• 제목/요약/키워드: Sensitivity Axis

검색결과 220건 처리시간 0.022초

교류 자기센서 특성 시험장치 설계에 관한 연구 (A Study on the Measurement System Design for Measuring Properties of AC Magnetic Field Sensor)

  • 정현주;양창섭;정우진
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.244-252
    • /
    • 2015
  • This paper describes design and construction results of the measurement system developed on the purpose of measuring properties of AC magnetic field sensors used in the weapon system. The system for measuring the properties of AC magnetic field sensors consist of 3-axis helmholtz coil, signal generator, signal amplifier, sensor data acquisition unit and AC magnetic field sensor property measurement & analysis equipment including the operating software. By using this system, we can measure various properties of AC magnetic field sensor such as sensitivity, linearity and dynamic response in the frequency from 1 Hz to 10 kHz. Finally we also verified its performance by measuring the property of a MAG 639, standard magnetic field sensor of bartington instruments, with the developed measurement system.

3축 가속도 센서를 이용한 자세 교정 유도 시스템 (Correct Posture Guidance System using 3-axis Acceleration Sensor for Scoliosis Patient)

  • 안양수;김거식;서정환;송철규
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.220-224
    • /
    • 2010
  • In this study, we designed a device for consecutively observing position, utilizing 3-axises acceleration sensor. This method offer to check his or her wrong position and developed could to help derived a position appliance. And, we developed a Cobb's angle value in three dimensional using 3-axises acceleration sensor. A proposed device with integrated accelerometers, which can detect postural changes in terms of curvature variation of the spine in the sagittal and coronal planes, has been developed with intention to facilitate posture training. The proposed device was evaluated with 3 normal subjects daily activities. We evaluated the performance of our designed device as calculating the correlation coefficients and mean errors between the angle measured by an electro-goniometer and that estimated by a gravity accelerometer and verified the accuracy and sensitivity. The results showed that the angle obtained from the proposed device revealed a linear characteristic at the range of $\pm60^{\circ}$(correlation coefficient 0.99, error range $\pm2^{\circ}$). We demonstrated that our device could detect the changes of the motion in upper trunk accurately. Also, our device showed good potential for treatment of the patients with scoliosis and prevention of the unbalance position during a daily life.

3축-가속도 센서를 이용한 배례(拜禮)동작 모니터링 및 자동검출 시스템 설계 (Design of Bowing-Activity Monitoring and Automatic Detection System Using 3-Axis Accelerometer)

  • 이영재;이필재;차지영;선우섭;황진상;이정환
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1150-1158
    • /
    • 2010
  • In this paper, a new reliable portable activity monitoring device implemented with the buddhist-style bowing activity and walking step detection algorithm, is presented. In order to monitor the bowing and walking activities, miniaturized 3-axis accelerometer sensor with the sensitivity of 800 mV/g was used. After initial signal conditioning, vector magnitude of accelerometer signals was calculated. Syntactic peak detection method was used in order to feature points. All signal processing algorithms were implemented in ultra-low power microcontroller MSP430 with double precision floating point arithmetic. For evaluation, 19 young man($24.22\pm5.22$ yrs) and woman($22.28\pm2.72$ yrs) were involved. The accuracy of the proposed algorithms were 98.91 %($\pm0.011$) for walking step detection and 98.25 %($\pm0.023$) for buddhist-style bowing activity. Comparing to the commercialized pedometer accuracy, 87.1 %($\pm0.058$), the proposed walking step detection algorithms show more reliable accuracy.

3축 구동이 가능한 Slim형 Pick-Up Actuator 개발 및 동특성 분석 (A Study on Dynamic Characteristics of 3-axis Actuator for the Slim Type Pick-Up)

  • 박관우;서민석;홍삼열;김영중;최인호;김진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.373-377
    • /
    • 2002
  • In this study, we suggested a slim-type actuator that can be controlled in radial direction for compensating coma aberration in high-capacity optical storage devices. To deal successfully with narrow space in slim-type optical pick-up for notebook pc device, additional yokes for tilting motion are integrated into main yoke of the actuator. And the location of tilting coils is determined for mass-b3lancing effect to achieve optimal configuration for high driving sensitivity. We also suggested new concept of lens holder to guarantee excellent stability of control system by enhancing the gain margin at secondary resonant frequency. The concept was realized by forming damping sections in the lens holder, which prevent vibrational energy from transferring to lens. An exclusive measurement system was newly developed for fast and precise measurement of dynamic characteristics of actuators and utilized for the practical use. We hope to make good use of this system also in time to come.

  • PDF

GM 및 종경사 변경에 따른 선박의 조종성능변화에 관한 실험적 연구 (An Experimental Study on the Manoeuvrability of a Ship in Different GM and Trim Conditions)

  • 윤근항;김동진;여동진
    • 대한조선학회논문집
    • /
    • 제57권4호
    • /
    • pp.230-240
    • /
    • 2020
  • The aim of this study was to investigate the manoeuvrability of a ship in different Center of Gravity (CG) conditions. Free Running Model Tests (FRMT), such as 35°turning circle tests, 20/20 zigzag manoeuvring tests, and 10/10 zigzag manoeuvring tests, were conducted in three GM and three trim conditions with 1/65.83 scaled KRISO Container Ship (KCS). The test results indicated that KCS in the lower GM condition and the trim by bow condition showed reduced advance and tactical diameter in turning circle tests and increased overshoot angles in zigzag tests, and those manoeuvring indices were strongly related with roll angle. In addition, sensitivity indices for three-axis CG position were suggested with prior research, and it showed that y-axis CG position significantly affected manoeuvrability of KCS due to the low GM. Therefore, in the case of KCS, it is evident that the roll angle during manoeuvre is closely related with manoeuvring indices.

파킨슨병 환자의 보행동결 검출을 위한 시간영역 알고리즘 (Time Domain of Algorithm for The Detection of Freezing of Gait(FOG) in Patients with Parkinson's Disease)

  • 박상훈;권유리;김지원;엄광문;이재호;이정환;이선민;고성범
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권4호
    • /
    • pp.182-188
    • /
    • 2013
  • This study aims to develop a practical algorithm which can detect freezing of gait(FOG) in patients with Parkinson's disease(PD). Eighteen PD patients($68.8{\pm}11.1yrs.$) participated in this study, and three($68.7{\pm}4.0yrs.$) of them showed FOG. We suggested two time-domain algorithms(with 1-axis or 3-axes acceleration signals) and compared them with the frequency-domain algorithm in the literature. We measured the acceleration of left foot with a 3-axis accelerometer inserted at the insole of a shoe. In the time-domain method, the root-mean-square(RMS) acceleration was calculated in a moving window of 4s and FOG was defined as the periods during which RMS accelerations located within FOG range. The parameters in each algorithm were optimized for each subject using the simulated annealing method. The sensitivity and specificity were same, i.e., $89{\pm}8%$ for the time-domain method with 1-axis acceleration and were $91{\pm}7%$ and $90{\pm}8%$ for the time-domain method with 3-axes acceleration, respectively. Both performances were better in the time-domain methods than in the frequency-domain method although the results were statistically insignificant. The amount of calculation in the time-domain method was much smaller than in the frequency-domain method. Therefore it is expected that the suggested time domain algorithm would be advantageous in the systematic implementation of FOG detection.

입사광의 단락된 정도에 따른 광학계의 색도 변화 (The Variation in Chromaticity of Optical System having the Truncated Incident Beam)

  • 박성종;정창섭;심상현
    • 한국안광학회지
    • /
    • 제5권1호
    • /
    • pp.13-18
    • /
    • 2000
  • 본 논문에서는 다색 광원으로 대낮의 햇빛(daylight)을 표현하는 C광원을 사용하였으며, 입사광으로는 가우시안 형태의 진폭을 갖는 광을 고려하였다. 고려된 C광원에서 가우시안 진폭을 갖는 입사광의 단락된 정도에 따른 광학계의 상면과 축상의 조도(illuminance) 분포와 색도(chromaticity) 변화를 조사하였다. 이때 색감각 함수는 1931년 CIE 자료를 사용하였으며, 고려한 파장은 380nm에서 780nm까지이다. 본 연구에서 고려된 가우시안 진폭을 갖는 입사광의 단락된 정도가 증가할수록 상면에서 중심 spot의 크기가 작아졌으며, 축상에서의 초점 심도가 작아졌다. 색도 변화는 상면과 축상에서 단락된 정도가 증가할수록 심하게 변화하였으며, 조도의 세기가 중앙 극대점에서 점차 감소할수록 광학계의 색도 변화가 심해졌다. 또한 초점 심도가 증가할수록 광학계의 색도 변화가 작게 나타났다.

  • PDF

레이저 빔의 파면 측정을 통한 비축 포물 거울의 성능 평가 및 정렬 오차 민감도에 관한 연구 (Measurement of Wavefront Aberrations in Off-Axis Parabolic Mirrors and its Dependence on the Misalignment)

  • 정태문;최일우;고도경;이종민
    • 한국광학회지
    • /
    • 제17권3호
    • /
    • pp.256-261
    • /
    • 2006
  • 본 논문에서는 비축 포물 거울을 통과한 레이저 빔의 파면을 측정하는 방식으로 국내 및 국외에서 제작된 비축 포물 거울을 평가하였으며, 이로부터 비축 포물 거울의 집속 성능 및 정렬 민감도를 측정하였다. 국외에서 제작된 비축 포물 거울은 직경 약 34 mm의 레이저 빔에 대해 고차 파면 수차(higher-order aberration)의 rms 값이 $0.03{\mu}m$ 정도로 작아 광학적으로 좋은 품질을 갖는 것으로 판명되었다. 국내에서 제작된 비축 포물 거울은 같은 34 mm의 레이저 빔에 대해 고차 파면 수차의 rms 값이 $2.01{\mu}m$나 관측되어 아직 개선이 필요한 것으로 보인다. 또한, 비축 포물 거울의 회전 정렬 오차에 대한 비점수차(astigmatism)의 민감도를 측정한 결과 회전 정렬 오차에 대한 비점수차의 민감도는 $0.371{\mu}m/mrad$인 것으로 관측되었다. 이는 광선 추적 소프트웨어를 사용하여 계산한 값과 거의 같은 양으로 이러한 비점수차의 정렬 민감도 측정은 비축 포물 거울을 정렬하는데 도움을 줄 것으로 생각된다.

Thallium-201 심근 단층영상의 정량적 분석 (Quantitative Analysis of Thallium-201 Myocardial Tomograms)

  • 김상은;남기병;최창운;최기준;이동수;손대원;안규리;정준기;이명묵;이명철;박영배;최윤식;서정돈
    • 대한핵의학회지
    • /
    • 제25권2호
    • /
    • pp.165-176
    • /
    • 1991
  • The purpose of this study was to assess the ability of quantitative Tl-201 tomography to identify and localize coronary artery disease (CAD). The study population consisted of 41 patients (31 males, 10 females; mean age $55{\pm}7$ yr) including 14 with prior myocardial infarction who underwent both exercise Tl-201 myocardium SPECT and coronary angiography for the evaluation of chest pain. From the short axis and vertical long axis tomograms, stress extent polar maps were generated by Cedars-Sinai Medical Center program, and the % stress defect extent (SDE) was quantified for each coronary artery territory. For the purpose of this study, the coronary circulation was divided into 6 arterial segments, and the "myocardial ischemic score" (MIS) was calculated from the coronary angiogram. Sensitivity for the detection of CAD ($\geq50%$ coronary stenosis by angiography) by angiography) by stress extent polar map was 95% in single vessel disease, and 100% in double and triple vessel deseases. Overall sensitivity was 97%. Sensitivity and specificity for the detection of individual diseased vessels were, respectively, 87% and 90% for the left anterior descending artery (LAD), 36% and 93% for the left circumflex artery (LCX), and 71% and 70% for the right coronary artery (RCA). Concordance for the detection of individual diseased vessels between the coronary angiography and stress polar map was fair for the LAD (kappa=0.70), and RCA (kappa=0.41) lesions, whereas it was poor for the LCX lesions (kappa : 0.32). There were siginificant correlations between the MIS and SDE in LAD (rs=0.56, p=0.0027), and RCA territory (rs=0.60, p=0.0094). No significant correlation was found in LCX territory. When total vascular territories were combined, there was a significant correlation between the MIS and SDE (rs=0.42, p=0.0116). In conclusion, the quantitative analysis of Tl-201 tomograms appears to be accurate for determining the presence and location of CAD.

  • PDF

한국판 정신장애 진단 선별 질문지의 표준화 연구 (Study on Standardization of Korean Version of Psychiatric Diagnostic Screening Questionnaire(K-PDSQ))

  • 최형근;정성원;조현주;김정범;정철호
    • 대한불안의학회지
    • /
    • 제9권1호
    • /
    • pp.31-37
    • /
    • 2013
  • 정신장애 진단선별 질문지(PDSQ)는 임상에서 흔하게 진단되는 DSM-IV 축 1의 장애를 평가하기위해 고안된 최초의 자기보고식 질문지이다. PDSQ는 포괄적인 평가가 가능하고, 공존질환을 평가 할 수 있으며 신뢰도와 타당도가 높은 것으로 알려져 있다. 이 연구는 K-PDSQ의 표준화를 위한 연구로서, K-PDSQ와 M.I.N.I.-Plus의 비교를 통해 K-PDSQ의 진단적 타당성과 유용성을 검증하고자 하였다. 계명대학교 동산병원 정신건강의학과를 방문한 외래와 입원환자 640명을 대상으로 K-PDSQ와 M.I.N.I.-Plus의 진단적 일치도, K-PDSQ의 시행시간, 민감도 및 특이도를 산출하였다. K-PDSQ와 M.I.N.I.-Plus의 Cohen's kappa계수는 .66로 일치도가 높게 나타났고, K-PDSQ의 시행 소요시간은 $18.2{\pm}11.80$분이었다. 타당도에 있어 국내 환자군 대상으로 산출된 절단점을 적용하였을 때 높은 수준의 민감도와 특이도를 나타냈다. 대부분의 하위척도에서 수용자 작업특성 곡선(ROC)이 대각선 위에 있었고 곡선아래 영역(AUC) 값이 .80 이상으로 선별검사로서 유용성이 입증되었다. K-PDSQ는 M.I.N.I.-Plus와 상당한 진단적 일치도를 보였고, 시행시간이 짧고, 민감도와 특이도에서 높은 수준을 보였다. 따라서 K-PDSQ는 외래 진료환경에 적용하여 임상면담 이전에 환자에 대한 진단적 평가와 공존질환을 선별해내는데 큰 도움이 될 것으로 생각된다.