• Title/Summary/Keyword: Seismic Margin Assessment(SMA)

Search Result 4, Processing Time 0.02 seconds

Seismic Performance Evaluation Methodology for Nuclear Power Plants (원전 구조물의 내진성능 평가 방법론 고찰)

  • Ann, Hojune;Kim, Yousok;Kong, Jung Sik;Choi, Youngjin;Choi, Se Woon;Lee, Min Seok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.2
    • /
    • pp.32-40
    • /
    • 2018
  • Since 2000, the frequency of earthquakes beyond the 5.0 magnitude quake has been increasing in the Korean peninsula. For instance, the 5.0-magnitude earthquake in Baekryong-do in 2003 has occurred, and recent earthquake with Gyeongju(2016) and Pohang(2017) measured respectively magnitude of 5.2 and 5.8 on the Richter scale. As results, the public concern and anxiety about earthquakes are increasing, and therefore it is necessarily required for social infrastructure to reinforce seismic design and energy production facilities directly related to the national economy and security. This study represents the analysis of seismic performance evaluation methodology such as Seismic Margin Assessment (SMA), Seismic Probabilistic Risk Assessment (SPRA), High Confidence Low Probability Failure (HCLPF) in nuclear power plants in order to develop optimal seismic performance improvement. Current methodologies to evaluate nuclear power plants are also addressed. Through review of the nuclear structure evaluation past and current trend, it contributes to be the basis for the improvement of evaluation techniques on the next generation of nuclear power plants.

The Comparison of Seismic Capacities Of Two Approaches, Probabilistic Approach and Deterministic Approach (확률론적 평가법과 결정론적 평가법에 의한 내진성능비교분석)

  • 송정국;황규호;강선구;서용표;이종림
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.101-109
    • /
    • 2003
  • In evaluating the individual Plant Examination of Seismic Events, two methodologies, Seismic Probabilistic Risk Assessment(SPRA) and Seismic Margin Assessment(SMA) can be used. SPRA is based on the probubilistic approach and SMA is based on the deterministic approach in evaluating seismic capacities. In this paper, by evaluating the seismic capacities of the same component by these two approaches respectively, the correlation of two methodologies can be shown. In addition, the meaning of HCLPF(High Confidence of Low Probability of Failure) values that are inherent in these two methodologies is recognized by the quantitative comparison analysis.

  • PDF

A Study on Review-Level Ground Motion For Seismic Margin Assessment (내진여유도 평가를 위한 부석기준지진동(RLGM) 평가 연구)

  • 연관희;이종림
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.97-104
    • /
    • 2000
  • Evaluating a Review-Level Ground Motion is a key to efficiently perform Seismic Margin Assessment of nuclear power plants whose purpose is to determine a ground motion level for which a plant has high-confidence-of-a-low-probability of seismic-induced core damage and to identify any weaker-link components. In this study a method to obtain RLGMs is reviewed which is recommended by Electric Power Research Institute and implemented to be applied to Limerick site in eastern and central U. S as a case study. This method provides reasonable and site-specific RLGMs as minimum required plant HCLPF for SMA that meet a target mean seismic core-damage frequency based on seismic hazard results and generic values of uncertainty and randomness parameters of the core-damage fragility curves. In addition high-frequency RLGM is justifiably modified to reflect the increased seismic capacity of high-frequency components and spatial variation and incoherence of input ground motion on a basemat of large structures by establishing a method to obtain high0-frequency reduction factors according to EPRI guidelines.

  • PDF

Reevaluation of Seismic Fragility Parameters of Nuclear Power Plant Components Considering Uniform Hazard Spectrum

  • Park, In-Kil;Choun, Young-Sun;Seo, Jeong-Moon;Yun, Kwan-Hee
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.586-595
    • /
    • 2002
  • The Seismic probabilistic risk assessment (SPRA) or seismic margin assessment (SMA) have been used for the seismic safety evaluation of nuclear power plant structures and equipments. For the SPRA or SMA, the reference response spectrum should be defined. The site-specific median spectrum has been generally used for the seismic fragility analysis of structures and equipments in a Korean nuclear power plant Since the site-specific spectrum has been developed based on the peak ground motion parameter, the site-specific response spectrum does not represent the same probability of exceedance over the entire frequency range of interest. The uniform hazard spectrum is more appropriate to be used in seismic probabilistic risk assessment than the site- specific spectrum. A method for modifying the seismic fragility parameters that are calculated based on the site-specific median spectrum is described. This simple method was developed to incorporate the effects of the uniform hazard spectrum. The seismic fragility parameters of typical NPP components are modified using the uniform hazard spectrum. The modification factor is used to modify the original fragility parameters. An example uniform hazard spectrum is developed using the available seismic hazard data for the Korean nuclear power plant (NPP) site. This uniform hazard spectrum is used for the modification of fragility parameters.