• 제목/요약/키워드: Seismic load test

검색결과 494건 처리시간 0.022초

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • 해양환경안전학회지
    • /
    • 제26권3호
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

나선철근 원형교각의 연성 및 내진성능 (Ductility and Seismic Performance of Spirally Reinforced Bridge Columns)

  • 이재훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.356-363
    • /
    • 2000
  • The objectives of this study are to investigate seismic performance of spirally reinforced bridge columns and to provide test result for developing improved seismic design criteria. Quasi-static test was conducted for 12 columns of which variables were transverse reinforcement ratio and spacing, longitudinal reinforcement ratio, and axial load level. Sufficient seismic performance was observed from the test for the columns with greater confinement steel amount than the requirement of the Korean Bridge Design Specification. The columns with 0.84% of the confinement steel requirement provided adequate performance under less than 0.2 of axial load level, but showed lower ductility under 0.3 of axial load level. The current provision for the region of confinement steel distribution may be non-conservative under high axial load level, therefore a modified provision is proposed.

  • PDF

Seismic performance assessment of steel reinforced concrete members accounting for double pivot stiffness degradation

  • Juang, Jia-Lin;Hsu, Hsieh-Lung
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.441-455
    • /
    • 2008
  • This paper presents an effective hysteretic model for the prediction and evaluation of steel reinforced concrete member seismic performance. This model adopts the load-deformation relationship acquired from monotonic load tests and incorporates the double-pivot behavior of composite members subjected to cyclic loads. Deterioration in member stiffness was accounted in the analytical model. The composite member performance assessment control parameters were calibrated from the test results. Comparisons between the cyclic load test results and analytical model validated the proposed method's effectiveness.

Seismic behavior of composite walls with encased steel truss

  • Wu, Yun-tian;Kang, Dao-yang;Su, Yi-ting;Yang, Yeong-bin
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.449-472
    • /
    • 2016
  • This paper studies the seismic behavior of reinforced concrete (RC) walls with encased cold-formed and thin-walled (CFTW) steel truss, which can be used as an alternative to the conventional RC walls or steel reinforced concrete (SRC) composite walls for high-rise buildings in high seismic regions. Seven one-fourth scaled RC wall specimens with encased CFTW steel truss were designed, manufactured and tested to failure under reversed cyclic lateral load and constant axial load. The test parameters were the axial load ratio, configuration and volumetric steel ratio of encased web brace. The behaviors of the test specimens, including damage formation, failure mode, hysteretic curves, stiffness degradation, ductility and energy dissipation, were examined. Test results indicate that the encased web braces can effectively improve the ductility and energy dissipation capacity of RC walls. The steel angles are more suitable to be used as the web brace than the latticed batten plates in enhancing the ductility and energy dissipation. Higher axial load ratio is beneficial to lateral load capacity, but can result in reduced ductility and energy dissipation capacity. A volumetric ratio about 0.25% of encased web brace is believed cost-effective in ensuring satisfactory seismic performance of RC walls. The axial load ratio should not exceed the maximum level, about 0.20 for the nominal value or about 0.50 for the design value. Numerical analyses were performed to predict the backbone curves of the specimens and calculation formula from the Chinese Code for Design of Composite Structures was used to predict the maximum lateral load capacity. The comparison shows good agreement between the test and predicted results.

Seismic Performance and Retrofit of Circular Bridge Piers with Spliced Longitudinal Steel

  • Chung, Young-Soo;Lee, Jae-Hyung
    • KCI Concrete Journal
    • /
    • 제14권3호
    • /
    • pp.130-137
    • /
    • 2002
  • It is known that lap splice in the longitudinal reinforcement of reinforced concrete(RC) bridge columns is not desirable for seismic performance, but it is sometimes unavoidable. Lap splices were practically located in the potential plastic hinge region of most bridge columns that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification on 1992. The objective of this research is to evaluate the seismic performance of reinforced concrete(RC) bridge piers with lap splicing of longitudinal reinforcement in the plastic hinge region, to develop the enhancement scheme of their seismic capacity by retrofitting with glassfiber sheets, and to develop appropriate limited ductility design concept in low or moderate seismicity region. Nine test specimens in the aspect ratio of 4 were made with three confinement ratios and three types of lap splice. Quasi-static test was conducted in a displacement-controlled way under three different axial load levels. A significant reduction of displacement ductility ratios was observed for test columns with lap splices of longitudinal steels.

  • PDF

콘크리트 충전 강교각의 내진 성능 (The Seismic Performance for Concrete-filled Steel Piers)

  • 정지만;장승필;인성빈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.189-196
    • /
    • 2002
  • The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

  • PDF

수치해석을 통한 지진하중의 주기특성에 따른 그라운드 앵커의 거동 (Behaviour of Ground Anchor According to Period Characteristic of Seismic Load Using Numerical Analysis)

  • 오동욱;정혁상;윤환희;이용주
    • 터널과지하공간
    • /
    • 제28권6호
    • /
    • pp.635-650
    • /
    • 2018
  • 최근 국내에 발생된 지진으로 인해 더 이상 한반도가 지진으로부터 안전지대가 아니라는 것이 많은 사람들에게 각인되었다. 경주와 포항에서 발생된 지진은 그 동안 국내에서 내진설계에 기준으로 고려한 지진의 특성과 상이하게 나타났고, 그에 따른 내진설계 방법에 대한 연구 또한 많은 연구자들에 의해 수행되어 지고 있다. 이러한 지진하중에 대한 고려는 주로 기존 상부 구조물에 초점이 맞춰져 있으며, 그에 따른 연구 또한 활발히 이루어지고 있는 실정이다. 하지만, 지반의 구조적 안정성을 확보하기 위해 시공된 네일, 록볼트, 그라운드 앵커 등과 같은 지중구조물에 대한 지진하중으로부터의 구조적 안정성에 대한 고려는 많이 이루어지지 않고 있는 실정이다. 본 연구에서는 풍화암에 정착된 그라운드 앵커에 대해 정하중이 작용할 때와 지진하중이 앵커에 미치는 영향을 분석하였다. 정하중에 의한 영향은 현장 인장시험 결과로, 지진하중 영향은 수치해석을 통해 파악하였다. 그 결과, 앵커에 긴장력 도입으로 인한 반력판의 침하가 발생하는 것으로 나타났으며, 그로 인한 앵커의 축력 감소가 발생하였다. 또한 지진하중에 의해 앵커 정착부의 변위가 증가하였으며, 정착부 길이가 길수록 장주기 지진에 의한 영향이 큰 것으로 나타났다.

하중속도가 강구조 보-기둥 접합부 내진성능에 미치는 영향 (Effect of Load Velocity on Seismic Performance of Steel Beam-column Connection)

  • 이기원;오상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.182-192
    • /
    • 2022
  • 취성파괴는 구조물의 파괴거동 중 하나로서 구조재료의 내진성능에 큰 영향을 미친다. 하중속도는 취성파괴의 주요 발생원인 중 하나로 작용하며, 특히 지진과 같은 상황에서 건축물에 높은 하중속도가 작용하게 된다. 하지만 현재 국내·외 강구조 보-기둥 접합부의 내진성능평가는 대부분 정적실험을 통해 수행되고 있다. 따라서 기존 내진성능평가에서는 지진 시의 높은 하중속도에 의한 재료 인성 저하 및 최대변형률 감소 등의 요소에 따른 취성파괴가 충분히 고려되지 않았을 가능성이 존재한다. 본 연구에서는 기존 실험방법에 따른 낮은 하중속도에서의 정적실험과 진동대를 이용한 높은 하중속도에서의 동적실험을 각각 실시한다. 각 실험결과에 따른 파괴형상 및 구조성능 등을 비교·분석하고 최종적으로 하중속도의 크기가 접합부의 내진성능에 미치는 영향을 분석한다.

스테인레스 스틸 와이어 메쉬 보강에 따른 교각의 연성능력 평가 (Evaluation of Ductility for Bridge Piers Retrofitted by Stainless Steel Wire Mesh)

  • 김성훈;김대곤;이규남;김선호;김석희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.879-884
    • /
    • 2002
  • The objective of this study is to investigate the seismic capacity of the non-seismically detailed RC bridge piers before and after applying a seismic retrofitting method using stainless steel wire mesh. Total nine circular section RC piers were constructed. Different lap splice longitudinal reinforcement details were adapted for four specimens and various types of stainless steel wire mesh were applied for the remaining five specimens. Harmonic cyclic lateral load was applied on each specimen under a constant axial load. The test results indicated that the existing circular piers have low seismic capacity while the stainless steel wire mesh retrofitting method improves the seismic capacity considerably. In addition, test results revealed that the circular section piers could have a considerable amount of ductility if longitudinal bars are not lap-spliced in potential plastic hinge zone. Based on this experimental study it could be concluded that the seismic performance, that is ductility and energy absorption capacity, of the non-seismically detailed RC bridge piers would be increased by applying the stainless steel wire mesh seismic retrofitting method.

  • PDF

나선철근교각의 내진성능에 관한 연구 (A Study on Seismic Performance of Spiral Prer)

  • 배성용;김광수;이형준;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.363-368
    • /
    • 2000
  • The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. However, The current seismic design requirements for bridges are based on the USA seismic codes for sever earthquake. This provides the basic factors that affects the performance of spiral reinforced concrete piers for seismic loading, and The specimen tests are performed based on load-displacement, effective stiffness and displacement ductility, etc. The quasi-static test was adopted in order to investigate seismic performance of the spiral reinforced concrete pier specimens which had different transverse steel amount, spacing and longitudinal steel ratio under different axial load levels. This study is concluded that seismic design for transverse reinforcement content of spiral reinforced concrete column has influenced on axial load and effective stiffness etc.

  • PDF