• Title/Summary/Keyword: Secondary-Joint

Search Result 294, Processing Time 0.023 seconds

Treatment of Acromioclavicular Joint Injury (견봉 쇄골인대 손상의 치료)

  • Noh, Kyu-Cheol;Lee, Jae-Won;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.1
    • /
    • pp.58-68
    • /
    • 2011
  • Acromioclavicular (AC) joint dislocations are common injuries in active individuals secondary to direct force on the lateral aspect of the adducted shoulder. Complete disruption of the acromioclavicular and coracoclavicular (CC) ligaments may occur, depending on the magnitude of the insulting force. Most of these injuries are successfully treated without surgery. However, for the treatment of cases in which surgical management is warranted, there are more than 100 surgical techniques available without a gold standard technique. We review the anatomy of the acromioclavicular joint, the diagnosis of disorders of this joint, and the different treatment options in this article.

  • PDF

Microprocessor Implementation of Secondary PID Controller for Motion of SCARA Type Robot (스카라형 로보트의 동작에 관한 2차 PID 제어기의 마이크로프로세서 구현)

  • Park, Il-Young;Hong, Suk-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.401-404
    • /
    • 1991
  • In this paper, the controllers for the motion of the 2-joint manipulator design two stages: (1) a primary controller that under ideal conditions makes the end-effector track the desired trajectory: (2) a secondary controller that compensates for undesirable deviations of the motion from the disired trajectory caused by external and/or internal disturbances. The secondary contoller is applied to PID control algorithm. and the controllers is actually designed using IBM-PC/AT and 8096 single chip microprocessor.

  • PDF

Construction of an Oil Pump Rotor Production Line with High Productivity

  • Akiyama, Kazunari
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1278-1279
    • /
    • 2006
  • New product line with additional secondary operation of oil pump rotor was built in necessity of increasing capacity. This new line includes steam treatment process after sizing. The new line achieved 1.6 times higher performance compared with a conventional line.

  • PDF

Nonunion in Bilateral Ball and Socket Ankle Joint (양측성 절구공이 족관절에서의 불유합 -1예 보고-)

  • Park, Hong-Gi;Lee, Kyung-Chan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.231-233
    • /
    • 2005
  • Ball-and-socket deformity of the ankle joint is a rare entity that is usually associated with inequality of leg length, fibular hyperplasia, coalition of the ankle, and ray deficiency. Etiology is unknown, congenital itself or secondary to congenital conditions in the ankle. Nonunion of medial malleolar is rare in bilateral ball and socket ankle joint without lower leg deformity. We report upon this case, and include brief reviwe of the literature.

  • PDF

Chronic dislocation of temporomandibular joint persisting for 6 months: a case report

  • Kim, Chul-Hwan;Kim, Dae-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.5
    • /
    • pp.305-309
    • /
    • 2012
  • Temporomandibular joint (TMJ) subluxation and dislocation are uncommon but very unpleasant and distressing conditions to patients. Subluxation of the TMJ is an excessively abnormal condylar excursion secondary to flaccidity and laxity of the capsule. When the condyle head excurses anterior to the eminence upon wide opening, it can return to the fossa by self-manipulation or non-surgical conservative reduction. Surgery is recommended if a complete dislocation, so-called open lock, occurs as a chronic or recurrent protracted condition that cannot be reduced voluntarily. A range of surgical procedures can be performed to limit condylar hypermobility inclusing soft tissue tethering, creation of articular obstacles, removal of mechanical blockade and augmentation of articular eminence using different kinds of grafts. In the present case, a 74-year-old woman was diagnosed with a chronic TMJ dislocation that had lasted for 6 months. Bilateral condylectomy was performed and the post-operative results were good without functional limitations or recurrence.

Application of External Skeletal Fixations to Correct the Growth Deformities in a Dog (개에서 외골격 고정을 이용한 성장 기형의 교정)

  • 김영삼;변예은;윤성진;오태훈;박옥지;임지혜;최민철;권오경
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.410-412
    • /
    • 2003
  • A male, 11-month-old, Shih-tzu dog weighing 5.2kg showing knuckling secondary to severe cranial bowing of left antebrachium with valgus deformity of the carpus was presented to the Veterinary Medicine Teaching Hospital of Seoul National University. Radiographic findings were a premature closure of the distal ulnar physis, a cranial bowing of the radius, subluxation of the elbow joint, and degenerative changes in the carpal joint. The patient was treated by performing an oblique osteotomy of the radius and ulna, followed by application of External Skeletal Fixations. At 18 weeks postoperatively, the radius was healed. An incongruency of the elbow joint and radial angular deformity was corrected.

Arthroscopic Findings of the Canine Stifle Joint (정상견 무릎의 관절경 검사소견)

  • 정순욱;정월순
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.300-308
    • /
    • 1999
  • Arthroscopy is a valuable diagnostic and operative tool in equine and human orthopedics. The arthroscope is a difficult instrument to use and requires patience, practice, and persistence in order to obtain good results. This technique was found to be less traumatic than arthrotomy, invasiveness, rapid recovery and the feasibility of surgically correcting many arthropathies. The use of the arthroscope in the dog provides a new dimension in the study and diagnosis of joint derangements. The purpose of this report is to introduce the use of the arthroscope in the dog-more specifically, in the stifle of the dog. A diameter 2.7 mm fore-oblique viewing arthroscope, cold light source, video and video printer are used. With the fore-oblique viewing type it is possible to view directly as well as slightly to the side and the range of viewing can be increased by rotating the arthroscope around the object The scope is connected with a cold light source by means of a fiber-optic light guide. The stifle joint was flexed to 20~30$^{\circ}$. The joint were lavaged with lactated Ringer's solution during arthroscopic examination. Arthroscopy of the stifle was performed prior to arthrotomy in 1 dead dog and 4 healthy dogs, and other 3 dogs was performed only arthroscopic examination. In this study only the conventional approaches were used and in most cases it was possible to view all the intra-articular structures via the lateral infrapatellar approach. In the stifle joint, endoscopic observation was performed to find lateral femoral condyle, patella, medial femoral condyle, trochlear groove, tibia, fat, cranial cruciate ligament, caudal cruciate ligament lateral meniscus, tendon of long digital extensor muscle, medial meniscus, and medial collateral ligament Post-arthroscopic examination, the lameness had disappeared within 12~24 hours. Pain and swelling in the stifle joint had disappeared within 24~36 hours. Post-arthroscopic secondary infection was never encountered in the dogs. In conclusion, arthroscopic insertion technique in canine stifle joint using a diameter 2.7 mm 30$^{\circ}$ arthroscope was established and arthroscopical views of all anatomical structures in the normal stilfe joint were obtained through lateral infrapatellar portal.

  • PDF

Arthroscopic Treatment of Stiff Elbow (주관절 관절경을 이용한 구축의 치료)

  • Rhee Kwang-Jin;Kim Kyung-Cheon;Hong Chang-Hwa;Song Ho-Sup;Shin Hyun-Dae
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.1
    • /
    • pp.14-18
    • /
    • 2005
  • Purpose: Limitation of motion of the elbow joint due to stiffness affect on life quality of the patients. So contracture of the elbow should be treated as soon as possible. Among the many treatment modalities, we described the result of arthroscopic treatment. Materials and Methods: From Mar. 2000 to Mar. 2003, 40 patients, who received the arthroscopic treatment by author for contracted elbow, were the subjects. We estimated the range of motion (ROM) of elbow joint before and after surgery by goniometer. The clinical result was evaluated by Severance elbow scoring system. The final ROM was evaluated at the point of no further increasement of joint motion. Male ware 30 cases, female ware 7 cases, average 42.6 years old and mean follow up period were 31 months. During arthroscopic treatment we had done release of the joint capsule or resection, synovectomy, removal of loose bodies. We used traditional portals. Results: The avarage preoperative ROM of elbow joint was 72.5 degree(range, 5 - 132 degree) and the increasement of ROM was totally 49.3 degree in flexion 26.5 degree and extension 22.8 degree. There was no other complication. Conclusion: Arthroscopic treatment for contracted elbow permit early joint ROM and it decrease the secondary injury to the elbow joint. Also there are few complications. It is thought to be a good treatment modality in contracted elbow joint.

Effects of Different Shielding Gases in Laser Welding of Secondary Ni battery with Multi-thin Plates (이차전지용 니켈 다층 박판의 레이저 용접 보호가스의 영향)

  • You, Young-Tae;Lee, Ka-Ram;Kim, Jin-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.329-337
    • /
    • 2016
  • The demand for the eco-friendly vehicles is skyrocketing because of the increasing $CO_2$ emissions and global warming. In the industrial field, the battery process, a core part of an eco-friendly vehicle, is drawing increased attention; its weight lightening as well as high energy density are becoming increasingly important. In this study, pure Ni plates that were used as the battery pole plate were welded using the laser. The lab joint welding was conducted on ten pure Ni plates at a laser power of 1900 W and a feed speed of 2.8-3.4 m/min. As observed in the experiment, a faster feed speed reduced the bead width, but the laser did not penetrate all ten specimen plates. In addition, pores were trapped when protective gas was used, but they were not trapped when the welding was conducted in atmospheric condition.

LIQUID FLOW AND EVAPORATION SIMULATION OF CRYOGENIC FLUID IN THE WALL OF CRYOGENIC FLUID CARGO CONTAINMENT SYSTEM (극저온 유체 화물창 방벽 내의 액체유동 및 기화 시뮬레이션)

  • Park, Bum-Jin;Lee, Hee-Bum;Rhee, Shin-Hyung;Bae, Jun-Hong;Lee, Kyung-Won;Jeong, Wang-Jo;An, Sang-Jun
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.9-18
    • /
    • 2009
  • The cargo containment system (CCS) for ships carrying cryogenic fluid consists of at least two levels of barriers and insulation layers. It is because, even though there is a small amount of leak through the primary barrier, the liquid tight secondary barrier blocks further leakage of the cryogenic fluid. However, once the secondary barrier is damaged, it is highly possible that the leaked cryogenic fluid flows through the flat joint made of glass wool and reaches the inner hull of the ship. The primary objective of the present study is to investigate the influence of the damage extent in the secondary barrier on the amount of leaked cryogenic fluid reaching the inner hull and the temperature distribution there. Simulation results using a computational fluid dynamics tool were compared with the experimental data for the leaked cryogenic fluid flow and evaporation in the secondary insulation layer. The experimental and computational results suggest that, unless there is a massive leak, the cryogenic fluid mostly evaporates in the insulation layer and does not reach the inner hull in the state of liquid.