/Fm) of photosystem II. In parallel with an investigation on the transgenic plants, susceptibility of chilling-resistant species, such as spinah and pea, and of chilling-sensitive ones, such as squash and sweet potato, to low-temperature photoinhibition was also compared in terms of room temperature-induced chlorophyll fluorescence from photosystem II. When leaf disks from the two genotypes of tobacco plants were exposed to light at 5$^{\circ}C$, the transgenic plants showed more rapid decline in photochemical activity of photosysytme II than wild-type plants. When they were pretreated with lincomycin, an inhibitor of chloroplast-encoded protein synthesis, the extent of photoinhibition was even more accelerated. More impottantly, they showed a comparable extent of photoinhibition in the presence of lincomycin, making a clear contrast to the discrepancy observed in the discrepancy observed in the absence of lincomycin. Restoration of Fv/Fm during recovery from low-temperature photoinhibition occurred more slowly in the transgenic tobacco plants than the wild-type. These findings are discussed in relation to fatty acid unsaturation of membrane phosphatidylglycerol. It appears that the ability of plants to rapidly regenerate the active photosystem II complex from might explain, in part, why chilling-resistant plants can toleratlow-temperature photoinhibition.

  • PDF

Humidity and Temperature Response Characteristics of Optical Fiber Dislocation Fusion Sensor Coated with Graphene Quantum Dots

  • Dailin Li;Xiaodan Yu;Ning Wang;Wenting Liu;Shiqi Liu;Liang Xu;Dong Fang;Huapeng Yu
    • Current Optics and Photonics
    • /
    • 제7권5호
    • /
    • pp.504-510
    • /
    • 2023
  • An optical fiber dislocation fusion humidity sensor coated with graphene quantum dots is investigated. A Mach-Zehnder interferometer is fabricated with three dislocated single-mode fibers with graphene quantum dots coating humidity-sensitive materials. Humidity response experiments showed a good linear response and high sensitivity with easy fabrication and low-cost materials. From 22% to 98% RH, the humidity response sensitivity of the sensor is 0.24 dB/% RH, with 0.9825 linearity. To investigate the cross-response of humidity and temperature, temperature response experiments are conducted. From 30 ℃ to 70 ℃, the results showed 0.02 dB/℃ sensitivity and 0.9824 linearity. The humidity response experimental curve is compared with the temperature experimental curve. The big difference between humidity sensitivity and temperature sensitivity is very helpful to solve the cross-response of humidity and temperature. The influence of temperature fluctuations in humidity measurements is not obvious.

Bi2Mg2/3Nb4/3O7을 사용한 온도센서의 저주파 잡음 특성 (Analysis of Low Frequency Noise Variation in Temperature Sensor With Bi2Mg2/3Nb4/3O7)

  • 조일환;서동선
    • 전기전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.486-490
    • /
    • 2015
  • 기존의 MOS 구조를 갖는 온도 센서가 가지는 누설 전류 문제를 해결하기 위하여 제안된 $Bi_2Mg_{2/3}Nb_{4/3}O_7$ (BMNO) 를 이용한 온도센서의 민감도 평가를 저주파 누설 전류 측정을 통하여 수행하였다. 측정결과에서 서로 다른 어닐링 온도 ( $600^{\circ}C$, $700^{\circ}C$, $800^{\circ}C$) 에 따른 서로 다른 패턴의 저주파 노이즈 특성을 얻을 수 있었으며, 그 결과에서 온도 센서 동작을 저해할 수 있는 공정 조건($700^{\circ}C$) 을 선별하는 결과를 얻을 수 있었다. 이와 같은 측정법은 향후 BMNO를 이용한 온도센서의 공정 최적화를 측정하는 방법으로 응용 될 수 있다.

Low Temperature (LT) GaAs 에피층의 성장과 그 특성연구 (The Growth and Its Characteristics of Low Temperature (LT. $250^{\circ}C$) GaAS Epilayer)

  • 김태근;박정호;조훈영;민석기
    • 전자공학회논문지A
    • /
    • 제31A권9호
    • /
    • pp.96-103
    • /
    • 1994
  • The GaAs epilayer was grown at low temperature (LT. 250.deg. C) by molecular beam epitaxy. The properties of the LTT GaAs, before and after Rapid Thermal Annealing(RTA), were analyzed by Reflection of High Energy Electron Diffraction (RHEED), Double Crystal X-ray(DCX), Raman spectroscopy, PL and Photo-Induced Current Transient Spectroscopy (PICTS). The LT GaAs before RTA, was analyzed by RHEED and DCX, with a result of an improved surface morphology under a relatively As-rich(As/Ga ratio :28) condition, and of an increased lattics parameter of 1.1 1.7% in comparison with a GaAs substrate. However DCX and Raman spectroscopy revealed that the expanded lattics parameter and the crystallinity of LT GaAs could be recovered after RTA. On the other hand, PL spectra indicated that LT GaAs after RTA showed low optical sensitivity unlike High Temperature(HT) GaAs, and that its surface morphology and crystallinity were corresponded with those of HT GaAs. Finally PICTS spectra proved the fact that low sensitivity of LT GaAs was due to the deep level defects (Ec-0.85eV) which were strogly formed by raising RTA temperature to 750.deg. C.

  • PDF

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.