• 제목/요약/키워드: Seismic load test

검색결과 496건 처리시간 0.026초

시험평가법을 이용한 IRB 면진장치 롤러 설계 : Part 2. 소재 열처리 (Roller Design of IRB Seismic Isolation Device Using Test Evaluation : Part II. Heat Treatment of Material)

  • 박영기;하성훈;성민상;전준철;최승복
    • 한국소음진동공학회논문집
    • /
    • 제23권4호
    • /
    • pp.332-337
    • /
    • 2013
  • This paper presents a subsequent research work on the roller design of IRB(isolation roller bearing) seismic isolation device presented in Part 1 by focusing on heat treatment. The hardness and friction factor are very important factors of material and after-treatment process selection. Normally, roller bearing consists of roller and retainer. The roller gets high pressure constantly, while the retainer gets tensile and compressive stress. Therefore, sensitive material selection and heat treatment of each part is quite important. In this experimental evaluation, carbon steel, chrome special steel and others are employed and their characteristics after heat treatment are identified. Each material is prepared by refining high frequency heat treatment. The friction factor and static load capacity of manufactured material are experimentally identified and destructive test of material is processed. Optimal material and heat treatment conditions for IRB roller bearing are determined based on experiment results.

Static finite element analysis of architectural glass curtain walls under in-plane loads and corresponding full-scale test

  • Memari, A.M.;Shirazi, A.;Kremer, P.A.
    • Structural Engineering and Mechanics
    • /
    • 제25권4호
    • /
    • pp.365-382
    • /
    • 2007
  • A pilot study has been conducted to guide the development of a finite element modeling formulation for the analysis of architectural glass curtain walls under in-plane lateral load simulating earthquake effects. This pilot study is one aspect of ongoing efforts to develop a general prediction model for glass cracking and glass fallout for architectural glass storefront and curtain wall systems during seismic loading. For this study, the ANSYS finite element analysis program was used to develop a model and obtain the stress distribution within an architectural glass panel after presumed seismic movements cause glass-to-frame contact. The analysis was limited to static loading of a dry-glazed glass curtain wall panel. A mock-up of the glass curtain wall considered in the analysis with strain gages mounted at select locations on the glass and the aluminum framing was subjected to static loading. A comparison is made between the finite element analysis predicted strain and the experimentally measured strain at each strain gage location.

이축반복하중을 받는 2주형 철근콘크리트 교각의 실험거동 (Experimental Behavior of Reinforced Concrete Column-Bent Piers under Bidirectional Repeated Loading)

  • 박창규;이범기;송희원;정영수
    • 한국지진공학회논문집
    • /
    • 제9권1호통권41호
    • /
    • pp.17-24
    • /
    • 2005
  • 기존의 RC 교각에 대한 내진성능 연구는 실험여건상 일방향 반복하중을 받는 단주교각에 집중되어 있었다. 그러나 고속도로상의 교각은 대다수가 다주교각으로 이루어져 있으므로, 본 연구에서는 국내고속도로에서 많이 사용되고 있는 2주형 교각에 대한 이축지진하중에서의 지진응답을 실험적으로 조사하였다. 실험체는 지름 400mm, 높이 2,000mm인 2주형 원형 교각 4기를 제작하였으며, $0.1f_{ck}A_g$크기의 축방향 하중작용하에서 횡방향 하중을 이축으로 교번반복 재하하였다. 실험변수는 횡구속 철근비와 주철근 겹침이음으로서 기존 단주에 대한 연구결과와 유사하게 이들 실험변수들은 교각의 내진성능에 상당한 영향을 미치고 있었다. 또한 동일하게 설계된 일축하중을 받는 단주와 이축하중을 받는 다주의 내진성능을 비교한 결과 단주의 경우 손상이 하부 소성힌지 한 곳에 집중된 반면 다주의 경우 교축직각방향 하중으로 인하여 손상이 상ㆍ하부 두 곳으로 분산되어 나타났다.

지진하중으로 인한 팔레트 랙의 파괴 거동 분석에 관한 연구 (A Study on the Analysis of the Fracture Behavior of Pallet Racks due to Earthquake Load)

  • 김충길;허광희;정성훈;김선태;서영득;고병찬
    • 대한토목학회논문집
    • /
    • 제43권2호
    • /
    • pp.157-164
    • /
    • 2023
  • 본 연구에서는 진동대 실험을 통하여 지진하중으로 인한 팔레트 랙의 손상 및 파괴 거동을 분석하고자 하였다. 팔레트 랙은 일반적인 적재설비의 한 종류로써 기둥, 보, 그리고 브레이스로 구성되어 지진하중에 저항한다. 팔레트 랙의 지진하중으로 인한 안전성을 분석하기 위하여, 실제 물류저장 시설에서 사용되고 있는 팔레트 랙을 대상으로 지진하중을 증가시켜가면서 하중으로 인한 팔레트 랙의 거동을 분석하기 위한 진동대 실험을 진행하였다. 진동대 실험 결과, 팔레트 랙은 비틀림이 발생하면서, 1층과 2층에 위치한 일부 부재의 연결부가 손상되고, 그로 인하여 적재설비가 파괴되는 것이 확인되었다.

Seismic resistance of exterior beam-column joints with non-conventional confinement reinforcement detailing

  • Bindhu, K.R.;Jaya, K.P.;Manicka Selvam, V.K.
    • Structural Engineering and Mechanics
    • /
    • 제30권6호
    • /
    • pp.733-761
    • /
    • 2008
  • The failure of reinforced concrete structures in recent earthquakes caused concern about the performance of beam column joints. Confinement of joint is one of the ways to improve the performance of beam column joints during earthquakes. This paper describes an experimental study of exterior beam-column joints with two non-conventional reinforcement arrangements. One exterior beam-column joint of a six story building in seismic zone III of India was designed for earthquake loading. The transverse reinforcement of the joint assemblages were detailed as per IS 13920:1993 and IS 456:2000 respectively. The proposed nonconventional reinforcement was provided in the form of diagonal reinforcement on the faces of the joint, as a replacement of stirrups in the joint region for joints detailed as per IS 13920 and as additional reinforcement for joints detailed as per IS 456. These newly proposed detailing have the basic advantage of reducing the reinforcement congestion at the joint region. In order to study and compare the performance of joint with different detailing, four types of one-third scale specimens were cast (two numbers in each type). The main objective of the present study is to investigate the effectiveness of the proposed reinforcement detailing. All the specimens were tested under reverse cyclic loading, with appropriate axial load. From the test results, it was found that the beam-column joint having confining reinforcement as per IS: 456 with nonconventional detailing performed well. Test results indicate that the non-conventionally detailed specimens, Type 2 and Type 4 have an improvement in average ductility of 16% and 119% than their conventionally detailed counter parts (Type1 and Type 3). Further, the joint shear capacity of the Type 2 and Type 4 specimens are improved by 8.4% and 15.6% than the corresponding specimens of Type 1 and Type 3 respectively. The present study proposes a closed form expression to compute the yield and ultimate load of the system. This is accomplished using the theory of statics and the failure pattern observed during testing. Good correlation is found between the theoretical and experimental results.

국내 발생지진에 의한 물류창고 강재 적재설비의 내진성능 평가 (Seismic Performance of Steel Industrial Storage Racks Subjected to Korea Earthquakes)

  • 전종수;최형석;서영득;김충길;허광희
    • 한국지진공학회논문집
    • /
    • 제22권3호
    • /
    • pp.149-160
    • /
    • 2018
  • This study experimentally and analytically examines the seismic vulnerability of steel rack storage frames subjected to Korea earthquakes (2016 Gyeongju earthquake and 2017 Pohang earthquake). To achieve this aim, this study selects a three-story, one-bay steel rack frame with a typical configuration of rack frame in Korea. Firstly, the local behavior for frame components is examined by performing monotonic and/or cyclic load tests and the global response and dynamic characteristics of the subject rack frame are investigated by conducting a shaking table test. The analytical model of the rack frame is then created based on the experimental results and is used to perform nonlinear time history analyses with recorded Korea earthquakes. The seismic demand of the rack frame is considerably affected by the spectral acceleration response, instead of peak ground accelerations (peak floor accelerations). Moreover, the collapse fragility curve of the rack frame is developed using incremental dynamic analyses for the Gyeongju and Pohang earthquakes. Fragility results indicate that the ground motion characteristics of these earthquakes do not significantly affect the frame vulnerability at the collapse state.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;손국원
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.52-62
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.

깊이 1200mm급 변단면보의 중간모멘트골조용 내진접합부 개발 (Beam-Column Connection with 1200mm Deep Multi-Reduced Taper Beam for Intermediate Moment Frame)

  • 정시화;알미아이유 로벨 원디므;박만우;주영규
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.135-146
    • /
    • 2019
  • Deep beam has high section modules compared with shallow beam of the same weight. However, deep beam has low rotational capacity and high possibility of brittle failure so it is not possible to apply deep beams with a long span to intermediate moment frames, which should exhibit a ductility of 0.02rad of a story drift angle of steel moment frames. Accordingly, KBC and AISC limit the beam depth for intermediate and special moment frame to 750mm and 920mm respectively. The purpose of this paper is to improve the seismic performance of intermediate moment frame with 1200mm depth beam. In order to enhance vulnerability of plastic deformation capacity of deeper beam, Multi-Reduced Taper Beam(MRTB) shape that thickness of beam flange is reinforced and at the same time some part of the beam flange width is weakened are proposed. Based on concept of multiple plastic hinge, MRTB is intended to satisfy the rotation requirement for intermediate moment frame by dividing total story drift into each hinge and to prevent the collapse of the main members by inducing local buckling and fracture at the plastic hinge location far away from connection. The seismic performance of MRTB is evaluated by cyclic load test with conventional connections type WUF-W, RBS and Haunch. Some of the proposed MRTB connection satisfies connection requirements for intermediate moment frame and shows improved the seismic performance compared to conventional connections.

외부 강재 보강으로 구성한 합성 부재의 휨 성능에 대한 실험 (Experiments on Flexural Performance of Composite Members Strengthened by External Steel Plates)

  • 황병훈;신진원;전재호;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권5호
    • /
    • pp.143-150
    • /
    • 2022
  • 이 논문은 내진 성능 향상 목적으로 외부 강재로 보강한 콘크리트 부재의 휨 성능에 대한 실험적 연구이다. 구조물을 보강하기 위하여 벽과 기둥을 보강재로 감싸는 형식의 보강 방법을 적용하였는데, 이 구조물에서 가장 긴 지간을 갖는 벽체 일부 단면을 실물 크기로 제작하여 정적 재하 실험을 수행하는 방법으로 강성 보강효과를 확인하였다. 실험 결과, 보강 단면은 충분한 보강 성능을 발현하는 것을 확인하였으나, 가력기의 용량 부족과 안전상의 문제로 파괴까지의 거동을 확인하지는 못하였다. 보강재가 벽체에 작용하는 면외방향 모멘트를 효과적으로 부담하고 있는 것을 확인하였고, 측정된 변위와 철근 변형률 등의 분석을 통하여 보강 전 부재에 비하여 부재 강성과 휨모멘트 저항능력이 향상되었음을 검증하였다.

가압고정 기계적이음을 활용한 프리캐스트 콘크리트 구조물의 준정적 및 진동대 실험 (Quasi-Static and Shaking Table Tests of Precast Concrete Structures Utilizing Clamped Mechanical Splice)

  • 성한석;안성룡;박시영;강현구
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.37-47
    • /
    • 2023
  • A new clamped mechanical splice system was proposed to develop structural performance and constructability for precast concrete connections. The proposed mechanical splice resists external loading immediately after the engagement. The mechanical splices applicable for both large-scale rebars for plants and small-scale rebars for buildings were developed with the same design concept. Quasi-static lateral cyclic loading tests were conducted with reinforced and precast concrete members to verify the seismic performance. Also, shaking table tests with three types of seismic wave excitation, 1) random wave with white noise, 2) the 2016 Gyeongju earthquake, and 3) the 1999 Chi-Chi earthquake, were conducted to confirm the dynamic performance. All tests were performed with real-scale concrete specimens. Sensors measured the lateral load, acceleration, displacement, crack pattern, and secant system stiffness, and energy dissipation was determined by lateral load-displacement relation. As a result, the precast specimen provided the emulative performance with RC. In the shaking table tests, PC frames' maximum acceleration and displacement response were amplified 1.57 - 2.85 and 2.20 - 2.92 times compared to the ground motions. The precast specimens utilizing clamped mechanical splice showed ductile behavior with energy dissipation capacity against strong motion earthquakes.