• Title/Summary/Keyword: Sectional image

Search Result 335, Processing Time 0.029 seconds

Prediction of Cured Cross-sectional Image in Projection Microstereolithography (전사방식 마이크로광조형의 경화 단면형상 예측)

  • Kim, Sung-Hyun;Park, In-Baek;Ha, Young-Myoung;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.102-108
    • /
    • 2010
  • Projection microstereolithography is a process of fabricating a micro-structure by using dynamic mask such as digital micromirror device(DMD). DMD shapes the beam into cross-sectional image of structure. Photocurable resin is cured by the beam and stacked layer on top of layer. It is difficult to deliver the beam from the DMD to the photocurable resin without any distortions. We assume that the beam exposed to the resin by 1 pixel of DMD has Gaussian distribution, so the shaped beam reflected by the DMD affects its neighboring area. Curing pattern corresponding to a cross-sectional images is predicted by superposition of pixels of Gaussian distribution and it is similar to cured shape.

Deformation Measurement of Polymer Scaffold Using Particle Image Analysis (입자 영상 해석을 이용한 고분자 지지체 변형 측정)

  • Kang, Min Je;Oh, Sang Hoon;Rhee, Kyehan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • Polydimethylsiloxane (PDMS) is used as a scaffold for cell culture. Because both the stress and strain acting on the substrate and the hemodynamic environment are important for studying mechano-transduction of cellular function, the traction force of the surface of a substrate has been measured using fluorescence images of particle distribution. In this study, deformation of the cross-sectional plane of a PDMS block was measured by correlating particle image distributions to validate the particle image strain measurement technique. Deformation was induced by a cone indentor and a shearing parallel plate. Measured deformations from particle image distributions were in agreement with the results of a computational structure analysis using the finite-element method. This study demonstrates that the particle image correlation method facilitates measurement of deformation of a polymer scaffold in the cross-sectional plane.

Sectional corner matching for automatic relative orientation

  • Seo, Ji-Hun;Bang, Ki-In;Kim, Kyung-Ok
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.74-74
    • /
    • 2002
  • This paper describes a corner matching technique for automatic relative orientation. Automatically matched corner points from stereo aerial images are used to a data set and help to improve automation of relative orientation process. A general corner matching process of overall image to image has very heavy operation and repetitive computation, so very time-consuming. But aerial stereo images are approximately seventy percent overlapped and little rotated. Based this hypothesis, we designed a sectional corner matching technique calculating correlation section by section between stereo images. Although the overlap information is not accurate, if we know it approximately, the matching process can be lighter. Since the size of aerial image is very large, corner extraction process is performed hierarchically by creating image pyramid, and corners extracted are refined at the higher level image. Extracted corners at the final step are matched section by section. Matched corners are filtered using positional information and their relation and distribution. Filtering process is applied over several steps because the thing affecting to get good result-good relative orientation parameter- is not the number of matched corner points but the accuracy of them. Filtered data is filtered one more during the process calculating relative orientation parameters. When the process is finished, we can get the well matched corner points and the refined Von-Gruber areas besides relative orientation parameters. This sectional corner matching technique is efficient by decreasing unnecessarily repetitive operations and contributes to improve automation for relative orientation.

  • PDF

2-D OCT image implementation using low coherence SLD (Low coherence 특성의 SLD를 이용한 2차원 OCT 영상 구현)

  • 정태호;박양하;오상기;김용평
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.290-291
    • /
    • 2003
  • Optical Coherence Tomography is a new medical dianostic imaging technology which can perform micron resolution cross-sectional or tomograpic imaging in biological tissue. In this paper, we analyze OCT system. And we have 2-dimensional OCT image implementation using low coherence SLD.

  • PDF

Improved Algorithm of Sectional Tone Mapping for HDR Images (HDR 이미지를 위한 단면 톤 매핑 개선 알고리즘 구현)

  • Lee, Yong-Hwan;Kim, Heung-Jun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.2
    • /
    • pp.137-140
    • /
    • 2021
  • High dynamic range (HDR) technology has been drawing attention in the field of imaging and consumer entertainment. As tools for capturing and creating HDR contents, encoding, and transmission evolve to support HDR formats, various display capabilities are being developed and increased. Hence, there is need for remapping native HDR imagery for display on lower quality legacy standard dynamic range (SDR) displays. This operation is referred to as tone mapping. In this paper, we present a sectional tone mapping method by Lenzen, and expand upon a tone mapping approach to improve temporal stability while maintaining picture quality. Compared to the existing block-based sectional tone mapping, our method uses the edge awareness-based tone mapping. We estimate the performance of the objective metric on temporal flickering. The experimental result shows that the algorithm maintains a smoother relationship between the output luminance values, and this reveals success in reducing halos and improving temporal stability with adopted edge aware filtering.

Preparation of Cross-sectional Specimen for High Resolution Observation of Coating Structure and Visualization of Styrene/butadiene Latex Binder (고배율 도공층 구조 및 S/B latex 분포 분석을 위한 도공층 횡단면 제작)

  • Kim, Chae-Hoon;Youn, Hye-Jung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.4
    • /
    • pp.16-24
    • /
    • 2012
  • To characterize the coating structure, diverse methods such as mercury intrusion, nitrogen adsorption and oil absorption methods have been developed and widely employed. These indirect techniques, however, have some limitation to explain the actual coating structure. Recently microscopic observation methods have been tried for analyzing structural characteristics of coating layers. Preparation of the undamaged cross section of a coating layer is essential for obtaining high quality image for analysis. In this study, distortion-free cross-section of the coating layer was prepared using a grinding and polishing technique. The coated paper was embedded in epoxy resin and cured. After curing the resin block it was ground with abrasive papers and then polished with diamond particle suspension and nylon cloth. Polished coating layer was sufficient enough to obtain undamaged cross sectional images with scanning electron microscope under backscattered electron image mode. In addition, the SEM images allowed distinction of the coating layer components. Also S/B latex film formed between pigment particles was visualized by osmium tetroxide staining. Pore size distribution and pore orientation were evaluated by image analysis from SEM cross-sectional images.

Center Determination for Cone-Beam X-ray Tomography

  • Narkbuakaew, W.;Ngamanekrat, S.;Withayachumnankul, W.;Pintavirooj, C.;Sangworasil, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1885-1888
    • /
    • 2004
  • In order to render 3D model of the bone, the stack of cross-sectional images must be reconstructed from a series of X-ray radiographs, served as the projections. In the case where the distance between x-ray source and detector is not infinite, image reconstruction from projection based on parallel-beam geometry provides an error in the cross-sectional image. In such case, image reconstruction from projection based on conebeam geometry must be exercised instead. This paper is devoted to the determination of detector center for SART conebeam Technique which is critically effect the performance of the resulting 3D modeling.

  • PDF

CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT)

  • Jeon, Ki-Wan;Lee, Chang-Ock;Kim, Hyung-Joong;Woo, Eung-Je;Seo, Jin-Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.279-287
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging modality providing cross-sectional images of a conductivity distribution inside an electrically conducting object. MREIT has rapidly progressed in its theory, algorithm and experimental technique and now reached the stage of in vivo animal and human experiments. Conductivity image reconstructions in MREIT require various steps of carefully implemented numerical computations. To facilitate MREIT research, there is a pressing need for an MREIT software package with an efficient user interface. In this paper, we present an example of such a software, called CoReHA which stands for conductivity reconstructor using harmonic algorithms. It offers various computational tools including preprocessing of MREIT data, identification of boundary geometry, electrode modeling, meshing and implementation of the finite element method. Conductivity image reconstruction methods based on the harmonic $B_z$ algorithm are used to produce cross-sectional conductivity images. After summarizing basics of MREIT theory and experimental method, we describe technical details of each data processing task for conductivity image reconstructions. We pay attention to pitfalls and cautions in their numerical implementations. The presented software will be useful to researchers in the field of MREIT for simulation as well as experimental studies.

Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe (사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발)

  • Lee, Kyoung-Hwang;Lee, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

Study on an Extraction Method for a Fuel Rod Image and a Visualization of the Color Information in a Sectional Image of a Spent Fuel Assembly (사용후핵연료집합체 영상에서 핵연료봉 영상 추출방법과 색상정보의 가시화에 관한 연구)

  • Jang, Ji-Woon;Shin, Hee-Sung;Youn, Cheung;Kim, Ho-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.432-441
    • /
    • 2007
  • Image processing methods for an extraction of a nuclear fuel rod image and visualization methods of the RGB color data were studied with a sectional image of spent fuel assembly. The fuel rod images could be extracted by using a histogram analysis, an edge detection and RGB rotor data. In these results, a size of the spent fuel assembly could be measured by using a histogram analysis method and a shape of the spent fuel rod could be observed by using an edge detection method. Finally, a various analyses were established for status of the spent fuel assembly by realized various 3D images for the color data in an image of a spent fuel assembly.