• Title/Summary/Keyword: Seismic occurrence

Search Result 151, Processing Time 0.024 seconds

A Seismic Design of RC Underground Subway Structure (지중 RC 도시지하철고 구조물의 내진설계)

  • Jeong, Jae-Pyoung;Im, Tong-Won;Lee, Seong-Lo;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.357-362
    • /
    • 2000
  • This Paper presents dynamic analysis of underground R/C Subway Structure, subjected to seismic actions. Earthquakes brought serious damage to RC subway Structure. Foe studying the collapse mechanism of underground RC Subway, seismic of a subway station is simulated in using FEM program ASP2000 of two-dimension based on the path dependent RC elastic model, soil foundation and interfacial models. The shear failure of intermediate vertical columns is founds to be the major cause of the structural collapse. According to FEM simulation of the failure mechanism, it is considered that the RC column would lose axial load carrying capacity after the occurrence of the localized diagonal shear cracks , and sudden failure of the outer frame would be followed. Specially, the shear stress in the middle slab reaches maximum shear capacity. So, the Structure would fail in the middle slab as a result of erasing the vertical ground motion computation.

  • PDF

Development of a Design Seismic Wave Time History Generation Technique Corresponding to the Recorded Seismic Wave-Based Design Response Spectrum (계측 지진파 기반 설계응답스펙트럼에 상응하는 설계 지진파 시간이력 생성 기법 개발)

  • Oh, Hyun Ju;Park, Hyung Choon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.687-695
    • /
    • 2021
  • With the recent occurrence of large-scale earthquakes in Korea, the importance of seismic design has greatly increased. Seismic design standards stipulate that dynamic time history analysis be performed for important or special structures. In the seismic analysis and design of such structures, determining a rational design input seismic wave is a very important factor in ensuring the reliability of the analysis and design. In the seismic design standards, rational design seismic waves must reflect the characteristics of the area (fault) and satisfy the design response spectrum for each seismic performance level. This requirement can be partially satisfied by modifying the actual seismic wave measured in the area (fault) according to the design response spectrum. In this study, a method of correcting and generating seismic wave time histories according to the design response spectrum based on actual measured seismic waves using the harmonic wavelet transform was proposed. To examine the applicability of the proposed technique, the technique was applied to earthquakes of magnitude 5.8 and 5.4, respectively, that occurred in Gyeongju (2016) and Pohang (2017), and the seismic wave time histories corresponding to the design response spectrum were modified and generated.

IDENTIFICATION AND ASSESSMENT OF AGING-RELATED DEGRADATION OCCURRENCES IN NUCLEAR POWER PLANTS

  • Choi, In-Kil;Choun, Young-Sun;Kim, Min-Kyu;Nie, Jinsuo;Braverman, Joseph I.;Hofmayer, Charles H.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.3
    • /
    • pp.297-310
    • /
    • 2012
  • Aging-related degradation of nuclear power plant components is an important aspect to consider in securing the long term safety of the plant, especially the seismic safety, since the degradation of the components affects not only their seismic capacity but their response. This can cause a change in the seismic margin of a component and the overall seismic safety of a system. To better understand the status and characteristics of degradation of components in Nuclear Power Plants (NPPs), the degradation occurrences of components in the U.S. NPPs were identified by reviewing recent publicly available information sources and the characteristics of these occurrences were evaluated and compared to observations from the past. Ten categories of components that are of high risk significance in Korean NPPs were identified, comprising anchorage, concrete, containment, exchanger, filter, piping systems, reactor pressure vessels, structural steel, tanks, and vessels. Software tools were developed to expedite the review process. Results from this review effort were compared to previous data in the literature to characterize the overall degradation trends.

Probabilistic estimation of seismic economic losses of portal-like precast industrial buildings

  • Demartino, Cristoforo;Vanzi, Ivo;Monti, Giorgio
    • Earthquakes and Structures
    • /
    • v.13 no.3
    • /
    • pp.323-335
    • /
    • 2017
  • A simplified framework for the probabilistic estimation of economic losses induced by the structural vulnerability in single-story and single-bay precast industrial buildings is presented. The simplifications introduced in the framework are oriented to the definition of an expeditious procedure adoptable by government agencies and insurance companies for preliminary risk assessment. The economic losses are evaluated considering seismic hazard, structural response, damage resulting from the structural vulnerability and only structural-vulnerability-induced e]conomic losses, i.e., structural repair or reconstruction costs (stock and flow costs) and content losses induced by structural collapse. The uncertainties associated with each step are accounted for via Monte Carlo simulations. The estimation results in a probabilistic description of the seismic risk of portal-like industrial buildings, expressed in terms of economic losses for each occurrence (i.e., seismic event) that owners (i.e., insured) and stakeholders can use to make risk management decisions. The outcome may also be useful for the definition of the insurance premiums and the evaluation of the risks and costs for the owner corresponding to the insurance industrial costs. A prototype of a precast concrete industrial building located in Mirandola, Italy, hit by the 2012 Emilia earthquake, is used as an example of the application of the procedure.

Inelastic Behavior and Seismic Retrofit of Inverted V Braced Steel Frames (역V형 철골 가새골조의 비탄성거동 및 내진성능향상 방안에 관한 연구)

  • Kim, Nam Hoon;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.571-578
    • /
    • 2003
  • An effective seismic retrofit scheme for inverted V braced (or chevron type) steel frames was proposed by studying the redistribution of forces in the post-buckling range. The steel frames with chevron bracing are highly prone to soft story response once the compression brace buckles under earthquake loading. This paper shows that the seismic performance of such frames could be significantly improved by supplying tie bars to redistribute the inelastic deformation demand over the height of the building. A practical design method of the retrofit tie bars was also proposed by considering the sequence of buckling occurrence.

Seismic assessment and finite element modelling of glazed curtain walls

  • Caterino, Nicola;Zoppo, Marta Del;Maddaloni, Giuseppe;Bonati, Antonio;Cavanna, Giovanni;Occhiuzzi, Antonio
    • Structural Engineering and Mechanics
    • /
    • v.61 no.1
    • /
    • pp.77-90
    • /
    • 2017
  • Glazed curtain walls are façade systems frequently chosen in modern architecture for mid and high-rise buildings. From recent earthquakes surveys it is observed the large occurrence of non-structural components failure, such as storefronts and curtain walls, which causes sensitive economic losses and represents an hazard for occupants and pedestrians safety. In the present study, the behavior of curtain wall stick systems under seismic actions has been investigated through experimental in-plane racking tests conducted at the laboratory of the Construction Technologies Institute (ITC) of the Italian National Research Council (CNR) on two full-scale aluminium/glass curtain wall test units. A finite element model has been calibrated according to experimental results in order to simulate the behavior of such components under seismic excitation. The numerical model investigates the influence of the interaction between glass panels and aluminium frame, the gasket friction and the stiffness degradation of aluminium-to-glass connections due to the high deformation level on the curtain walls behavior. This study aims to give a practical support to researchers and/or professionals who intend to numerically predict the lateral behavior of similar façade systems, so as to avoid or reduce the need of performing expensive experimental tests.

Behavior of Reinforced Earth Retaining Wall by Shaking Table Test (진동대 모형실험을 통한 보강토 옹벽의 거동 특성)

  • Yoon, Won-Sub;Yoon, Bu-Yeol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.637-647
    • /
    • 2019
  • In this study, we analyzed seismic behavior of reinforced earth retaining wall through the model test in order to characterize the behavior of reinforced earth retaining wall during earthquake. A scale model test was performed based on similitude ratio in accordance with law of similitude due to time and financial constraints on real scale modeling experiments. Seismic resistance characteristics of each seismic waves were analyzed by assessing the variations measured through excitation of the excited acceleration of 0.05g, 0.1g, 0.15g, and 0.2g. The results of this study, it would be important to obtain reasonable and abundant data on ground properties and seismic design in preparation for earthquakes when assessing the safety of block type reinforced earth retaining wall confined to model experiment. Acquisition of those data and systematic analytical techniques are considered likely to have a significant effect on the decrease of structure damage caused by earthquakes in Korea which has recently witnessed frequent occurrence of earthquakes.

An investigation into adequacy of separation gap to preclude earthquake-induced pounding

  • Yazan Jaradat;Pejman Sobhi and Harry Far
    • Structural Engineering and Mechanics
    • /
    • v.86 no.1
    • /
    • pp.29-48
    • /
    • 2023
  • Pounding happens when contiguous structures with differing heights vibrate out of line caused by a seismic activity. The situation is aggravated due to the insufficient separation gap between the structures which can lead to the crashing of the buildings or total collapse of an edifice. Countries around the world have compiled building standards to address the pounding issue. One of the strategies recommended is the introduction of the separation gap between structures. AS1170.4-2007 is an Australian standard that requires 1% of the building height as a minimum separation gap between buildings to preclude pounding. This article presents experimental and numerical tests to determine the adequacy of this specification to prevent the occurrence of seismic pounding between steel frame structures under near-field and far-field earthquakes. The results indicated that the recommended minimum separation gap based on the Australian Standard is inaccurate if low-rise structure in a coupled case is utilised under both near and far field earthquakes. The standard is adequate if a tall building is involved but only when a far-field earthquake happens. The research likewise presents results derived by using the ABS and SRSS methods.

Seismic Performance Assessment of Existing Circular Sectional RC Bridge Columns according to Lap-splice Length of Longitudinal Bars (축방향철근의 겹침이음길이에 따른 원형 RC교각의 내진성능평가)

  • Park, Kwang Soon;Seo, Hyeong Yeol;Kim, Tae-Hoon;Kim, Ick Hyun;Sun, Chang Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.201-212
    • /
    • 2014
  • The plastic hinge region of RC pier ensures its nonlinear behavior during strong earthquake events. It is assumed that the piers secure sufficient strength and ductility in order to prevent the collapse of the bridge during strong earthquake. However, the presence of a lap-splice of longitudinal bars in the plastic hinge region may lead to the occurrence of early bond failure in the lap-splice zone and result in significant loss of the seismic performance. The current regulations for seismic performance evaluation limit the ultimate strain and displacement ductility considering the eventual presence of lap-splice, but do not consider the lap-splice length. In this study, seismic performance test and analysis are performed according to the cross-sectional size and the lap-splice length in the case of longitudinal bars with lap-splice located in the plastic hinge region of existing RC bridge columns with circular cross-section. The seismic behavioral characteristics of the piers are also analyzed. Based upon the results, this paper presents a more reasonable seismic performance evaluation method considering the lap-splice length and the cross-sectional size of the column.

Optimal Seismic Design Method Based on Genetic Algorithms to Induce a Beam-Hinge Mechanism in Reinforced Concrete Moment Frames (철근콘크리트 모멘트골조의 보-힌지 붕괴모드를 유도하는 유전자알고리즘 기반 최적내진설계기법)

  • Se-Woon Choi
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.6
    • /
    • pp.399-405
    • /
    • 2023
  • This study presents an optimal seismic design method based on genetic algorithms to induce beam-hinge collapse mechanisms in reinforced concrete moment frames. Two objective functions are used. The first minimizes the cost of the structure and the second maximizes the energy dissipation capacity of the structure. Constraints include strength conditions of columns and beams, minimum conditions for column-to-beam flexural strength ratio, and conditions for preventing plastic hinge occurrence of columns. Linear static analysis is performed to evaluate the strength of members, whereas nonlinear static analysis is carried out to evaluate energy dissipation capacity and occurrence of plastic hinges. The proposed method was applied to a four-story example structure, and it was confirmed that solutions for inducing a beam-hinge collapse mechanism are obtained. The value of the column-beam flexural strength ratio of the obtained design was found to be larger than the value suggested by existing seismic codes. A more robust strategy is needed to induce a beam-hinge collapse mode.