• 제목/요약/키워드: Section deviation

검색결과 176건 처리시간 0.03초

단일 2차원 라이다 기반의 다중 특징 비교를 이용한 장애물 분류 기법 (Obstacle Classification Method using Multi Feature Comparison Based on Single 2D LiDAR)

  • 이무현;허수정;박용완
    • 제어로봇시스템학회논문지
    • /
    • 제22권4호
    • /
    • pp.253-265
    • /
    • 2016
  • We propose an obstacle classification method using multi-decision factors and decision sections based on Single 2D LiDAR. The existing obstacle classification method based on single 2D LiDAR has two specific advantages: accuracy and decreased calculation time. However, it was difficult to classify obstacle type, and therefore accurate path planning was not possible. To overcome this problem, a method of classifying obstacle type based on width data was proposed. However, width data was not sufficient to enable accurate obstacle classification. The proposed algorithm of this paper involves the comparison between decision factor and decision section to classify obstacle type. Decision factor and decision section was determined using width, standard deviation of distance, average normalized intensity, and standard deviation of normalized intensity data. Experiments using a real autonomous vehicle in a real environment showed that calculation time decreased in comparison with 2D LiDAR-based method, thus demonstrating the possibility of obstacle type classification using single 2D LiDAR.

비대칭 사다리꼴 단면 선재의 다단 인발 공정설계 (Process Design of Multi-Pass Shape Drawing of Wire with Asymmetric Trapezoid Profiles)

  • 지세인;이경훈;홍리석;정진영;김종성;김병민
    • 소성∙가공
    • /
    • 제24권3호
    • /
    • pp.187-193
    • /
    • 2015
  • The objective of the current study is to determine cross-sectional profile of intermediate dies in order to improve the plastic strain homogeneity which directly affects not only the dimensional accuracy but also the mechanical properties of final product by redesigning the intermediate dies using the conventional electric field analysis (EFA) method. Initially, the multi-pass shape wire drawing was designed by using the equivalent potential lines from EFA. The area reduction ratio was calculated from the number of passes in multi-pass shape wire drawing but constrained by the capacity of the drawing machine and the drawing force. In order to compensate for a concentration of strain in a region of the cross section of the wire, the process for multi pass wire drawing from initial round material to an intermediate die was redesigned again using the electric field analysis. Both drawing process designs were simulated by the finite element method in which the strain distribution and standard deviation plastic strain of the cross section of drawn wires were examined.

교류 LED 조명의 빛 밝기 편차를 최소화하는 방법에 대한 연구 (A Study on How to Minimize the Luminance Deviation of AC-LED Lighting)

  • 이동원;이봉희;김병철
    • 한국전기전자재료학회논문지
    • /
    • 제36권3호
    • /
    • pp.255-260
    • /
    • 2023
  • In order to spread LED lighting, LED lighting technology directly driven by alternating current (AC) commercial power has recently been introduced. Since current does not flow at a voltage lower than the threshold voltage of the LED, a non-conductive section occurs in the current waveform, and the higher the threshold voltage of the LED, the more discontinuous current waveforms are generated. In this paper, multi-LED modules are connected in series so that the threshold voltage can be adjusted according to the number of LED modules. A small number of LED modules are driven at a low instantaneous rectified voltage, and a large number of LED modules are driven at a high instantaneous rectified voltage to lengthen the overall lighting time of AC-LED lighting, thereby minimizing the luminance deviation of AC-LED lighting. In addition, the load current flowing through the LED module is adjusted to be the same as the design current even at the maximum rectified voltage higher than the design voltage, so that the light brightness of the LED module is kept constant. Therefore, even if the rectified voltage applied to the LED module changes, the AC-LED lighting in which the light brightness is constant and the luminance deviation is minimal has been realized.

구강스캐너 5종의 협측 악간관계 스캔 정확성 비교 연구 (Accuracy comparison of buccal bite scans by five intra-oral scanners)

  • 박지만;전진;허성주
    • 구강회복응용과학지
    • /
    • 제34권1호
    • /
    • pp.17-31
    • /
    • 2018
  • 목적: 이 연구의 목적은 다양한 구강 스캐너를 사용하여 협측 악간관계 스캔에 따른 상하악 악궁 관계의 정확성을 비교 평가하는 것이다. 연구 재료 및 방법: 정상 교합을 보이는 상하악 전악 모델을 5종(Cerec Omnicam, CS3500, iTero, Trios, TruDef)의 구강 스캐너로 제조사의 지시대로 스캔하였다. 폴리비닐실록산 교합 재료로 고정시킨 금속 지그를 이용하여 우측 구치부를 1, 2, 3, 4 mm 단계적으로 올린 후 좌측 협측 악간관계 스캔을 채득하였다. 두 데이터를 중첩하여 전체적인 삼차원 변이를 평가하였고, 교합 평면에 수직인 단면을 분석하여 교두간 거리의 양과 방향을 평가하였다. 결과: 중첩연구에서 Cerec Omnicam ($165.5{\mu}m$)이 가장 적은 변이를 보였고, CS3500 ($369.0{\mu}m$)이 가장 큰 변이를 보였으며(P < 0.01), 1 mm 보다 3, 4, 2 mm 이개 그룹에서 변이가 유의미하게 컸다(P < 0.01). 단면 연구에서는 Cerec Omnicam이 교두끼리의 거리가 가장 먼 변이를 보였고($-242.8{\mu}m$), CS3500이 가장 가까워지는 변이를 보였으며($312.5{\mu}m$), 다른 거상 높이 보다 3 mm 이개 그룹에서 유의하게 변이가 컸다(P < 0.01). 결론: 구강 스캐너 마다 협측 악간관계 스캔을 이용해 상하악 교합 관계를 재현하는 정확성이 달랐다.

측정 자세에 따른 HRV변화 (The effect of posture on HRV)

  • 양동인;심영우;노형욱;김덕원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.399-401
    • /
    • 2009
  • The purpose of this study is looking for deviation of change in HRV caused of posture. Total 20 adults were measured for 40 minutes(10 minutes rest section and 30 minutes analysis section) when volunteers were sitting and lying down. Other factors which can change in HRV were controlled during measurement. The analysis section were divided by total 6 stages(each by 5 minutes), and compared and analyzed between sitting and lying down groups. It was also compared and analyzed stages in each group. In the result, there was difference at stage 5($20{\sim}25$ minutes interval), but no difference in the total data. The results of each stage in the group, lying down had difference. Therefore, sitting is more stable measurement for HRV study when subjects was waking over 15 minutes.

  • PDF

열중성자로 핵계산을 위한 69군 단면적 라이브러리 생산 및 검증 (Generation and Benchmarking of a 69-group Cross Section Library for Thermal Reactor Applications)

  • Kim, Jung-Do;Lee, Jong-Tai;Gil, Choong-Sup;Kim, Hark-Rho
    • Nuclear Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.245-258
    • /
    • 1989
  • 열중성자로의 핵계산을 위한 69군 단면적 라이브러리를 생산하였다. 기본 평가핵자료로는 IAEA Nuclear Data Section에서 수집된 자료가, 그리고 이를 처리하여 군정수화 하는데는 NJOY코드가 이용되었다. 새로이 마련된 라이브러리의 유용성을 검증하기 위해 각기 산화우라늄과 금속 우라늄 연료로 구성된 임계실험치를 WIMS-KAERI 코드로 계산된 결과와 비교, 검토하였다. 총 88임계결과에 대해 평균 $K_{eff}$ 값 0.9997, 그리고 표준 편차 0.69%를 보였다. PWR 연료의 연소결과로 얻어진 우라늄과 플루토늄 생성량에 대한 평가에서도 전반적으로 좋은 결과를 얻었다.다.

  • PDF

Prediction of scour around single vertical piers with different cross-section shapes

  • Bordbar, Amir;Sharifi, Soroosh;Hemida, Hassan
    • Ocean Systems Engineering
    • /
    • 제11권1호
    • /
    • pp.43-58
    • /
    • 2021
  • In the present work, a 3D numerical model is proposed to study local scouring around single vertical piers with different cross-section shapes under steady-current flow. The model solves the flow field and sediment transport processes using a coupled approach. The flow field is obtained by solving the Unsteady Reynolds Averaged Navier-Stokes (URANS) equations in combination with the k-ω SST turbulence closure model and the sediment transport is considered using both bedload and suspended load models. The proposed model is validated against the empirical measurements of local scour around single vertical piers with circular, square, and diamond cross-section shapes obtained from the literature. The measurement of scour depth in equilibrium condition for the simulations reveal the differences of 4.6%, 6.7% and 13.1% from the experimental measurements for the circular, square, and diamond pier cases, respectively. The model displayed a remarkable performance in the prediction of scour around circular and square piers where horseshoe vortices (HSVs) have a leading impact on scour progression. On the other hand, the maximum deviation was found in the case of the diamond pier where HSVs are weak and have minimum impact on the formation of local scour. Overall, the results confirm that the prediction capability of the present model is almost independent of the strength of the formed HSVs and pier cross-section shapes.

하천 만곡률과 홍수량에 따른 수면경사도 산정 (Estimation of the Water Surface Slope by the Flood Discharge with River Bend Curvature)

  • 최한규;이문희;백효선
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.129-137
    • /
    • 2006
  • In this research, we made a one and two-dimensional analysis of numerical data collected from the bend curvature of a bended river section. According to the result from the numerical analysis, the inflow & output angle caused a water level deviation which increased with an increase of the flood discharge. From the water level deviation of our two-dimensional numerical model, we obtained the maximum slope of 6,67% when the inflow and output angle was 105 degrees and the flood discharge was 500 CMS. As for the right side, the differences with the one-dimensional numerical model were reduced when the angle was more than $90^{\circ}$. As for the left side the differences were reduced when the angle was more than $105^{\circ}$. For a river with more than 90 degrees bend curvature, a hydraulic experiment would be more appropriate than a numerical analysis.

  • PDF

Design and Simulation of Heating Rubber Roller for Laminating Process

  • Hur, Shin;Woo, Chang Su
    • Elastomers and Composites
    • /
    • 제51권4호
    • /
    • pp.280-285
    • /
    • 2016
  • The purpose of this study is to get optimum design and operation conditions of the heating rubber roller for laminating process. The cause of performance degradation of heating rubber roller is delamination of rubber on metal tube, rubber aging due to high temperature. We measured the material properties of thermal expansion, thermal conductivity, specific heat and density and analyzed thermal distributions of rubber layer using finite element method. As a result of heat/flow analysis, the density distribution of heating coil must shorten the stabilization time by reducing the temperature deviation on the length direction at the temperature rising section after increasing the density of the area contacting with the laminate film at the center part which is an opposite of the current composition while enabling to maintain the temperature of heater to be consistent while maintaining the temperature deviation to be low when heat loss is created. Finally, we determined optimum heating method of heating rubber roller.

A Novel High Precision Electromagnetic Suspension for Long-Stroke Movement and Its Performance Evaluation

  • Lee, Ki-Chang;Moon, Seokhwan;Ha, Hyunuk;Park, Byoung-Gun;Kim, Ji-Won;Baek, Jun-Young;Lee, Min-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.514-522
    • /
    • 2014
  • A new type of high precision electromagnetic suspension (EMS) which can support heavy tray along long stroke rail is proposed in this paper. Compared with the conventional EMS, the suggested moving-core typed EMS has the levitation electromagnets (EMs) on the fixed rail. This scheme has high load capability caused by iron-core and enables simple tray structure. Also it does not have precision degradation caused by heat generation from EMs, which is a drawback of conventional EMS. With these merits, the proposed EMS can be an optimal contactless linear bearing in next generation flat panel display (FPD) manufacturing process if the ability of long stroke movement is proved. So a special Section Switching Algorithm (SSA) is derived from the resultant force and moment equations of the levitated tray which enables long stroke movement of the tray. In order to verify the feasibility of the suggested SSA, a simple test-setup of the EMS with 2 Section-changes is made up and servo-controlled in the simulation and experiment. The simulation shows the perfect changeover the EMs, and the experiment shows overall control performance of under ${\pm}40{\mu}m$ gap deviations. These results reveal that the newly suggested contactless linear bearing can simultaneously achieve high load capability and precision gap control as well as long stroke.