• 제목/요약/키워드: Seismic strengthening

검색결과 212건 처리시간 0.032초

Evaluation of seismic strengthening techniques for non-ductile soft-story RC frame

  • Karki, Prajwol;Oinam, Romanbabu M.;Sahoo, Dipti Ranjan
    • Advances in concrete construction
    • /
    • 제9권4호
    • /
    • pp.423-435
    • /
    • 2020
  • Open ground story (OGS) reinforced concrete (RC) buildings are vulnerable to the complete collapse or severe damages under seismic actions. This study investigates the effectiveness of four different strengthening techniques representing the local and global modifications to improve the seismic performance of a non-ductile RC OGS frame. Steel caging and concrete jacketing methods of column strengthening are considered as the local modification techniques, whereas steel bracing and RC shear wall systems are selected as the global strengthening techniques in this study. Performance-based plastic design (PBPD) approach relying on energy-balance concept has been adopted to determine the required design force demand on the strengthening elements. Nonlinear static and dynamic analyses are carried out on the numerical models of study frames to assess the effectiveness of selected strengthening techniques in improving the seismic performance of OGS frame.. Strengthening techniques based on steel braces and RC shear wall significantly reduced the peak interstory drift response of the OGS frame. However, the peak floor acceleration of these strengthened frames is amplified by more than 2.5 times as compared to that of unstrengthened frame. Steel caging technique of column strengthening resulted in a reasonable reduction in the peak interstory drift response without substantial amplification in peak floor acceleration of the OSG frame.

Seismic evaluation and upgrading of RC buildings with weak open ground stories

  • Antonopoulos, T.A.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.611-628
    • /
    • 2012
  • The inelastic earthquake response of existing, reinforced concrete buildings with an open ground story, designed according to the old Greek codes, is investigated before and after their seismic strengthening with steel braces restricted to the open ground stories. The seismic performance evaluation is based on Part 3 of Eurocode 8 for assessment and retrofitting of buildings. Three and five-story, symmetric and non-symmetric buildings are subjected to a set of seven pairs of synthetic accelerograms, compatible with the design spectrum, and conclusions are drawn regarding the effectiveness of the strengthening solutions. Seismic behavior of the selected models confirms results of previous work regarding the insufficient capacity of the open ground stories for design level earthquakes. It is also shown that strengthening only the weak ground story, a choice having the substantial advantage of low cost and continued usage of the building during its seismic retrofitting, can remove the inherent weakness without shifting the problem to the stories above and thus making such buildings at least as strong as those without a weak first story. This partial strengthening is possible for symmetric as well as eccentric buildings, in which torsion plays a further detrimental role.

Experimental study on RC frame structures strengthened by externally-anchored PC wall panels

  • Choi, Seung-Ho;Hwang, Jin-Ha;Lee, Deuck Hang;Kim, Kang Su;Zhang, Dichuan;Kim, Jong Ryeol
    • Computers and Concrete
    • /
    • 제22권4호
    • /
    • pp.383-393
    • /
    • 2018
  • Infill wall strengthening method has been widely used for seismic strengthening of deteriorated reinforced concrete (RC) frame structures with non-seismic details. Although such infill wall method can ensure sufficient lateral strengths of RC frame structures deteriorated in seismic performances with a low constructional cost, it generally requires quite cumbersome construction works due to its complex connection details between an infill wall and existing RC frame. In this study, an advanced seismic strengthening method using externally-anchored precast wall panels (EPCW) was developed to overcome the disadvantage inherent in the existing infill wall strengthening method. A total of four RC frame specimens were carefully designed and fabricated. Cyclic loading tests were then conducted to examine seismic performances of RC frame specimens strengthened using the EPCW method. Two specimens were fully strengthened using stocky precast wall panels with different connection details while one specimen was strengthened only in column perimeter with slender precast wall panels. Test results showed that the strength, stiffness, and energy dissipation capacity of RC frame specimens strengthened by EPCWs were improved compared to control frame specimens without strengthening.

Study on seismic strengthening of railway bridge pier with CFRP and concrete jackets

  • Ding, Mingbo;Chen, Xingchong;Zhang, Xiyin;Liu, Zhengnan;Lu, Jinghua
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.275-283
    • /
    • 2018
  • Seismic strengthening is essential for existing bridge piers which are deficient to resist the earthquake. The concrete and CFRP jackets with a bottom-anchoring method are used to strengthen railway bridge piers with low reinforcement ratio. Quasi-static tests of scaled down model piers are performed to evaluate the seismic performance of the original and strengthened bridge pier. The fracture characteristics indicate that the vulnerable position of the railway bridge pier with low reinforcement ratio during earthquake is the pier-footing region and shows flexural failure mode. The force-displacement relationships show that the two strengthening techniques using CFRP and concrete jackets can both provide a significant improvement in load-carrying capacity for railway bridge piers with low reinforcement ratio. It is clear that the bottom-anchoring method by using planted steel bars can guarantee the CFRP and concrete jackets to work jointly with original concrete piers Furthermore, it can be found that the use of CFRP jacket offers advantages over concrete jacket in improving the energy dissipation capacity under lateral cyclic loading. Therefore, the seismic strengthening techniques by the use of CFRP and concrete jackets provide alternative choices for the large numbers of existing railway bridge piers with low reinforcement ratio in China.

기존 교각의 FRP 원통관을 이용한 내진보강의 실험연구 (The Experimental Study on the Seismic Strengthening Effect of FRP Circular Tube on the Circular Bridge Piers)

  • 황윤국;윤순종;김정호;최영민;박경훈;권태규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.973-978
    • /
    • 2003
  • This paper describes the experimental study on seismic strengthening effect of circular bridge columns with poor lap-splice details using FRP(Fiber Reinforced Plastic) wrapping, The as-built column suffered brittle failure due to the deterioration of lap-spliced longitudinal reinforcement without developing its flexural capacity or any ductility, The strengthening columns using FRP wrapping showed significant improvement in seismic performance due to FRP's confinement effect.

  • PDF

Seismic assessment of a R/C strategic existing building

  • Mehani, Youcef;Kibboua, Abderrahmane
    • Structural Engineering and Mechanics
    • /
    • 제26권6호
    • /
    • pp.617-634
    • /
    • 2007
  • Algeria is a country with a high seismic activity. During the last decade, many destructive earthquakes occurred, particularly in the northern part, causing enormous losses in human lives, buildings and equipments. In order to reduce this risk in the capital and avoid serious damages to the strategic existing buildings, the government decided to invest into seismic upgrade, strengthening and retrofitting of these buildings. In doing so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed on the basis of site investigation (inspection of the building, collecting data, materials, general conditions of the building, etc), and existing drawings (architectural plans, structural design, etc). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper will provide insight to the vulnerability assessment and strengthening of the telecommunication centre, according to the new code RPA 99/version 2003. Both, static equivalent method and non linear dynamic analysis are performed in this study.

Effect of link length in retrofitted RC frames with Y eccentrically braced frame

  • INCE, Gulhan
    • Steel and Composite Structures
    • /
    • 제43권5호
    • /
    • pp.553-564
    • /
    • 2022
  • Many existing reinforced concrete (RC) structures need to be strengthening for reason such as poor construction quality, low ductility or designing without considering seismic effects. One of the strengthening methods is strengthening technique with eccentrically braced frames (EBFs). The characteristic element of these systems is the link element and its length is very important in terms of seismic behavior. The link element of Y shaped EBF systems (YEBFs) is designed as a short shear element. Different limits are suggested in the literature for the link length. This study to aim experimentally investigate the effect of the link length for the suggested limits on the behavior of the RC frame system and efficiency of strengthening technique. For this purpose, a total of 5 single story, single span RC frame specimens were produced. The design of the RC frames was made considering seismic design deficiencies. Four of the produced specimens were strengthened and one of them remained as bare specimen. The steel YEBFs were used in strengthening the RC frame and the link was designed as a shear element that have different length with respect to suggested limits in literature. The length of links was determined as 50mm, 100mm, 150mm and 200mm. All of the specimens were tested under cyclic loads. The obtained results show that the strengthening technique improved the energy consumption and lateral load bearing capacities of the bare RC specimen. Moreover, it is concluded that the specimens YB-2 and YB-3 showed better performance than the other specimens, especially in energy consumption and ductility.

유사동적실험기반 내부접합형 합성내진보강공법을 적용한 기존 R/C 건물의 내진성능평가 (Seismic Capacity Evaluation of Existing R/C Buildings Retrofitted by Internal Composite Seismic Strengthening Method Based on Pseudo-dynamic Testing )

  • 이은경;김진영;백호진;이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권2호
    • /
    • pp.67-76
    • /
    • 2023
  • 본 연구에서는 기존 내력증진형 내진보강공법의 취약점을 개선 및 보완할 수 있는 새로운 개념의 내진보강법인 내부접합형 합성내진보강공법 (Composite Seismic Strengthening Method, CSSM)을 제안하였다. CSSM 내진보강 시스템은 필요 내진보강량 산정이 간편한 강도증진형 내진보강법의 일종으로서, 전단파괴가 지배적인 우리나라 내진상세를 가지지 않는 기존 R/C 건물에 적용 시 내력증가가 효율적으로 가능한 내진 시스템 공법이다. 제안한 내부접합형 CSSM 공법의 내진안전성을 검토하기 위하여 내진상세를 가지지 않는 우리나라 R/C 건축물을 바탕으로 한 실물 2층 골조 실험체를 대상으로 유사동적실험을 실시하여, 지진에 대한 하중 및 변위 특성, 지진피해수준, 강도증진 효과, 변위제어능력을 중심으로 내진성능을 평가하였다. 유사동적 실험결과 개발공법인 CSSM 내진시스템은 효과적으로 전단내력을 증가시켰으며, 2400년 재현주기인 지진파에 대해서도 지진에 대한 변위를 효과적으로 억제시켰다.

중·저층 철근콘크리트 건물의 SRCF 외부접합 내진보강공법의 내진성능 평가 (Seismic Performance Evaluation of Seismic Strengthening Method using SRCF External Connection of Medium and Low-rise R/C Buildings)

  • 이강석;정주성;이종권
    • 콘크리트학회논문집
    • /
    • 제27권2호
    • /
    • pp.147-155
    • /
    • 2015
  • 본 연구에서는 기존 강도증진형 내진보강법의 단점을 보완 개선할 수 있는 새로운 개념의 내진보강법인 SRCF (Steel Reinforced Concrete Frame) 외부접합형 내진보강법을 제안하였다. SRCF 보강법은 거주자가 거주가 가능하면서 내진보강 공사를 실시할 수가 있으며, 접합부 시공성이 탁월하며, 특히 필요 내진보강량 산정이 간편한 전형적인 강도증진형으로 전단파괴가 지배적인 비내진상세를 가지는 국내 중 저층 철근콘크리트 건물에는 내력확보가 용이한 내진보강공법이다. 본 연구에서 제안한 SRCF 외부접합형 공법의 유용성을 검증 할 목적으로 기존 중 저층 철근콘크리트 학교건물의 골조를 대상으로 유사동적실험을 실시하여 내진보강효과를 검토하였다. 그 결과, 국내에서 발생 가능한 최대 지진규모(300gal)에서 비보강 골조는 붕괴를 하였지만, SRCF 외부접합형 내진보강법으로 보강한 골조는 경미한 지진피해가 예상되었으며, 대규모 지진(400, 500gal)을 상정한 경우에도 소규모 이하의 지진피해가 예상되어 본 연구에서 개발한 SRCF 내진보강법의 유효성이 검증되었다고 사료된다.

Rehabilitation and strengthening of exterior RC beam-column connections using epoxy resin injection and FRP sheet wrapping: Experimental study

  • Marthong, Comingstarful
    • Structural Engineering and Mechanics
    • /
    • 제72권6호
    • /
    • pp.723-736
    • /
    • 2019
  • The efficacy of a technique for the rehabilitation and strengthening of RC beam-column connections damaged due to cyclic loading was investigated. The repair mainly uses epoxy resin infused under pressure into the damaged region to retrieved back the lost capacity and then strengthening using fiber reinforced polymer (FRP) sheets for capacity enhancement. Three common types of reduced scale RC exterior beam-column connections namely (a) beam-column connection with beam weak in flexure (BWF) (b) beam-column connections with beam weak in shear (BWS) and (c) beam-column connections with column weak in shear (CWS) subjected to reversed cyclic loading were considered for the experimental investigation. The rehabilitated and strengthened specimens were also subjected to similar cyclic displacement. Important parameters related to seismic capacity such as strength, stiffness degradation, energy dissipation, and ductility were evaluated. The rehabilitated connections exhibited equal or better performance and hence the adopted rehabilitation strategies could be considered as satisfactory. Confinement of damaged region using FRP sheet significantly enhanced the seismic capacity of the connections.