• Title/Summary/Keyword: Secure Switch

Search Result 29, Processing Time 0.031 seconds

3 Dimensional Electric Field Analysis for 362kv GIS and Analysis on the effect of particle attached on spacer (362kV GIS 차단부 3차원 전계해석 및 스페이서에 부착된 파티클의 영향 분석)

  • Ryu, Sung-Sic;Seok, Bok-Yeol;Lee, Hyeong-Goo;Kim, Yong-Han;Song, Tae-Hun;Choi, Young-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1773-1775
    • /
    • 2003
  • In this Study, the insulation safety for Closing Resistor and Disconnect Switch(DS) of 362kV GIS was estimated through 3 dimensional electric field analysis. In addition, the basic study to secure the electric insulation design technique was carried out through the research on the effect of a metallic particle which is generated in the GIS. As a result of 3 dimensional electric field analysis, it was found that the insulation capability of Closing Resistor and DS of 362kV GIS is stable electrically. Also, the fundamental data to improve the insulation capability of spacer was obtained by analyzing the maximum electric field according to the attached angle of a metallic particle which is attached on the surface of a spacer.

  • PDF

A Study on the Establishment of Facility Guidelines for Infectious Diseases Hospitals - Focusing on Operational Methods and Architectural Planning (감염병전문병원의 시설 가이드라인에 관한 연구 - 운영방식과 건축계획을 중심으로)

  • Choi, Kwangseok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.2
    • /
    • pp.17-29
    • /
    • 2022
  • Purpose: In terms of efficiency and safety, this study attempted to organize data on the operation methods and architectural planning of infectious diseases hospitals. Methods: The results obtained through on-site and interview surveys with hospital officials and medical staffs at four infectious diseases hospitals under construction were summarized based on those original business plans and facility guidelines. Results: First, the operational methods to secure safety and operational efficiency were summarized for each department which are major hospital functions of infectious disease hospitals. Second, as the architectural planning, the characteristics of space and circulation of each department are summarized. For safety of medical staff, negative pressure and non-negative pressure zone have to completely separated. In addition medical staff wears PPE and enters the negative pressure zone and returns in the order of admiral, shower, and gowning in the PPE undressing room after patient treatment. In case of operational efficiency, flexible operation is required in normal and crisis situations. For example, it is important for The Ward to gradually switch to negative pressure beds in times of crisis from normal situation and the outpatient department considers the composition of negative pressure and non-negative pressure outpatient spaces that can operate in parallel even in crisis situations. Implications: Infectious disease hospitals require flexible operation and appropriate facilities for normal and crisis situations.

Study on the Public Food Waste Recycling Facility Operation (II) - Focusing on Improvement Plan - (음식물류폐기물 공공 자원화시설 운영에 관한 연구 (II) - 개선방안을 중심으로 -)

  • Hong, Yong-Pyo;Kim, Ung-Yong;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • This study is conducted to find out the problems of the public food waste recycling facility operation and its improvement. In order to save the national budget by analyzing plans to expand including operation rate for the food waste recycling facility, the alternative ways are suggested. The result can be as follows: Policy switch is required not only to save budget and stable disposal of food waste but also to promote resource recycling rather than expanding public facilities. In order to change the policy for stable and eco-friendly disposal of food waste, it is necessary to adopt semipublic system that prevent the decline of the rate of operation of private resource recycling facility. Furthermore, it is required to prepare both qualified technologies of public resource recycling and the ways of profitability secure.

A Study on the Problems on ISDN Implementation Caused by the Conversion of Transmission System into Duropean Style in Korea (유럽 전송방식 도입에 따른 국내 ISDN 구축의 문제점 고찰)

  • 조규섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.2
    • /
    • pp.202-206
    • /
    • 1993
  • To secure the 64 kbps clear channel capability in the ISDN, it was decided to convert its North American digital transmission system into the European system especially in DS1 level. But their different companding law became an issue in the process of R&D in the existing time division digital switch such as TDX-1 to incorporate it into the ISDN. TDX-1 has been installed with North American ${\mu}$ companding law and its ISDN capability is under development now. Thus, because of the ${\mu}$ law/A law conversion for the interworking of two different transmission system, it is difficult to maintain the ISDN B channel transparency between TDX-1 and new European system with A companding law. Among some solutions for it, European frame format with ${\mu}$ law companding is recommended. Those problems and solutions are presented in this paper.

  • PDF

Performance Analysis of Cross-Layer Handoff Scheme in IP-Based Next-Generation Wireless Networks (IP기반 차세대 무선 네트워크에서의 교차계층 핸드오프 기법의 성능 분석)

  • Lee, JaeSuk;Jeong, Jongpil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.6
    • /
    • pp.454-472
    • /
    • 2013
  • The development of wireless network technology and the increasing use of wireless networks to mobile users with a variety of wireless network systems has arisen. Wireless sensor networks, they can be nested together, and the need to switch between the network, depending on your needs. Next Generation Wireless Networks(NGWN) gives the mobile user a wide coverage and optimized service etc. Previous hand off management protocol is not enough to secure support of the NGWN application program. Cross-layer Handoff(CLH) protocol technique has been developed to support between and inside networks of handoff management of NGWN. CLH supports mobility management in a wireless network environment and also utilizes mobility speed and handoff signaling delay information to improve the handoff performance ability. For the analysis of handoff performance ability, we analyzed sensitivity of link layer and network layer, therefore, CLH technique is suggested based on this analysis.

A Snoop-Based Kernel Introspection System against Address Translation Redirection Attack (메모리 주소 변환 공격을 탐지하기 위한 Snoop기반의 커널 검사 시스템)

  • Kim, Donguk;Kim, Jihoon;Park, Jinbum;Kim, Jinmok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.5
    • /
    • pp.1151-1160
    • /
    • 2016
  • A TrustZone-based rootkit detecting solution using a secure timer ensures the integrity of monitoring system, because ARM TrustZone technology provides isolated environments from a monitored OS against intercepting and modifying invoke commands. However, it is vulnerable to transient attack due to periodic monitoring. Also, Address Translation Redirection Attack (ATRA) cannot be detected, because the monitoring is operated by using the physical address of memory. To ameliorate this problem, we propose a snoop-based kernel introspection system. The proposed system can monitor a kernel memory in real-time by using a snooper, and detect memory-bound ATRA by introspecting kernel pages every context switch of processes. Experimental results show that the proposed system successfully protects the kernel memory without incurring any significant performance penalty in run-time.

Comparative Study on the Expertise, Convenience, and Interaction of Medical Treatment Systems Applied by Geriatric Hospital (요양병원 진료시스템에 따른 진료전문성, 편의성, 상호작용성의 역할 비교연구)

  • Yoon, Sung-Wook;Ryu, Jeong-Geon;Kim, Su-Bae
    • Journal of Distribution Research
    • /
    • v.11 no.3
    • /
    • pp.1-22
    • /
    • 2006
  • Medical treatment for the aged has become an increasingly important concern as the aged population continues to grow. However, little research has been done on the issue. This study examines the roles of the expertise, convenience, and interaction of medical treatment systems applied by geriatric hospital. Medical treatment systems include oriental medicine, western medicine and integrated(oriental and western) medicine practices. The empirical results of the study are as follows. First, the relative impacts of the expertise, convenience and interaction on customer satisfaction are different depending upon the medical treatment systems. Second, convenience and interaction are shown to be more important factors in western medicine, while interaction is the case in oriental medicine. As for the integrated medicine practices, expertise is considered more important. Thus, it is necessary for the western medicine to make more efforts on interaction and convenience, while it is critical to enhance medical personnels' service quality in the oriental medicine. In the integrated medical treatment, actual and effective cooperation should be achieved to secure expertise. Third, the data demonstrate that customer satisfaction has a positive influence on relationship quality which, in turn, impacts on repurchase intention. Finally, relationship quality has a negative influence on intention to switch in the western medicine, whereas the impact of relationship quality is not significant in the oriental and integrated medicine practices.

  • PDF

Design of Safety and Arming Device of the Fuze using Solenoid for Improving Safety (안전성 증대를 위해 솔레노이드를 적용한 신관 안전장전장치 설계)

  • An, Ji Yeon;Jung, Myung Suk;Kim, Ki Lyug
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.197-203
    • /
    • 2014
  • The safety and arming device(SAD), one of the components of the fuzes, shall provide safety that is consistent with handling, storage, transportation, use, and disposal. In this paper, we describes the design of the SAD which includes the solenoid assembly and the solenoid driving circuit to improve the safety of the fuzes. The solenoid assembly consists of a coil assembly, a restoring spring, and a core. The solenoid assembly is added in the SAD as an additional safety device. In case of the normal circumstances, the core of the solenoid assembly restrains the $1^{st}$ and $2^{nd}$ safety devices of the SAD for those devices not to operate at all, so that the SAD can secure safety for storage, transportation, and use. In contrast, when the battery power is provided to the solenoid driving circuit just before the flight, the core confirms the power level and starts removing the restraint from the $1^{st}$ and $2^{nd}$ safety devices of the SAD, and then the SAD is able to change its mode from safety mode to armed mode. After firing, once the SAD's operations complete, the turned-on arming switch stops providing the power to the solenoid assembly automatically. It can reduce the power consumption at solenoid assembly. Therefore, the proposed solenoid driving circuit for the solenoid assembly not only unlocks the restrained solenoid assembly from the safety devices, but also saves the power consumption during the flight.

Analysis of the Melting Characteristics of a Blade Type Fuse Used for Vehicles Due to Overload (과부하에 따른 차량용 블레이드형 퓨즈의 용단특성 해석)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.38-43
    • /
    • 2010
  • The purpose of this study is to secure the basis for judgment on the cause of an accident by analyzing the melting characteristics of a blade type fuse used for vehicles due to overload. In order to increase the reliability of the test, it was conducted by connecting the electrical system with conditions similar to those of an actual vehicle to apply the load. Carbonization pattern experiment of fuse by outside flame applied Korean Standard (KS). The fuse melted by the overcurrent showed a smooth cross-section while the test terminals, clear plastic body, etc., burnt out by the external flame was badly deformed. When 185% of the rated current (27.8A) was applied to a cable of 15A rated current onto which an over-capacity fuse (20A) was installed, the fuse melting time was 217 seconds. In addition, when a load current of 28.8[A] (139%) was applied, the fuse's test terminal and terminal blade were not burnt out although foam was observed on some parts of the plastic body. When a load capacity of 28.2[A] (141%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melting time was approximately 10 seconds. When a load current of 35.8[A] (119%) was applied, the fuse's test terminal and terminal blade were not burnt out, although some parts of the plastic body was swelled. However, it was observed that the switch terminal melted if approximately six minutes lapsed under such conditions. When a load capacity of 39.4[A] (131%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melted in approximately 69 seconds, and the test terminal and terminal blade were not burnt.