• Title/Summary/Keyword: Self expandable metallic stents

Search Result 16, Processing Time 0.027 seconds

Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction

  • Yang, Min Jae;Kim, Jin Hong;Hwang, Jae Chul;Yoo, Byung Moo;Lee, Sang Hyub;Ryu, Ji Kon;Kim, Yong-Tae;Woo, Sang Myung;Lee, Woo Jin;Jeong, Seok;Lee, Don Haeng
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.722-727
    • /
    • 2018
  • Background/Aims: Although endoscopic bilateral stent-instent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Methods: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Results: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Conclusions: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo;Lee, Seung Hyun;Myung, Dae Seong;Lee, Wan Sik;Joo, Young Eun;Jung, Mi Ran;Ryu, Seong Yeob;Park, Young Kyu;Cho, Sung Bum
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

Endovascular Stent Placement in a Patient with a Posttraumatic Isolated Superior Mesenteric Artery Dissection with Focally Progressing Dissecting Aneurysms and a Severely Compressed True Lumen (외상 후 단독 상장간막동맥박리 후에 국소적으로 진행된 박리성 동맥류와 심한 진강의 압박이 있는 환자에서 혈관내 스텐트설치술 1례)

  • Kim, Young-Kyu;Her, Kyu Hee;Kim, Seung Hyoung;Kim, Kwangsik
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.266-271
    • /
    • 2015
  • Reports on a posttraumatic isolated superior mesenteric artery (SMA) dissection are rare. Recently, endovascular stent placement via percutaneous access, instead of vascular surgery, has been widely accepted as the initial treatment for a patient with an isolated SMA dissection or its complications. A 60-year-old female patient was transferred to our hospital due to an isolated SMA dissection after a car accident. The SMA dissection was 8.5 cm in length, and it involved the true lumen, which was severely compressed by the thrombosed false lumen. The patient was closely observed because she did not complain of any specific visceral pain. On the seventh hospital day, she underwent computed tomography (CT) to decide on a further treatment plan, irrespective of the presence of the abdominal symptom. The findings of the follow-up CT showed no difference compared to those of the previous CT. She was discharged with anti-coagulants. One month later, the follow-up CT revealed focally progressing dissecting aneurysms in the false lumen of the dissected SMA and a more severely compressed true lumen. Two self-expandable metallic stents were successfully placed in the true lumen of the dissected SMA, covering two aneurysmal lesions. Herein, we report a successful endovascular treatment with stent placement for treating focally progressing dissecting aneurysms and a severely compressed true lumen in a patient with a posttraumatic isolated SMA dissection.

  • PDF

The Role of Endoscopic Interventions in Palliative Care for the Gastrointestinal Tumors (소화기 종양에 대한 내시경적 완화치료)

  • Hye Kang Kim;Dae Young Cheung
    • Journal of Digestive Cancer Research
    • /
    • v.2 no.1
    • /
    • pp.1-4
    • /
    • 2014
  • Palliative care for cancer aims to relieve the discomfort and pain from the cancer itself and associated conditions. Gastrointestinal cancers originate from the tube like structure of gastrointestinal tract and cause complications such as obstruction, bleeding, adhesion, invasion, and perforation to adjacent organ. Recent advances in interventional endoscopy enables endoscopy physicians to do safe and effective care for gastrointestinal cancer patients. Endoscopic palliation includes stent, hemostasis, nutritional support and targeted drug delivery. Self expandable metallic stent is one of the most important modalities in gastrointestinal palliation. Through the endoscopy or over the wire pre-placed by endoscopy, stents restore the gastrointestinal luminal patency and relieve the obstructive condition. Endoscopic hemostasis is another important palliation in gastrointestinal cancer patients. Epinephrine injection, argon plasma coagulation and thermal cauterization are usual modalities for hemostasis. Histoacryl glue and fibrin glue are also available. Hemostatic nanopowder spray is newly reported effective in benign disease and is supposed to be effective also in cancer bleeding. Enteral feeding tubes including gastro- or jejunostomy and nosoduodenal tubes are placed by using endoscopic guidance. Enteral feeding tubes role as the route of easily absorbable or semi-digested nutrients and effectively maintain both patients calorie requirements and gut microenvironment. Photodynamic therapy is the one of the outstanding medical employments of photo-physics. Especially for superficial cancers in esophagus, photodynamic therapy is very useful in cancer removal and maintaining organ structure. In biliary neoplasm, photodynamic therapy is well known to be effective in cancer ablation and biliary ductal patency restoration. Targeted drug delivery is the lastest issue in palliative endoscopy. Debates and questions are still on the table. In this article, the role of endoscopic interventions in palliative care for the gastrointestinal tumors will be thoroughly reviewed.

  • PDF

Fluoroscopic Stent Placement as a Bridge to Surgery for Malignant Colorectal Obstruction: Short- and Long-Term Outcomes (악성대장협착의 근치적 절제술을 위한 수술 전 투시장치 하 스텐트 설치술: 단기 및 장기 결과)

  • Jong Hyouk Yun;Gyoo-Sik Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.615-626
    • /
    • 2023
  • Purpose To assess the outcomes of single-stage surgery following fluoroscopic stent placement for malignant colorectal obstruction. Materials and Methods This retrospective study included 46 patients (28 male and 18 female; mean age, 67.2 years) who had undergone fluoroscopic stent placement followed by laparoscopic resection (n = 31) or open surgery (n = 15) for malignant colorectal obstruction. The surgical outcomes were analyzed and compared. After a mean follow-up of 38.9 months, the recurrence-free and overall survival were estimated, and prognostic factors were evaluated. Results The mean interval between stent placement and surgery was 10.2 days. Primary anastomosis was possible in all patients. The mean postoperative length of hospitalization was 11.0 days. Bowel perforation was detected in six patients (13.0%). During the follow-up, ten patients (21.7%) developed recurrence; these included five of the six patients with bowel perforation. Bowel perforation had a significant effect on recurrence-free survival (p = 0.010). Conclusion Single-stage surgery following fluoroscopic stent placement may be effective for treating malignant colorectal obstruction. Stent-related bowel perforation is a significant predictive factor for tumor recurrence.