• 제목/요약/키워드: Self-noise

검색결과 578건 처리시간 0.027초

디스플레이 시스템을 위한 소면적 12-bit 300MSPS CMOS D/A 변환기의 설계 (Design of a Small Area 12-bit 300MSPS CMOS D/A Converter for Display Systems)

  • 신승철;문준호;송민규
    • 대한전자공학회논문지SD
    • /
    • 제46권4호
    • /
    • pp.1-9
    • /
    • 2009
  • 본 논문에서는 디스플레이 시스템을 위한 소면적 12-bit 300MSPS의 D/A 변화기(DAC)를 제안한다. 최근 SoC(System-On-Chip) 경향에 맞는 소면적 DAC를 구현하기 위한 전체적인 구조는 6-MSB(Most Significant Bit) + 6-LSB(Least Significant Bit)의 full matrix 구조로 설계 하였다. 고해상도 동작에 요구되는 output impedance을 만족하는 monitoring bias 구조, 고속 동작 및 소면적 디지털 회로 구성을 위하여 logic과 latch 및 deglitching 역할을 동시에 할 수 있는 self-clocked switching logic을 각각 제안하였다. 설계된 DAC는 Samsung $0.13{\mu}m$ thick gate 1-poly 6-metal N-well CMOS 공정으로 제작되었다. 제작된 DAC의 측정결과 INL (Integrated Non Linearity) / DNL (Differential Non Linearity)은 ${\pm}3LSB$ / ${\pm}1LSB$ 이하로 나타났으며, 300MHz 샘플링 속도와 15MHz의 출력신호에서 SFDR은 약 70dB로 측정되었다. DAC의 유효면적은 $0.26mm^2$ ($510{\mu}m{\times}510{\mu}m$)로 기존의 DAC에 비하여 최대 40% 감소된 초소면적으로 구현되었으며, 최대 전력 소모는 100mW로 측정되었다.

2차 고조파 주입을 사용한 고 선형성의 자체 발진 혼합기 (A Highly Linear Self Oscillating Mixer Using Second Harmonic Injection)

  • 김민회;조춘식;이재욱
    • 한국전자파학회논문지
    • /
    • 제23권6호
    • /
    • pp.682-690
    • /
    • 2012
  • 본 논문은 2차 고조파 주입을 적용한 고선형의 균형적인 자체 발진 혼합기(SOM)를 제안하였다. 제안한 SOM은 발진을 위하여 균형적 공진기 구조인 H-슬롯 결함 접지면 구조로 설계하였다. H-슬롯 결함 접지면 구조는 높은 Q 계수를 가지므로 발진기의 낮은 위상 잡음을 제공하기에 적합한 구조이다. 혼합기는 균형적 국부발진기(LO) 신호가 RF 입력 포트에 영향을 주면 안 되므로 LO-RF 신호의 격리에 좋은 단일 평형 혼합기를 활용하였다. 또한, 제안한 SOM은 선형성 향상을 위해 IF의 2차 고조파 주입을 위하여 서로 다른 피드백 경로를 사용하는 두 가지 방법을 제안하였다. 첫 번째 방법은 입력 파워 -20 dBm의 5 GHz RF 입력 신호일 때 226 MHz IF에서 3.08 dB의 변환 이득을 실현하였고, 두 번째 방법으로는 입력 파워 -20 dBm의 5.2 GHz RF 입력 신호일 때 423 MHz IF에서 2 dB의 변환 이득을 달성하였다. 두 가지 방법 대한 측정 결과, 3차 혼변조 왜곡(IMD3)는 각각 61.8 dB, 65 dB로 나타났다. 따라서 제안한 SOM은 2차 고조파 주입 기술을 적용하지 않은 것에 비해 두 가지 방법 각각 IMD3가 18.8 dB, 21 dB로 개선되었으므로 향상된 선형성을 보여준다.

진동형 각속도 검출 센서를 위한 애널로그 신호처리 ASIC의 구현 (Implementation of Analog Signal Processing ASIC for Vibratory Angular Velocity Detection Sensor)

  • 김청월;이병렬;이상우;최준혁
    • 대한전자공학회논문지SD
    • /
    • 제40권4호
    • /
    • pp.65-73
    • /
    • 2003
  • 본 논문은 진동형 각속도 검출 센서로부터 각속도 신호를 검출하는 애널로그 신호처리 ASIC의 구현에 관한 것이다. 각속도 검출 센서의 출력은 구조적으로 콘덴서의 용량변화로 나타나므로 이를 검출하기 위하여 전하 증폭기를 이용하였으며, 센서의 구동에 필요한 자체발진회로는 각속도 검출 센서의 공진 특성을 이용한 정현파 발진회로로 구현하였다. 특히 센서의 제조 공정으로 인한 특성 변화나 온도 변화와 같은 외부 요인에 의한 자체발진특성의 열화를 방지하기 위하여 자동이득조절회로를 사용하였다. 진동형 각속도 검출 센서의 동작특성에 의하여 진폭변조 형태로 나타나는 각속도 신호를 검출하기 위하여 동기검파회로를 사용하였다. 동기검파회로에서는 반송파의 크기에 따라 검파신호의 크기가 달라지는 현상을 방지하기 위하여 스위칭 방식의 곱셈회로를 사용하였다. 설계된 칩은 0.5㎛ CMOS 공정으로 구현하였으며, 1.2㎜×1㎜의 칩 크기로 제작되었다. 실험 결과 3V의 전원전압에서 3.6mA의 전류를 소비하였으며, 칩과 각속도 센서를 결합한 정상동작상태에서 직류에서 50㎐까지 잡음 스펙트럼 밀도는 -95 dBrms/√㎐에서 -100 dBrms/√㎐ 사이에 존재하였다.

시그모이드 추정과 임계 판정 가중 오차를 사용한 새로운 SDD 등화의 자기적응 성능 개선 (Self-Adaptive Performance Improvement of Novel SDD Equalization Using Sigmoid Estimate and Threshold Decision-Weighted Error)

  • 오길남
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.17-22
    • /
    • 2016
  • 고차 QAM 시스템에 대한 자기적응 등화에서 눈 모형이 완전히 닫힌 등화 초기에 적용하여 눈 모형을 빠르게 열뿐만 아니라 정상상태 오차 레벨을 크게 낮추는 새로운 SDD 알고리즘을 제안한다. 제안 방법은 M-QAM 응용에서, 관찰에 가장 인접한 두 심볼을 추정의 기반으로 함으로써 기존 SDD의 계산 복잡성을 최소화하고, QAM 차수에 무관하게 연판정을 크게 단순화하였다. 아울러 심볼 추정에 임계 함수에 비해 오판정 회피가 우수한 시그모이드 함수를 적용, 추정의 신뢰도를 높였다. 또한 등화기 갱신을 위한 오차 발생 시 임계 함수에 의한 심볼 판정 값을 오차에 가중하여 오차 변동 범위를 확장함으로써 제안한 자기적응 등화기의 초기화 성능을 개선하였다. 결과적으로 제안 방법은 기존 SDD의 계산 복잡성과 초기화 및 수렴 특성을 현저히 개선하였다. 부가 잡음이 존재하는 다중경로 채널 조건에서 64-QAM 및 256-QAM에 대한 모의실험을 통해 CMA와 제안한 2-SDD 및 가중된 2-SDD의 두 가지 형태의 성능을 비교하고 제안 방법의 유용성을 확인하였다.

자기 유사성을 이용한 가우시안 노이즈 제거 알고리즘 (Gaussian Noise Reduction Algorithm using Self-similarity)

  • 전영은;엄민영;최윤식
    • 대한전자공학회논문지SP
    • /
    • 제44권5호
    • /
    • pp.1-10
    • /
    • 2007
  • 대부분의 자연 영상은 프랙탈 이론의 기반이 되는 자기 유사성이라는 특징을 가지고 있다. 비록 국부적으로 영상을 정상 신호라고 가정할 수 있지만 일반적으로 영상 신호는 에지나 코너 부분과 같은 불연속성을 가지고 있는 비정상 신호이다. 이 때문에 대부분의 선형 알고리즘의 성능 저하가 나타난다. 따라서 이러한 문제를 해결하기 위하여 본 논문에서는 영상 내에 포함되어 있는 자기 유사성을 이용하는 새로운 비선영 잡음 제거 알고리즘을 제안 한다. 이를 위해 우선 잡음 제거를 수행 할 위치의 화소 주변 화소들을 이용하여 평탄 영역인지를 판단한다. 평탄 영역일 경우 그 주변 픽셀들의 평균으로 잡음을 제거하고, 평탄 영역이 아닌 경우, 블록 MSE(block Mean Square Error) 관점에서 유사도가 높은 블록을 탐색하여 그 블록들의 중심 화소값들을 이용하여 잡음 제거를 수행한다. 실험 결과는 PSNR 측면에서 잡음 제거 성능이 약 $1{\sim}3dB$ 정도 향상됨을 보여준다. 또한 추정 이론 관점에서 추정자의 분산 분석 결과 가장 낮은 분산을 갖음을 보였다.

사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구 (An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation)

  • 정미화
    • 한국직업건강간호학회지
    • /
    • 제3권호
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • 군사기지 인근주민의 군용기 비행금지 청구의 허용 여부 - 최고재(最高裁) 2016. 12. 8. 선고 평성(平成) 27년(행(行ヒ)) 제512, 513호 판결 - (Permission of the Claim that Prohibits Military Aircraft Operation Nearby Residential Area - Supreme Court of Japan, Judgement Heisei 27th (Gyo hi) 512, 513, decided on Dec. 8, 2016 -)

    • 권창영
      • 항공우주정책ㆍ법학회지
      • /
      • 제33권1호
      • /
      • pp.45-79
      • /
      • 2018
    • 항공기나 군용기의 운용이 폭발적으로 증가함에 따라, 공항이나 비행장 인근 주민들이 항공기 운항으로 인한 소음 진동 등을 이유로 손해배상을 청구하거나 비행을 금지하는 경우가 점차 늘어나고 있다. 최근에는 원고는 토지의 소유권에 터 잡아 피고를 상대로 토지의 상공을 헬기의 이 착륙 항로로 사용하는 행위의 금지를 구하는 소를 제기하였고, 대전고등법원에서 청구를 인용한 사례가 있다. 비록 위 판결은 대법원에서 파기되었지만, 비행금지청구에 관한 논의가 필요하다. 일본에서는 공항소음소송이 환경단체를 중심으로 오래 전부터 제기되어 왔는데, 소음피해로 인한 손해배상을 인정하는 경우와 달리 비행금지청구를 인용한 판결은 2014. 5. 21. 요코하마 지방재판소에서 처음 선고되었다. 위 판결은 항소심에서 일부 변경되어 원고의 청구가 일부 인용되었으나. 최고재판소에서 파기 환송되었다. 아쓰기(厚木) 기지는 미국과 일본이 공동으로 사용하는 기지인데, 인근주민들은 아쓰기 기지에 이착륙하는 항공기에서 발생하는 소음에 의해 신체적 피해 및 수면방해, 생활방해 등의 정신적 피해를 받고 있다고 주장하면서, 방위청장관이 소속되어 있는 국가에 대하여 자위대기 및 미군기의 운항금지 등을 요구하는 행정소송을 요코하마 지방재판소에 제기하였다. 제1심은 "부득이하다고 인정하는 경우를 제외하고"라는 제한을 부과하여 매일 오후 10시부터 다음날 오전 6시까지 자위대기의 비행을 금지하는 판결을 선고하였고, 위와 같은 결론은 항소심에서도 유지되었다. 그러나 최고재판소는 자위대기의 비행금지청구를 인용한 원심판결을 파기하고, 그 부분에 해당하는 제1심 판결을 취소하였으며, 원고들의 청구를 기각하였다. 최고재판소는 자위대기의 운항은 고도의 공공성이 인정되고, 소음피해는 경시할 수 없으나 상응하는 대책을 강구할 수 있으므로, 방위청장관의 권한행사는 타당하다고 판시하였다. 우리나라에서도 군용기지 인근주민들이 미국이나 대한민국 또는 국방부장관을 상대로 군용기 비행금지를 구하는 소를 제기할 수 있다. 만약 군용기지 부근의 주민들이 미국정부를 상대로 미군기 비행금지를 청구하는 소를 제기하면, 법원은 재판권면제를 이유로 소장각하명령을 하여야 한다. 현행 판례 법리에 따르면, 국방부장관을 상대로 군용기의 비행금지를 청구하는 의무이행소송이나 무명항고소송은 허용되지 아니하므로, 그러한 소는 부적법하다. 다만, 행정소송법이 개정되어 의무이행소송이 도입된다면 소제기는 적법하게 될 수 있다. 군용기 운항에 관한 행정처분이 위법하다고 판단하기 위해서는 청구가 허용될 경우 인근주민이 받을 이익과 상대방 및 제3자가 받게 될 불이익 등을 비교 형량해 보아야 한다. 국방부장관으로서는 군용기의 운항으로 인한 이익(초계임무나 대잠활동 등 국방상 필요, 항공정보의 획득 제공, 재해파견 등 민생협력 활동, 해적대처 등 국제공헌, 교육 훈련 등)이 인근주민이 군용기 비행금지로 인하여 얻는 이익보다 훨씬 크다는 점을 주장 증명할 필요가 있다.

    소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용 (Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss)

    • 이미영;서석권;이충원
      • Journal of Preventive Medicine and Public Health
      • /
      • 제29권3호
      • /
      • pp.539-553
      • /
      • 1996
    • 이 연구는 1994년도 5월부터 9월까지 동산병원 건강 관리과에서 소음특수건강진단을 받은 근로자 중 일부를 대상으로 하여 1차 선별 순음청력검사에 난청선별 설문지(HHIE-S)의 적용가능성을 점검해 보기 위하여 시행되었다. 대상자는 이 기간중의 특수검진 수진자들로서 총 6,700명 중 계통적 표본추출법에 의하여 매 5번째의 근로자가 추출되었다. 최종분석 대상은 자료가 미비한 14명을 제외한 1,019명으로 남자 488명, 여자 531명이었다. 소음성 난청의 1차 선별검사로 순음청력검사와 HHIE-S를 포함한 설문지검사를 실시하였다. 청력검사의 1차 선별기준은 양쪽 어느 귀의 청력손실이 4000Hz 에서 40dB이상인 자로 하였고 2차 정밀검사에서 난청의 기준은 3분법으로 계산하여 30dB 이상이면서 4000Hz에서 50dB 이상의 청력손실이 있는 자로 하였다. 설문지의 신뢰도는 0.84였다. 청력장애와 관련된 변수들의 단일변량분석에서 유의한 차이를 보인 항목은 남자에서 HHIE-S 총척도와 사회적/상황적 소척도에서 근무기간, 군복무력, 1000Hz 및 4000Hz에서의 청력역치였으며 여자에서 총척도와 소척도 모두에서 연령, 근무기간, 1000Hz 및 4000Hz에서의 청력역치였다. 다단계 다중회귀분적에서 남자에서 1000Hz및 4000Hz에서의 청력역치가 선택되었으며 여자에서는 총척도와 사회적/상황적 소척도에서 1000Hz 및 4000Hz에서의 청력 역치, 근무기간, 연령이 선택되었다. 2차 순음청력검사를 황금기준으로 하여 1차 선별청력검사와 HHIE-S점수를 기준으로 한 ROC곡선을 그린 결과, 최적의 타당도는 병행검사에서 HHIE-S점수 8을 기준으로 하였을 때였으며 민감도와 특이도가 각각 85%와 67%이었으며 위음성이 15%로 최소였다. 이러한 결과는 HHIE-S가 우리나라에서 신뢰도 및 타당도가 비교적 적절하며 소음성 난청 1차 선별검사에 순음청력검사와 함께 병행해서 사용하면 민감도를 높이고 위음성을 떨어뜨림으로써 순음청력검사의 병행검사로 적용가능성이 있음을 시사해 준다.

    • PDF

    MMIC 모듈을 이용한 V-band 무선 송수신 시스템의 구축 (Development of V-band Wireless Transceiver using MMIC Modules)

    • 이상진;안단;이문교;고두현;진진만;김성찬;김삼동;박현창;박형무;이진구
      • 대한전자공학회:학술대회논문집
      • /
      • 대한전자공학회 2005년도 추계종합학술대회
      • /
      • pp.575-578
      • /
      • 2005
    • We report on a low-cost V-band wireless transceiver with no use of any local oscillator in the receiver block using a self-heterodyne architecture. V-band Microwave monolithic IC (MMIC) modules were developed to demonstrate the wireless transceiver using coplanar waveguide (CPW) and GaAs PHEMT technologies. The MMIC modules such as the MMIC low noise amplifier (LNA), medium power amplifier (MPA) and the up/down-mixer were installed in the transceiver system. To interface the MMIC chips with the component modules for the transceiver system, CPW-to-waveguide fin-line transition modules of WR-15 type were designed and fabricated. The fabricated LNA modules showed a $S_{21}$ gain of 8.4 dB and a noise figure of 5.6 dB at 58 GHz. The MPA modules exhibited a gain of 6.9 dB and a $P_1$ $_{dB}$ of 5.4 dBm at 58 GHz. The conversion losses of the up-mixer and the down-mixer module were 14.3 dB at a LO power of 15 dBm, and 19.7 dB at a LO power of 0 dBm, respectively. From the measurement of V-band wireless transceiver, a conversion gain of 0.2 dB and a P $_{1dB}$ of 5.2 dBm were obtained in the transmitter block. The receiver block showed a conversion gain of 2.1 dB and a P $_{1dB}$ of -18.6 dBm. The wireless transceiver system demonstrated a successful data transfer within a distance of 5 meters.

    • PDF

    자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향 (Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System)

    • 정민규;성열훈
      • 한국방사선학회논문지
      • /
      • 제14권5호
      • /
      • pp.635-642
      • /
      • 2020
    • 본 연구에서는 자동노출제어장치(automatic exposure control, AEC)의 채광창 차폐정도와 농도, 감도가 관전류량과 영상품질에 미치는 영향을 분석하였다. 실험에 사용된 장비는 X선관과 간접방식의 디지털검출기가 일체형인 디지털방사선발생장치(Digital Diagnost, Philips, Netherlands)를 사용하였다. 채광창 차폐정도는 3 mm 두께의 납을 이용하여 0%부터 100%까지 12.5%씩 순차적으로 누적 차폐하여 9단계로 구분하였다. 농도는 제조사에서 제시한 3단계(+2.5, 0, -2.5)와 감도 3단계(S200, S400, S800)를 대상으로 하였다. 관전류량 평가는 관전압을 40 kVp로 고정하고 AEC 조절인자들이 교차한 81가지의 조합조건에서 자동 노출된 관전류량을 측정하였다. 영상품질평가는 자체 제작한 원뿔형 피라미드 팬텀의 방사선영상을 육안 평가하여 유효한 영상을 선발하였고 이들의 신호 대 잡음비(signal to noise ratio, SNR)을 측정하였다. 그 결과 관전류량은 채광창 차폐정도가 100%, 감도 S200, 농도 2.5일 때 60.0 mAs로 가장 많이 조사되었으며, 채광창 차폐정도가 0%, 감도 S800, 농도 -2.5일 때 0.9 mAs로 가장 적게 조사되었다. SNR은 채광창 차폐정도가 0%, 감도 S200, 농도 2.5일 때 25.2로 가장 우수하였고, 채광창 차폐정도가 25%, 감도 S800, 농도 -2.5일 때 SNR이 4.7로 가장 낮았다.