• Title/Summary/Keyword: Seismic mass

Search Result 501, Processing Time 0.027 seconds

Influence of Effective Piezoelectric Properties on Performance of Piezoelectric Accelerometer for Vibration Measurements (진동 측정용 압전형 가속도센서의 압전특성 효과)

  • 권정락
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.8
    • /
    • pp.945-949
    • /
    • 1995
  • In order to investigate the performance of compression-type accelerometer on piezoelectric properties, PZT materials have been studied. The ring-shaped piezoelectric elements were prepared using commercial PZT powders by conventional ceramic process. Their estimated relative dielectric constant, piezoelectric charge constant (d33) and voltage constant (g33) values showed 390∼3400, (90∼593)×10-12 C/N and (19.5∼40.5)×10-3 V-m/N, respectively. The charge sensitivity of accelerometer is proportional to the piezoelectric charge constant value (d33) of PZT, but its voltage sensitivity is related with the piezoelectric voltage constant (g33). Since the mounted resonance frequency and sensitivity are dependent on the seismic mass as well as physical charateristics and size of PZT elements, the suitable considerations between two components are required for accelerometer's design.

  • PDF

Fabrication and Testing of a Polysilicon Piezoresistive Accelerometer using p+ Silicon Diaphragm (p+ 실리콘 박막을 이용한 폴리실리콘 압저항 가속도계의 제작 및 측정)

  • Yang, E.H.;Jeong, O.C.;Yang, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1994-1996
    • /
    • 1996
  • This paper presents the fabrication and testing of a polysilicon piezoresistive accelerometer with p+ silicon diaphragm by simple process such as two step photolithography for the RIE process to form the cantilevers and a deep anisotropic etch process for the complete fabrication of the accelerometer. The fabricated accelerometer consists of a seismic mass and four cantilevers on which polysilicon piezoresistors are formed. The measurement of the output signal from the bridge circuit of the fabricated accelerometer is carried out with the HP 3582A spectrum analyzer. The analysis of the experimental result is showed in terms of the sensitivity and the resonant frequency. At atmospheric condition, the measurement values of the sensitivity and the resonant frequency are $11\;{\mu}V/Vg$ and 475 Hz, respectively.

  • PDF

Mechanism Modeling and Structural Analysis of the Fuel Handling Machine in KALIMER Reactor (KALIMER 원자로 핵연료 교환기의 메커니즘 모델링 및 구조해석)

  • 김석훈;이재한
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.131-138
    • /
    • 2002
  • The fuel handling machine handles the core assembly in refueling period of the reactor, it is necessary to predict the motion and structural integrity of it. The kinetic analysis of the fuel handling machine was carried out for the refueling motion. The reaction forces at the joints of machine were calculated with IDEAS code considering the weight of the machine and the loading force of the core assembly, Also, the structural analysis for the machine modeled by lumped-mass and beam elements was performed by using ANSYS code. The stresses and deformations were calculated for the equivalent static force based on the kinetic analysis and the seismic loads. The calculated displacements and stresses are quite low compared with allowable limits.

  • PDF

Preliminary Structural Design of Wall-Frame Systems for Optimum Torsional Response

  • Georgoussis, George K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.45-58
    • /
    • 2017
  • Recent investigations have pointed out that current code provisions specifying that the stiffness of reinforced concrete elements is strength independent, and therefore can be estimated prior to any strength assignment, is incorrect. A strength allocation strategy, suitable for preliminary structural design of medium height wall-frame dual systems, is presented for allocating strength in such buildings and estimating the dependable rigidities. The design process may be implemented by either the approximate continuous approach or the stiffness matrix method. It is based on the concept of the inelastic equivalent single-degree-of-freedom system which, the last few years, has been used to implement the performance based seismic design. The aforesaid strategy may also be used to determine structural configurations of minimum rotation distortion. It is shown that when the location of the modal centre of rigidity, as described in author's recent papers, is within a close distance from the mass axis the torsional response is mitigated. The methodology is illustrated in ten story building configurations, whose torsional response is examined under the ground motion of Kobe 1995, component KJM000.

Stochastic response analysis of visco-elastic slit shear walls

  • Kwan, A.K.H.;Tian, Q.L.;Cheung, Y.K.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.4
    • /
    • pp.377-394
    • /
    • 1998
  • Slit shear walls an reinforced concrete shear wall structures with purposely built-in vertical slits. If the slits are inserted with visco-elastic damping materials, the shear walls will become viscoelastic sandwich beams. When adequately designed, this kind of structures can be quite effective in resisting earthquake loads. Herein, a simple analysis method is developed for the evaluation of the stochastic responses of visco-elastic slit shear walls. In the proposed method, the stiffness and mass matrices are derived by using Rayleigh-Ritz method, and the responses of the structures are calculated by means of complex modal analysis. Apart from slit shear walls, this analysis method is also applicable to coupled shear walls and cantilevered sandwich beams. Numerical examples are presented and the results clearly show that the seismic responses of shear wall structures can be substantially reduced by incorporating vertical slits into the walls and inserting visco-elastic damping materials into the slits.

Variability in bridge frequency induced by a parked vehicle

  • Chang, K.C.;Kim, C.W.;Borjigin, Sudanna
    • Smart Structures and Systems
    • /
    • v.13 no.5
    • /
    • pp.755-773
    • /
    • 2014
  • The natural frequency of a bridge is an important parameter in many engineering applications such as bridge seismic design and modal-based bridge health monitoring. The natural frequency of a bridge vibrating alone may differ from that vibrating along with a vehicle. Although such vehicle-induced variability in bridge frequency is revealed in several experimental and numerical simulation studies, few attempts have been made on the theoretical descriptions. In this study, both theoretically and experimentally, the variability in the bridge frequency induced by a parked vehicle is verified, and is therefore suggested to be considered in bridge-related engineering, especially for those cases with near vehicle-bridge resonance conditions or with large vehicle-to-bridge mass ratios. Moreover, the variability ranges could be estimated by an analytical formula presented herein.

Application of TMD to Reduce Seismic Response of Arch Structure (아치구조물의 지진응답 저감을 위한 TMD의 적용)

  • Kim, Gee-Cheol;Kang, Joo-Won;Kim, Hyun-Su
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.27-30
    • /
    • 2010
  • TMD(Tuned Mass Damper)는 대표적인 제진장치로서 주로 고층건물, 교량 및 스타디움의 객석 등의 진동제어에 이용되고 있다. 그러나 대공간구조물과 같이 면외 방향의 강성이 매우 작은 구조물에 대한 TMD 적용에 대한 연구는 거의 전무한 실정이다. 본 연구에서는 아치구조물의 진동에 대한 TMD의 제어 성능을 TMD의 설치위치 및 거동방향에 따라서 비교분석하였다. 아치구조물은 수평지진동에 대해서는 역대칭모드인 1차 모드가 지배적이며, 연직지진동에 대해서는 대칭모드인 2차 모드가 지배적인 진동응답을 보이고 있다. 따라서 아치구조물의 효율적인 진동응답제어를 위해서는 진동모드가 탁월한 위치에 TMD를 설치하는 것이 합리적이다. 그리고 수평지진동 및 수직지진동에 대하여 TMD가 수평방향으로 거동하도록 하는 것보다 연직방향으로 움직이도록 설치하는 것이 아치구조물의 진동제어에 있어서 매우 효과적인 것으로 나타났다.

  • PDF

Passive vibration control of plan-asymmetric buildings using tuned liquid column gas dampers

  • Fu, Chuan
    • Structural Engineering and Mechanics
    • /
    • v.33 no.3
    • /
    • pp.339-355
    • /
    • 2009
  • The sealed, tuned liquid column gas damper (TLCGD) with gas-spring effect extends the frequency range of application up to about 5 Hz and efficiently increases the modal structural damping. In this paper the influence of several TLCGDs to reduce coupled translational and rotational vibrations of plan-asymmetric buildings under wind or seismic loads is investigated. The locations of the modal centers of velocity of rigidly assumed floors are crucial to select the design and the optimal position of the liquid absorbers. TLCGD's dynamics can be derived in detail using the extended non-stationary Bernoulli's equation for moving reference systems. Modal tuning of the TLCGD renders the optimal parameters by means of a geometrical transformation and in analogy to the classical tuned mass damper (TMD). Subsequently, fine-tuning is conveniently performed in the state space domain. Numerical simulations illustrate a significant reduction of the vibrations of plan-asymmetric buildings by the proposed TLCGDs.

Experimental Study on the Seismic Structural Responses Subjected to Different Earthquakes (지진특성에 따른 구조물의 지진응답실험)

  • 최인길;김형규;김민규;전영선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.82-89
    • /
    • 2003
  • Near-field ground motions exhibit special characteristics that are different from ordinary far-field ground motions. In this study the shaking table tests were conducted to evaluate the effect of earthquake ground motions with different characteristics on the response of the structure. The ground motions used in this study were the scenario earthquake, design earthquake, and Chi-Chi earthquake measured in TCU052 station. These earthquakes have different frequency contents. The test results show that the frequency content of ground motion is very important to the response of structures. The floor responses of structure were greatly affected by the higher modal frequencies, as well as the fundamental frequency. The responses of third floor were significantly reduced due to the interaction between the structure and the base isolated mass installed at the third floor.

  • PDF

Identifying stiffness irregularity in buildings using fundamental lateral mode shape

  • Vijayanarayanan, A.R.;Goswami, Rupen;Murty, C.V.R.
    • Earthquakes and Structures
    • /
    • v.12 no.4
    • /
    • pp.437-448
    • /
    • 2017
  • Soft or extreme soft storeys in multi-storied buildings cause localized damage (and even collapse) during strong earthquake shaking. The presence of such soft or extremely soft storey is identified through provisions of vertical stiffness irregularity in seismic design codes. Identification of the irregularity in a building requires estimation of lateral translational stiffness of each storey. Estimation of lateral translational stiffness can be an arduous task. A simple procedure is presented to estimate storey stiffness using only properties of fundamental lateral translational mode of oscillation (namely natural period and associated mode shape), which are readily available to designers at the end of analysis stage. In addition, simplified analytical expressions are provided towards identifying stiffness irregularity. Results of linear elastic time-history analyses indicate that the proposed procedure captures the irregularity in storey stiffness in both low- and mid-rise buildings.