• Title/Summary/Keyword: Sensing current

Search Result 1,077, Processing Time 0.031 seconds

Numerical Signal Prediction and Calibration Using the Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Slug Flow (슬러그 2상유동에서 전류형식 전자기유량계 수치적 신호예측 및 보정)

  • Ahn Yeh-Chan;Oh Byung Do;Kim Jong-Rok;Kim Moo Hwan;Kang Deok-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.671-686
    • /
    • 2005
  • The transient nature and complex geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et al.). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. The velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method, and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for simulating slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are proposed for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

The Study on The Skil Development of Optical CT Using Faraday Effects (Faraday효과를 이용한 광CT 기술 개발 연구)

  • Jeon, Jea-Il;Ahn, Mi-Kyoung;Park, Won-Zoo;Lee, Kwang-Sik;Kim, Jung-Bae;Kim, Min-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.109-113
    • /
    • 2004
  • In this paper, we took the basic experiment in order to explore the optical CT(optical current transformer) for measuring high current in a superhigh voltage condition. It is based on the faraday effect that changes the polarization characteristic of optical signals by the magnetic field. We used 1310[nm] laser diode for a light source and comprised a sensing part with the optional fiber of 5[m], 10[m], 20[m] length each. The range of current was from 400[A] to 1300[A]. We observed the characteristic of output that changes according to the length of the optical fiber composing the sensing part. The optical fiber of 5[m] length used for the sensing part had -11.1% of the maximum ratio of error and 10[m] and 20[m] length had -3.5% and 1.7% each. This means that the power and linearity of output increase in proportion to the length of optical fiber and applied current in the same experimental condition.

Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow (슬러그류 액상속도 측정용 전류형식 전자기유량계 개발)

  • Kang, Deok-Hong;Ahn, Yeh-Chan;Kim, Jong-Rok;Oh, Byung-Do;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF

Investigation of Feasibility of Tunneling Field Effect Transistor (TFET) as Highly Sensitive and Multi-sensing Biosensors

  • Lee, Ryoongbin;Kwon, Dae Woong;Kim, Sihyun;Kim, Dae Hwan;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.141-146
    • /
    • 2017
  • In this letter, we propose the use of tunneling field effect transistors (TFET) as a biosensor that detects bio-molecules on the gate oxide. In TFET sensors, the charges of target molecules accumulated at the surface of the gate oxide bend the energy band of p-i-n structure and thus tunneling current varies with the band bending. Sensing parameters of TFET sensors such as threshold voltage ($V_t$) shift and on-current ($I_D$) change are extracted as a function of the charge variation. As a result, it is found that the performances of TFET sensors can surpass those of conventional FET (cFET) based sensors in terms of sensitivity. Furthermore, it is verified that the simultaneous sensing of two different target molecules in a TFET sensor can be performed by using the ambipolar behavior of TFET sensors. Consequently, it is revealed that two different molecules can be sensed simultaneously in a read-out circuit since the multi-sensing is carried out at equivalent current level by the ambipolar behavior.

A Study on Electric Safety Control Device for Prevention of Over Current and Short Circuit Faults (과전류 및 단락사고 방지용 전기안전 제어장치에 관한 연구)

  • Jo, Si-Hwan;Kwak, Dong-Kurl;Jung, Do-Young;Shim, Jae-Sun;Kim, Jung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2100-2101
    • /
    • 2008
  • This paper is studied on a protective control system for electrical fire and electrical faults due to over current or electric short circuit faults by using electrical thermal characteristics of PTC (Positive Temperature Coefficient) thermistor and current response characteristics of high sensitive reed switch. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with BaTiO3_Ceramics of positive temperature coefficient. Also PTC thermistor shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point, and reed switch, which is used for electrical fault current sensing devices, have a excellent characteristic of response velocity in degree of ${\mu}s{\sim}ms$ that sensing magnetic flux in proportion to dimension of line current. This paper is proposed on a protective control system use PTC thermistor and reed switch for sensor which is protected from electrical fire due to overload faults or electric short circuit faults. Some experimental results of the proposed electric safety control device are confirmed to the validity of the analytical results.

  • PDF

Array Sensing Using Electromagnetic Method for Detection of Smelting in Submerged Arc Furnaces

  • Liu, WeiLing;Han, XiaoHong;Yang, LingZhen;Chang, XiaoMing
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.322-329
    • /
    • 2016
  • In this paper, we propose an array sensing detection method for smelting of submerged arc furnaces (SAF) based on electromagnetic radiation. AC magnetic field generated by electrode currents and molten currents in the furnace is reflected outside of the furnace. According to the spatial distribution of electromagnetic field a radiation model of SAF is built. We design a 3D magnetic field sensing array system in order to collect the magnetic field information. Through the collected information, the current distribution characteristics of SAF are described and the key parameters of smelting are obtained. Theoretical simulation and field test show that the curves acquired by the sensing array can accurately reflect the information of the relative displacement when the relative displacement between the array and electrode is 10 cm. Compared with the detection method of 3D single point, the proposed array sensing method of magnetic field obtains better results in terms of real-time and accuracy, and has good practical value for industrial measurement.

Derivation of SST using MODIS direct broadcast data

  • Chung, Chu-Yong;Ahn, Myoung-Hwan;Koo, Ja-Min;Sohn, Eun-Ha;Chung, Hyo-Sang
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.638-643
    • /
    • 2002
  • MODIS (MODerate-resolution Imaging Spectroradiometer) onboard the first Earth Observing System (EOS) satellite, Terra, was launched successfully at the end of 1999. The direct broadcast MODIS data has been received and utilized in Korea Meteorological Administration (KMA) since february 2001. This study introduces utilizations of this data, especially for the derivation of sea surface temperature (SST). To produce the MODIS SST operationally, we used a simple cloud mask algorithm and MCSST algorithm. By using a simple cloud mask algorithm and by assumption of NOAA daily SST as a true SST, a new set of MCSST coefficients was derived. And we tried to analyze the current NASA's PFSST and new MCSST algorithms by using the collocated buoy observation data. Although the number of collocated data was limited, both algorithms are highly correlated with the buoy SST, but somewhat bigger bias and RMS difference than we expected. And PFSST uniformly underestimated the SST. Through more analyzing the archived and future-received data, we plan to derive better MCSST coefficients and apply to MODIS data of Aqua that is the second EOS satellite. To use the MODIS standard cloud mask algorithm to get better SST coefficients is going to be prepared.

  • PDF

Design and performance validation of a wireless sensing unit for structural monitoring applications

  • Lynch, Jerome Peter;Law, Kincho H.;Kiremidjian, Anne S.;Carryer, Ed;Farrar, Charles R.;Sohn, Hoon;Allen, David W.;Nadler, Brett;Wait, Jeannette R.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.393-408
    • /
    • 2004
  • There exists a clear need to monitor the performance of civil structures over their operational lives. Current commercial monitoring systems suffer from various technological and economic limitations that prevent their widespread adoption. The wires used to route measurements from system sensors to the centralized data server represent one of the greatest limitations since they are physically vulnerable and expensive from an installation and maintenance standpoint. In lieu of cables, the introduction of low-cost wireless communications is proposed. The result is the design of a prototype wireless sensing unit that can serve as the fundamental building block of wireless modular monitoring systems (WiMMS). An additional feature of the wireless sensing unit is the incorporation of computational power in the form of state-of-art microcontrollers. The prototype unit is validated with a series of laboratory and field tests. The Alamosa Canyon Bridge is employed to serve as a full-scale benchmark structure to validate the performance of the wireless sensing unit in the field. A traditional cable-based monitoring system is installed in parallel with the wireless sensing units for performance comparison.

A New Simple Sensorless Control Method for Switched Reluctance Motor Drives

  • Xin Kai;Zhan Qionghua;Luo Jianwu
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.52-57
    • /
    • 2006
  • In this paper, a new 'impedance sensing' method is described. This method overcomes the shortcomings of the impedance sensing method. According to the new method, sensing voltage pulse is applied to the idle phase in the minimum inductance region and the beginning of the increasing inductance region to detect rotor position. The negative torque produced by the sensing voltage pulse can be neglected in the minimum inductance region and the efficiency of SRM is improved. In the minimum inductance region the back electromotive force (EMF) can be neglected. And in the increasing inductance region the EMF opposes the rise of current in the phase, so the position estimation scheme is reliable. Therefore the new 'impedance sensing' method is sufficiently precise even under the high back EMF effect. The adjustment of turn-on angle and turn-off angle is also easy to be realized. The technique is very useful in applications where cost or size is primary concerns, such as electric bicycle drives. Experimental results are presented to verify the proposed method.

Research on Key Technologies of UAV Remote Sensing Operation Systems

  • Yan, Lei;Lu, Shuqiang;Zhang, Xuehu;Zhao, Hongying;Yang, Shaowen;Zhao, Jicheng;Li, Peijun;Wang, Kedong;Yao, Yuanhong
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1377-1379
    • /
    • 2003
  • Satellite and aerial remote sensing (RS) techniques have been provided to collect spatial data globally over the last few decades. However in developing countries such as China, there is still an urgent need for low cost and high resolution RS data. As an emerging RS platform, commercial Unmanned Aerial Vehicle (UAV) integrated with state-of-the-art sensors and information technologies has the potential to become a low cost tool to meet application demands. In this paper, the architecture of UAV RS operation system is mentioned. Moreover, key technologies in UAV RS system are analyzed and current work is reported.

  • PDF