• 제목/요약/키워드: Section Factor

검색결과 1,052건 처리시간 0.021초

Electron Transport Properties in Xenon Gas Detectors

  • Date, H.;Ishimaru, Y.;Shimozuma, M.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.285-288
    • /
    • 2002
  • In this study, we investigate electron transport properties in xenon gas by using a Monte Carlo technique for electrons with energies below 10 keV. First of all, we determine a set of electron collision cross sections with xenon by scrutinizing the cross section data taken from many publications. Then, the W value and the Fano factor for electrons in gaseous xenon are computed by the Monte Carlo simulation on the assumption that electrons undergo single collision events including elastic, excitation and ionization processes. We also evaluate the production number of excited atoms.

  • PDF

Numerical analysis of a complex slope instability: Pseudo-wedge failure

  • Babanouri, Nima;Sarfarazi, Vahab
    • Geomechanics and Engineering
    • /
    • 제15권1호
    • /
    • pp.669-676
    • /
    • 2018
  • The "pseudo-wedge" failure is a name for a complex instability occurring at the Sarcheshmeh open-pit mine (Iran). The pseudo-wedge failure contains both the rock bridge failure and sliding along pre-existing discontinuities. In this paper, a cross section of the failure area was first modeled using a bonded-particle method. The results indicated development of tensile cracks at the slope toe which explains the freedom of pseudo-wedge blocks to slide. Then, a three-dimensional discrete element method was used to perform a block analysis of the instability. The technique of shear strength reduction was used to calculate the factor of safety. Finally, the influence of geometrical characteristics of the mine wall on the pseudo-wedge failure was investigated. The safety factor significantly increases as the dip and dip direction of the wall decrease, and reaches an acceptable value with a 10-degree decrease of them.

임계 경사각을 고려한 기계적 체결부 균열의 혼합모드 피로균열성장 거동 (Mixed-Mode Fatigue Crack Growth Behavior of Cracks in Mechanical Joints Considering Critical Inclined Angle)

  • 허성필;양원호;정기현;류명해
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.187-192
    • /
    • 2001
  • Cracks in mechanical joints is generally under mixed-mode and there is the critical inclined angle at which mode I stress intensity factor becomes maximum. In order to evaluate the fatigue life of cracks in mechanical joints, horizontal crack normal to the applied load and located on minimum cross section is major concern but critical inclined crack must also be considered. In this paper mixed-mode fatigue crack growth test is performed for horizontal crack and critical inclined crack in mechanical joints. Fatigue crack growth path is predicted by maximum tangential stress criterion using mode I and mode II stress intensity factors obtained from weight function method, and fatigue crack growth rates of horizontal and inclined crack are compared.

  • PDF

커넥팅 로드의 피로강도에 대한 신뢰성 해석 (Reliability Analysis in Fatigue Strength of Connecting Rod)

  • 김철수;이준형;김정규
    • 대한기계학회논문집A
    • /
    • 제25권10호
    • /
    • pp.1651-1658
    • /
    • 2001
  • It is necessary to evaluate fatigue strength and reliability of the connecting rod which is core part in automotive engine to assure the high level of durability of automobile. For this purpose, the loading conditions in automotive engine is obtained by the dynamic analysis. Based on these results, the critical section was identified by the finite element analysis. The fatigue strength under constant amplitude was evaluated and the mean of the fatigue limit at R = -2.27 derived from the staircase method was 311.2MPa. And the failure probability( F$\sub$p/ ) derived from the strength-stress interference model is 0.0003% at the 99.99% confidence level and the mean factor of safety was 4.2.

4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가 (Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy)

  • 유하늬;이주윤;송규동
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

일체형 보강판의 균열성장거동(II) - SIF의 실험해석 - (Crack Growth Behavior in the Integrally Stiffened Plates(ll) - Experimental Evaluation of SIF-)

  • 이환우
    • 한국정밀공학회지
    • /
    • 제14권6호
    • /
    • pp.114-120
    • /
    • 1997
  • To assess the validity of the previously computed finite element analysis results, the photoelastic experiment was carried out to determine stress intensity factors for crack originating from thin section of integrally stiffened plates having discontinuous thickness interface. The stress intensity factors were deter- mined by using linear slope method of photoelastic data. Results are presented as variable thickness geometry factor. $F_{IV}$ , for various crack lengths and thickness ratios. The experimental values of F/ sub IV/are compared with 3-D finite element analysis results. The correlation between experimental values and analysis results is resonably good.

  • PDF

Analysis of Jamming Robustness Performance According to RNSS Signal Waveforms

  • Subin Lee;Kahee Han;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.229-236
    • /
    • 2023
  • As the importance and dependency of the positioning, navigation, and timing (PNT) information provided by the radio navigation satellite service (RNSS) increases, the vulnerability of RNSS to jamming can lead to significant risks. The signal design under the consideration of anti-jamming performance helps to provide service which is robust to jamming environment. Therefore, it is necessary to evaluate the jamming robustness performance during the design of new signals. In this paper, we introduce figures-of-merit (FoMs) that can be used for an anti-jamming performance analysis of designed signals of interest. We then calculate the FoMs, such as the quality factor (Q factor), tolerable jamming-to-signal ratio (tolerable J/S), and range to jammer (d) for legacy RNSS signals and analyze the results. Finally, based on the results of the analysis, we derive waveform design conditions to obtain good anti-jamming performance. As a result, this paper shows that the waveforms with wide bandwidth leading to good spectral efficiency provide strong anti-jamming performance.

하천 제방의 취약성 분석 지수 개발 및 적용 (Development and Application of Vulnerability Analysis Index for River Levee)

  • 이후상;이재준
    • 한국습지학회지
    • /
    • 제21권spc호
    • /
    • pp.134-140
    • /
    • 2019
  • 본 연구에서는 하천 제방에 대한 홍수취약성을 평가하는 새로운 기법으로 제방홍수취약성지수를 제안하였고 제방홍수취약성 지수를 산정하는데 있어 필요한 인자를 적용하는 방법에 대하여 알아보고자 한다. 이를 위해 먼저 대상 제방의 계획홍수위를 적용하여 제방의 안전율을 분석하였고, 제방의 인자들로는 여유고, 둑마루폭, 제방단면의 비, 활동안전율, 턱(소단)의 길이, 침윤선 길이 비, 한계유속으로 7가지의 인자들을 바탕으로 제방홍수취약성지수를 산출하였다. 이를 활용하여 제방의 취약성 분석을 실시하고 분석결과를 제방홍수취약성지수(Levee Flood Vulnerability Index, LFVI) 값을 이용하여 1~7등급으로 나누어 제방의 취약성을 평가하였다.

화력 발전용 고압 로터강의 정하중 및 변동하중하의 고온 크립 균열전파 특성에 관한 연구 (A Study on the High Temperature Creep Crack Growth Properties for Steam Turbine Rotor Steel under Static and Cyclic Loading Condition)

  • 오세규;정순억
    • 한국해양공학회지
    • /
    • 제5권2호
    • /
    • pp.207-207
    • /
    • 1991
  • The crack length measurements by electrical potential(EP) method for 1% Cr-Mo-V and 12%Cr steel of 0.5T-CT specimen were performed at $500^{\circ}C, 600^{\circ}C 700^{\circ}C$, and an applicability of stress intensity factor($K_I$), net section stress($\sigma_{net}$), $C^*$-ingegral and $C_t$ parameter was studied to measure creep crack growth rate(da/dt) with side groove and without side groove under static and cyclic loading condition. The experimental result could be summarized as follows: 1) Crack measurement by EP method was available and coincided with the Johnson,s analytical equation. 2) da/dt by $K_I$ and $\sigma_{net}$ was not adequate because of the wide scatter band according to load and temperature, but $C^*$-integral, except for transition region, was adequate. 3) $C_t$ parameter showed the best fitted line through total creep region without relating with both temperature and load condition. 4) Under the cyclic loading condition, $C_t$ parameter was proper to extimate da/dt. And it was shown that da/dt for 1% Cr-Mo V steel under the static condition(R=1) was 1.16 times faster than the case under cyclic loading(R=0), and for 12% Cr steel, 1.43 times.