Prediction of curvature ductility factor for FRP strengthened RHSC beams using ANFIS and regression models

  • Komleh, H. Ebrahimpour;Maghsoudi, A.A.
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.399-414
    • /
    • 2015
  • Nowadays, fiber reinforced polymer (FRP) composites are widely used for rehabilitation, repair and strengthening of reinforced concrete (RC) structures. Also, recent advances in concrete technology have led to the production of high strength concrete, HSC. Such concrete due to its very high compression strength is less ductile; so in seismic areas, ductility is an important factor in design of HSC members (especially FRP strengthened members) under flexure. In this study, the Adaptive Neuro-Fuzzy Inference System (ANFIS) and multiple regression analysis are used to predict the curvature ductility factor of FRP strengthened reinforced HSC (RHSC) beams. Also, the effects of concrete strength, steel reinforcement ratio and externally reinforcement (FRP) stiffness on the complete moment-curvature behavior and the curvature ductility factor of the FRP strengthened RHSC beams are evaluated using the analytical approach. Results indicate that the predictions of ANFIS and multiple regression models for the curvature ductility factor are accurate to within -0.22% and 1.87% error for practical applications respectively. Finally, the effects of height to wide ratio (h/b) of the cross section on the proposed models are investigated.

Improvement of the cyclic response of RC columns with inadequate lap splices-Experimental and analytical investigation

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.
    • Earthquakes and Structures
    • /
    • 제16권3호
    • /
    • pp.279-293
    • /
    • 2019
  • The overall seismic performance of existing pre 1960-70s reinforced concrete (RC) structures is significantly affected by the inadequate length of columns' lap-spliced reinforcement. Due to this crucial structural deficiency, the cyclic response is dominated by premature bond - slip failure, strength and stiffness degradation, poor energy dissipation capacity and low ductility. Recent earthquakes worldwide highlighted the importance of improving the load transfer mechanism between lap-spliced bars, while it was clearly demonstrated that the failure of lap splices may result in a devastating effect on structural integrity. Extensive experimental and analytical research was carried out herein, to evaluate the effectiveness and reliability of strengthening techniques applied to RC columns with lap-spliced reinforcement and also accurately predict the columns' response during an earthquake. Ten large scale cantilever column subassemblages, representative of columns found in existing pre 1970s RC structures, were constructed and strengthened by steel or RC jacketing. The enhanced specimens were imposed to earthquake-type loading and their lateral response was evaluated with respect to the hysteresis of two original and two control subassemblages. The main variables examined were the lap splice length, the steel jacket width and the amount of additional confinement offered by the jackets. Moreover, an analytical formulation proposed by Tsonos (2007a, 2019) was modified appropriately and applied to the lap splice region, to calculate shear stress developed in the concrete and predict if yielding of reinforcement is achieved. The accuracy of the analytical method was checked against experimental results from both the literature and the experimental work included herein.

An interface model for the analysis of the compressive behaviour of RC columns strengthened by steel jackets

  • Minafo, Giovanni
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.233-244
    • /
    • 2019
  • Steel jacketing technique is a retrofitting method often employed for static and seismic strengthening of existing reinforced concrete columns. When no continuity is given to angle chords as they cross the floor, the jacket is considered "indirectly loaded", which means that the load acting on the column is transferred partially to the external jacket through interface shear stresses. The evaluation of load transfer mechanism between core and jacket is not straightforward to be modeled, due to the absence of knowledge of a proper constitutive law of the concrete-to-steel interface and to the difficulties in taking into account the mechanical nonlinearities of materials. This paper presents an incremental analytical/numerical approach for evaluating the compressive response of RC columns strengthened with indirectly loaded jackets. The approach allows calculating shear stresses at the interface between core and jacket and predicting the axial capacity of retrofitted columns. A proper constitutive law is proposed for modelling the interaction between the steel and the concrete. Based on plasticity rules and the non-linear behaviour of materials, the column is divided into portions. After a detailed parametric analysis, comparisons are finally made by theoretical predictions and experimental results available in the literature, showing a good agreement.

Computational and experimental analysis of beam to column joints reinforced with CFRP plates

  • Luo, Zhenyan;Sinaei, Hamid;Ibrahim, Zainah;Shariati, Mahdi;Jumaat, Zamin;Wakil, Karzan;Pham, Binh Thai;Mohamad, Edy Tonnizam;Khorami, Majid
    • Steel and Composite Structures
    • /
    • 제30권3호
    • /
    • pp.271-280
    • /
    • 2019
  • In this paper, numerical and experimental assessments have been conducted in order to investigate the capability of using CFRP for the seismic capacity improvement and relocation of plastic hinge in reinforced concrete connections. Two scaled down exterior reinforced concrete beam to column connections have been used. These two connections from a strengthened moment frame have been tested under uniformly distributed load before and after optimization. The results of experimental tests have been used to verify the accuracy of numerical modeling using computational ABAQUS software. Application of FRP plate on the web of the beam in connections to improve its capacity is of interest in this paper. Several parametric studies were carried out for CFRP reinforced samples, with different lengths and thicknesses in order to relocate the plastic hinge away from the face of the column.

Cyclic behavior of steel beam-to-column connections with novel strengthened angle components

  • Kang, Lan;Zhang, Cheng
    • Steel and Composite Structures
    • /
    • 제42권6호
    • /
    • pp.791-804
    • /
    • 2022
  • As a type of semi-rigid connection, the top and seat angle connections are popular in current structures owing to their good cyclic performance and simple erection. However, their stiffness and load bearing capacity are relatively insufficient. This study proposes two strengthening methods to further increase the stiffness and strength of bolted-angle joints while maintaining satisfactory energy dissipation capacity (EDC) and ductility. Cyclic loading tests were conducted on six joint specimens with different strengthened angle components. Based on the test results, the influence of the following important factors on the cyclic behavior of steel joint specimens was investigated: the position of the rib stiffeners (edge rib stiffeners and middle rib stiffener), steel strength grade of rib stiffeners (Q345 and Q690), and additional stiffeners or not. In addition, the finite element models of these specimens were built and validated through a comparison of experimental and numerical results. The stiffness and bearing capacity of the bolted-angle joints could be improved significantly by utilizing the novel strengthened joints proposed in this study. Moreover, this can be achieved with almost no increase in the amount of steel required, and the EDC of this joint could also satisfy the requirements of seismic codes from various countries.

섬유시트와 매입형 CFRP Rod를 보강한 R/C 외부 보-기둥 접합부의 내진성능 평가 및 개선 (Improvement and Evaluation of Seismic Performance of Reinforced Concrete Exterior Beam-Column Joints Retrofitting with Fiber Reinforced Polymer Sheets and Embedded CFRP Rods)

  • 하기주;하영주;강현욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.151-159
    • /
    • 2015
  • 본 연구에서는 기존 철근콘크리트 구조물 보-기둥 접합부의 내진성능의 개선을 위해 보-기둥 접합부 영역을 FRP보강재 (탄소섬유시트, 아라미드섬유시트, 매입형 CFRP Rod)를 사용하여 보강한 후 내진성능을 평가하였다. 총 7개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 본 연구의 실험결과를 근거로 다음과 같은 결론을 얻었다. 기존 철근콘크리트 보-기둥 접합부의 접합부 영역을 보강한 결과, 초기 재하시 접합부 영역의 균열억제 효과와 재하 전 과정을 통하여 보강재의 구속효과로 인하여 균열억제 효과가 커서 안정적인 파괴형태 및 내력향상 효과를 나타내었다. 매입형 CFRP Rod와 탄소섬유시트를 활용한 R/C 외부 보-기둥 접합부 실험체 LBCJ-CRUS는 표준실험체 LBCJ와 비교하여 변위연성 4, 7에서 각각 최대내력은 1.54배, 에너지소산능력은 2.36배 증가하였다. 그리고 실험체 LBCJ-CS, LBCJ-AF시리즈는 변위연성 7에서 표준실험체 LBCJ 보다 에너지소산능력이 각각 2.04~2.34, 1.63~3.02배 증가하였다.

바닥슬래브를 고려한 용접철골모멘트접합부의 내진보강 (Seismic Retrofit of Welded Steel Moment Connections Considering the Presence of Composite Floor Slabs)

  • 이철호;김성용
    • 한국강구조학회 논문집
    • /
    • 제29권1호
    • /
    • pp.25-36
    • /
    • 2017
  • 1994년 노스리지 지진 당시 발생한 용접모멘트 접합부의 취성파괴는 주로 보 하부 플랜지에서 발생하였다. 특히 국내 기존 용접철골모멘트 접합부의 경우 과다한 전단스터드 배치에 따른 의도치 않은 합성작용로 인해 지진 내습 시 보 하부 플랜지의 취성파단이 더욱 우려되는 실정이다. 본 논문에서는 합성효과로 인한 접합부 성능저하를 개선하기 위한 목적으로 중량전단탭/수평헌치/삼각헌치로 보강된 접합부 및 RBS가 도입된 접합부에 대한 실험을 실시하였다. 통상 기존 접합부 상부 플랜지의 수정이 불가하다는 점을 고려하여, 본 연구에서는 보 하부 플랜지에만 수평/삼각헌치를 보강하거나 RBS를 도입하여 이 때의 내진성능을 평가하였다. 실물대 실험 결과 수평/삼각헌치 혹은 중량전단탭으로 보강한 실험체는 모두 합성작용으로 인한 부작용을 극복하고 특수모멘트접합부가 요구하는 수준 이상의 소성회전각 5%이상을 발현함을 확인하였다. 또한 SRC 기둥에 RBS를 도입할 경우 접합부에 소요되는 변형의 대부분을 RBS측에서 일어나도록 유도함으로써 SRC기둥에 발생하는 손상을 방지하는 효과가 있음을 규명하였다. 이 중 중량전단탭 보강에 따른 접합부의 거동을 분석하기 위하여 추가의 수치해석 연구를 실시하였으며, 제시한 각각의 보강안에 대한 권장상세를 제시하였다.

고연성 PET 섬유로 보강된 철근콘크리트 원형 기둥의 내진성능 (Seismic Performance of Circular RC Columns Retrofitted Using Ductile PET Fibers)

  • 소라삭 바치라판야쿤;임명관;최동욱
    • 콘크리트학회논문집
    • /
    • 제28권3호
    • /
    • pp.289-298
    • /
    • 2016
  • 휨강도 및 연성이 부족한 철근콘크리트 원형 기둥의 섬유를 사용한 내진보강에 대하여 실험적 연구를 수행하였다. 일정한 축력을 받는 4개 기둥의 횡 방향 유사동적 실험에서 변수는 GF, PET 및 PET+GF 혼합 보강(HF) 등 섬유의 종류이었다. 이 연구에 적용한 PET는 인장강도(600 MPa 이상)가 우수하고 고연성(약 15%)이나, 탄성계수가 GF의 1/6 수준으로 매우 낮다. 기둥 실험 결과, 모든 보강 기둥은 컨트롤 기둥보다 7~20% 증가한 휨강도를 보였고, 연성은 1.6~1.8배로 증가하였다. 무보강 기둥은 주근 좌굴, GF 및 HF 보강 기둥의 최종 파괴모드는 GF 파단이었으나, 고연성 PET는 극한단계에서도 파단이 발생하지 않았다. PET는 휨강도 및 연성 증진 측면에서 RC 부재의 보강용으로 적합하다고 사료되나, 탄성계수가 낮으므로 많은 양을 사용하여야 하는 단점이 있으므로 이 연구에서 PET는 GF에 비해 인장 강성비 20% 수준으로 사용하였다. 한편 PET의 내구성에 대하여는 현재 연구가 진행 중에 있다.

KIESSI-3D 프로그램을 이용한 대형 3차원 SSI 해석 (Large-scale 3D SSI Analysis using KIESSI-3D Program)

  • 이은행;김재민;서춘교
    • 한국전산구조공학회논문집
    • /
    • 제26권6호
    • /
    • pp.439-445
    • /
    • 2013
  • 단단한 암반이 아닌 지반에 건설된 구조물의 지진응답을 정확하게 평가하기 위해서는 지반-구조물 상호작용(SSI)의 영향을 고려하여야 한다. 최근에는 USNRC SRP 3.7.2와 같은 원전설계분야의 규제지침 강화로 인해 SSI 해석의 필요성이 증가되고 있다. 이 연구에서는 대형 3차원 SSI 해석에 KIESSI-3D 프로그램을 사용한 사례를 제시하고 해석시간 및 정확성에 대한 토의를 하였다. 이를 위하여 대형 3차원 구조물 예제에 대한 SSI 해석을 수행하고 해석결과와 해석시간을 ACS/SASSI 프로그램과 비교하였다. 비교결과 KIESSI-3D 프로그램과 ACS/SASSI 프로그램에 의해 구한 구조응답의 전달함수가 거의 동일함을 보여 KIESSI-3D 프로그램의 정확성을 확인할 수 있었다. 아울러 해석시간 측면에서는 다중 쓰레드를 사용한 KIESSI-3D 프로그램(8개 쓰레드)이 단일 쓰레드를 사용한 ACS/SASSI 프로그램 보다 약 30배~2000배 빠른 성능을 보였다.

매입형 CFRP Rod와 CFRP시트를 활용한 RC 외부 보-기둥 접합부의 내진성능 평가 및 개선 (Improvement and Evaluation of Seismic Performance of Reinforced Concrete Exterior Beam-Column Joints using Embedded CFRP Rods and CFRP Sheets)

  • 하기주;강현욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.40-48
    • /
    • 2014
  • 본 연구에서는 기존 철근콘크리트 건물의 보-기둥 접합부의 내진성능의 개선을 위해 보-기둥 접합부 영역을 FRP보강재(매입형 CFRP Rod, CFRP시트)를 사용하여 보강한 후 내진성능을 평가하였다. 총 6개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 본 연구의 실험결과를 근거로 다음과 같은 결론을 얻었다. 기존 철근콘크리트 보-기둥 접합부의 접합부 영역을 보강한 결과, 초기 재하시 접합부 영역의 균열억제 효과와 재하 전 과정을 통하여 보강재의 구속효과로 인하여 균열억제 효과가 커서 안정적인 파괴형태 및 내력향상 효과를 나타내었다. 매입형 CFRP Rod와 CFRP시트를 활용한 RC 외부 보-기둥 접합부 실험체 RBCJ-SRC2는 표준실험체 RBCJ와 비교하여 변위연성4, 7에서 각각 최대 내력은 1.97배, 에너지소산능력은 2.08배 증가하였다. 또한, 실험체 RBCJ-SR시리즈와 비교하여 최대내력이 1.09~1.11배 증가하였다. 그리고 실험체 RBCJ-CS, RBCJ-SR시리즈, RBCJ-SRC2는 변위연성 5, 6에서 표준실험체 RBCJ 보다 에너지소산능력이 1.10~2.30배 증가하였다. 그리고 에너지소산능력은 변위연성 4에서 13.0~14.4% 증가하였다.