• 제목/요약/키워드: Seismic code

검색결과 676건 처리시간 0.023초

Seismic Behavior of Liquid Storage Tanks Using Complex and Simple Analytical Models

  • Nabin, Raj Chaulagain;Sun, Chang Ho;Kim, Ick Hyun
    • 한국지진공학회논문집
    • /
    • 제22권7호
    • /
    • pp.401-409
    • /
    • 2018
  • Performance-based seismic evaluation is usually done by considering simplified models for the liquid storage tanks therefore, it is important to validate those simplified models before conducting such evaluation. The purpose of this study is to compare the seismic response results of the FSI (fluid-structure interaction) model and the simplified models for the cylindrical liquid storage tanks and to verify the applicability of the simplified models for estimating failure probability. Seismic analyses were carried out for two types of storage tanks with different aspect ratios (H/D) of 0.45 and 0.86. FSI model represents detailed 3D fluid-structure interaction model and simplified models are modeled as cantilever mass-spring model, frame type mass-spring model and shell type mass-spring model, considering impulsive and convective components. Seismic analyses were performed with modal analysis followed by time history analysis. Analysis results from all the models were verified by comparing with the results calculated by the code and literature. The results from simplified models show good agreement with the ones from detailed FSI model and calculated results from code and literature, confirming that all three types of simplified models are very valid for conducting failure probability analysis of the cylindrical liquid storage tanks.

Seismic performance of RC frame having low strength concrete: Experimental and numerical studies

  • Rizwan, Muhammad;Ahmad, Naveed;Khan, Akhtar Naeem
    • Earthquakes and Structures
    • /
    • 제17권1호
    • /
    • pp.75-89
    • /
    • 2019
  • The paper presents experimental and numerical studies carried out on low-rise RC frames, typically found in developing countries. Shake table tests were conducted on 1:3 reduced scaled two-story RC frames that included a code conforming SMRF model and another non-compliant model. The later was similar to the code conforming model, except, it was prepared in concrete having strength 33% lower than the design specified, which is commonly found in the region. The models were tested on shake table, through multiple excitations, using acceleration time history of 1994 Northridge earthquake, which was linearly scaled for multi-levels excitations in order to study the structures' damage mechanism and measure the structural response. A representative numerical model was prepared in finite element based program SeismoStruct, simulating the observed local damage mechanisms (bar-slip and joint shear hinging), for seismic analysis of RC frames having weaker beam-column joints. A suite of spectrum compatible acceleration records was obtained from PEER for incremental dynamic analysis of considered RC frames. The seismic performance of considered RC frames was quantified in terms of seismic response parameters (seismic response modification, overstrength and displacement amplification factors), for critical comparison.

The questionable effectiveness of code accidental eccentricity

  • Ouazir, Abderrahmane;Hadjadj, Asma;Gasmi, Hatem;Karoui, Hatem
    • Structural Engineering and Mechanics
    • /
    • 제83권1호
    • /
    • pp.45-51
    • /
    • 2022
  • The need to account for accidental torsion in seismic design is no longer debatable, however, the seismic codes' requirement for accidental eccentricity has recently faced criticism. In order to get as close to real conditions as possible, this study investigated the impact of accidental torsion in symmetric RC multistory buildings caused by one of its many sources, the torsional earthquake component, and compared the results to those obtained by using the accidental eccentricity recommended by the codes (shifting the center of mass). To cover a wide range of frequencies and site conditions, two types of torsion seismic components were used: a recorded torsion accelerogram and five others generated using translation accelerograms. The main parameters that govern seismic responses, such as the number of stories (to account for the influence of all modes of vibration) and the frequency ratio (Ω) variation, were studied in terms of inter-story drift and displacement responses, as well as torsional moment. The results show that the eccentricity ratio of 5% required by most codes for accidental torsion should be reexamined and that it is prudent for computer analysis to use the static moment approach to implement the accidental eccentricity while waiting for new seismic code recommendations on the subject.

Influence of high axial compression ratios in RC columns on the seismic response of MRF buildings

  • Sergio Villar-Salinas;Sebastian Pacheco;Julian Carrillo;Francisco Lopez-Almansa
    • Structural Engineering and Mechanics
    • /
    • 제90권1호
    • /
    • pp.51-70
    • /
    • 2024
  • Poorly designed reinforced concrete (RC) columns of actual moment-resisting frame (MRF) buildings can undergo Axial Compression Ratios (ACR) so high as their demand exceeds their capacity, even for serviceability gravity load combinations, this lack commonly leads to insufficient seismic strength. Nonetheless, many seismic design codes do not specify limits for ACR. The main contribution of this research is to investigate the need to limit the ACR in seismic design. For this purpose, three prototype 6 and 11-story RC MRF buildings are analyzed in this paper, these buildings have columns undergoing excessive ACR, according to the limits prescribed by standards. To better that situation, three types of alterations are performed: retrofitting the abovementioned overloaded columns by steel jacketing, increasing the concrete strength, and reducing the number of stories. Several finite element analyses are conducted using the well-known software SAP2000 and the results are used for further calculations. Code-type and pushover analyses are performed on the original and retrofitted buildings, the suitability of the other modified buildings is checked by code-type analyses only. The obtained results suggest that ACR is a rather reliable indicator of the final building strength, hence, apparently, limiting the ACR in the standards (for early stages of design) might avoid unnecessary verifications.

Seismic collapse probability of eccentrically braced steel frames

  • Qi, Yongsheng;Li, Weiqing;Feng, Ningning
    • Steel and Composite Structures
    • /
    • 제24권1호
    • /
    • pp.37-52
    • /
    • 2017
  • To quantitatively assess the safety against seismic collapse of eccentrically braced steel frame (EBSF) system, 24 typical EBSFs with K-shape and V-shape braces with seismic precautionary intensities 8 and 9 were designed complying with China seismic design code and relative codes to constitute archetype space of this structure system. In the archetype space, the collapse probability of the structural system under maximum considered earthquakes (MCE) was researched. The results show that the structures possess necessary safety against seismic collapse when they respectively encounter the maximum considered earthquakes corresponding to their seismic precautionary levels, and their collapse probabilities increase with increasing seismic precautionary intensities. Moreover, the EBSFs with V-shape braces have smaller collapse probability, thus greater capacity against seismic collapse than those with K-shape braces.

Development of the Damping Coefficients for Weak and Moderate Earthquake Ground Motions

  • Kim, Myeong-Han
    • 한국방재학회 논문집
    • /
    • 제8권5호
    • /
    • pp.1-6
    • /
    • 2008
  • 대부분의 내진설계기준에서는 설계지반운동을 정의하기 위해서 설계스펙트럼을 제시하고 있다. 기준에서 제시되는 설계스펙트럼은 일반적으로 5% 임계감쇠비에 대한 것이며, 이것은 일반적인 건축구조물에 적용할 수 있는 것이다. 에너지 소산장치나 면진 시스템의 적용이 점차 증가하고 있으며, 이러한 장치를 적용한 건축구조물의 내진해석을 위해서는 5% 임계감쇠비를 초과하는 설계스펙트럼이 필요하다. 5% 임계감쇠비에 대한 설계스펙트럼을 다른 임계감쇠비에 대한 설계스펙트럼으로 변환하기 위해서는 감쇠계수가 효과적으로 이용될 수 있다. 현재의 내진설계기준에서 제시하고 있는 감쇠계수는 강진자료를 바탕으로 제시된 것이다. 중진 및 약진은 강진과는 다른 특성을 가지므로, 이러한 감쇠계수가 중진 및 약진 지역에 적용하는 것은 충분한 검토가 필요할 것이다. 이 논문에서는 중진 및 약진자료를 이용한 감쇠계수를 제시하고, 현재 설계기준에서 제시하고 있는 감쇠계수와 비교하였다.

현행 내진 설계규준(UBC)으로 설계된 구조물의 내진 신뢰성 평가 (Evaluation of seismic reliability of structures designed accoring to current seismic design provision (UBC))

  • 한상환;이리형
    • 전산구조공학
    • /
    • 제8권3호
    • /
    • pp.113-122
    • /
    • 1995
  • 이 논문의 목적은 현행법규(Uniform Buidling Code, NEHRP 설계규준 등)에 따라 설계된 구조들의 성능 및 안정성을 평가하는데 있다. 구조물의 내진성능은 신뢰성으로 표현할 수 있다. 구조물의 그의 수명동안 내진에 대한 신뢰성 해석을 하기 위해서는 주어진 구조물들의 많은 양의 동적반응 해석을 요구하는 것이 일반적이다 따라서 구조물의 신뢰성 해석을 위하여 구조물이 위치한 지역에 많은 양의 지진기록들이 요구된다. 이 논문에서는 인위적인 지진들(artificial earthquakes)을 부정착 임계 파정법(nonstationary randon process)을 이용해 만들었고 구조물은 Uniform Building Code와 AISC 허용응력 설계지침서(AISC allowables stress design manual)에 따라서 설계하였다. 이 논문에서는 주어진 지진하중에 대한 구조물의 반응은 구조물의 비선형 반응해석과 반응변위수정계수들을 이용한 간략화된 동위 구조물 해석(ENS)으로 얻었다. 이 논문에서는 구조물의 내진성능을 평가하였다. 또한 동위구조물(Equivalent Nonlinear System (ENS))을 이용한 해석과 구조물의 비선형 반응해석의 결과들을 비교하여 동위구조물을 이용한 방법의 정확성도 령가하였다.

  • PDF

특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가 (Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details)

  • 김선훈;이득행;김용겸;이상원;여운용;박정은
    • 한국지진공학회논문집
    • /
    • 제27권5호
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

Vulnerability assessment and retrofit solutions of precast industrial structures

  • Belleri, Andrea;Torquati, Mauro;Riva, Paolo;Nascimbene, Roberto
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.801-820
    • /
    • 2015
  • The seismic sequence which hit the Northern Italian territory in 2012 produced extensive damage to reinforced concrete (RC) precast buildings typically adopted as industrial facilities. The considered damaged buildings are constituted by one-storey precast structures with RC columns connected to the ground by means of isolated socket foundations. The roof structural layout is composed of pre-stressed RC beams supporting pre-stressed RC floor elements, both designed as simply supported beams. The observed damage pattern, already highlighted in previous earthquakes, is mainly related to insufficient connection strength and ductility or to the absence of mechanical devices, being the connections designed neglecting seismic loads or neglecting displacement and rotation compatibility between adjacent elements. Following the vulnerabilities emerged in past seismic events, the paper investigates the seismic performance of industrial facilities typical of the Italian territory. The European building code seismic assessment methodologies are presented and discussed, as well as the retrofit interventions required to achieve an appropriate level of seismic capacity. The assessment procedure and retrofit solutions are applied to a selected case study.

보라매 대교빌딩 리모델링을 위한 지진응답 저감기술 적용사례 (Application of the Seismic Response Reduction Technology for Boramae Deokyo Building Remodeling)

  • 박영미;박기홍;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.134-136
    • /
    • 2013
  • In general, the seismic retrofit is almost essential to extend and remodel aged buildings. Because domestic seismic design code has been enhanced, seismic performance should be secure for aged building remodeling. Seismic response reduction device (damper) is lately appling to ensure seismic performance. This device is economical efficiency method that can reduce the load to foundation and the range of structural reinforcements, shorten of construction period. New shaped steel damper was applied for extension and remodeling construction for Boramae Deakyo building. As a result, the economy and shortening of construction period was achieved.

  • PDF