• 제목/요약/키워드: Self-sustainable operation

검색결과 34건 처리시간 0.024초

1kW급 고체산화물 연료전지 발전시스템 자열운전 (Self-sustainable Operation of a 1kW class SOFC System)

  • 이태희;최진혁;박태성;유영성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF

1kW 고체산화물 연료전지(SOFC) 시스템 설계 및 자열운전 (Design and Self-sustainable Operation of 1 kW SOFC System)

  • 이태희;최진혁;박태성;유영성;남석우
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.384-389
    • /
    • 2009
  • KEPRI (Korea Electric Power Research Institute) has studied planar type solid oxide fuel cell (SOFC) stacks using anode-supported cells and kW class co-generation systems for residential power generation. In this work, a 1 kW SOFC system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a SOFC stack made up of 48 cells, a fuel reformer, a catalytic combustor, and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation in that system. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. When the 1 kW SOFC stack was tested using hydrogen at $750^{\circ}C$, the stack power was about $1.2\;kW_e$ at 30 A and $1.6\;kW_e$ at 50 A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_e$ with hydrogen and $1.2\;kW_e$ with city gas respectively. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water.

Synthesis of four-bar linkage motion generation using optimization algorithms

  • Phukaokaew, Wisanu;Sleesongsom, Suwin;Panagant, Natee;Bureerat, Sujin
    • Advances in Computational Design
    • /
    • 제4권3호
    • /
    • pp.197-210
    • /
    • 2019
  • Motion generation of a four-bar linkage is a type of mechanism synthesis that has a wide range of applications such as a pick-and-place operation in manufacturing. In this research, the use of meta-heuristics for motion generation of a four-bar linkage is demonstrated. Three problems of motion generation were posed as a constrained optimization probably using the weighted sum technique to handle two types of tracking errors. A simple penalty function technique was used to deal with design constraints while three meta-heuristics including differential evolution (DE), self-adaptive differential evolution (JADE) and teaching learning based optimization (TLBO) were employed to solve the problems. Comparative results and the effect of the constraint handling technique are illustrated and discussed.

u-City 운영비 절감방안에 관한 연구 (A Study on a Strategy for Reducing Operating Costs of u-City)

  • 박광호;김윤형
    • 산업경영시스템학회지
    • /
    • 제33권1호
    • /
    • pp.24-32
    • /
    • 2010
  • The first full-scale u-City operation has started in Dongtan u-City. As local cities take over and operates the u-City, unexpected issues arise such as securing the budget of operating costs and self-providing the costs with business models utilizing the u-City assets. The paper presents a strategy for solving these issues. The strategy provides a foundation(infrastructure) for long-term operation models which may reduce the long-term operation costs. In order to establish the economic operating framework of u-City, suggested are some cost-reduction models based on the operating costs structure. For each model, a base framework with comparative analysis of operating costs is provided. With these models, each u-City may select a relevant model according to the characteristics of it. We hope that the framework provides the foundation for efficient and sustainable u-City operations.

SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험 (Development and Performance Test of SOFC Co-generation System for RPG)

  • 이태희;최진혁;박태성;최호윤;유영성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

Development of kW Class SOFC Systems for Combined Heat and Power Units at KEPRI

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Keun-Bae;Yoo, Young-Sung
    • 한국세라믹학회지
    • /
    • 제45권12호
    • /
    • pp.772-776
    • /
    • 2008
  • The Korea Electric Power Research Institute (KEPRI) has been developing planar solid oxide fuel cells (SOFCs) and power systems for combined heat and power (CHP) units. The R&D work includes solid oxide fuel cell (SOFC) materials investigation, design and fabrication of single cells and stacks, and kW class SOFC CHP system development. Anode supported cells composed of Ni-YSZ/FL/YSZ/LSCF were enlarged up to $15{\times}15\;cm^2$ and stacks were manufactured using $10{\times}10\;cm^2$ cells and metallic interconnects such as ferritic stainless steel. The first-generation system had a 37-cell stack and an autothermal reformer for use with city gas. The system showed maximum stack power of about $1.3\;kW_{e,DC}$ and was able to recover heat of $0.57{\sim}1.2\;kW_{th}$ depending on loaded current by making hot water. The second-generation system was composed of an improved 48-cell stack and a prereformer (or steam reformer). The thermal management subsystem design including heat exchangers and insulators was also improved. The second-generation system was successfully operated without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_{e,DC}$ with hydrogen and $1.2\;kW_{e,DC}$ with city. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water. Recently KEPRI manufactured a 2kW class SOFC stack and a system by scaling up the second-generation 1kW system and will develop a 5kW class CHP system by 2010.

고출력 지속이 가능한 인체 구동 방식의 자가 발전기 개발 (Human-Powered Generator designed for Sustainable Driving)

  • 임윤호;양윤석
    • 전자공학회논문지
    • /
    • 제52권7호
    • /
    • pp.135-142
    • /
    • 2015
  • 인체 구동 방식의 자가 발전기는 외부 환경에 덜 의존한다는 장점 덕분에 비상용 혹은 야외 활동 중의 소규모 전력 공급원으로 주목 받고 있다. 하지만 대부분의 자가 발전기는 전자기 유도 결합의 효율이 높지 않아 출력이 미미하며, 특정 부위의 근육만을 지속적으로 사용하는 단조로운 구동 방식을 택하고 있어, 사용 중에 쉽게 지루해질 뿐만 아니라 근피로가 쉽게 누적되어 실제 원하는 출력을 얻을 만큼 충분한 시간 동안 구동하는 것이 거의 불가능하다. 이러한 낮은 효율과 사용성의 문제로 인해 인체 구동 방식의 자가발전기가 실생활에서 사용되는 빈도는 높지 않다. 본 연구에서는 전자기 유도 효율이 높은 종축 결합 방식의 발전 장치를 간단한 구조로 구현하여 출력을 높이는 동시에, 자성체의 운동 관성에 의한 가속이 가능한 인체 구동 방식의 발전기를 설계 제작하였다. 개발된 발전기와 기존 상용 자가 발전기와의 비교 실험을 통해 높은 출력 뿐 아니라 장시간 구동이 가능함을 검증하였다. 아울러 인체 구동 발전기에서 실질적으로 중요한 요소임에도 불구하고 기존 연구에서 제시된 바 없는 인체의 투입 에너지를 실증적으로 파악하기 위해 호흡 가스 기반의 실제 운동 대사량 측정법에 근거한 실험을 시행하여 자가 발전기의 운동 부하를 추정하였다. 향후 성능 개선과 휴대성 증진을 통해 모바일 기기의 전력 지속 문제를 해결하는 데 기여할 수 있을 것으로 기대한다.

지속가능경영체제를 지원하는 내부감사의 효과적 운영에 관한 연구 (A study on the operation of effective internal audit for business continuity management system)

  • 신동식;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.373-385
    • /
    • 2009
  • In business aspects, the corporate usually confronted with various risks. such as the management problems of the quality, the environment, the safety & health, the ethics, and the social responsibility. Overall monitoring of these aspects is required to the top manager ceaselessly. In the past ways, for these problems, the government has been controlled the corporate to keep them. But nowadays, the needs of self management of these topics is rising up for the business continuity especially to the multi-national corporate. To prove their soundness they issued the management status report periodically. Internal audit will works not only the self confirming tool but also the best supporting tool for the policy managements in such circumstances. So, an effective internal audit will lead the business continuity management to the future.

  • PDF

운영비 절감을 고려한 u-City 구축 모델 개발 (A Development of u-City Construction Model Considering the Reducing of Operating Cost)

  • 박광호;김대영;김윤형
    • 산업경영시스템학회지
    • /
    • 제33권4호
    • /
    • pp.10-22
    • /
    • 2010
  • The first full-scale u-City operation has started in Dongtan u-City. As local cities take over and operate the u-City, unexpected issues arise such as securing the budget of operating costs and self-providing the costs with business models utilizing the u-City assets. The paper presents a strategy for solving these issues. The strategy provides a foundation(infrastructure) for long-term operation models which may reduce the long-term operating costs. In order to establish the economic operating framework of u-City, suggested are some cost-reduction models based on the operating costs structure. For each model, a base framework with comparative analysis of operating costs is provided. With these models, each u-City may select a relevant model according to the characteristics of it. We hope that the framework provides the foundation for efficient and sustainable u-City operations.

지속 가능한 마을만들기를 위한 추진체계 개선방안 - 김해시를 중심으로 - (Improvement Plan for Promotion System of Sustainable Rural Community Building)

  • 최영완;엄민호;김영주
    • 농촌계획
    • /
    • 제28권4호
    • /
    • pp.55-67
    • /
    • 2022
  • In this study, the village development promotion system was reorganized for Gimhae-si, and improvement plans and post-operation management plans were prepared through expert surveys. Through the Village Development Project, the landscape and environment of the village were improved, and the village and residents were positively changed. The Village Development Project laid the foundation for regional revitalization, giving the next generation hope for the sustainable development of the village. While maintaining the framework of the existing Rural Development Projects guidelines through case analysis of other regions, we operate educational programs for each stage by reflecting regional characteristics, and utilize and communicate with intermediate support organizations, systematically operate, and actively intervene by Eup·Myeon administration. In addition, as a follow-up management program, various follow-up management programs were being operated, such as support for capacity building such as consulting, as well as facility maintenance and support for village managers. As a result of the expert survey to review the adequacy of the improvement plan, the improvement plan derived from the overall average of 4.28 points and the standard deviation of 0 to 0.94 points for the process is judged to be appropriate. In particular, the item of 'self-reliance stage follow-up management' was very important as all experts responded with 5 points. By establishing the village development performance goals, we tried to check whether the qualitative/quantitative goals were achieved by year, and to secure quantified status data in response to changes such as resetting performance goals or adding new performance indicators. In this study, in order to improve the capacity to achieve regional development in response to the rural agreement, we prepared our own sustainable village development promotion system, governance establishment, and follow-up management plan. In addition, it is expected to be used as a reference material for the selection of new districts and the follow-up management of completed districts by establishing the village development goals.