• Title/Summary/Keyword: Sensible heat storage

Search Result 52, Processing Time 0.028 seconds

A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit (충진층 현열 축열조의 성태해소에 관한 연구)

  • Kwon, Sun-Seok;Kim, Si-Beom;Gu, Bon-Yeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

  • PDF

A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit (충진층 현열 축열조의 성태해소에 관한 연구)

  • Kwon, Sun-Seok;Kim, Si-Beom;Gu, Bon-Yeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.235-235
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

Exergy analysis on the storage performance of the sensible heat storage unit (현열 축열조의 성능에 관한 엑서지 해석)

  • 김시범;권순석
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.176-182
    • /
    • 1988
  • The exergy analysis on the heat storage performance of the senible heat storage unit which consists of the heat storage material in the concentric annulus and the hot fluid flowing through the inner tube is performed. Heat transfer characteristics which are necessary for the performance of the exergy analysis is obtained from the energy balance equations and the second law of thermodynamics. As the index of heat storage performance, the exergy lossnumber $N_{s}$, and exergy storage ratio from the concepts of the second law of thermodynamics are defined. Results are ovtained for the grometry of the storage unit, the Biot number Bi, ambient temperature $T_{o}$ as parameters. From these results the exergy storage ratio can be considered as the efficiency of the hat storage unit and is introduced as a guide to design.

  • PDF

Experimental Study on Zeolite 13x for Thermochemical Heat Storage (제올라이트를 이용한 화학축열에 대한 실험적 연구)

  • Ha, Seungho;Park, Junghoon;Lee, Soohun;Kim, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.429-436
    • /
    • 2017
  • There are three main methods to store heat energy; sensible heat storage, latent heat storage, and thermochemical heat storage. Thermochemical heat storage has the highest storage density among the three methods, so this study focused on the thermochemical heat storage method. Experiments were conducted in this study with Zeolite 13x as thermochemical material in a large-scale reactor with 8 kg of Zeolite 13x. Experiments analyzed storage density of Zeolite 13x with respect to four different heating temperatures ($50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$) in heat storage process. As a result, they showed 40~50 percent of storage efficiency in the experiment. Experiments also revealed that reactions between Zeolite 13x and water vapor were reversible and stable, but efficiency of the system was low, compared with sensible heat storage systems or latent heat storage systems.

Performance Comparison of an Urban Canopy Model under Different Meteorological Conditions (기상 조건에 따른 도시 캐노피 모형의 성능 비교)

  • Ryu, Young-Hee;Baik, Jong-Jin;Lee, Sang-Hyun
    • Atmosphere
    • /
    • v.22 no.4
    • /
    • pp.429-436
    • /
    • 2012
  • The performances of the Seoul National University Urban Canopy Model (SNUUCM) under different meteorological conditions (clear, cloudy, and rainy conditions) in summertime are compared using observation dataset obtained at an urban site. The daily-averaged net radiation, sensible heat flux, and storage heat flux are largest in clear days and smallest in rainy days, but the daily-averaged latent heat flux is similar among clear, cloudy, and rainy days. That is, the ratio of latent heat flux to net radiation increases in order of clear, cloudy, and rainy conditions. In general, the performance of the SNUUCM is better in clear days than in cloudy or rainy days. However, the performance in simulating sensible heat flux in clear days is as poor as that in rainy days. For all the meteorological conditions, the performance in simulating latent heat flux is worst among the performances in simulating net radiation, sensible heat flux, and latent heat flux. The normalized mean error for latent heat flux is largest in rainy days in which the relative importance of latent heat flux in the surface energy balance becomes greatest among the three conditions. This study suggests that improvements to the parameterization of processes that are related to latent heat flux are particularly needed.

Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage - (낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 -)

  • Kim, Seong-Rak;Cho, Chang-Bum;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

A Study on the Heat-Storage/-Release Characteristics of a Regenerative Heat Exchanger Utilizing the Reversible Thermochemical Reaction of $Ca(OH)_2/CaO$ ($Ca(OH)_2/CaO$ 계의 가역 열화학 반응열을 이용한 축열식 열교환기의 축열 및 방열특성에 관한 연구)

  • Lee, Soo-Kag;Kim, Hong-Jea;Lee, Jin-Kook
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.22-30
    • /
    • 1989
  • Since the energy storage method by means of the thermochemical reaction has no heat loss by separating the reactants under the storage period, it is remarked as one of promising means particularly for long-term heat storage. In this study, the heat-storage/-release characteristics of the reversible chemical reaction cycle, $Ca(OH)_2/CaO$, is numerically analysed by a mathematical modelling. As a result, the effectiveness of the heat exchanger by the chemical heat storage method is considerably higher than that by the sensible heat storage method. It is found that the major parameters, which determines the effectiveness of the heat exchanger, are the mass flow rate and inlet temperature of fluid, the residence time, etc.. The heat-storage/-release period can be controlled by changing the operation conditions. It is expected that the results obtained here will supply useful informations in designing a regenerative heat exchanger utilizing the thermochemical reaction.

  • PDF

Floor Heating Characteristics of Latent Heat Storage - Bioceramic Ondol - Focused on Theoretical Analysis - (잠열 축열 - 바이오 세라믹 온돌의 난방 특성 - 이론적 분석을 중심으로 -)

  • 송현갑;유영선
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.213-222
    • /
    • 1995
  • Korean traditional Ondol with the sensible heat storage medium has been for a long time used as residential heating system, in these days the concrete Ondol without the heat storage medium was realized as the heating system in the private houses and the apartments. This floor heating system is good for our health. But the concrete Ondol is not desirable for the energy saving and for the maintenance of comfortable room temperature because the heat storage medium is not employed in the concrete Ondol. And as the hot water circulating pipes ate buried under the the concrete floor, the concrete Ondol system has some kind of problems to be improved. Therefore the new type of Ondol system was developed in this study. And the new Ondol was consisted of latent heat storage material as heat storage medium with a great heat capacity and bioceramics as medium to maintain comfortable room temperature. In this study, the heat transfer characteristics of latent heat storage-bioceramic Ondol was analyzed theoretically.

  • PDF

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 -)

  • Sone, Hyun-Kap;Ryon, Young-Sun
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.13-28
    • /
    • 1995
  • In this study, the history of Korean traditional Ondol was investigated and the latent heat materials and bioceramics were selected to develop the latent heat storage-bioceramics Ondol system based on the Korean traditional Ondol(sensible heat storage type), and the thermal characteristics of Ondol were analyzed experimentally The results could be summarized as follows; 1. Korean traditional Ondol has been originated in "Whaduk" which had been utilized continuously for about $2{\times}10^6$ years from the Old Stone Age to the Bronze Age, and Korean traditional Ondol using in these days has been utilized for about 976 years from the Koryu Dynasty to the Modern Ages. 2. $Na_2SO_4{\cdot}10H_2O(SSD)$ was selected as latent heat material for the latent heat storage Ondol. 3. Ondol unit was filled with the latent heat material of 0.63 kg and the dimension of Ondol unit was $400mm{\times}400mm{\times}27mm(width{\t\imes}depth{\times}height)$. 4. The comfortable surface temperature($23{\sim}29^{\circ}C$) of the latent heat storage Ondol was lasted 5 hours at the room temperature of $16{\sim}18^{\circ}C$, whereas that of sensible heat storage Ondol was lasted only 1.0 hours in the same conditions. 5. For the thermal effect of bioceramics, the Ondol air temperature i.n case of bioceramics treatment on the pannel was higher than that of without bioceramics treatment.

  • PDF

Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994 (제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우-)

  • 김해동;양성기
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF