• 제목/요약/키워드: Seismic Waves

검색결과 381건 처리시간 0.027초

Harmonic seismic waves response of 3D rigid surface foundation on layer soil

  • Messioud, Salah;Sbartai, Badredine;Dias, Daniel
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.109-118
    • /
    • 2019
  • This study, analyses the seismic response for a rigid massless square foundation resting on a viscoelastic soil layer limited by rigid bedrock. The foundation is subjected either to externally applied forces or to obliquely incident seismic body or surface harmonic seismic waves P, SV and SH. A 3-D frequency domain BEM formulation in conjunction with the thin layer method (TLM) is adapted here for the solution of elastodynamic problems and used for obtained the seismic response. The mathematical approach is based on the method of integral equations in the frequency domain using the formalism of Green's functions (Kausel and Peck 1982) for layered soil, the impedance functions are calculated by the compatibility condition. In this study, The key step is the characterization of the soil-foundation interaction with the input motion matrix. For each frequency the impedance matrix connects the applied forces to the resulting displacement, and the input motion matrix connects the displacement vector of the foundation to amplitudes of the free field motion. This approach has been applied to analyze the effect of soil-structure interaction on the seismic response of the foundation resting on a viscoelastic soil layer limited by rigid bedrock.

ARTICLES : MULTICHANNEL ANALYSIS OF SURFACE WAVES (MASW) - AN OVERVIEW

  • ChoonB.Park
    • 지구물리
    • /
    • 제6권2호
    • /
    • pp.99-105
    • /
    • 2003
  • Rayleigh waves which has more than 70% of the total seismic energy is the principal component of ground roll. Frequency component of a surface wave has a different propagation velocity, that is, phase velocity, which results in a different wavelength called dispersion. Rayleigh wave is one of the most common ways to use the dispersive properties of surface waves. MASW is a seismic method to evaluate shear-wave velocity information of the ground.

  • PDF

지진파를 이용한 지하 공동의 탐지 방법 (Possible Methods of Identifying Underground Cavities Using Seismic Waves)

  • 김소구;마상윤;김지수
    • 지질공학
    • /
    • 제6권3호
    • /
    • pp.137-153
    • /
    • 1996
  • 본 연구는 이미 알려져 있는 공동 지역에서 1년 6개월에 걸친 고정점 관측 및 이동 관측망에 의한 실험을 통하여 지하 매질에 공동이 존재할 때에 나타나는 지진파의 이상 현상에 의하여 지하에 존재하는 공동을 탐지 및 식별할 수 있는 가능성을 찾는데 그 목적이 있다. 한양 대학교 지진 연구소에서는 경기도 화성군 봉담면에 위치한 삼보 광산에서 고정 지진 관측을 수행하였다. 이 자료의 대부분은 인근 골재 채취장에서의 화약류 발파에 의한 것이며 본 연구에서는 이 화약류 발파에 의한 자료를 이용하였다. 고정 관측소 관측의 경우 지상 관측과 삼보 광산의 갱도 안에서의 지하 관측을 수행하였다. 이 두 자료으 경우 종파의 초동 후 150 ~ 250 msec 후에 전환파(converted phase)의 출현에 의하여 편파 특성이 매우 급격하게 변하는 양상을 보여 준다. 전환파가 발생하는 깊이는 평균 약 190m 정도로서 삼보 광산의 갱도 깊이와 잘 일치되는 결과를 보여 준다. 또한 횡파 분열(Shear-wave Splitting) 현상이 관측되었다. 빠른 횡파(fS)와 느린횡파(sS)의 시간 차이는 약 30-60ms 정도의 차이(평균 42 ms)를 보인다. 이러한 결과는 다른 연구의 결과보다는 상당히 큰 값을 보여 주는데 이는 지하 공동에 의한 균열(Crack)이 상당히 발달해 있는 것을 나타내는 결과이다. 또한 화약 발파 실험에 의한 자료는 공동에 설칠한 지진계와 비공동 지역에 설피한 지진계를 비교 분석하였다. 공동 지역에서 설치한 지진계의 경우 고정 관측소의 경우와 같이 종파의 초동후에 편파 특성이 매우 급격하게 변하는 양상을 보이나 비공동 지역에 설치한 지진계의 경우는 편파 특성이 매우 안정적인 양상을 보인다. 또한 공동 지역을 지난 지진파의 특징은 현저한 고주파수 성분의 감쇄와 탁월한 저주파의 성질을 갖는 위상이 관측되었다.

  • PDF

테프론형 기초지진격리장치의 성능평가 (Evaluation of Performance of the Teflon-Type Seismic Foundation Isolation System)

  • 손수원;김응수;나건하;김진만
    • 한국지진공학회논문집
    • /
    • 제21권3호
    • /
    • pp.125-135
    • /
    • 2017
  • Various seismic isolation methods are being applied to bridges and buildings to improve their seismic performance. Most seismic isolation systems are the structural seismic isolation systems. In this study, the seismic performance of geotechnical seismic isolation system capable of isolating the lower foundation of the bridge structure from ground was evaluated. The geotechnical seismic isolation system was built with teflon, and the model structure was made by adopting the similitude law. The response acceleration for sinusoidal waves of various amplitudes and frequencies and seismic waves were analyzed by performing 1-G shaking table experiments. Fixed foundation, Sliding foundation, and Rocking foundation were evaluated. The results of this study indicated that the Teflon-type seismic foundation isolation system is effective in reducing the acceleration transmitted to the superstructure subject to large input ground motion. Response spectrum of the Rocking and Sliding foundation structures moves to the long period, while that of Fixed foundation moves to short period.

Seismic surface waves in a pre-stressed imperfectly bonded covered half-space

  • Negin, Masoud
    • Geomechanics and Engineering
    • /
    • 제16권1호
    • /
    • pp.11-19
    • /
    • 2018
  • Propagation of the generalized Rayleigh waves in an elastic half-space covered by an elastic layer for different initial stress combinations and imperfect contact conditions is investigated. Three-dimensional linearized theory of elastic waves in initially stressed bodies in plane-strain state is employed, the corresponding dispersion equation is derived and an algorithm is developed for numerical solution to this equation. Numerical results on the influence of the initial stress patterns and on the influence of the contact conditions are presented and discussed. The case where the external forces are "follower forces" is considered as well. These investigations provide some theoretical foundations for the study of the near-surface waves propagating in layered mechanical systems and can be successfully used for estimation of the degree of the bonded defects between layers, fault characteristics and study of the behavior of seismic surface waves propagating under the bottom of the oceans.

내진 설계용 스펙트럼에 적합한 인공지진파의 작성과 응답 특성 (Simulation of Artificial Earthquake Wave Compatible with Seismic Design Spectrum and Its Response Characteristics)

  • 전대한;강병두;김재웅
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.141-148
    • /
    • 2006
  • This study describes a generation of artificial earthquake wane compatible with seismic design spectrum. In seismic response analysis of building structures, the input ground accelerations have considerable effect on dynamic characteristics of structures. Therefore, it is important to properly select input ground motions for seismic response analysis. In this paper, the artificial earthquake wave are generated according to previously recorded earthquake waves in past earthquake events. The artificial wave have identical phase angles to the recorded earthquake wane, and their overall response spectra are compatible with seismic design spectrum with 5% of critical viscous damping. Each simulated earthquake wave has a identical phase angles to the original recorded ground acceleration, and match to design response spectra in the range of period from 0.02 to 10.0 seconds. It is concluded that the artificial earthquake waves simulated in this paper ate applicable as input ground motions for a seismic response analysis of building structures.

  • PDF

Wave shape analysis of seismic records at borehole of TTRH02 and IWTH25 (KiK-net)

  • Kamagata, Shuichi
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.297-312
    • /
    • 2020
  • The KiK-net by NIED is a vertical array measurement system. In the database of KiK-net, singular pulse waves were observed in the seismic record at the borehole of TTRH02 during the mainshock (the magnitude of Japan Meteorological Agency (MJ) 7.3, MW 6.8) and aftershock (Mj 4.2) of Tottori-ken Seibu earthquake in 2000. Singular pulse waves were also detected in the seismic records at the borehole of IWTH25 during the Iwate-Miyagi Nairiku earthquake in 2008 (MJ 7.2, MW 6.9). These pulse waves are investigated by using the wave shape analysis methods, e.g., the non-stationary Fourier spectra and the double integrated displacement profiles. Two types of vibration modes are discriminated as the occurrence mechanism of the singular pulse waves. One corresponds to the reversal points in the displacement profile with the amplitude from 10-4 m to 10-1 m, which is mainly related to the fault activity and the amplification pass including the mechanical amplification (collision) of the seismograph in the casing pipe. The other is the cyclic pulse waves in the interval of reversal points, which is estimated as the backlash of the seismograph itself with the amplitude from 10-5 m to 10-4 m.

Seismic responses of a metro tunnel in a ground fissure site

  • Liu, Nina;Huang, Qiang-Bing;Fan, Wen;Ma, Yu-Jie;Peng, Jian-Bing
    • Geomechanics and Engineering
    • /
    • 제15권2호
    • /
    • pp.775-781
    • /
    • 2018
  • Shake table tests were conducted on scaled tunnel model to investigate the mechanism and effect of seismic loadings on horseshoe scaled tunnel model in ground fissure site. Key technical details of the experimental test were set up, including similarity relations, boundary conditions, sensor layout, modelling methods were presented. Synthetic waves and El Centro waves were adopted as the input earthquake waves. Results measured from hanging wall and foot wall were compared and analyzed. It is found that the seismic loadings increased the subsidence of hanging wall and lead to the appearance and propagation of cracks. The values of acceleration, earth pressure and strain were greater in the hanging wall than those in the foot wall. The tunnel exhibited the greatest earth pressure on right and left arches, however, the earth pressure on the crown of arch is the second largest and the inverted arch has the least earth pressure in the same tunnel section. Therefore, the effect of the hanging wall on the seismic performance of metro tunnel in earth fissure ground should be considered in the seismic design.

천부 탄성파 벡터자료 획득 및 분석 (Acquisition and Processing of Shallow Vector Seismic Data)

  • 홍명호;김기영;황윤구
    • 지구물리
    • /
    • 제8권2호
    • /
    • pp.81-87
    • /
    • 2005
  • P, SH, SV 파를 동시에 발생시킬 수 있는 타격방법을 고안하여 3성분 지오폰으로 수신함으로써, 발생된 탄성파를 벡터형태로 획득하고 분석하는 연구를 수행하였다. 시험자료로는 94 m의 측선을 따라 2 m 간격으로 설치한 수신점에서 0.5 ms 간격으로 512 ms 동안 기록한 24채널 자료를 사용하였다. 획득한 시험자료의 수직성분에는 굴절 및 반사된 P파가 뚜렷하게 기록되어 있으며, 측선에 수직한 수평성분에는 SH파, 측선에 평행한 수평성분에는 직접 P파와 PS 변환파가 비교적 강하게 기록되었다. 동시에 획득한 수직 및 측선에 수직한 수평성분에 각각 기록된 P파 및 SH파 초동을 굴절파 토모그래피 방식으로 역산한 결과, P파 및 S파 속도 토모그램을 얻을 수 있었으며, 이 두 속도단면으로부터 동포아송비 값을 효과적으로 구할 수 있었다.

  • PDF

SSI해석을 통한 압축전담 교량 내진보강공법 거동 특성 연구 (Behavior Characteristics of Compression-Only Bridge Seismic Reinforcement Method Using SSI Analysis)

  • 장유식;윤원섭;유광호
    • 한국산업융합학회 논문집
    • /
    • 제25권6_3호
    • /
    • pp.1231-1238
    • /
    • 2022
  • In this study, the reinforcement effect of the compression-only bridge seismic reinforcement method, which is mainly applied to old bridges, was studied through SSI analysis. As the analysis conditions, acceleration magnitudes of 0.1g, 0.15g, and 0.2 g were applied, and long-period and short-period seismic waves were applied. As a result of the analysis according to the assumed ground characteristics and structure size, the horizontal displacement at the reinforced section was reduced by about 9%, and the long-period seismic wave had a 95% larger displacement than the short-period seismic wave. In addition, an increase in acceleration of 0.1g resulted in a displacement of about 50%, and a large increase in displacement was observed in long-period seismic waves. As a result of the analysis, in the case of the compression-only bridge seismic reinforcement method, there was a reinforcing effect, so the field applicability was excellent.