• 제목/요약/키워드: Sella turcica

검색결과 24건 처리시간 0.02초

Physiologic Cervical Alignment Change between Cervical Spine X-ray and Computed Tomography

  • Lee, Ho Jin;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.784-790
    • /
    • 2021
  • Objective : The purpose of this study was to investigate the correlations among various radiological parameters used to determine cervical alignment from cervical spine radiographs (X-CS) and cervical spine computed tomography (CT-CS), both within and between modalities. Methods : This study included 168 patients (≤60 years old) without a definite whole spine deformity who underwent CT-CS and X-CS. We measured occipital slope (O-s), C1 slope, C2 slope, C7 slope, sella turcica - C7 sagittal vertical axis (StC7-SVA), spino-cranial angle, T1 slope, and C27-SVA. We calculated the O-C2 angle, O-C7 angle, and C2-7 angle from the measured parameters and conducted correlation analyses among multiple parameters. Results : The intrinsic correlation features among multiple cervical parameters were very similar for both X-CS and CT-CS. The two SVA parameters (C27-SVA and StC7-SVA) were mainly influenced by the upper cervical slope parameters (r=|0.13-0.74|) rather than the lower slope cervical parameters (r=|0.08-0.13|). The correlation between X-CS and CT-CS for each radiological parameter was statistically significant (r=0.26-0.44) except for O-s (r=0.10) and StC7-SVA (r=0.11). Conclusion : The correlation patterns within X-CS and CT-CS were very similar in this study. The correlation between X-ray and CT was statistically significant for most radiological parameters, and the correlation score increased when the horizontal gaze was consistently maintained. The lower cervical parameters were not statistically associated with translation-related parameters (C2-7 SVA and StC7-SVA). Therefore, the upper cervical segment may be a better predictor for determining head and neck translation.

두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향 (Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography)

  • 김은혜;주영철;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

뇌하수체선종의 방사선치료후 혈중 호르몬치의 변화 (Radiation Therapy for Pituitary Adenoma -Changes in Endocrine Function after Treatment-)

  • 윤세철;장홍석;김성환;신경섭;박용휘;손호영;강준기
    • Radiation Oncology Journal
    • /
    • 제9권2호
    • /
    • pp.185-195
    • /
    • 1991
  • 가톨릭의대 강남성모병원 방사선치료실에서는 1983년 3월부터 1990년 4월 사이 7년여 동안에 뇌하수체선종으로 확진되었던 74명의 환자($7\~65$세, 평균 37세, 남:여=39:35)에 대하여 뇌하수체부위에 외부방사선치료를 하였다. 방사선치료는 6 MV 선형 가속기를 사용하여 선원중심축거리 80 cm, $4{\times}4{\times}4\~8{\times}8{\times}8cm^3$ 조사야로 3문조사하였다(180cGy/일, 5회/주, $20\~65$Gy). 5예에서는 정위다방향고선량단일조사($15\~25$ Gy/l회)를 실시하였다. 이 환자들의 수술전후 및 방사선치료 후에 복합뇌하수체자극검사를 실시하여 종양의 호르몬분비에 따른 분류와 방사선치료가 호르몬분비에 미치는 영향을 추적조사하였다. 호르몬분비에 따른 뇌하수체선종의 분류는 프로랙틴종 23예($29\%$), 성장호르몬분비종 20예($26\%$), 부신피질자극호르몬분비종 6예 ($8\%$) (쿠싱병 4예와 넬슨증후군 2예)였으며 4예 ($5\%$)에서는 프로랙틴과 성장호르몬을 동시에 분비하였다. 한편, 호르몬분비기능없는 종양이 29예($37\%$)였다. 23예의 프로랙틴종 중 15예 ($65\%$)와 20예의 성장호르몬분비종 중 3예 ($15\%$)에서는 방사선치료$2\~3$년 후 정상 호르몬 수치로 전환되었다. 부신피질자극호르몬분비종은 6예 중 1예를 제외한 전예에서 치료 후 모두 정상이되었다. 방사선치료에 따른 부작용으로서 범하수체기능저하증 및 갑상선기능저하증이 각각 7예($9\%$)씩 그리고 성선기능저하증 2예 ($3\%$) 등이 관찰되었다. 전예 중 15예 ($20\%$)에서는 정기적인 호르몬 추적검사를 실시하지 못하였다.

  • PDF

디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰 (A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography)

  • 정연진;주영철;홍동희;김상현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.897-904
    • /
    • 2022
  • 본 연구의 목적은 디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준(DRL)에서 제시하는 검사 조건과 현재 임상에서 적용하고 있는 검사 조건 적용 시 선량과 화질의 차이 비교를 통해, 디지털 방사선환경에 적절한 두부 방사선검사의 조건에 대해 고찰하고자 한다. 본 연구는 두부모형팬텀을 대상으로 하였으며, 조사 조건은 임상에서 사용하는 조건(Clinic)과 DRL값(DRL75), DRL 평균값(DRLmean)으로 구분하여 실험하였다. 선량은 입사표면선량(ESD)을 측정하였고, 화질은 신호 대 잡음비와 대조도 대 잡음비를 측정하여 비교 분석하였다. 검사 조건 변화에 따른 skull AP ESD의 평균값은 Clinic 1214.03±4.21 µGy, DRL75 301 7.83±8.14 µGy, DRLmean 2283.50±7.09 µGy이었으며, skull Lat. ESD의 평균값은 Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, DRLmean 1654.43±6.48 µGy로 통계적으로 유의한 것으로 나타났다(p<0.01). 안와, 상악동, 전두동, 터키안장에서 측정한 SNR과 CNR의 평균값은 통계적으로 유의하였다(p<0.01). 본 연구 결과 임상에서 사용하는 조건이 DRL에 비해 AP는 약 58%, Lat.은 약 70% 정도의 낮은 선량 수치를 나타내었으며, 화질 측면에서 정성적인 차이가 없었다. 본 연구를 통해 디지털 방사선 환경에 적합한 새로운 진단참고수준에 대해 고려해 볼 필요가 있으며, 그에 따른 선량의 저감화가 이루어져야 할 것으로 사료된다.