• Title/Summary/Keyword: Section Factor

Search Result 1,052, Processing Time 0.026 seconds

An Experimental Study on the dynamic behavior of 4-Span Cable-Stayed Bridge with ${\pi}$-Type Girder (${\pi}$형 거더를 가진 4경간 사장교의 동적거동에 관한 실험적 연구)

  • Cho, Jae-Young;Kim, Young-Min;Lee, Hak-Eun;Yoon, Ki-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.15-24
    • /
    • 2004
  • Generally, a ${\pi}$-type girder composed of two I-type girders is known to have a significant disadvantage in wind resistance design because of aerodynamic instability. A representative bridge for this girder was Tacoma Narrows Bridge. Since Tacoma Narrows Bridge had very low stiffness of the bridge structure and its cross-section shape had aerodynamic instability, the bridge collapsed after severe torsion and vibration events in 19m/s wind speed. Aerodynamic vibration can be avoided by enhancing structural stiffness and damping factor and conducting a study of cross-section shapes. This study shows the angle of attack for the four-span cable stayed bridge having ${\pi}$-type cross-section and describes the aerodynamic characteristics of the changed cross-section with aerodynamic vibration damping additions, by carrying out two-dimension vibration tests. As a result of uniform flow and turbulent flow, the study shows that because the basic ${\pi}$-type cross-section alone can have efficient wind resistant stability, there is no need to have additional aerodynamic damping equipment. Since this four 230m-main-span bridge has a large frequency and also has a big stiffness compared to other bridges containing a similar cross-section, it has aerodynamic stability under the design wind speed.

A study on damage mechanism of transition section in cut and cover tunnel using 3 dimensional numerical analysis (3차원 수치해석을 통한 개착터널내 단면변화구간의 손상미케니즘 연구)

  • Park, Jae-Young;Son, Jeong-Hun;Park, Kwang-Lim;Oh, Young-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.6
    • /
    • pp.653-666
    • /
    • 2012
  • This study made progress about Demage Mechanism of Transition Section in Cut and Cover Tunnel. For this study, Inspection and test was carried out about Transition Section. After this process, Numerical Analysis was accomplished by 2D, 3D. A result of inspection and test, It couldn't find the reason why the upper slab Demage was detected. So 2D Numerical Analysis was conducted. It was analyzed that the Safety Factor(1.0) was satisfied in 2D. But, the result of 3D Numerical Analysis, The reason was found that the Demage on upper slab was caused by moment change. The Moment was changed by column interval transition. For Retrofitting, Column was added under slab in tunnel. It was found that the addition column decreased upper slab deformation. After this study, It could be find that are important 3D Numerical Analysis as well as 2D Numerical Analysis in case of Transition Section. This Study can help developing construction and maintenance about Tunnel. Finally, It's going to study Retrofitting plans which have minimum influence of Transition Section in Cut and Cover Tunnel.

Numerical Analysis on Flow and Bed Change Characteristics by Discharge Variations at the Confluence of Nakdong and Geumho Rivers (낙동강과 금호강 합류부 구간에서 유입유량에 따른 흐름 및 하상변동 특성 변화에 관한 수치모의 연구)

  • Jang, Eun-Kyung;Ji, Un
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.659-667
    • /
    • 2017
  • This study analyzes the changes in the flow characteristics due to the difference in inflow discharges from the main channel and tributary at the confluence of the Nakdong and Geumho Rivers. The analysis was done using a two-dimensional numerical method. The study site has complicated flow patterns because of the discharge variation from the main stream and tributary. The study section has a meandering main channel, and the hydraulic characteristics cannot be defined with simple conditions such as the confluence angle of the channels or the ratio of the channel widths. An actual flood event in 2012 was applied in the numerical simulation. The maximum velocity occurred in the meandering section after passing the confluence, where a rapid change was expected. A high velocity and large bed change in this section were observed in the simulation results. The variation of discharges from the main channel and tributary was a more dominant factor in the flow and bed changes for the normal flow conditions than the flood event. This indicates that countermeasures for channel stabilization should be considered in the meandering section downstream of the confluence section, and countermeasures for the study section should be investigated.

A Study on TRANSYT Model-embedded Parameters (TRANSYT 모델의 내재 모개변수에 관한 연구)

  • 도철웅
    • Journal of Korean Society of Transportation
    • /
    • v.6 no.1
    • /
    • pp.55-64
    • /
    • 1988
  • Prior to using any computer model, the program-embedded palameters showing significant differences from real world should be calibrated. This is especially true when the model is expected to be used fro various roadway and traffic condition. The calibration of TRANSYT model was conducted for the parameters of start-up delay, and lag, stop penalty(K), platoon dispersion factor, and saturation flow rate. The values of the parameters were obtained by theoretical methods from actual field measurements for discharging and arrival pattern. The sites elected for the study was an intersection of Dongil-Ro and Hwarang-Ro, and a 334 meter downstrean section from the intersection stop line on westbound Hwarang-Ro. The study results showed that the start-up delay was 2.6 sec, end lag was 1.0 sec, saturation flow rate was 2287 pcphgpl, platoon dispersion factor was 0.2-03, and stop penalty(K) was 32. However, since these parameters re apt to depend on traffic and roadway condition, it is doubtful whether the obtained values will be applicable to the area-wide situation other than this particular site.

  • PDF

Vibration Analysis of Damped Sandwich Beam Using Finite Element Method (유한요소법을 이용한 샌드위치형 감쇠 보구조물의 진동해석)

  • Seo, Young-Soo;Jeong, Weui-Bong;Shin, Joon-Yub
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.978-981
    • /
    • 2005
  • The vibration analysis of damped sandwich beam is conducted using finite element method. The equation of motion presented by Mead and Markus is used to formulate FEM. Also as the thickness of the core in the damped sandwich beam goes to zero, conventional beam theory based on the transformed-section method and the equation of Mead and Markus are compared. According to the change of thickness and loss factor of the core, the forced frequency response of beam is calculated and discussed. And then using the half-power band width method, the damping ratio of each mode is calculated and discussed about each case.

  • PDF

A Study on Collection Efficiency of Compact and Small Size Air-Cleaning Electrostatic Precipitator (공기정화용 소형 전기집진장치의 집진효율에 관한 연구)

  • Lee, S.H.;Yum, M.O.;Kang, K.O.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.1
    • /
    • pp.84-89
    • /
    • 1997
  • Recentely, a compact and small size air-cleaning Electrostatic Precipitator(ESP) is needed to develop for air conditioning devices. From Deutsch formula for ESP efficiency, collection efficiency is affected not only the structure of collection section but also the charge rate of dust. In terms of collection area, the most useful type is a scroll type ESP. In this work, we investigated experimentally aptimum design factor of scroll type ESP by application of Taguchi method. And we developed the scroll type ESP by using optimal condition of control factor.

  • PDF

Kansei Comparison of Form-ratio by Factor Analysis

  • Nishino, Tatsuo;Nagamachi, Mitsuo
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.248-252
    • /
    • 2000
  • Form-ratio means the ratio of height/Width/Depth in 3-dimensions. The golden ratio or golden section is included as one of the form-ratio. We conducted two kinds of kansei experiments of cubic model and refrigerator varied from 1:1:1 to 1:1:3.66 on the scale of x:y:z. The subjects evaluate the form-ratios of 3-dimensional cubes and virtual products with SD-scale Kansei words(feelings and images). We applied the factor analysis to identify semantic space in cube model and virtual products. Finally, we compared with kansei structure of cube model and virtual product.

  • PDF

Effects of Excavation Methods on Tunnel Deformation Behavior using Finite Element Analysis (굴착공법이 터널변위 거동에 미치는 영향-유한요소해석)

  • Yoo, Chung-Sik;Kim, Joo-Mi;Kim, Sun-Bin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.199-207
    • /
    • 2006
  • Before getting to the actual study of the load distribution factor in various excavating methods, this research is preliminarily focused on the comparison of two different excavation methods, CD cut method and Ringcut method. Especially, the purpose of this research is to study the behavioral mechanism of two tunnels which share the same construction environment but different excavating method. Two numerical analysis models with the same tunnel section and material properties are compared in this study, and they are analyzed by 3D Finite Element Analysis. In each model, face stability, crown displacement, ground settlement, and shotcrete-lining stress are computed. Thus, the general behavior of CD cut method and Ringcut method are studied, and it certified what should be considered for the calculation of the load distribution factor.

  • PDF

A Study for the Pressure Drop of Static Mixers (스태틱 믹서의 압력손실에 대한 연구)

  • 양희천;박상규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.299-304
    • /
    • 2003
  • Static mixer consists of a straight pipe of circular cross section into which individual elements are inserted to cut, fold, twist and re-combine the mixing fluid. The number of elements and their shape required in any application depend on the complexity of the mixing process. The objectives of this study are to develop a new static mixer and to perform the experimental investigation of pressure drop in order to evaluate the performance of the new one. The mixing fluid used is Glycerin. The pressure drop is measured using a hydraulic manometer and the correlation of Z-factor is suggested as a function of Re. The Z-factors of SSC and YNU mixer are about 40% lower than and 4% higher than that of the Sulzer one.

SIF of cracks of the holes in the Bolt-joint structure (Bolt 연결 구조물의 구멍주위 균열의 응력확대계수 계산)

  • 심동철;이기수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.727-730
    • /
    • 2001
  • In many structures a common method of construction is to make use of bolted or riveted joints. With this type of joint the load is transmitted through a pin from one section of the structure to another. Fatigue cracks often start from the edges of holes, due to local stress concentration. In order to predict the fatigue crack growth, the stress intensity factor K for hole-edge cracks should be available. In this paper the stress intensity factors are computed for cracks in bolt-joint region considering the contact condition.

  • PDF