• 제목/요약/키워드: Seismic Retrofit

검색결과 389건 처리시간 0.035초

Experimental investigation of a frame retrofitted with carbon textile reinforced mortar

  • Sinan M., Cansunar;Kadir, Guler
    • Earthquakes and Structures
    • /
    • 제23권5호
    • /
    • pp.473-491
    • /
    • 2022
  • The research investigates experimentally the effect of confinement on structural behavior at the ends of beam-column in reinforced concrete (RC) frames. In the experimental study, five specimens consisting of 1/3-scaled RC frames having single-bay, representing the traditional deficiencies of existing buildings constructed without receiving proper engineering service is investigated. The RC frame specimens were produced to represent most of the existing buildings in Turkey that have damage potential. To decrease the probable damage to the existing buildings exposed to earthquakes, the carbon Textile Reinforced Mortar (TRM) strengthening technique (fully wrapping) was used on the ends of the RC frame elements to increase the energy dissipation and deformation capacity. The specimens were tested under reversed cyclic lateral loading with constant axial loads. They were constructed satisfying the weak column-strong beam condition and consisting of low-strength concrete, such as compressive strength of 15 MPa. The test results were compared and evaluated considering stiffness, strength, energy dissipation capacity, structural damping, ductility, and damage propagation in detail. Comprehensive investigations of these experimental results reveal that the strengthening of a brittle frame with fully-TRM wrapping with non-anchored was effective in increasing the stiffness, ductility, and energy dissipation capacities of RC bare frames. It was also observed that the frame-only-retrofitting with an infill wall is not enough to increase the ductility capacity. In this case, both the frame and infill wall must be retrofitted with TRM composite to increase the stiffness, lateral load carrying, ductility and energy dissipation capacities of RC frames. The presented strengthening method can be an alternative strengthening technique to enhance the seismic performance of existing or moderately damaged RC buildings.

UBCSAND모델을 이용한 사면의 동적거동해석 (Numerical Modeling of Sloping Ground under Earthquake Loading Using UBCSAND Model)

  • 박성식;김영수;김희중
    • 한국지반공학회논문집
    • /
    • 제22권4호
    • /
    • pp.61-71
    • /
    • 2006
  • 본 논문에서는 유효응력모델을 이용하여 포화된 사면의 동적거동에 관한 연구를 수행하였다. 수치해석에는 저자가 개발한 연성 유효응력모델인 UBSSAND모델을 이용하였으며, 이 모델은 초기전단응력이 수평면에 작용하는 경우와 작용하지 않는 경우를 포함한 반복 직접단순전단시험 자료를 이용하여 검증하였다. 검증된 모델은 느슨한 Fraser River 모래로 성형된 사면을 가진 원심모형모델의 동적거동을 예측하였다. 예측된 과잉간극수압, 가속도 및 변위를 계측치와 서로 비교하였으며, 예측치와 계측치는 비교적 서로 잘 일치하였다. 전단응력도의 응력전환형태는 초기전단응력과 반복전단응력의 크기에 따라 달라지며, 이는 지진시 포화된 사면의 안정해석에 아주 중요한 역할을 하고 있음을 알 수 있었다. 전단응력도의 응력전환이 발생하지 않을 경우에 사면근처의 모래는 낮은 유효응력 구속압과 그에 따른 팽창성으로(부의 과잉간극수압발생) 유효응력이 증가하여, 동적하중 하의 사면의 변위를 저지하였다. 이와 같은 유효응력모델은 액상화를 고려한 지반구조물의 내진해석에 유용하게 사용될 수 있다.

탄소섬유시트로 구속된 원형 RC기둥의 일축압축 거동 (Uniaxial Compression Behavior of Circular RC Columns Confined by Carbon Fiber Sheet Wraps)

  • 한상훈;홍기남
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.125-133
    • /
    • 2007
  • CFS로 둘러싸서 외부에서 구속하는 방법은 정적 혹은 지진하중을 받는 철근콘크리트 기둥을 보강하는데 매우 효과적이다. 이러한 CFS 보강법의 신뢰성 있고 경제적인 설계를 위해서는 정확한 CFS 구속콘크리트의 응력-변형률 관계를 파악하는 것이 필요하게 된다. 본 연구에서는 원형단면을 갖는 단주 RC 기둥에 대해서 일축압축 실험을 실시하였다. CFS 면적비, 나선철근 면적비, 그리고 콘크리트 압축강도가 CFS로 구속된 콘크리트의 응력-변형률관계에 대한 영향을 평가하기 위한 실험변수로서 고려되었다. 기둥을 CFS로 횡보강함으로서 콘크리트의 강도 및 연성이 크게 증가되었다. 또한, 나선철근이 배근된 실험체의 강도증가율은 CFS만으로 횡보강된 실험체보다 횡보강성능이 크고 작게 나타났다.

반복하중하의 FRP 시트 종류에 따른 부착특성 (Bond Characteristics of FRP sheet to Various Types under Cyclic Load)

  • 고훈범
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권2호
    • /
    • pp.131-138
    • /
    • 2008
  • 최근 지진, 노후화 등에 따라 손상된 많은 콘크리트 구조물을 보강하기 위하여 고강도이면서 가볍고 내구성이 뛰어난 특성을 가지고 있는 FRP(Fiber-reinforced polymer) 시트가 구미에서 뿐만 아니라 우리나라에서도 널리 사용되고 있으며 관련연구도 활발히 체계적으로 이루어지고 있다. 일반적으로 FRP 시트로 보강된 RC구조물은 지진, 교통, 온도 등에 의해 자주 반복하중을 받는다. 그러나 대부분의 연구가 일축 하중하에 이루어진 경우가 대부분이며 이러한 연구결과를 토대로 FRP의 부착특성을 확인하고 있으며 다양한 부착모델을 제안하고 있다. 이러한 관점에서 본 연구에서는 아라미드섬유, 탄소섬유, 폴리아세탈 섬유와 매수를 변수로 하여 총 18개의 시험체를 제작하고 최대부착강도, 최대변위, 변형률을 측정하고 그 결과에 근거하여 부착응력, 슬립을 계산하여 반복하중하의 FRP 시트와 콘크리트의 부착특성을 미시적으로 살펴보았다.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가 (Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test)

  • 이용훈;김진우;김재환;엄태성;이상현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.182-192
    • /
    • 2023
  • 본 연구에서는 동적 횡하중을 받는 조적 담장의 내진성능 향상을 위한 ECC(Engineered Cementitious Composite) 자켓의 효과를 실험적으로 검증하였다. 첫째로, 임팩트 해머 시험을 통해 비보강과 ECC로 보강된 조적 담장의 고유진동수와 모드 감쇠비, 변형 형상을 식별하여, 940mm의 비보강 조적담장과 970mm의 ECC 보강 담장이 각각 6.4, 35.3Hz의 고유진동수와 7.0, 5.3%의 감쇠비를 가지는 것을 확인하였다. 둘째로, 진동대를 사용하여 면외방향에 대한 지진파 실험을 수행하였고, El Centro(1940) 지진파를 25%부터 300%까지 스케일링하여 적용하였다. 비보강 조적담장의 경우, 50% 지진하중에서 벽돌과 줄눈 경계에 휨균열이 발생하였고, 다시 30%로 스케일링된 지반운동에서 면외방향으로 전도파괴되었다. 반면에 ECC로 보강된 조적담장은 300%의 지진하중에서도 균열이나 손상 없이 강건한 성능을 유지하였다. 마지막으로, 25~300%의 지반운동에 의한 비보강과 ECC 보강 조적담장의 밑면전단력과 설계기준에 따른 밑면전단력을 비교 및 평가하였다. 그 결과, 재현주기 1,000년의 지진에 대해 비보강 조적담장이 붕괴될 위험이 있는 데 반해, ECC 보강 담장은 4,800년 주기의 지진에도 안전한 것으로 추정되었다.

베이지안 네트워크를 이용한 지진 유발 화재・폭발 복합재해 확률론적 안전성 평가 (Bayesian Network-based Probabilistic Safety Assessment for Multi-Hazard of Earthquake-Induced Fire and Explosion)

  • 이세혁;석의찬;송준호
    • 한국전산구조공학회논문집
    • /
    • 제37권3호
    • /
    • pp.205-216
    • /
    • 2024
  • 최근 원자력 지진 PSA(Probabilistic Safety Assessment)를 토대로 산업시설물의 지진 PSA를 수행하는 연구가 진행되었다. 해당 연구는 원자력 발전소와 산업시설물의 차이를 파악하고, 최종적으로 운영정지를 목표로 하는 고장수목(Fault Tree)를 구축한 후 시각적 확률도구인 베이지안 네트워크(Bayesian Network, BN)으로 변환하였다. 본 연구는 선행연구를 기반으로 지진으로 유발된 구조손상으로 인해 발생 가능한 화재・폭발에 대해 PSA를 수행하고자 하였다. 이를 위해 화재・폭발을 사건수목(Event Tree)으로 표현하고, BN으로 변환하였다. 변환된 BN은 화재・폭발 모듈로서 선행연구에서 제시된 고장수목 기반 BN과 연계되어 최종적으로 지진 유발 화재・폭발 PSA를 수행할 수 있는 BN 기반 방법론이 개발되었다. 개발된 BN을 검증하기위해 수치예제로서 가상의 가스플랜트 Plot Plan을 생성하였고, 가스플랜트의 설비 종류가 구체적으로 반영된 대규모 BN을 구축하였다. 해당 BN을 이용하여 지진 규모에 따른 전체시스템의 운영정지 확률 및 하위시스템들의 고장확률 산정과 더불어 역으로 전체시스템이 운영 정지되었을 때 하위시스템들의 영향도 분석과 화재・폭발 가능성을 산정하여 다양한 의사결정을 수행할 수 있음을 제시함으로써 그 우수성을 확인하였다.

외부자켓에 의해 보강된 콘크리트 압축시편의 압축변형률 측정 및 보정 (Measuring and Correcting The Compressive Axial Strain of Concrete Cylinders Retrofitted by External Jackets)

  • 최은수;이영근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권2호통권54호
    • /
    • pp.215-222
    • /
    • 2009
  • 콘크리트 공시편의 외부보강을 위해서 강판과 FRP 자켓을 이용하였다. 기존의 강판 또는 FRP 자켓 보강기법은 보강재와 콘크리트 사이에 접착제를 이용하여 시공하므로 콘크리트와 보강재가 합성거동 하게 된다. 그러나 본 연구에서 사용한 강판 보강기법은 외부압착에 의한 기법으로 강판과 콘크리트가 합성거동을 하지 않는다. 본 연구에서는 비합성거동과 합성거동을 하는 보강된 콘크리트 시편의 압축 변형률의 측정과 이를 보정하는 기법을 제시하였다. 비합성거동의 강판보강 콘크리트 시편의 압축변형률 측정은 강판의 표면에서 변형률을 측정하여 표시할 수 없으며, 시편에 설치하여 측정하는 compressometer를 사용할 수도 없었다. 따라서 시편의 상하단에 두꺼운 판을 설치하여 두 판사이의 변형을 측정한 후. 이를 압축변형률로 변환하였다. 합성 거동을 하는 FRP 보강의 경우는 FRP 튜브 표면에서 측정되는 수직방향의 변형률을 콘크리트의 압축변형률로 사용이 가능하다. 그러나 튜브 표면의 수직변형률은 시편의 부풀음에 의한 인장변형률이 포함되어 있기 때문에 콘크리트의 압축변형률을 추정하기 위해서는 이를 보정하여야 한다. 보정된 압축변형률은 콘크리트 내부에서 측정한 변형률과 기존의 콘크리트 연속체 모델과 비교하였을 때, 만족한 결과를 보였다. 보정 전의 응력-변형률 곡선은 콘크리트의 연성거동 및 에너지 소산능력을 보정 전에 비해 낮게 평가할 위험성이 있다.

U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel)

  • 하수경;손국원;유승룡;주호성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.18-28
    • /
    • 2015
  • 이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는데 있다. 1개의 무 보강 보-기둥 실험체와 U형 PC 패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커 접합부 실험체는 전단 파괴될 것으로 해석되었고 철판 용접 접합부 실험체는 휨 파괴할 것으로 예측되었다. 실험체의 종국 내력은 상부 접합부의 전단 내력과 PC 패널 절곡 부 휨 위험단면에서 휨 내력 중 약한 것으로 결정되었다. 이 실험체에서, 한쪽 RC기둥이 가 하중(미는 실험 하중)을 받아 PC 패널 부재를 밀게 된다면, 다른 쪽 내부 수직부재는 상부 전단 접합부로부터 부 하중(당기는 실험 하중)을 받게 되어있었다. 가 하중을 받는 2개의 부재는 합성 휨 거동이 지배적이므로 합성단면의 휨 내력이 실험체의 최종 내력을 결정하게 되지만, 이 경우 최종 내력에 대하여 상부 전단 접합부 강도의 직접적인 영향은 없다고 볼 수 있다. 그러나 부 하중(당기는 하중)을 받는 RC 기둥과 PC 패널 부재는 비합성 거동이 지배적이고 실험체의 최종 내력은 상부 전단 접합부 전단내력의 크기에서 직접 영향을 받는 것으로 파악되었다. ACI 318M-11 Appendix-D 앵커 전단설계에 기초한 전단내력 그리고 실험에서 얻은 최대하중을 적용하여 마이다스 젠 탄성설계에 의하여 계산한 전단 외력에 대한 비교 해석결과는 실험결과와 일치하는 해석결과를 보여주었다.