• 제목/요약/키워드: Seismic mass

검색결과 501건 처리시간 0.03초

원자로내부구조물의 동적해석을 위한 비선형모델 (A Non-linear Model for Dynamic Analysis of Reactor Internals)

  • Myung-J.Jhun;Sang-G.Chang;Song, Heuy-G.
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.165-172
    • /
    • 1993
  • A non-linear mathematical model has been developed for the dynamic analysis of the reactor internals. The model includes a lumped mass and stiffness with non-linear members such as gap-spring. As hydrodynamic couplings have also been considered in the model, the effect of fluid/structure interaction between internals components due to their immersion in a confining fluid can be studied for the dynamic response analysis. The reactor internals responses for seismic and pipe break excitations have been calculated for the case of with-and without-hydrodynamic couplings.

  • PDF

On the assessment of modal nonlinear pushover analysis for steel frames with semi-rigid connections

  • Zarfam, Panam;Mofid, Massood
    • Structural Engineering and Mechanics
    • /
    • 제32권3호
    • /
    • pp.383-398
    • /
    • 2009
  • Applying nonlinear statistical analysis methods in estimating the performance of structures in earthquakes is strongly considered these days. This is due to the methods' simplicity, timely lower cost and reliable estimation in seismic responses in comparison with time-history nonlinear dynamic analysis. Among nonlinear methods, simplified to be incorporated in the future guidelines, Modal Pushover Analysis, known by the abbreviated name of MPA, simply models nonlinear behavior of structures; and presents a very proper estimation of nonlinear dynamic analysis using lateral load pattern appropriate to the mass. Mostly, two kinds of connecting joints, 'hinge' and 'rigid', are carried out in different type of steel structures. However, it should be highly considered that nominal hinge joints usually experience some percentages of fixity and nominal rigid connections do not employ totally rigid. Therefore, concerning the importance of these structures and the significant flexibility effect of connections on force distribution and elements deformation, these connections can be considered as semi-rigid with various percentages of fixity. Since it seems, the application and implementation of MPA method has not been studied on moment-resistant steel frames with semi rigid connections, this research focuses on this topic and issue. In this regard several rigid and semi-rigid steel bending frames with different percentages of fixity are selected. The structural design is performed based on weak beam and strong column. Followed by that, the MPA method is used as an approximated method and Nonlinear Response History Analysis (NL-RHA) as the exact one. Studying the performance of semi-rigid frames in height shows that MPA technique offers reasonably reliable results in these frames. The methods accuracy seems to decrease, when the number of stories increases and does decrease in correlation with the semi-rigidity percentages. This generally implies that the method can be used as a proper device in seismic estimation of different types of low and mid-rise buildings with semi-rigid connections.

다층 비좌굴 가새골조와 등가 단자유도계의 에너지 요구량의 비교 (Comparison of Energy Demand in Multi-Story Buckling Restrained Braced Frame and Equivalent SDOF System)

  • 김진구;원영섭
    • 한국전산구조공학회논문집
    • /
    • 제16권2호
    • /
    • pp.173-182
    • /
    • 2003
  • 비선형 정적해석 및 에너지를 이용한 설계방법에서는 구조물을 등가의 단자유도계로 치환하여 해석하는 것이 일반적이다. 본 연구에서는 지진하중에 의한 3층, 8층, 20층 철골 모멘트저항골조(MRF), 비좌굴 가새골조(BRBF)와 힌지접합 비좌굴 가새골조 (DTBF) 구조물의 에너지 요구량을 등가 단자유도계 시스템(ESDOF)의 에너지 요구량과 비교하여 등가단자유도계로 치환하는 방법의 타당성을 검토하였다 입력에너지와 이력에너지를 산정하기 위하여 연암 지반, 연약한 토사, 단층 근처의 지반에서 계측된 60개의 지진을 사용하였으며, 모드 질량계수가 0.8보다 작은 경우 ESDOF로 변환할 때 고차모드의 효과를 고려하였다. 연구결과에 따르면 3층과 8층 MRF와 DTBF에서의 이력에너지와 입력에너지는 ESDOF의 해석결과와 비교적 잘 일치하였다. 그러나 20층 BRBF에서는 ESDOF의 결과가 본 구조물의 결과를 과소평가하는 것으로 나타났다.

건축구조물의 지진응답제어를 위한 MR 감쇠기 예비설계절차 (Preliminary Design Procedure of MR Dampers for Controlling Seismic Response of Building Structures)

  • 이상현;민경원;이루지;김중구
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.55-64
    • /
    • 2004
  • 본 연구의 목적은 건축구조물의 지진응답제어를 위한 MR 감쇠기의 크기, 개수 및 최적위치를 결정하는 설계절차를 제안하는 것이다. 기존의 연구에서 제안된 MR 감쇠기의 모델링 방법들의 특성과 차이점을 진동제어효과의 관점에서 분석하였으며, 이 모델 중 해석이 간단하고 이력특성을 모사할 수 있는 이력 이점성 모델을 사용하여 MR 감쇠기의 변수연구를 수행하였다. 건축구조물의 층간에 설치되는MR 감쇠장치의 용량은 지진응답의 경우 구조물의 주기와 감쇠비에 따라 층전단력이 다르게 됨을 고려하여, 20개의 지진하중에 대한 해석으로부터 구한 응답스펙트럼을 이용하여 결정하였으며, 설치 갯수에 따른 제어경향을 분석하였다. MR 감쇠기의 크기, 개수, 그리고 최적위치를 결정하기 위한 방법이 제안되었으며, 기존의 점성감쇠기 설계시 이용되는 층간변위 혹은 층간속도가 가장 큰 층에 순차적으로 설치하는 방법과의 비교를 통해 유효성을 검증하였다. 수치해석결과는 제안된 방법을 사용하여 MR 감쇠기의 크기, 개수, 그리고 위치를 합리적으로 결정할 수 있음을 보여준다.

핵석을 포함하는 풍화사면에서의 지구물리탐사 적용사례 연구 (Case Study on Application of Geophysical Survey in the Weathered Slope including Core Stones)

  • 홍원표;김재홍;노병돈;정교철
    • 지질공학
    • /
    • 제19권1호
    • /
    • pp.89-98
    • /
    • 2009
  • 암반내의 핵석의 존재는 불안전한 요소로 작용하고 있으며 특히, 절개사면의 경우 노출이 되지 않더라도 핵석이 풍화정도의 차이에 따라 사면의 불연속면 증가 또는 강도 감소가 되며 사면의 낙석이나 붕괴등 사면 거동의 중요한 요소로 작용한다. 연구대상 사면은 20여년전 절개가 완료되어 일부분 사면보강을 완료하였으나 적은 강우에도 잦은 낙석이 발생하여 항구적인 안정대책이 시급한 실정이었다 탄성파탐사와 사면지질조사 견과를 비교 분석하여 핵석의 분포특성 및 규모를 파악할 수 있었다. 또한 주변 암반사면에서 DIPS 프로그램을 이용한 평시투영을 실시하여 주변 풍화토 사면에서의 핵석 분포특성 및 규모 파악에 대하여 검토하였다.

변위기반설계법에 의한 철근콘크리트 기둥의 보강설계 (Retrofit Design of RC Column by Displacement-Based-Design Method)

  • 임청권;권민호;하금희;김진섭
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2804-2811
    • /
    • 2012
  • 본 연구에서는 직접변위기반 설계법에 의하여 철근콘크리트 기둥이 목표변위에 도달하도록 하는 보강설계를 수행하였다. 철근콘크리트 기둥의 비선형 거동은 등가 선형 시스템으로 단순화하여 해석한다. 먼저 목표변위를 결정하고, 단자유도 시스템의 등가고유주기를 추정하기 위하여 탄성 변위스펙트럼을 작성하였다. 고유주기가 결정되면 시스템의 질량을 근거로 강성을 이용하여 요구강도를 계산한다. 이후 비선형 층상화 단면해석을 통해 얻어진 하중-변위관계에 따라 요구강도를 만족하는 보강설계를 수행하였다. 비선형 층상화 단면해석 프로그램을 개발하고 보강설계 절차를 제안하였으며 이를 적용한 결과, 보강설계를 통해 보강한 철근콘크리트 기둥은 보강하지 않은 기둥과 비교하여 내진 성능이 향상 된 것을 확인 할 수 있었다.

지진시 도시가스 공급정지를 위한 긴급대응시스템의 제안 및 적용 (Proposal and Implementation of Emergency Response System of Gas Shut-off in Earthquake)

  • 정효순;김익현;이종석
    • 한국지진공학회논문집
    • /
    • 제12권6호
    • /
    • pp.25-33
    • /
    • 2008
  • 지진 시 광범위한 가스누출에 의한 화재는 인명피해 및 심각한 재산손실을 초래한다. 이러한 지진피해를 줄이는 효과적이 고도 합리적인 방법의 하나로 가스공급정지를 고려할 수 있다. 우리나라의 지진세기와 빈도 및 도시가스의 공급체계를 생각하면 지진시 가스공급정지는 일반 가정에서 개별차단기를 설치하여 실시하는 것보다 도시가스사에서 일괄적으로 수행하는 것이 보다 경제적이다. 본 연구에서는 지진 시 신속하게 가스공급 정지를 판단할 수 있는 긴급대응시스템을 제안하였다. 가스 공급지역내에서 계측된 지반가속도의 크기에 따라 적절한 조치를 취할 있도록 2단계의 기준지진도를 제안하였으며, 지진 피해를 입은 지역에 한해서 가스공급을 정지할 수 있도록 공급지역 블록화를 제안하였다. 또한, 실제 가스공급지역을 대상으로 하여 지반해석과 피해도 해석을 수행하여 기준지진도를 설정하고 긴급대응시스템을 적용하였다.

지진하중을 받는 사장교를 위한 $\mu$-합성법을 이용한 복합시스템 (Hybrid System Controlled by a $\mu-Synthesis$ Method for a Seismically Excited Cable-Stayed Bridge)

  • 박규식;정형조;최강민;이종헌;이인원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.574-577
    • /
    • 2004
  • This paper presents a hybrid system combining lead rubber bearings and hydraulic actuators controlled by a $\mu-synthesis$ method for seismic response control of a cable-stayed bridge. A hybrid system could alleviate some of restrictions and limitations that exist when each system is acting alone because multiple control devices are operating. Therefore, the overall control performance of a hybrid system may be improved compared to each system, however the overall system robustness may be negatively impacted by active device in the hybrid system or active controller may cause instability due to small margins. Therefore, a $\mu-synthesis$ method that guarantees the robust performance is considered to enhance the possibility of real applications of the control system. The performances of the proposed control system are compared with those of passive, active, semiactive control systems and hybrid system controlled by a LQG algorithm. Furthermore, an extensive robust analysis with respect to stiffness and mass matrices perturbation and time delay of actuator is performed. Numerical simulation results show that the performances of the proposed control system are superior to those of passive system and slightly better than those of active and semiactive systems and two hybrid systems show similar control performances. Furthermore, the hybrid system controlled by a f-synthesis method shows the good robustness without loss of control performances. Therefore, the proposed control system could effectively be used to seismically excited cable-stayed bridge which contains many uncertainties.

  • PDF

Structural health rating (SHR)-oriented 3D multi-scale finite element modeling and analysis of Stonecutters Bridge

  • Li, X.F.;Ni, Y.Q.;Wong, K.Y.;Chan, K.W.Y.
    • Smart Structures and Systems
    • /
    • 제15권1호
    • /
    • pp.99-117
    • /
    • 2015
  • The Stonecutters Bridge (SCB) in Hong Kong is the third-longest cable-stayed bridge in the world with a main span stretching 1,018 m between two 298 m high single-leg tapering composite towers. A Wind and Structural Health Monitoring System (WASHMS) is being implemented on SCB by the Highways Department of The Hong Kong SAR Government, and the SCB-WASHMS is composed of more than 1,300 sensors in 15 types. In order to establish a linkage between structural health monitoring and maintenance management, a Structural Health Rating System (SHRS) with relevant rating tools and indices is devised. On the basis of a 3D space frame finite element model (FEM) of SCB and model updating, this paper presents the development of an SHR-oriented 3D multi-scale FEM for the purpose of load-resistance analysis and damage evaluation in structural element level, including modeling, refinement and validation of the multi-scale FEM. The refined 3D structural segments at deck and towers are established in critical segment positions corresponding to maximum cable forces. The components in the critical segment region are modeled as a full 3D FEM and fitted into the 3D space frame FEM. The boundary conditions between beam and shell elements are performed conforming to equivalent stiffness, effective mass and compatibility of deformation. The 3D multi-scale FEM is verified by the in-situ measured dynamic characteristics and static response. A good agreement between the FEM and measurement results indicates that the 3D multi-scale FEM is precise and efficient for WASHMS and SHRS of SCB. In addition, stress distribution and concentration of the critical segments in the 3D multi-scale FEM under temperature loads, static wind loads and equivalent seismic loads are investigated. Stress concentration elements under equivalent seismic loads exist in the anchor zone in steel/concrete beam and the anchor plate edge in steel anchor box of the towers.

TEMPORAL VARIATIONS OF THE GLOBAL SEISMIC PARAMETERS OF HD 49933 OVER A MAGNETIC CYCLE

  • Kim, Ki-Beom;Chang, Heon-Young
    • 천문학회지
    • /
    • 제54권4호
    • /
    • pp.129-137
    • /
    • 2021
  • It has been established that the acoustic mode parameters of the Sun and Sun-like stars vary over activity cycles. Since the observed variations are not consistent with an activity-related origin, even Sun-like stars showing out-of-phase changes of mode frequencies and amplitudes need to be carefully studied using other observational quantities. In order to test whether the presumed relations between the global seismic parameters are a signature of the stellar activity cycle, we analyze the photometric light curve of HD 49933 for which the first direct detection of an asteroseismic signature for activity-induced variations in a Sun-like star was made, using observations by the CoRoT space telescope. We find that the amplitude of the envelope significantly anti-correlates with both the maximum frequency of the envelope and the width of the envelope unless superflare-like events completely contaminate the light curve. However, even though the photometric proxy for stellar magnetic activity appears to show relations with the global asteroseismic parameters, they are statistically insignificant. Therefore, we conclude that the global asteroseismic parameters can be utilized in cross-checking asteroseismic detections of activity-related variations in Sun-like stars, and that it is probably less secure and effective to construct a photometric magnetic activity proxy to indirectly correlate the global asteroseismic parameters. Finally, we seismically estimate the mass of HD 49933 based on our determination of the large separation of HD 49933 with evolutionary tracks computed by the MESA code and find a value of about 1.2M and a sub-solar metallicity of Z = 0.008, which agrees with the current consensus and with asteroseismic and non-asteroseismic data.