• 제목/요약/키워드: Secondary Sources

검색결과 451건 처리시간 0.031초

Current Collectors for Flexible Lithium Ion Batteries: A Review of Materials

  • Kim, Sang Woo;Cho, Kuk Young
    • Journal of Electrochemical Science and Technology
    • /
    • 제6권1호
    • /
    • pp.1-6
    • /
    • 2015
  • With increasing interest in flexible electronic devices and wearable appliances, flexible lithium ion batteries are the most attractive candidates for flexible energy sources. During the last decade, many different kinds of flexible batteries have been reported. Although research of flexible lithium ion batteries is in its earlier stages, we have found that developing components that satisfy performance conditions under external deformation stress is a critical key to the success of flexible energy sources. Among the major components of the lithium ion battery, electrodes, which are connected to the current collectors, are gaining the most attention owing to their rigid and brittle character. In this mini review, we discuss candidate materials for current collectors and the previous strategies implemented for flexible electrode fabrication.

'Brine Management through brine mining of trace metals' for developing Secondary sources of nuclear fuel

  • T.L. Prasad
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.674-680
    • /
    • 2023
  • The brine and seawater are important and largely untapped sources of critical trace metals and elements. The coupling of selective recovery of trace metals from seawater/brine with desalination plants gives an added advantage of energy credits to desalination plants and as well as reduce the cost of desalinated water. In this paper, status review on recovery of important trace metals and other alkali metals from seawater is presented. The potential of Indian desalination plants for recovery of trace metals, based on recovery ratio of 0.35 is also highlighted. Studies carried out by the process based on adsorption using Radiation Induced Grafted (RIG) polymeric adsorbents and then fractional elutions are presented. The fouling factors due to bio fouling and dirt fouling have been estimated for various locations of interest through field trails. The pay loader in the form of compact Contactor Assembly with minimum pressure drop, for loading specially designed radiation grafted sorbent in leaflet form has been briefed, as required for plant scale facility. The typical conceptual process design details of farm assembly of project CRUDE are described.

봄철과 가을철 용인지역 입자상 물질의 이온 농도 (Ion Concentrations of Particulate Matter in Yongin in Spring and Fall)

  • 원수란;최용주;김아롱;최순호;김영성
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.265-275
    • /
    • 2010
  • Mass and ion concentrations of $PM_{10}$ and $PM_{2.5}$ were measured in Yongin, downwind of the Seoul metropolitan area. Twenty-four hour average samples were collected daily for a month or so in spring and fall of both 2007 and 2008. Asian dust occurred twice in each period except in the fall of 2007. During the Asian dust period, nitrate in fine particles decreased since large amount of cations in coarse particles of Asian dust absorbed it. In spring 2008, sulfate as well as ammonium also increased in coarse particles. In spite of occasional Asian dust events, the influence of secondary formation was dominant over the period. Excessive ammonium over sulfate was enough to neutralize nitrate as well. High correlation coefficients between $K^+$ and sulfate, nitrate, and ammonium indicate a close relationship between secondary formation and biomass burning. Biomass burning and open burning are considered to be important sources of chloride.

부산지역 오존 및 이산화질소 농도의 공간분포해석에 따른 대기오염측정망 배치연구 (A Study on Allocation of Air Pollution Monitoring Network by Spatial Distribution Analysis of Ozone and Nitrogen Dioxide Concentrations in Busan)

  • 유은철;박옥현
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.583-591
    • /
    • 2004
  • In this study, methodologies for the rational organization of air pollution monitoring network were examined by understanding the characteristics of temporal and spatial distribution of secondary air pollution, whose significance would increase hereafter. The data on $O_3$ and $NO_2$ concentrations during high ozone period in 1998~1999 recorded at the nine air pollution monitoring station in Busan were analysed using principal component analysis (PCA) and cumulative semivariogram. It was found that the ozone concentration was deeply associated with the daily emission characteristics or the $O_3$ precusors, and nitrogen dioxide concentration largely depends on the emission strength of regional sources. According to the spatial distribution analysis of ozone and nitrogen dioxide in Busan using cumulative semivariograms, the number of monitoring stations for the secondary air pollution can be reduced in east-west direction, but reinforced in north-south direction to explain the spacial variability. More scientific and rational relocation of air pollution monitoring network in Busan would be needed to investigate pollution status accurately and to plan and implement the pollution reduction policies effectively.

경희궁 궁원구성의 특징 (Configuration of the Royal Garden in Gyeonghuigung Palace)

  • 백지성;김민선;조태동
    • 한국환경과학회지
    • /
    • 제25권12호
    • /
    • pp.1673-1688
    • /
    • 2016
  • Gyeonghuigung palace is an important site as it was the secondary palace in Hanyang from the $17^{th}$ century to the mid-$19^{th}$ century. Its original state was lost because a number of buildings were damaged and the palace area was reduced. The entire palace can be seen only in "Seogwoldoan" a drawing of the western palace. With "Seogwoldoan" to show the complete configuration of Gyeonghuigung palace in detail as the main data and other relevant data used as supplementary sources, the aim of this work was to identify the figurative features around the plantings and the space configuration of the royal garden in Gyeonghuigung palace. The space configuration observed in the royal gardens in Gyeonghuigung palace deviated from the norms and strict systems of royal palaces. The free and uninhibited configuration of the royal garden was allowed in Gyeonghuigung palace because it was built as a secondary palace in a lower hierarchy. Furthermore, a royal garden characterized by unique and unlimited planting was created, with several spaces acting as both royal garden and rear garden as the rear gardens could not be separately configured due to the narrow space of Gyeonghuigung palace.

Strong wind climatic zones in South Africa

  • Kruger, A.C.;Goliger, A.M.;Retief, J.V.;Sekele, S.
    • Wind and Structures
    • /
    • 제13권1호
    • /
    • pp.37-55
    • /
    • 2010
  • In this paper South Africa is divided into strong wind climate zones, which indicate the main sources of annual maximum wind gusts. By the analysis of wind gust data of 94 weather stations, which had continuous climate time series of 10 years or longer, six sources, or strong-wind producing mechanisms, could be identified and zoned accordingly. The two primary causes of strong wind gusts are thunderstorm activity and extratropical low pressure systems, which are associated with the passage of cold fronts over the southern African subcontinent. Over the eastern and central interior of South Africa annual maximum wind gusts are usually caused by thunderstorm gust fronts during summer, while in the western and southern interior extratropical cyclones play the most dominant role. Along the coast and adjacent interior annual extreme gusts are usually caused by extratropical cyclones. Four secondary sources of strong winds are the ridging of the quasi-stationary Atlantic and Indian Ocean high pressure systems over the subcontinent, surface troughs to the west in the interior with strong ridging from the east, convergence from the interior towards isolated low pressure systems or deep coastal low pressure systems, and deep surface troughs on the West Coast.

KVN SOURCE-FREQUENCY PHASE-REFERENCING OBSERVATION OF 3C 66A AND 3C 66B

  • ZHAO, GUANG-YAO;JUNG, TAEHYUN;DODSON, RICHARD;RIOJA, MARIA;SOHN, BONG WON
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.629-631
    • /
    • 2015
  • In this proceedings, preliminary results of the KVN Source-Frequency Phase-Referencing (SFPR) observation of 3C 66A and 3C 66B are presented. The motivation of this work is to measure the core-shift of these 2 sources and study the temporal evolution of the jet opacity. Two more sources were observed as secondary reference calibrators and each source was observed at 22, 43, and 86 GHz simultaneously. Our preliminary results show that after using the observations at the lower frequency to calibrate those at the higher frequency of the same source, the residual visibility phases for each source at the higher frequencies became more aligned, and the coherence time became much longer; also, the residual phases for different sources, within 10 degrees angular separations, follow similar trends. After reference to the nearby calibrator, the SFPRed maps were obtained as well as the astrometric measurements, i.e. the combined coreshift. The measurements were found to be affected by structural blending effects because of the large beamsize of KVN, but this can be corrected with higher resolution maps (e.g. KAVA maps).

우리나라 미세플라스틱의 발생잠재량 추정 - 1차 배출원 중심으로 - (Estimation of Microplastics Emission Potential in South Korea - For Primary Source -)

  • 이혜성;김용진
    • 한국해양학회지:바다
    • /
    • 제22권3호
    • /
    • pp.135-149
    • /
    • 2017
  • 미세플라스틱은 5 mm 미만의 플라스틱 조각으로서 의도적으로 제조한 1차 미세플라스틱과 물리 화학적 파쇄나 분해에 의해 만들어진 2차 미세플라스틱으로 나눌 수 있다. 본 연구에서는 인간의 활동으로 인해 미세해진 플라스틱을 발생시키는 배출원을 미세플라스틱의 1차 배출원으로 정의했다. 본 연구에서 미세플라스틱의 1차 배출원을 문헌을 이용하여 정리하고, 각 배출원에서의 발생잠재량을 추정하고자 하였다. 그 결과, 6만 3천~21만 6천 ton/year의 미세플라스틱이 환경으로 유입되는 것으로 나타났다. 그중 선박수송, 타이어분진, 세탁에 의한 배출이 큰 비중을 차지하였다.

The Effectiveness of Financial Sources for Climate Change in Vietnam

  • NGUYEN, Thi Nhung;NGUYEN, Minh Hoa;VU, Thi Phuong Anh;DO, Thi Hoang Anh
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제10권1호
    • /
    • pp.189-199
    • /
    • 2023
  • This research aims to give information about the current situation of five financial sources for climate change in Vietnam, including (i) the State budget used by ministries; (ii) the State budget used by provinces; (iii) Bilateral funds; (iv) Multilateral funds; and (v) Private funds, and then classify them in line with the effectiveness. The working paper's secondary data on spending on CC-related activities, collected from reports of six ministries and 29 provinces, show that the State budget has been crucial in subsidizing CC-related activities in Vietnam. Moreover, domestic investment has accounted for a major part of the total expenditure of ministries and provinces for climate change. In addition, by using primary data collected from surveys sent to twelve experts from 5 groups, such as researchers, practical experts, managers of private funding organizations (such as banks and enterprises), managers of international funding organizations and beneficiaries, and then analyzing the data through the AHP method, the study shows that all climate finance sources in Vietnam are still not very effective. However, private sector funds are considered the most effective financial source for responding to climate change.

실내외 압력 차에 따른 단창과 이중창의 틈새로 침투된 간접흡연의 입자 크기 분포 특성 (Characterization of Particle Size Distribution of Infiltrated Secondhand Smoke through the Gap in a Single Glazed and a Secondary Glazed Window by Indoor and Outdoor Pressure Differences)

  • 김정훈;이기영
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.360-369
    • /
    • 2018
  • Objectives: Outdoor tobacco smoke can penetrate into the indoor environment through cracks in the building envelope. This study aimed to characterize the particle size distribution of infiltrated secondhand smoke (SHS) through the gap in a single glazed and a secondary glazed window according to pressure differences in a chamber. Methods: Two polyvinyl chloride sliding windows were evaluated for infiltration, one with a glazed window and the other with a secondary glazed window. Each window was mounted and sealed in a polycarbonate chamber. The air in the chamber was discharged to the outside to establish pressure differences in the chamber (${\Delta}P$). Outdoor smoking sources were simulated at a one-meter distance from the window side of the chamber. The particle size distribution of the infiltrated SHS was measured in the chamber using a portable aerosol spectrometer. The particle size distribution of SHS inside the chamber was normalized by the outdoor peak for fine particles. Results: The particle size distribution of SHS inside the chamber was similar regardless of window type and ${\Delta}P$. It peaked at $0.2-0.3{\mu}m$. Increases in particulate matter (PM) concentrations from SHS infiltration were higher with the glazed window than with the secondary glazed window. PM concentrations of less than $1{\mu}m$ increased as ${\Delta}P$ was increased inside the chamber. Conclusions: The majority of infiltrated SHS particles through window gap was $0.2-0.3{\mu}m$ in size. Outdoor SHS particles infiltrated more with a glazed window than with a secondary glazed window. Particle sizes of less than $1{\mu}m$ were associated with ${\Delta}P$. These findings can be a reference for further research on the measurement of infiltrated SHS in buildings.