• Title/Summary/Keyword: Sensitivity derivative

Search Result 140, Processing Time 0.02 seconds

Immunoglobin G Antibodies to Purified-Protein-Derivative and Lipoarabinomannan-B by Enzyme-Linked Immunosorbent Assay in the Diagnosis of Tuberculous Pleural Effusion (결핵성 흉막염 환자에 있어서 효소결합 면역분석법으로 측정한 Purified-Protein-Derivative와 Lipoarabinomannan-B에 대한 Immunoglobulin G 항체의 진단적 가치에 관한 연구)

  • Moon, Tai-Hoon;Cho, Chul-Ho;Kwak, Seung-Min;Kim, Jin-Ju;Cho, Sang-Nae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.455-464
    • /
    • 1995
  • Background: Considering that both humoral and cell mediated immunities play an important role for human tuberculosis infection, enzyme-linked immunosorbent assay(ELISA) measurement of immunoglobulin G (IgG) antibody to mycobacterial antigens can be used for the serologic diagnosis of tuberculous pleural effusion. Method: We measured absorbance values of IgG antibodies to purified-protein-derivative (PPD) and lipoarabinomannan-B (LAM-B) in the pleural fluid (PF) and the serum in 40 tuberculous (TPE) and 19 nontuberculous pleural effusions (NTPE). Results: 1) The IgG antibodies to PPD and LAM-B were significantly (P<0.0005) higher in the PF and the serum of TPE compared to NTPE. 2) The IgG antibodies to PPD and LAM-B in the serum were higher than that in PF. 3) Significant correlations were found between pleural and serum IgG antibodies to PPD and LAM-B. 4) With a cutoff value for IgG antibody to PPD in the PF of 0.091, sensitivity was 55.0% and specificity 94.7% in the diagnosis of TPE. 5) With a cutoff value for IgG antibody to LAM-B in the PF of 0.337, sensitivity was 50.0% and specificity 94.7% in the diagnosis of TPE. 6) The seropositive rates in TPE were not related to PPD skin test status, the amount of PF and coexisting active pulmonary tuberculosis. Conclusion: The assay of IgG antibodies to PPD and LAM-B might be useful for the diagnosis of TPE. Our study suggests the mechanism of passive transfer of IgG antibodies to PPD and LAM-B from the serum to the PF through pleural tissue.

  • PDF

Studies on 1,2-Naphthoquinone-(2)diazide-5-sulfonic Acid Ester Derivatives for Pre-sensitized Offset Plates (PS 판용 1,2-Naphthoquinone-(2)diazide-5-sulfonic Acid Ester Derivatives의 합성 및 응용)

  • Ku, Yang Seo;Myung, Young Chan;Ahn, Chong Il;Kim, Sun Ho
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1169-1174
    • /
    • 1999
  • 2-Diazo-1-naphthoquinone-5-sulfonyl chloride(NQD-Cl) was synthesized from sodium 2-diazo-naphthoquinone-5-sulfonate by chlorination. NQD-Cl was esterified with hydroxybenzophenones to give several 1,2-naphthoquinone-(2)-diazide-5-sulfonic acid ester derivatives(NQD-esters). We have compared benzophenone derivatives with methoxy group to benzophenone derivatives with hydroxy group. Solubility of each NQD-ester was studied. Each of NQD-esters was formulated with novolac base resin and PS plates were manufactured. Photosensitivity, bleachability, compatible exposed time and relative sensitivity were determined by UV spectrophotometry, imaged by UV lithographic techniques, and the gray scale method. According to the number of substituted NQD group, it showed that relative sensitivity was different from gray scale method. NQD-esters with methoxy group showed a good solubility and higher sensitivity than commercial PS ones.

  • PDF

Fabrication and pH response characteristics of LAPS(Light addressable potentiometric sensor) with electrolyte/$Si_3N_4/SiO_2$/Si structure (Electrolyte/$Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성)

  • Chang Su-Won;Koh Kwang-Nak;Kang Shin-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.40-44
    • /
    • 1998
  • The LAPS device of fast response and high sensitivity, based on electrochemical potential difference, and its system were fabricated for the precise measurement of pH changes and its characteristic were investigated. The electrostatic variation characteristics of LAPS according to the pH changes and parameters in the device were verified through a simulation using LAPS equivalent circuit model. The LAPS device and its system were fabricated on the basis of the result of simulation. The fabricated LAPS system showed linear sensitivity (about 56 mV/pH within the range of pH 2 to pH 11. In order to overcome the defect of general urea sensor (especially slow response time), urease immobilized nitrocellulose membrane was attached on the LAPS and resulted in the very fast response time, 0.29 mV/sec, 0.86 mV/sec at urea concentration of $50{\mu}g/ml,\; 500{\mu}g/ml$, respectively. And also in order to measure the uranyl ion, the uranyl ion selective sensing membrane with calix[6]arene derivative was used and its sensitivity was 25mV/concentration decade in the wide uranyl ion concentration range of $10^{-11}M\;to\;10^{-4}M$.

Determination of Amitrole in Water Samples by Evaporation and GC/MS (증발법과 GC/MS를 이용한 수질 시료 중의 Amitrole의 분석법 연구)

  • Yoon, So Hee;Hong, Ji Eun;Pyo, Hee Soo;Park, Song Ja
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.483-487
    • /
    • 2003
  • Amitrole is well-known as a non-selective herbicide and it is able to cause contamination of driking water as well as pollution of ground water and surface water. However, it is difficult to extract from water because it has a high solubility for water whereas a low solubility for general organic solvents. This method is described for the determination of amitrole in water samples by GC/MS. After evaporation of 10 mL water sample by a vacuum evaporator, amitrole was derivatized with isobutyl chloroformate (iso-BCF) on room temperature for 15~20 min. As a result, the sensitivity for GCfMS was improved as N-isobutoxycarbonyl amitrole derivative was formed. The linearity of the calibration curve showed good as 0.997. The recoveries were obtained more than 94.9% and relative standard deviations were less than 2.8% at $1.0{\mu}g/L$, $10.0{\mu}g/L$ and $100.0{\mu}g/L$. The limit of detection showed $0.1{\mu}g/L$ with a signal-to-noise ratio (S/N) of 3.

Stress Intensity Factor of Cracked Plates with Bonded Composite Patch by p-Convergence Based Laminated Plate Theory (p-수렴 적층 평판이론에 의한 균열판의 팻취보강후 응력확대계수 산정)

  • Woo, Kwang-Sung;Han, Sang-Hyun;Yang, Seung-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.649-656
    • /
    • 2008
  • The enhancement of the service life of damaged or cracked structures is a major issue for researchers and engineers. The hierarchic void element based on the integrals of Legendre polynomials is used to characterize the fracture behaviour of unpatched crack as well as repaired crack with bonded composite patches by computing the stress intensity factors and stress contours at the crack tip. Since the equivalent single layer approach is adopted in this study, the proposed element is necessary to represent a discontinuous crack part as a continuum body with zero stiffness. Thus the aspect ratio of this element to represent the crack should be extremely slender. The sensitivity of numerical solution with respect to energy release rate, displacement and stress has been tested to show the robustness of zero stiffness element as the aspect ratio is increased up to 2000. The stiffness derivative method and displacement extrapolation method have been applied to calculate the stress intensity factors of Mode I problem. It is noted that the proposed hierarchical void element can be one of alternatives to analyze the patched crack problems.

Development of Enzyme-Linked Immunosorbent Assay for Rapid and Sensitive Analysis of Biotin (Biotin의 분석을 위한 효소면역측정법(ELISA)의 개발)

  • 이경애;손동화;고영태
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.6
    • /
    • pp.1152-1159
    • /
    • 1998
  • In order to develop more rapid and reproducible analysis of biotin known as vitamin H, attempts were made to establish the condition for enzyme linked immunosorbent assay(ELISA) compared with traditional microbiological assay(MBA). Antibiotin and antiserum were obtained from the immunized rabbits injected with emulsion of biotin KLH conjugate and Freund's adjuvant. The antiserum showed cross reactivity on biocytin, a derivative of biotin, which is converted to biotin in intestine, at the rate of 177%(median inhibitory concentration(IC50)=12.58ppb), but not on other derivatives such as desthiobiotin, diaminobiotin and 2 imino biotin. Specific antibody for biotin was purified from the antiserum through protein A column and desalting column. The conditions of competitive direct ELISA (cdELISA) were established. Detection range of biotin concentration by cdELISA was 0.01∼300ng/ ml(ppb). In the spike test with milk, fruit flake and pine carrot juice, the correlation coefficient between two methods of MBA and ELISA was reliably consistent at the value of r=0.992. But detection of biotin by microbiological assay(MBA) was rather restricted in range and nonspecific. Detection range of biotin by MBA was 0.1∼0.5ng/ml(ppb). It showed cross reactivities on biocytin and desthiobiotin at the rate of 80.1% and 66.7%, respectively. In conclusion, ELISA revealed a significant improvement compared with MBA for the biotin detection in terms of sensitivity, detection range and cross reactivity. In addition, a variety of samples could be analyzed rapidly and conveniently at one time by using ELISA. These results strongly suggest that the ELISA is very promising for the practical application to detect biotin contents in a wide range of food stuffs.

  • PDF

luxS and smcR Quorum-Sensing System of Vibrio vulnificus as an Important Factor for In Vivo Survival

  • SHIN NA-RI;BAEK CHANG-HO;LEE DEOG-YONG;CHO YOUNG-WOOK;PARK DAE-KYUN;LEE KO-EUN;KIM KUN-SOO;YOO HAN-SANG
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.1197-1206
    • /
    • 2005
  • Vibrio vulnificus is an opportunistic pathogen that causes a septicemia and expresses numerous virulence factors, in which luxS and smcR are genes encoding for components responsible for quorum-sensing regulation. In the present study, null mutants were constructed with lesions in each or both of these two genes from the V. vulnificus Vv$\Delta$Z strain, which is a lacZ$^{-}$ and chloramphenicol/streptomycin-resistant derivative of the wild-type ATCC29307 strain, and their phenotypes related to virulence were compared with those of the parental cells. $LD_{50}$ and histopathological findings of luxS-, smcR-, or luxS- smcR- deficient mutant were not different from those of the parent strain, a lacZ-deficient streptomycin-resistant strain in mice. However, time of death in mice was delayed, and numbers of bacteria survived in bloodstream after intraperitoneal injection in mice were decreased by mutation, especially luxS and smcR double mutant (VvSR$\Delta$ZSR). These phenomena were supported by increased serum sensitivity and delayed bacterial proliferation in both murine blood and iron-restricted medium. These results suggest that the luxS and luxR homologous genes in V. vulnificus could playa role in bacterial survival in host by enhancing proliferation and adjusting to changed environment.

An Optochemical Sensor for the Determination of Divalent Transition Metal Ions Based on a Reactive Dye (반응성 염료를 이용한 2가 전이금속 측정용 광센서)

  • Kim, Sung Bae;Lee, Hyuk Jin;Kim, Jin Mog;Shin, Doo Soon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.305-310
    • /
    • 1998
  • A reactive dye synthesized with an amine containing Eriochrome Black T derivative and cynauric chloride was immobilized on a cellulose membrane to construct an optical sensor for the detection of divalent transition metal ions in aqueous solution. The response of this reactive dye-based optical sensor was as sensitive as that of Eriochrome Black T in solution phase. Its typical detection limits for $Zn^{2+}$ and $Co^{2+}$ were $6.3{\times}10^{-5}mol/l$ and $2.5{\times}10^{-4}mol/l$, respectively. No loss in the sensitivity of reactive dye-based sensor was observed even the pH of flowing solutions continually varied for an extended period of time.

  • PDF

Influence of UV-B Radiation on Photosynthesis, Growth and Pigmentation of Chondrus ocellatus (Rhodophyta) from Shallow Water

  • Taejun Han;Han, Young-Seok;Cho, Man-Gee;Park, Jin-Hee;Goo, Jae-Gun;Kang, Sung-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.4
    • /
    • pp.368-376
    • /
    • 2003
  • The UV-B sensitivity was tested for the intertidal species Chondrus ocellatus from Korea, by measuring photosynthesis estimated as effective quantum yield ($\Phi_{PSII}$) of photosystem II (PS II), growth and content and composition of photosynthetic pigments and UV-absorbing pigments (UVAPs). The $$\Phi_{PSII}$ of the alga decreased with increasing time of exposure to UV-B radiation, followed by fast and nearly full recovery indicating dynamic photoinhibiton. Fresh weight-based growth and pigment contents of C. ocellatus were not seriously affected by UV-B radiation. A single broad peak at 327 nm was obtained from methanol extracts of C. ocellatus, and the absorbance peak increased with increasing UV. The single peak was resolved into three peaks (311, 330 and 336 nm) by the fourth -derivative, and quantitative change in response to UV-B radiation occurred only at 330 nm. High performance liquid chromatography (HPLC) analysis of purified extracts indicated that three MAAs (mycosporine-like amino acids) are present, asterina 330, palythine and shinorine. Field observations during three growing months showed that C. ocellatus exhibit the highest amount of UVAPs in May followed by July and little trace in September, coinciding with the species' phenology. In an ecological context, dynamic photoinhibition as well as accumulation of UVAPs may enable the shallow water red alga C. ocellatus to be well adapted to high UV-B environments.

Deformation Measurement of Well Thinning Elbow by Using Shearography (전단간섭법을 이용한 감육 곡관부의 변형 계측)

  • Jung, Hyun-Chul;Kim, Koung-Suk;Chang, Ho-Sub;Jung, Sung-Wook;Kang, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.321-328
    • /
    • 2006
  • In this study, the deformation oi wall thinning elbow is measured and the position of the internal thinning defect is found out by shearography. Shearography is an optical method which has applied to nondestructive testing (NDT) and the strain/stress and deformation analysis. This technique has the merit of the directly measuring the first derivative of displacement with sensitivity which can be adjusted by handling the tilt mirror in the interferometer. In this paper, we tested carbon steel pipe locally wall thinned and loaded internal pressure and the shearography was applied to measure the out-of-plane deformation of wall thinning elbow and to investigate the internal thinning defect of it. From the results, it was confirmed that this technique is proper to the practical application on the pipe line system with internal defect.