• Title/Summary/Keyword: Semi-Squat

Search Result 13, Processing Time 0.025 seconds

Analysis of Patellar Tracking and Q-angle During Semi-Squat Exercises (반 쪼그려 앉기(Semi-Squat) 운동 시 무릎뼈 주행(Tracking)과 Q-각도 분석)

  • Park, Seung-Kyu;Yang, Dae-Jung;Park, Jae-Man;Han, Song-E
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.107-114
    • /
    • 2011
  • Closed kinematic chain exercises such as squatting have been widely indicated for knee rehabilitation in patients with patellofemoral disorders such as osteoarthritis and patellofemoral pain. Patellofemoral disorders are thought to be associated with abnormal patellar kinematics. In addition, the Q-angle may be undervalued in patients with patellofemoral pain and a laterally displaced patella. The purpose of this study was to assess patellar kinematics and the Q-angle during double-leg semi-squat and wall-slide semi-squat exercises. In this study, 28 asymptomatic subjects(16 male, 12 female) were assessed. Patellar tilt, patellar spin, and Q-angle were recorded using a motion analysis system during double-leg semi-squat and wall-slide semi-squat exercises. The Q-angle and patellar tilt were significantly increased, whereas patellar spin was significantly decreased, at $45^{\circ}$ of knee flexion compared with $0^{\circ}$. No differences were observed for the Q-angle, patellar tilt, and patellar spin during double-leg semi-squat and wall-slide semi-squat exercises. However, a significant interaction was observed between squat type and knee angle for patellar spin. We found that the patella is laterally tilted during semi-squat exercises and that there was no difference in patellar tracking between knee flexion during double-leg semi-squat and wall-slide semi-squat exercises.

Comparison of the Muscle Activity of Lumbar Stabilizers Between Stoop and Semi-Squat Lifting Techniques at Different Lifting Loads

  • Yang, Hoe-Song;Kwon, Oh-Yun;Lee, Yeon-Seop
    • Physical Therapy Korea
    • /
    • v.19 no.3
    • /
    • pp.105-114
    • /
    • 2012
  • This study was performed to compare the muscle activity of lumbar stabilizers between stoop and semi-squat lifting techniques at different lifting loads. Twenty healthy subjects (9 males, 11 females) were recruited for this study. Muscle activity of external obliques (EO), internal obliques (IO) and lumbar multifidus (LM) muscle was measured by surface electromyography during stoop and semi-squat lifting at different lifting loads (10%, 20%, and 30% of the subject's body weight). A one-way repeated measure ANOVA was applied. The results showed that EMG activity of EO was significantly increased with a load of 30% of body weight compared to 10% and 20% of body weight in both lifting techniques (p<.05). Muscle activity of LM was significantly increased in 20% compared to 10% and 30% compared to 10% of subject's body weight in stoop lifting and the muscle activity of LM was significantly increased in 20% compared to 10%, 30% compared to 20%, and 30% compared to 10% of the subject's body weight in semi-squat lifting (p<.05). However, there was no significant difference in activity of IO according to lifting loads in both lifting techniques. There were no significant differences in muscle activity of EO, IO, and LM between stoop and semi-squat technique (p>.05). Therefore, the results of this study suggested that the EO can contribute to increase the lumbar stability during stoop and semi-squat lifting at 30% of body weight rather than at lower loads, and the LM seems to act as counteractor to imposed loads during stoop and semi-squat lifting with increasing loads.

Effects of Semi-Squat Exercise on Joint Position Sense and Balance to the Types of Support Surface in Hemiplegic Patients

  • Oh, Juyeong;Kim, Joong Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.242-247
    • /
    • 2022
  • Purpose: This study investigates the effect of 60° semi-squat exercises according to three different types of support surfaces. The effects were examined on joint position sense and balancing ability using stable and unstable surfaces in patients afflicted with post-stroke hemiplegia. Methods: Subjects were instructed to perform three sets of 60° semi-squat exercises according to the characteristics of the support surface conditions. The three ground states were bilateral stable surface (BSS), nonaffected side unstable surface (NUS), and bilateral unstable surface (BUS). The joint position sense, characteristics of body sway, and dynamic balance were analyzed according to floor conditions before and after the experiment. A balance-pad (50 cm W×41 cm L×6 cm H; Alcan Airex AG, Sins, Switzerland) was used for the unstable floor. Results: The 60° semi-squat exercises applied to hemiplegic patients showed the highest statistical significance in joint position sense in the NUS group, and Timed Up and Go test (TUG) in the BUS group (p<0.05). Conclusion: Functional training using an unstable surface can be applied as a meaningful intervention method for improving the balance and joint position sense of stroke patients.

Investigating the Impact of Different Resisted Lateral Band Walking Strategies on Hip Abductor Muscle Activity

  • Sin Sil Kim;Sungbae Jo;Seung-gu Lee;Changho Song
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Objective: This study aimed to investigate the effects of squat posture, band position, and contraction type on the muscle activity of the hip abductors during resisted lateral band walking. Design: A cross-sectional survey study Methods: 24 healthy male subjects were recruited, and surface electromyography was used to measure the muscle activity of the gluteus maximus, gluteus medius, and tensor fascia lata of the dominant leg during lateral walking exercises. Resistance bands were applied to the knees, ankles, and feet in semi-squat and squat postures, and exercises were randomly performed under six different conditions. Results: The results showed significant differences in muscle activity in the gluteus maximus, gluteus medius, and tensor fascia lata according to posture, band position, and contraction type (p<0.05). The muscle activity of the hip abductors increased in the squat posture and with the band placed on the distal joint compared to the proximal joint (p<0.05). Additionally, muscle activity was higher in the eccentric contraction phase than in the concentric contraction phase (p<0.05). Contrary to previous studies, moving the resistance band from the ankle to the foot increased the muscle activity of the tensor fascia lata while the activity of the gluteus maximus and gluteus medius also increased. Conclusions: According to the results, squat posture with a resistance band placed on the feet and using an eccentric contraction phase were found to be the most effective methods for strengthening the hip abductors.

The Effect of Types of Weight-Bearing Surfaces on Muscle Activities of Lower Limbs and Weight Distribution During Semi-Squat Movement of Patients With Hemiplegia (편마비 환자의 반 쪼그려 앉기(semi-squat)동작 시 양하지 지지면의 형태가 하지 근활성도와 체중분포에 미치는 영향)

  • Yang, Yong-Pil;Roh, Jung-Suk
    • Physical Therapy Korea
    • /
    • v.19 no.1
    • /
    • pp.28-36
    • /
    • 2012
  • This study used an unstable platform to change the support surface type and position of both lower limbs in order to determine changes in weight distribution and muscle including the vastus medialis, tibialis anterior, lateral hamstring, and lateral gastrocnemius of both lower limbs were evaluated during knee joint flexing and extending in a semi-squat movement in 32 hemiplegic patients. The support surface conditions applied to the lower limbs were divided into four categories: condition 1 had a stable platform for both lower limbs; condition 2 had an unstable platform for the non-hemiplegic side and a stable platform for the hemiplegic side; condition 3 had a stable platform for the non-hemiplegic side and an unstable platform for the hemiplegic side; and condition 4 had an unstable platform for both sides. The normalized EMG activity levels of muscles and weight bearing ratio of both sides in the four surface conditions were compared using repeated measures ANOVA. A significant increase was found in the weight support distribution for the hemiplegic side in flexing and extending sessions in condition 2 compared to the other conditions (p<.05). A statistically significant decrease in significant decrease in asymmetrical weight bearing in flexing and extending sessions was observed for condition 2 compared to the other conditions (p<.05). A similar significant decrease was found in differences in muscular activity for both lower limbs in condition 2 (p<.05). The muscular activity of the hemiplegic side, based on the support surface for each muscle showed a significantly greater increase in condition 2 (p<.05). An unstable platform for the non-hemiplegic side and a stable platform for the hemiplegic side therefore increased symmetry in terms of the weight support distribution rate and muscle activity of lower limbs in hemiplegic patients. The problem of postural control due to asymmetry in hemiplegic patients should be further studied with the aim of developing continuous effects of functional training based on the type and position of the support surfaces and functional improvement.

Rerformance Evaluation of ER Suspensions Under Field Test (실차 시험을 통한 ER 현가장치의 성능평가)

  • Lee, Heon-Gyun;Choe, Seung-Bok;Han, Seung-Jik;Jang, Yu-Jin;Lee, Seong-Beom
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.347-354
    • /
    • 2000
  • This paper presents performance characteristics of a semi-active suspension featuring continuously variable ER (electro-rheological) dampers. These are evaluated through the field test of a passeng er car. Four ER dampers (two for front and two for rear part) are manufactured and their field-dependent damping properties are experimentally investigated. The damping force responses to step input fields are also identified by employing small size of high voltage amplifiers which are made adaptable to the field test. A skyhook controller considering the vertical, pitch and roll motions is formulated and incorporated with a car to be tested. The field test is then undertaken in order to evaluate both comfortability and steering stability showing bump, dive and squat responses.

High Tunable Control Algorithm for Semi-active Suspension by a Normal Type CDC Damper (연속 가변 댐퍼에 의한 반능동 현가장치의 고 자유도 제어기)

  • Choi, Ju-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.11
    • /
    • pp.1096-1103
    • /
    • 2010
  • This paper proposes CDC (Continuous Damping Control) algorithm and verifies in multi-body dynamic vehicle. In order to distinguish a road profile on driving, waviness calculated by the filtered vertical-accelerations of sprung and unsprung masses is introduced. Sky-hook control is used at a low waviness road and constant damping level control is used at a high waviness road, where the hard damping level is determined by waviness, roll rate, acceleration, and deceleration. The damping levels of ride, anti-roll, anti-squat, and anti-dive modules are calculated by tuning parameters which is dependent upon vehicle velocity. Therefore this high tunable algorithm is useful to improve the ride and handling performance under various driving conditions. In the simulations, tire and dampers are modelled by SWIFT (Short Wavelength Intermediate Frequency Tire) model and 1st order delay model, and results are compared with conventional damper's.

Development of the semi-active controlled variable damper system for passenger vehicles (승용차용 반능동형 가변댐퍼시스템의 개발)

  • 허승진;심정수;이광기;김홍석;황성호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.45-50
    • /
    • 1995
  • 본 연구에서는 기존에 널리 사용되고 있는 스카이훅 제어 알고리즘(skyhook control algorithm)[3]을 바탕으로 확장 개발된 모드 스카이훅 제어(mode skyhook control) 개념 및 주파수 감응식 제어(frequency dependent control)개념[4][5]을 실용화하기 위하여 응답속도가 20msec이하의 비교적 빠른 응답 속도를 갖는 전자기식 작동기 (electro-magnetic actuator)에 의해 가변되는 4단 반능동형 가변 댐퍼 시스템을 개발한 후, 다음과 같은 성능의 향상을 시험결과를 통하여 보이고자 한다. -저속에서의 승차감 향상과 고속에서의 주행 안정성 향상 -커브 주행 또는 급격한 핸들 작동시의 롤안정성 (rolling stability) 향상 -제동 및 급발진시의 차체 피칭 운동 방지 (anti-dive, anti-squat)

  • PDF

Effect of Exercise with Vertical Vibration on the Balance, Walking Speed, Muscle Strength and Falls Efficacy in the Elderly (수직 진동 운동이 노인의 균형, 보행속도, 근력 및 낙상효능감에 미치는 효과)

  • Park, Jin-Hwan;Kim, Young-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.131-143
    • /
    • 2020
  • PURPOSE: The purpose of this study was to determine if an exercise program with vertical vibration can improve balance, walking speed, muscle strength and falls efficacy in the healthy elderly. METHODS: A total of 28 elderly were randomly divided into two groups: vertical vibration exercise group (exercise with vertical vibration) (N = 14) and control group (exercise without vibration) (N = 14). The exercise program, comprising calf raise, deep-squat, semi-squat, front lunge, and leg abduction was conducted with or without vibration, respectively. Subjects in each group participated in the 30 minutes training program, 2 times per week for 6 weeks. In both groups, the balance evaluation system (BT4) was used to evaluate standing balance, and walking speed was measured using the 10MWT. The manual muscle test system was applied to evaluate the knee extensor and ankle planter flexor muscle strength of the subjects, whereas the Korean falls efficacy scale (K-FES) evaluated the falls efficacy. RESULTS: After intervention, the vertical vibration group showed significantly higher changes compared to the control group, in the parameters of standing balance (P < .05), 10MWT (P < .05), left knee extensor (P < .05), right knee extensor (P < .01), both ankle plantar flexors (P < .05), and K-FES (P < .05). CONCLUSION: The exercise program with vertical vibration has the potential to improve balance, walking speed, muscle power and falls efficacy in the elderly.

Design and Manufacturing of Clean Room Garments Required at Ultra Clean Environment - Based on comparative analysis of Particle Release- (고청정 작업환경에 적합한 방진복 디자인 개발 -파티클 발생량을 중심으로-)

  • 박상희;송명견
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.6
    • /
    • pp.1037-1045
    • /
    • 2001
  • This research is done to design and manufacture prototype clean room garments to improve the product yield of the clean room processing. To assist the research, other papers and references on the same subject were collected for analysis. Also the researcher made interviews with the workers at the clean room. The prototype garments made for this project was compared against the commercially available clean room garments used in the industry. A set of test was conducted to measure particle release from the garments. The prototype clean room garments was manufactured after having considered all the aspects stated above, and tested for the level of particle release. The test subjects performed 4 different movements(marching, arms stretch, squat and rise, and jogging) while wearing the prototype garments and commercially available clean room garments. Particle counts produced by each movement were measured. The data collected was statistically analyzed. The followings are the result of the test. 1) Overall, the prototype garments yielded less particle release.(p<0.001) 2) It showed greatest difference of particle counts for jogging(p<0.001) and squat and rise(p<0.001). In the arms stretch test. the prototype garments was also more effective in controling the particle, however, in the marching test. no significant difference was detected. 3) The prototype garments had less particle release in upper(p<0.001), middle(p< 0.001), and lower level(p<0.01) than the commercially available clean room garments. Manufacturing a new fabric for the clean room processing is important, but this research proves that the design of the clean room garments also determines the efficiency garments in the particle control. Therefore the same fabric can perform differently according to how it is designed. Improving the design will also improve the 7article control and reduce the cost of research. Eventually, the manufacturers will increase the product yield.

  • PDF