• Title/Summary/Keyword: Semi-Freejet

Search Result 3, Processing Time 0.023 seconds

M4 Semi-Freejet Test with Full-scale Vehicle Model (실기체급 비행체 모델에 대한 M4 준자유류 시험)

  • Juhyun Bae;Changwon Lim;Hojin Choi;Sangwook Jin;Jeongwoo Kim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.5
    • /
    • pp.63-73
    • /
    • 2022
  • Investigation on operation of the test apparatus for the M4 semi-freejet tests with a full-scale vehicle model was carried out utilizing domestic facilities. An integrated design of the experimental apparatus and the vehicle model was obtained through iterative computational fluid dynamics (CFD) analysis. The test results showed that the M4 nozzle of the apparatus was fully expanded to provide required test conditions. It was also found that the intake of the vehicle model successfully started, and the corresponding shadowgraph images were recorded during the test. A variable nozzle of the model was set to adjust the back pressure of the model combustor, and wall-static pressures were measured to obtain the pressure distribution at the main locations of the model. The flame of torch ignitors and pilot fuel ignition were observed in a flame-holder of the combustor.

Cold Test and Internal Flow Analysis of Semi-Freejet Type High Altitude Environment Simulation Test Facility for the High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 상온시험 및 내부유동 해석)

  • Lee, Seongmin;Yu, Isang;Choi, Jiseon;Oh, Junghwa;Shin, Minkyu;Ko, Youngsung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.290-296
    • /
    • 2018
  • In this study, the cold test and the numerical analysis were carried out according to the shape parameters of the test model in order to confirm the operation range of high altitude environment simulation test facility for the supersonic vehicle. The blockage ratio, angle and length ratio were considered as the design parameters. The blockage rate is expected to be limited in the region of more than 40% due to the normal shock and expansion fan. It was confirmed that the angle of model should be selected at the size of 45 degrees or less due to the influence of the strong shock wave. There was no difference in performance between the lengths of 8 times the model diameter. Finally, we obtained the performance database according to the shape parameters of the conical test model and confirmed the operable range of the semi-freejet type high altitude environment simulation test facility.

Design and Cold Test of Semi-Freejet High Altitude Environment Simulation Test Facility for High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 설계 및 상온실험)

  • Lee, Seongmin;Yu, Isang;Park, Jinsu;Ko, Youngsung;Kim, Sunjin;Lee, Jungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.2
    • /
    • pp.115-124
    • /
    • 2018
  • In this study, a cold flow test was carried out on a high-speed vehicle facility with a high-altitude environment simulator. Variable test was carried out according to the blockage ratio, angle, and length of the test model. It is confirmed that the blockage rate can be operated in the range of 40%, and that the model should be selected at an angle of 45 degrees or less. The variables of length are less dominant compared to the variables of blockage rate and angle. Through this, a database is obtained according to the parameters of the conical model of the high-speed vehicle test facility.