• Title/Summary/Keyword: Segmental arc

Search Result 4, Processing Time 0.023 seconds

Segmental Analysis Trial of Volumetric Modulated Arc Therapy for Quality Assurance of Linear Accelerator

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Huh, Hyun Do;Kim, Seonghoon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.128-138
    • /
    • 2019
  • Purpose: Segmental analysis of volumetric modulated arc therapy (VMAT) is not clinically used for compositional error source evaluation. Instead, dose verification is routinely used for plan-specific quality assurance (QA). While this approach identifies the resultant error, it does not specify which machine parameter was responsible for the error. In this research study, we adopted an approach for the segmental analysis of VMAT as a part of machine QA of linear accelerator (LINAC). Methods: Two portal dose QA plans were generated for VMAT QA: a) for full arc and b) for the arc, which was segmented in 12 subsegments. We investigated the multileaf collimator (MLC) position and dosimetric accuracy in the full and segmented arc delivery schemes. A MATLAB program was used to calculate the MLC position error from the data in the dynalog file. The Gamma passing rate (GPR) and the measured to planned dose difference (DD) in each pixel of the electronic portal imaging device was the measurement for dosimetric accuracy. The eclipse treatment planning system and a MATLAB program were used to calculate the dosimetric accuracy. Results: The maximum root-mean-square error of the MLC positions were <1 mm. The GPR was within the range of 98%-99.7% and was similar in both types of VMAT delivery. In general, the DD was <5 calibration units in both full arcs. A similar DD distribution was found for continuous arc and segmented arcs sums. Exceedingly high DD were not observed in any of the arc segment delivery schemes. The LINAC performance was acceptable regarding the execution of the VMAT QA plan. Conclusions: The segmental analysis proposed in this study is expected to be useful for the prediction of the delivery of the VMAT in relation to the gantry angle. We thus recommend the use of segmental analysis of VMAT as part of the regular QA.

High Speed Segmental Stator Type 4/3 SRM: Design, Analysis, and Experimental Verification

  • Hieu, Pham Trung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1864-1871
    • /
    • 2017
  • This paper presents a design of a 2-phase segmental stator type 4/3 switched reluctance motor (SRM) for air-blower application. The air-blower requires only one direction rotation, high rotor speed without torque dead-zone. In order to satisfy the requirements of the load, the rotor of the 4/3 proposed SRM is designed with wider rotor pole arc and non-uniform air-gap is applied on the rotor shape. With a special rotor structure, the motor generates a wider positive torque region and has no torque dead-zone. The stator of the proposed SRM is constructed with two segmental C-cores, and there are no magnetic connections between 2 C-cores. The flux follows in a short closed loop in each C-core and has no reversal flux in the stator. The static and dynamic characteristics of the proposed motor are analyzed by the finite element method (FEA) and Matlab-Simulink, respectively. In order to verify the design, a prototype of the proposed motor has manufactured for laboratory test. The performance of the proposed motor is verified by the simulation and experimental results.

A design of the PSDG based semantic slicing model for software maintenance (소프트웨어의 유지보수를 위한 PSDG기반 의미분할모형의 설계)

  • Yeo, Ho-Young;Lee, Kee-O;Rhew, Sung-Yul
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.8
    • /
    • pp.2041-2049
    • /
    • 1998
  • This paper suggests a technique for program segmentation and maintenance using PSDG(Post-State Dependency Graph) that improves the quality of a software by identifying and detecting defects in already fixed source code. A program segmentation is performed by utilizing source code analysis which combines the measures of static, dynamic and semantic slicing when we need understandability of defect in programs for corrective maintanence. It provides users with a segmental principle to split a program by tracing state dependency of a source code with the graph, and clustering and highlighting, Through a modeling of the PSDG, elimination of ineffective program deadcode and generalization of related program segments arc possible, Additionally, it can be correlated with other design modeb as STD(State Transition Diagram), also be used as design documents.

  • PDF

Reconstruction of Tibial Defects in Lower Extremity With Various Versions of Vascularized Fibula Transfer (다양한 형태의 생 비골 이식술을 이용한 경골의 재건)

  • Nam, Sang-Hyun;Kim, Bom-Jin;Koh, Sung-Hoon;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.1
    • /
    • pp.17-25
    • /
    • 2006
  • Twelve cases in eleven patients with segmental bone defects were treated with contralateral fibula free flap and ipsilateral island fibula flap in an antegrade, retrograde or bidirectional flow fashion. Five cases were managed with free flaps and seven were with ipsilateral fibula island transfer. Among seven cases, antegrade fashion was three, retrograde was three, and bidirectional was one. All patients were related with open tibial fractures and its sequelae except one who had open foot bone fracture. According to Gustilo's classification, ten patients were type IIIb and one was type IIIc. Basically, antegrade-flow flaps based on the peroneal vessels as in the conventional free flap were used for the proximal or middle one-third tibial defects. On the contrary, retrograde-flow flaps based on the communicating branch between the peroneal and posterior tibial vessels were used for the middle or distal one-third of the tibia. Bidirection-flow flap based on intact peroneal vessels were used for the middle portion of the tibia. The patients who have undergone ipsilateral fibula island flap had one of the following problems: a previously failed free flap, below-knee amputation of the opposite leg because of open tibial fracture, refusal to use the contralateral sound leg, or poor general condition to stand a lengthy operation. Six of the patients who have got ipsilateral fibula island flap also had an associated fibula fracture on the same leg, which was ultimately used as one of the osteotomy sites. The follow-up period was from 1 to 10 years. Two cases of free flap were failed: one patient had below-knee amputation and the other patient had ipsilateral fibula transfer. Other cases were successful and excellent hypertophy of the transferred fibula was achieved. Time to bone union ranged from 4 to 11 months. Time to full weight bearing was from 5 to 13 months after surgery. All of the transferred fibulas showed hypertrophy after weight bearing. In one case, stress fracture was developed during ambulation, which was healed conservatively. Nonunion occurred in two cases, which were treated with a long leg cast and cancellous bone graft, respectively. Length discrepancy of the legs was noted. The limb was shorter by an average 0.5 cm in three cases, longer by 1.1 cm in one case. In the case of island fibula transfer, limited arc of rotation was not a problem. Other disabling complications were not seen. We believe that these diverse modalities using a vascularized fibula will make us more comfortable to handle major bone defects.

  • PDF