• Title/Summary/Keyword: Secondary Pipe

Search Result 126, Processing Time 0.029 seconds

Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes (상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구)

  • Seo, Jeewon;Lee, Gyusang;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.

A Comparison between Korean and English News Editorials with Focus on U.S.-North Korea Summit Based on Expressive Language (언어표현 기반의 북미 정상회담에 관한 한미 신문사설의 비교)

  • Noh, Bokyung;Ban, Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.125-130
    • /
    • 2019
  • This research is about alternative measure of main components for sprinkler system like automatic wet pipe sprinkler system, dry pipe sprinkler system, pre-action sprinkler system, vacuum sprinkler system, deluge sprinkler system, and so on. By replacing the alarm check valve, dry valve, pre-operated valve, and deluge open valve with a solenoid valve, it be can be simplifed the various processes of the manufacturing process into one process, it creates an environment in which one standardized product can be produced simultaneously on a single machine. Therefore, it could improve the price competitiveness of products, reduce the maintenance cost, and help the adaptability of new sprinkler systems in the future. There is a benefit when it comes to apply to sprinkler system. Only replace the valve which is used to control primary and secondary valve such as wet, dry, pre operated, vacuum, deluge system valve. Other components such as retarding chambers, automatic air compressors, accelerators or adjusters, supervisory panels, vacuum pumps, and manual starters can be used as they are, so they can be easily applied to existing sprinkler system. It is needed to legal and institutional study for solenoid valve applied sprinkler system to commercialize.

An Overview of Geoenvironmental Implications of Mineral Deposits in Korea (한반도 광상 성인유형에 따른 환경 특성)

  • 최선규;박상준;이평구;김창성
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.1-19
    • /
    • 2004
  • Metallic deposits in Korea have a variety of genetic types such as hydrothermal veins, skarns, hydrothermal replacement and alaskite deposits and so on. Geological, mineralogical and geochemical features including host rock, wall-rock alteration, ore and gangue mineralogy, mineral texture and secondary mineralogy related to weathering process control the environmental signatures of mining areas. The environmental signatures of metallic deposits closed from early 1970s to late 1990s in Korea show complicate geochemistry and mineralogy due to step weathering of primary and secondary minerals such as oxidation-precipitation-remobilization. The potentiality of low pH and high heavy metal Concentration s from acid mine drainage is great in base-metal deposits associated with polymetallic mineralization, breccia-pipe type and Cretaceous hydrothermal Au veins with the amount of pyrite whereas skam, hydrothermal replacement, hydrothermal Cu and Au-Ag vein deposits are in low contamination possibility. The geoenvironmental models reflecting the various geologic features closely relate to disuibution of sulfides and carbonates and their ratios and finally effect on characteristics of environmental signatures such as heavy metal species and their concentrations in acid mine drainage.

Supplementation of Flow Accelerated Corrosion Prediction Program Using Numerical Analysis Technique (수치해석 기법을 활용한 FAC 예측 프로그램 보완)

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Park, Won;Oh, Dong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.437-442
    • /
    • 2010
  • Flow-accelerated corrosion (FAC) leads to thinning of steel pipe walls that are exposed to flowing water or wet steam. From experience, it is seen that FAC damage to piping at fossil and nuclear plants can result in outages that require expensive repairs and can affect plant reliability and safety. CHECWORKS have been utilized in domestic nuclear plants as a predictive tool to assist FAC engineers in planning inspections and evaluating the inspection data so that piping failures caused by FAC can be prevented. However, CHECWORKS may be occasionally ignore local susceptible portions when predicting FAC damage in a group of pipelines after constructing a database for all the secondary side piping in nuclear plants. This paper describes the methodologies that can complement CHECWORKS and the verifications of CHECWORKS prediction results using numerical analysis. FAC susceptible locations determined using CHECWORKS for two pipeline groups of a nuclear plant was compared with determined using the numerical-analysis-based FLUENT.

Impact of Media Type and Various Operating Parameters on Nitrification in Polishing Biological Aerated Filters

  • Ha, Jeong-Hyub;Ong, Say-Kee;Surampalli, R.
    • Environmental Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.79-84
    • /
    • 2010
  • Three biological aerated filters (BAFs) composed of a PVC pipe with a diameter of 75 mm were constructed and operated at a waste-water temperature at $13^{\circ}C$. The media used for each BAF were: 5-mm gravel; 5-mm lava rock; 12.5-mm diameter by 15-mm long plastic rings, all with a media depth of 1.7 m. The feedwater, which simulated the effluent of aerated lagoons, had influent soluble chemical oxygen demand (sCOD) and ammonia concentrations of approximately 50 and 25 mg/L, respectively. For a hydraulic retention time (HRT) of two hours without recirculation, ammonia percent removals were 98.5, 98.9, and 97.8%, for the gravel, lava rock, and plastic rings, respectively. By increasing the effluent recirculation from 100 to 200% for an HRT of one hour, respective ammonia removals improved from 90.1 to 96, 76.5 to 90, and 65.3 to 79.5% for gravel, lava rock, and plastic rings. Based on the ammonia and sCOD loadings for different HRTs, the estimated maximum ammonia loading was approximately 0.6 kg $NH_3-N/m^3$-day for the three BAFs of different media types. The zero-order biotransformation rates for the BAF with gravel were found to be higher than the lava rock and plastic ring media. The results ultimately showed that BAF can be used as an add-on system to aerated lagoons or as a secondary treatment unit to meet ammonia discharge limits.

Removal of COD and T-N caused by ETA from Nuclear Power Plant Wastewater using 3D Packed Bed Bipolar Electrode System (3D 복극충진전기분해를 이용한 원전 ETA에 의해 유발된 폐수 내 COD 및 T-N 제거)

  • Kim, Han-Ki;Jeong, Joo-Young;Shin, Ja-Won;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.409-421
    • /
    • 2012
  • Ethanolamine (ETA) is mainly used to prevent corrosion of pipe in secondary cooling system of nuclear power plant. Condensed ETA in wastewater could increase COD and T-N when it was emitted to natural water system. Compared to conventional treatments, electrochemical oxidation process using packed bed bipolar electrodes was adopted to treat COD and T-N. According to arrangement of feeder electrode, single packed bed bipolar electrode reactor and multi-paired packed bed bipolar reactor were developed and conventional zero-valent iron (ZVI) was selected as conducting bipolar electrode. Bipolar electrodes were coordinated three-dimensionally in the reactor. The experimental results showed that COD and T-N was little removed in unit system at different pH condition (pH 8 and 11) on 100V. However, in multi-paired system that applied 600V, COD was eliminated 80.85% (anode-cathode-anode, A-C-A) and 85.11% (cathode-anode-cathode, C-A-C), respectively. T-N was also removed 96.88% (A-C-A) and 90.63% (C-A-C), simultaneously. Current efficiency was estimated both single and multi-paired system. At unit bipolar packed bed reactor, current efficiency was almost zero, however in multi-paired system, current efficiency was 300~500% at A-C-A and 250~350% at C-A-C. Current efficiency was over 100% hence it was confirmed that this system is more effective than conventional electrochemical oxidation system.

A Study on the Development of Superheater Using High-Frequency Resonant Inverter for Induction Heating (유도가열용 고주파 공진형 인버터를 이용한 과열증기 발생장치 개발에 관한 연구)

  • 신대철;권혁민;김기환;김용주
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.119-125
    • /
    • 2004
  • This paper is described the indirect induction heated boiler system and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20〔KHz〕 to 50〔KHz〕. A specially designed Induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the resonant inverter. In the induction heater, it's primary heating section creates low-pressure saturated steam and secondary heating section generates heat distribution evaporating fluid from the turbulence fluid which is flowing through the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from the practical point of view.

The Implemention of RTD-l000A based on ARM Microcontroller (ARM 마이크로컨트롤러 기반 RTD-1000A의 구현)

  • Kim, Min-Ho;Hong, In-Sik
    • Journal of Internet Computing and Services
    • /
    • v.9 no.6
    • /
    • pp.117-125
    • /
    • 2008
  • With increase of concern about the Ubiquitous application, the necessity of the computer system which is miniaturized is becoming larger. The ARM processor is showing a high share from embedded system market. In this paper, ideal method for RTD-1000 controller construction and development is described using ARM microcontroller. Existing RTD-1000 measures distance of disconnection or defect of sensing casket by measuring receiving reflected wave which was sent via copper wire inside the leaking sensing rod. Using this RTD-1000, leakage and breakage of water and oil pipe can be sensed and it reports damage results to the networks. But, existing RTD-1000 wastes hardware resources much and costs a great deal to installation. Also, it needs a cooling device because the heating problem, and has some problem of the secondary memory unit such as the hard disk. So, long tenn maintenance has some problems in the outside install place. In this paper, for the resolving the problem of RTD-1000, RTD-1000A embedded system based on ARM is proposed and simulated.

  • PDF

Ground Subsidence Mechanism by Ground Water Level and Fine Contents (지하수위와 세립분 함유량에 따른 지반함몰 메커니즘)

  • Kim, JinYoung;Lee, SungYeol;Choi, ChangHo;Kang, JaeMo;Kang, KwonSoo;Jeong, HyoJin;Hong, JaeCheol;Lee, JaeSoo;Baek, WonJin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.5
    • /
    • pp.83-91
    • /
    • 2017
  • Recently, ground subsidence frequently occurs in downtown area. The major causes of the subsidence on the subsurface were the damages of the water supply and sewer pipelines and excavation works in adjacent areas, etc. Because of these various factors, it is not easy to analyze the tendency of occurrence of ground subsidence. The purpose of this study is to clarify the effect of ground subsidence by the change of the fine particle content and ground water level and to establish the ground subsidence mechanism. In this study, a model soil-box was manufactured to simulate the failure of the old sewer pipe which is one of the causes on ground subsidence. And a model test was conducted to investigate the effects of fine contents and ground water level on the cavity occurrence. From the test results, firstly the higher the ground water level, the faster the primary cavity is formed as the seepage stress increases. As a result, the secondary cavity and the ground subsidence rapidly progress due to the relaxation of the surrounding ground. The total amount of discharged soil was decreased as the fine content increased.

Assessment of Best Available Technology of Wastewater Treatment Facilities in Leather Tanning and Finishing Industry (가죽, 모피가공 및 제조시설의 폐수처리시설 BAT평가)

  • Kim, Youngnoh;Lim, Byungjin;Kwon, Osang
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.51-58
    • /
    • 2006
  • The effluent limitations for individual industry based on the best available technology economically achievable (BAT) have been required to achieve effective regulation. BAT assessment criteria that are suitable for the circumstances of Korean industry were developed in the previous study. The criteria were applied to determine the BAT for leather tanning and finishing industry. For the evaluation BAT, a subcategorization for the industry considering wastewater characteristics, source equipments, raw material and so on should be suggested. Three subcategories: A) Unharing, Chrome Tan, Retan-Wet Finish, B) Chrome Tan, Retan-Wet Finish, and C) Furskins were proposed in this study. Wastewater discharged from the each category contains high concentration of COD, chrome, nitrogen and sulfide. In particular, the concentration of nitrogen from the subcategory A is significantly greater. Twenty sites were surveyed and wastewater qualities were analyzed. Therefore, six different technologies were applied to the subcategory A for the end-of-pipe treatment technology, and a technology was used in the subcategory B and C, respectively. The technology candidates were evaluated in terms of environmental impacts, economically achievability, treatment performance and economical reasonability. As the result, the technology options for each subcategories: A) primary chemical precipitation + modified Ludzack-Ettinger process (MLE) + secondary chemical precipitation, B) chemical precipitation + typical activated-sludge process + Fenton oxidation, C) chemical precipitation + typical activated-sludge process + batch Fenton oxidation or batch activated carbon treatment were selected as the BAT, respectively.