• Title/Summary/Keyword: Sedimentation Efficiency

Search Result 202, Processing Time 0.027 seconds

A study of improvement of river water quality(T-P) in pilot-scale operation (파일롯 규모의 운영에 따른 하천수질(T-P) 개선에 관한 연구)

  • Choi, Kyoungsoo;Lee, Chaeyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.323-334
    • /
    • 2021
  • Pilot-scale coagulation and sedimentation processes were operated to investigate the T-P (Total phosphorus) removal efficiency. A multiple regression model was also derived to predict the water quality improvement effect with river water characteristics. The inflow rates for the pilot-scale facility were 157-576 m3/day, and the coagulant doses were in the range of 13.7-58.5 mg/L (average 38.9 mg/L) for PAC (Poly alum chloride) and 16.5-62.1 mg/L (average 36.0 mg/L) for alum. The results found that the influent BOD (Biochemical oxygen demand) and T-P concentrations were 4.9 mg/L and 0.115 mg/L, and the removal efficiencies were 52.7% and 59.4%, respectively. T-P removal efficiencies on wet weather days were higher by 10% than dry weather days because influent solids influenced T-P's coagulation process. The pH of river water was 6.9-7.8, and the average pH was 7.3. Although the pH variation was not significant, the trend showed that the treatment efficiency of T-P and PO4-P removal increased. Thus, the pH range considered in this study seems to be appropriate for the coagulation process, which is essential for phosphorous removal. The T-P removal efficiencies were 19.6-93.3% (average 59.2%) for PAC and 16.4-98.5%(average 55.9%) for alum; thus, both coagulants showed similar results. Furthermore, the average coagulant doses were similar at 42.4 mg/L for PAC and 41.3 mg/L for alum. When the T-P concentration of the effluent was compared by the [Al]/[P] ratio, the phosphorus concentration of the treated water decreased with an increasing [Al]/[P] ratio, and the lowest T-P concentration range appeared at the [Al]/[P] ratio of 10-30. A seasonal multiple regression analysis equations were derived from the relationships between 10 independent and dependent variables (T-P concentration of effluent). This study could help lake water quality maintenance, reduce eutrophication, and improve direction settings for urban planning, especially plans related to developing waterfront cities.

Investigation on Design Aspects of the Constructed Wetlands for Agricultural Reservoirs Treatment in Korea (농업용 저수지 수질개선을 위한 국내 인공습지 설계 및 시공실태 조사)

  • Kim, Youngchul;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.23 no.2
    • /
    • pp.189-200
    • /
    • 2021
  • To improve the water quality of agricultural reservoirs, constructed wetlands are applied in many places. These are technologies that establish ecosystems and important design factors include water depth distribution, inflow and outflow, water flow distribution, hydraulic residence time, water quality treatment efficiency, aspect ratio, and the distribution of open water and covered water surfaces. For high efficiency during the operation of a constructed wetland, the design needs to be optimized and this requires consideration of the different types and length of the intake dam as well as the type and connection of wetland cells. Therefore, this study was conducted to investigate and suggest factors that needs to be considered during the design and for efficient operation measures through field surveys of 23 constructed wetlands that have been established and operated in agricultural reservoirs. Results of the field investigation shows that several sites were being operated improperly due to the malfunctioning or failure of the water level sensors, sedimentation in the intake dam, and clogging of the mechanical sluice frames. In addition, it was found that as the length of the inlet channel increases, the ecological disconnection between the intake dam upstream and the wetland outlet downstream also increases and was identified as a problem. Most of the wetlands are composed of 2 to 5 cells which can result to poor hydraulic efficiency and difficulty in management if they are too large. Moreover, it was found that the flow through a small wetland can be inadequate when there are too many cells due to excessive amounts of headloss.

Distribution of Acanthamoeba spp. in Raw Water and Water Treatment Process (상수원수 및 정수처리공정별 가시아메바 분포특성에 관한 연구)

  • Jung, Eun-Young;Jung, Mi-Eun;Park, Hong-Gi;Jung, Jong-Moon;Rho, Jae-Sun;Ryu, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1121-1127
    • /
    • 2008
  • The free-living amoeba and Acanthamoeba sp. are widely distributed in fresh water, soil, air and dust in the world. We studied distribution of amoeba from low Nakdong River(Mulgum and Maeri) and removal efficiency in water treatment process of Busan metropolitan city. During this investigation, water quality showed pH $7.4{\sim}9.6({\pm}1.1)$, water temperature $2.0{\sim}29.0({\pm}17)^{\circ}C$, turbidity $4.8{\sim}27.4({\pm}11.0)$ NTU, chlorophyll-a $10.3{\sim}109.0({\pm}44.3)\;mg/m^{3}$, BOD $1.7\sim4.9({\pm}2.6)$ mg/L, COD $3.1\sim-6.9({\pm}5.0)$ mg/L and total coliform $17\sim920({\pm}200.5)$ MPN/100 mL. The free-living amoeba were detected highly than Acanthamoeba sp., 11 out of 22 in raw water samples were positive (50%) for Acanthamoeba sp. from February 2005 to December 2005. The seasonal characteristics of tree-living amoeba and Acanthamoeba sp. in raw water were mainly distributed through the spring to the early fall. When tree-living amoeba and Acanthamoeba sp. were passed through the water treatment of pilot-plant, approximately 80% was sure to be removed through pre-ozonation, sedimentation, send filtration. 100% was removed after post-ozonation process. All of the isolated amoebas from Nakdong River were Acanthamoeba sp. AC311 18S ribosomal RNA gene with 98% nucleotide sequence homology.

A Study on the Hydraulic Experiments of Modi Khola Hydroelectric in Nepal (네팔 Modi Khola 수력발전소 수리모형실험 연구)

  • 선우중호;박창근
    • Water for future
    • /
    • v.28 no.1
    • /
    • pp.107-120
    • /
    • 1995
  • This study is concerned with the hydraulic experiments of Modi Khola Hydroelectric in Nepal. The experimental domain consists of the intake structure and the settling basin. The intake structure was made by the undistorted model with the scale of 1:20, the settling basin by the distorted model with the scale of 1:10(vertical) and 1:15(horizontal). Based on the movable bed model theory, the 'Anthracite'($\rho_s$ =1.48) is chosen as a model material. According to the model tests, the installation of the guide wall with proper height and the proper control of the flushing gate are required for the effective flushing in the intake structure. In the settling basin a more proper design of the inlet in order to constrain the turbulence flow is required for an efficient sedimentation and the installation of another flushing pipe near the maximum sedimental area is required. Since the trap efficiency is measured about 95%, it is concluded that the design of the settling basin is proper.

  • PDF

Application of Free Water Surface Constructed Wetland for Treating the Agricultural Runoff (강우시 농업 비점오염원 처리를 위한 FWS 인공습지의 적용성 평가)

  • Kang, Chang-Guk;Lee, So-Young;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • The areas for agricultural purposes in Korea are decreasing every year because of urbanization. However, it is still 17.6% of the total national boundary on 2008. Most of the rice paddy fields are located near the waterbodies which require lots of water during rainy season from May to September. Also lots of nitrate and phosphate chemical fertilizers are spread on the fields every year in order to supply the nutrients for vegetation. The excess nutrients is impairs the water quality of rivers and lakes when it is washed out from the fields. The Korean Ministry of Environment (MOE) adapted the new water quality improvement program, which is the Total Daily Maximum Load, to improve the water quality and to protect the aquaecosystems. The constructed wetland is one of the possible ways to treat the agricultural runoff. The constructed wetland on this study area was constructed by MOE in 2007 to evaluate the application of the constructed wetlands. Plant growth continues to increase during the summer until it reaches its highest biomass of 6,032 g/$m^2$ in August and September. More researches about sedimentation, vegetation, water balance, etc. were performed to evaluate the removal efficiency, to find the removal mechanisms and to make the guidelines for design and maintenance.

Total Phosphorus Removal Rate of a Subsurface-Flow Wetland System Constructed on Floodplain During Its Initial Operation Stage (고수부지에 조성한 수질정화 여과습지의 초기운영단계 총인 제거)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.6
    • /
    • pp.49-55
    • /
    • 2003
  • Total phosphorous removal rate was examined of a subsurface-flow treatment wetland system which was constructed on floodplain in the down reach of the Kwangju Stream in Korea from May to June 2001. Its dimensions were 29 meter in length, 9 meter in width and 0.65 meter in depth. A bottom layer of 45 cm in depth was filled with crushed granite with about 15~30 mm in diameter and a middle layer of 10 cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds(Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju Stream flowed from a submerged dam into it via a pipe by gravity flow and treated effluent was funneled back into the Stream. The number of reed stems increased from 80 stems/$m^2$ in July 2001 to 136 stems/$m^2$ in September 2001. The hight of stems was 44.2 cm in July 2001 and 75.3 cm in September 2001. The establishment of reeds at early operating stage of the system was good. Volume and water quality of inflow and outflow were investigated from July 2001 through December 2001. The average inflow was 40 $m^3$/day and hydraulic detention time was about 1.5 days. The concentration of total phosphorous n influent and effluent was 0.83 and 0.33 mg/L, respectively. The removal rate of total phosphorous averaged about 60%. The removal efficiency was slightly higher, compared with that of subsurface-flow wetlands operating in North America, whose retention rate of total phosphorous was reported to be about 56%. The good abatement rate could be attributed to sedimentation of particle phosphorous in pores of the media and adsorption of phosphorous to the biofilm developed on the surface of them. Increase of standing density of reeds within a few years will develop root zones which may lead to increment in the phosphorous retention rate.

Removal of Phosphorus and NOM in Wastewater Effluent Using Ejector.BAF System (분사배출 고도 응집.생물여과 공정을 이용한 하수처리수 중의 TP 및 NOM 제거)

  • Jang, Young-Ho;Kang, Dong-Han;Kim, Keugtae;Im, Heung-Bin;Hwang, Chan-Won;Kim, Mi-Jung;Shin, Hyung-Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.505-511
    • /
    • 2012
  • While the existing sewage treatment facilities are mainly being operated by biological processes, winter-time efficiency improvement and additional phosphorus treatment equipment using chemicals have been required to follow the effluent criteria of TP (0.2, 0.3 and 0.5 mg/L for the zone of I, II and III respectively) and $BOD_5$ (5.0 mg/L) which is intensified from 2012 in Republic of Korea. We made an investigation into actual condition of biological treatment process and calculated the optimal chemical input amount by jar test of supernatant of secondary sedimentation tank to evaluate the process improvement for the intensified criteria. Ejector BAF system for removing TP, $BOD_5$ of sewage effluent was suggested. The concentration of TP from biological process is 0.3-0.8 mg/L, and the input amount of optimal chemical coagulant was above Al/P ratio of 3(1.9 mg/L as Al) to meet the criteria of TP for secondary treatment effluent. From the results of this experiment, the best Al/P ratio for Ejector BAF system was about Al/P ratio of 1, and LV of BAF process for intensified criteria of $BOD_5$ and TP was below 1.97m/hr.

Application of ozone treatment in cooling water systems for energy and chemical conservation

  • Ataei, Abtin;Mirsaeed, Morteza Ghazi;Choi, Jun-Ki;Lashkarboluki, Reza
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.155-172
    • /
    • 2015
  • In this study, a complete set of recirculating cooling water system and the required instruments were built in a semi-industrial-scale and a 50 g/h ozone generation plant and a chlorine system were designed for cooling water treatment. Both chlorination and ozonation treatment methods were studied and the results were analyzed during two 45-days periods. The concentrations of ozone and chlorine in recirculating water were constant at 0.1 mg/lit and 0.6 mg/lit, respectively. In ozone treatment, by increasing the concentration cycle to 33%, the total water consumption decreased by 26% while 11.5% higher energy efficiency achieved thanks to a better elimination of bio-films. In case of Carbon Steel, the corrosion rate reached to 0.012 mm/yr and 0.025 mm/yr for the ozonation and chlorination processes, respectively. Furthermore, consumptions of the anti-corrosion and anti-sedimentation materials in the ozone cooling water treatment were reduced about 60% without using any oxidant and non-oxidant biocides. No significant changes in sediment load were seen in ozonation compared to chlorination. The Chemical Oxygen Demand of the blow-down in ozonation method decreased to one-sixth of that in the chlorination method. Moreover, the soluble iron and water turbidity in the ozonation method were reduced by 97.5% and 70%, respectively. Although no anaerobic bacteria were seen in the cooling water at the proper concentration range of ozone and chlorine, the aerobic bacteria in chlorine and ozone treatment methods were 900 and 200 CFU/ml, respectively. The results showed that the payback time for the ozone treatment is about 2.6 years.

A Study on the COD Removal in the Paste-board Wastewater by Activated Sludge Process (활성오니법에 의한 판지폐수중의 COD 제거에 관한 연구)

  • 도갑수;김영운
    • Journal of the Korean Professional Engineers Association
    • /
    • v.18 no.3
    • /
    • pp.28-35
    • /
    • 1985
  • As the paper industry consumes much water in process and discharge wastewater containing suspended solid and COD(chemical oxygen demand), relevant law against this discharge has been set up to limit the total containment of COD in discharge. This study has been carried out to improve the treatment method for the soluble COD in wastewater produced during the process of paste-board production, which is made of semichemical pulp and waste paper. Applicated methods are, O$_2$AS : O$_2$ activated sludge process DAS : Deep well activated sludge process SAS : standard activated sludge process and proper combination of DAS and SAS 1) As a result of this experiment, we get the following conclusion between in COD sludge loading "X" and COD removable rate in the process of treating waste-water. COD removable rate(%)=(0.778+0.0146/X)${\times}$100(%)……(7) 2) In case that the COD sludge loading is high, it has been cleared out that the COD removable rate shall become low due to unknown unsoluble substances contained in the process. Meanwhile, to increase the efficiency rate of treatment, it is thought to be necessary, to provide long-time contacts with activated sludge. 3) Once the COD of original waste-water and the target COD of treated water are decided, COD sludge loading is obtained from equation(7), and capacity of aeration tank in the effective systems such as O$_2$AS, DAS, to bet the required COD removable rate can be decided. Therefore the choice among SAS, O$_2$AS, DAS methods is made in consideration of required COD removable rate and allowable installation area. 4) In the sedimentation tank with sludge bulking, it is possible to increase the COD removable rate by 3~7% but still there exist many obstacles to manage this operation.

  • PDF

Experimental Application of DAF Hybrid Process to Remove Algae Particles for Conventional Water Treatment Processes and Change of Particle Characteristics (재래식 정수처리공정에서 조류입자 제거를 위한 DAF Hybrid 공정의 실험적 적용과 입자특성 변화)

  • Kwak, Dong-Heui;Yoo, Seung-Joon
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.516-520
    • /
    • 2008
  • There are many water treatment plants built over couple of decade ago in Korea. For most of those plants, they are required a countermeasure to cope with the deterioration caused from the superannuated facilities and the objective materials change of water treatment from inorganic particles like clay to algae particles due to eutrophication of lake and reservoir. A series of field and laboratory experiments was performed to investigate the feasibility of DAF hybrid process and the variation of particle characteristics by applying the additional DAF unit in conventional water treatment processes. On the basis of this experiments, the DAF was effective as an additive process in filtration basin (DAF-CSF combination processes). Using DAF-CSF combination process, the efficiency of stable particle removal can be achieved to produce the safe drinking water.