• Title/Summary/Keyword: Selected ion monitoring(SIM)

Search Result 109, Processing Time 0.03 seconds

Study on the Residue Analysis of Organophosphorus and Organochlorine Pesticides with Ion Trap and Quadrupole Mass Spectrometer (Ion Trap Mass Spectrometer와 Quadrupole Mass Spectrometer를 이용한 유기인제 및 유기염소제 농약 분석에 관한 연구)

  • Rhee, Jae-Seong;Park, Hyun-Mee;Er, Yon-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.902-909
    • /
    • 1995
  • Detection limit as well as calibration curves on organophosphorus pesticide(dimethoate, diazinon, parathion-methyl, fenitrothion, malathion) and BHCs were measured for evaluation of utility on qualitative or quantitative analysis of pesticides with ion Trap mass spectrometer and quadrupole mass spectrometer. As ionization source, EI and CI were adopted for qualitative analysis of pesticides by comparison of each fragmentation pattern. At the same time, the utility as trace analysis techniques through scan or selected ion monitoring(SIM) mode was evaluated. With ion trap for all pesticides, detection limit(DL, 1 ${\mu}L$ injection) on scan mode was ranged 0.008∼0.225 ng at signal to noise ratio 3. With quadrupole DL on scan mode was ranged 0.23∼3.1 ng over 0.032∼0.68 ng on SIM mode. The calibration curve with ion trap generated good linearity over 0.99 as correlation coefficient. As clean up procedure, Bio Beads S-X3 was used for the separation of oils from five organophosphorous pesticides in flour extractant showing more than 80% as recovery at most cases. In case of BHCs in jinseng with Florisil column, the recovery of pesticides has been 60% to 90%.

  • PDF

SENSITIVE DETERMINATION OF ELEVEN PHENOLIC ENDOCRINE-DISRUPTING CHEMICALS IN HUMAN URINE USING GAS CHROMATOGRAPHY/MASS SPECTROMETRY -SELECTED ION MONITORING

  • Kim, Hyub;Jang, Cheol-Hyeon
    • Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.93-100
    • /
    • 2007
  • I improved an analytical method for determining trace amounts of eleven phenolic endocrine-disrupting chemicals (11 phenolic EOCs) in human urine. The 11 phenolic EOCs were subjected to hydrolysis and then to solid phase extraction with a XAD-4 column. Alkylphenols, chlorophenols, and bisphenol A in XAD-4 column were eluted with acetonitrile, and the eluate was concentrated under a nitrogen stream, and then tert-butyldimethylsilylation. Separation and determination were done by gas chromatography, using mass spectrometry operating in the selective ion monitoring mode for quantitation. For tert-butyldimethylsily (TBDMS) derivatization the recoveries were $91.2{\sim}125.9%$, the limits of quantitation (LOQ) for the 11 phenolic EOCs in the nanogram-per-milliliter range ($0.025{\sim}1.000\;ng/mL$) were thus achieved by using 1 mL of urine, and the SIM responses were linear with the correlation coefficient varying by $0.9300{\sim}0.9943$. Based on the results for urine samples from unexposed individuals, 4-tert-octylphenol and pentachlorophenol were detected in hydrolysed urine sample. Other alkylphenols, chlorophenols and bisphenol A were not detected.

Analysis of Flavor-related Compounds from Tobacco using SPME-GC-MS (SPME-GC-MS를 이용한 담배와 관련된 향료의 분석)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.109-114
    • /
    • 2001
  • The flavor-related compounds contained in tobacco were analyzed by selected ion monitoring (SIM) method using headspace SPME gas chromatography-mass spectrometry(GC-MS). Flavor-related compounds were estragole pulegone, trans-anethole, safrole, piperonal, eugenol, methyleugenol, coumarin, trans-isoeugenol, trans-methyleugenol and myristicin. More than on of the flavor-related compounds were detected in the range $0.001-1.3{\mu}g/g$ from all brands of tobacco studied. The recovery was ranged from 89.1 to 102.9% and relative standard deviation was ranged from 2.6 to 25.2%.

  • PDF

Simultaneous determination of parabens in cosmetics by LC/MS (LC/MS를 이용한 화장품 중의 parabens 동시 분석 방법 연구)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.54-59
    • /
    • 2010
  • The simultaneous analysis of parabens in cosmetic samples was carried out by LC/MS. The cosmetic samples are directly dissolved in methanol and filterated using $0.45\;{\mu}m$ filter. The methanol-water was used for the mobile phase of gradient conditions. An Extend $C_{18}$ reverse-phase column and the selected ion monitoring (SIM) mode were applied. The analysis results of LC/MS showed good linearity with correlation coefficient of $r^2$=0.9993 in the range of 0.05 to $10\;{\mu}g$/mL and detection limit of $0.01\;{\mu}g$/mL.

Simultaneous Analysis of Pesticide Priority Pollutants in Soil (토양 중의 Pesticide Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung-Seok;Park, Young-Joo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.237-248
    • /
    • 1995
  • The simultaneous analysis of 16 organic pesticides, which are listed as a part of 129 priority pollutants by EPA(Environmental Protection Agency), was performed by GC-ECD(electron capture detector) and GC/MS-SIM(selected ion monitoring). Two extraction procedures from SW-846, sonication extraction and Soxhlet extraction, were somewhat modified and compared as an extraction and concentration method for the analysis of priority pollutants in soil. Accuracy and precision of the methods were reported from the calculation of mean recovery, mean relative standard deviation, and method detection limit.

  • PDF

Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Papers Materials

  • Kim, Hyub;Kim, Jin-Ho;Kim, Yong-Hwa
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.120.2-121
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. (omitted)

  • PDF

Dertermination of Alkylphenols, Chlorophenols and Bisphenol A in Various Samples by Freezing Filtration and GC/MS-SIM

  • Kim, Hyub
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.68.1-68.1
    • /
    • 2003
  • A method for determination 11 endocrine disrupting chemicals of phenols in various samples was deloped. The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization method and tert-butyldimethylsilyl (TBDMS) derivatization method. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at -60$^{\circ}C$ for 2 hours (freezing filtration). (omitted)

  • PDF

Research for the Analytical Method of Various Pesticides in Raw Milk by Gas Chromatography-Mass Spectrometry (GC/MSD를 사용한 원유 내 잔류농약의 분석법 연구)

  • Oh, N.S.;Shin, Y.K.;Baick, S.C.
    • Food Science of Animal Resources
    • /
    • v.29 no.4
    • /
    • pp.482-486
    • /
    • 2009
  • The aim of this study was to optimize a simple, fast, and economical analysis procedure for the determination of 16 different pesticides in raw milk via GC/MSD. Analyses were performed via gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC/MSD-SIM) using Pentachloronitrobenzene as the internal standard. The modified sample preparation methodology was based on the Pesticide Analytical Manual (PAM) of the FDA concerning fat extraction, ACN-ether partitioning, and clean-up of the Sep-Pak florisil cartridge. The modified methodology for the determination of the 16 pesticides was validated. The range of LOQs of the 16 pesticides was likely three times lower than their Maximum Residence Levels (MRLs). The recoveries of most of the pesticides were acceptable at the fortification levels of 0.5 and 1.0 ${\mu}g/mL$ and their RSD (%) level was less than 20%. None of the 16 pesticides were detected in the selected raw milk samples.

Simultaneous Analysis of Pesticide Priority Pollutants in Water Samples (수질 시료 중의 Pesticide Priority Pollutants 동시분석에 관한 연구)

  • Kim Kye-Young;Kim Chong-Hyeak;Lee Sueg-Geun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.590-598
    • /
    • 1993
  • The simultaneous analysis of samples, 16 organic pesticides in water among 129 priority pollutants listed by EPA, was performed by GC-ECD (electron capture detector) and GC/MS-SIM (selected ion monitoring). Two extraction procedures, liquid-liquid extraction (LLE) and solid-phase extraction (SPE), were studied as an extraction and concentration method. Accuracy and precision of the methods were measured by the calculation of mean recovery and mean relative standard deviation. Finally, the detection limits, the experimental limitations, and prospects were discussed.

  • PDF

Comparison of isoBOC derivatives, TBDMS derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A potential field-screening applications of GC/MS-SIM

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.235.2-236
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison: EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. (omitted)

  • PDF