• 제목/요약/키워드: Secondary Fuel

검색결과 323건 처리시간 0.024초

연료전지와 리튬 이차전지의 하이브리드 시스템 개발 (Development of hybrid system with fuel cell and lithium secondary battery)

  • 황상문;정은미;손동언;심태희;송하영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.143.2-143.2
    • /
    • 2010
  • Therefore, with this development assignment we'd like to develop the hybrid system combining 800W DMFC (Direct Methanol Fuel Cell) and 1.6kW of Lithium secondary battery pack which can be applied to the most common small cart. a scooter, to secure the development capability of hundreds of Watts DMFC, the high-capacity Lithium secondary battery pack, the technology of BMS (Battery Management System) and the development technology of hybrid system. DMFC, in fact, has lower energy efficiency than PEMFC (Polymer Electrolyte Membrane Fuel Cell); however, it has several advantages in terms of fuel storage and use. It is pretty easy to be stored and used without any additional colling and heating devices because of its insensitive liquid methanol to temperature. In conclusion, DMFC system is the most suitable device for small mobile vehicles.

  • PDF

2차측 배관파단에 대한 핵연료 집합체의 구조 건전성 (Structural Integrity of a Fuel Assembly for the Secondary Side Pipe Breaks)

  • ;정명조;이정배
    • 소음진동
    • /
    • 제6권6호
    • /
    • pp.827-834
    • /
    • 1996
  • 본연구에서는 핵연료집합체의 검증계획의 일환으로 2차측 배관파단의 영향을 조사하였다. 원자로노심의 상세모델을 이용한 동적해석으로 배관파단에 의한 응답을 구하였다. 파단적 누설개념의 적용으로 10인치 이상의 고에너지 배관에 대하여 양단 파단이 설계에서 배제됨에 따라 본 연구에서는 주증기관과 급수관의 파단을 가정 하였다. 핵연료 집합체의 전단력, 굽힘모우멘트, 변위 및 지지격자체의 충격하중에 대하여 자세히 고찰하였고 이들 동적해석 결과를 이용하여 핵연료집합체의 구조적 건전성을 평가하였으며 사고조건에서 2차측 배관파단이 핵연료집합체의 구조적 건전성 에 미치는 영향을 검토하였다.

  • PDF

가스터빈 연소기내 2차연료분사에 의한 연소 불안정성의 제어 (Control of Combustion Instabilities in a Gas Turbine Combustors Through Secondary Fuel Injection)

  • 전충환
    • 한국연소학회지
    • /
    • 제3권1호
    • /
    • pp.59-69
    • /
    • 1998
  • The results of study on the active control of naturally occurring combustion oscillations with a single dominant frequency in an atmospheric dump combustor are presented. Control was achieved by an oscillatory infection of secondary fuel at the dump plane. A high speed solenoid valve with a maximum frequency of 250Hz was used as the actuator and a sound level meter, located at the combustor exit, measured the pressure fluctuations which served as the feedback signal for the control loop. Instability characteristics were mapped over a range of mean mixing section velocities from 6.7 m/s-9.3 m/s and with three mixing conditions. Different fuel/air mixing conditions were investigated by introducing varying percentages of primary fuel at two locations, one at the entrance to the mixing section and one 6 mixing tube diameters upstream of the dump plane. Control studies were conducted at a mean velocity of 9.3 m/s, with an air temperature of $415^{\circ}C$, and from flame blowout to the stoichiometric condition.

  • PDF

다공 스로틀 밸브에서의 액체 연료의 2차 미립화 특성에 관한 연구 (A Study on the Secondary Atomization Characteristics of Liquid Fuel in the Perforated Throttle Valve)

  • 이창식;이기형;조병옥;오군섭
    • 한국분무공학회지
    • /
    • 제1권1호
    • /
    • pp.55-62
    • /
    • 1996
  • In a fuel injection engine, atomization of liquid fuel and mixture formation process has influenced(or affected) directly on the engine performance and pollutant emission. In this study, the characteristics of fuel spray and the behaviors of secondary atomization developed at the downstream of the valves were investigated using an image processing method. Solid and perforated valves are chosen in order to evaluate the valve performance in terns of air flow rate, valve opening angle and valve shape. Experimental results clearly indicate that the spray atomization quality can be improved by increasing the perforated rat io and the blockage rat io in the perforated valve, the characteristics of spray atomization is improved by using the perforated valve with high perforated rat io and blockage ratio.

  • PDF

연료전지기반 공동주택 에너지시스템 분석모델에 관한 기초연구 (A Preliminary Study on the Analysis Model of Energy System based on Fuel Cell for Apartment Houses)

  • 이홍철;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.396-401
    • /
    • 2003
  • In the present study, preliminary investigation were carried out by analysis of energy system(heat and electricity) based on phosphoric acid fuel-cell of 50 kW for eco-apartment houses. Analysis model were consisted of fuel cell energy system, secondary energy unit and residential building of 5 stories with 20 and 40 households. And the investigation results reviewed under load pattern of heat and electric power of the apartment houses. The results showed mismatch between the needed heat load pattern and output of fuel cell energy system. The mismatch rate were assessed about 10-180% of heat load for apartment houses with season. We found that secondary energy unit are needed in order to supply insufficient heat.

  • PDF

촉매연소기에서 2단 공급공기와 연료가 NOx 저감에 미치는 연구 (NOx Reduction with Secondary Air and Fuel in a Catalytic Combustor)

  • 정진도;이보영
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.541-549
    • /
    • 2003
  • A basic experimental study was conducted in order to find the optimum combustion control technology to decrease the thermal NO$_{x}$, by applying the catalytic combustion method with natural gas. NO$_{x}$ emission increased with increasing space velocity due to temperature rising in the furnace. In order to overcome the low resistance to high temperature, secondary air was supplied to the CST combustor. The following secondary fuel formed combustible mixture in part, which resulted in steep increase of the exiting temperature of the 2nd catalyst bed. It led to the more generator of NO$_{x}$, 30∼60% of the 1 st catalyst bed. It might be due to the potential increase of thermal NO$_{x}$.

The Effects of Secondary Fuel Injection on Combustion Oscillation

  • Shigeru Tachibana;Laurent Zimmer;Park, Gyung-Min;Takeshi Yamamoto;Ufosawa, Yoji-K;Seiji Yoshida;Kazuo Suzuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.376-379
    • /
    • 2004
  • The purpose of this work is to develop an effective active control system for combustion instabilities of premixed combustors. For the first step, the natural modes of combustion oscillation were investigated for a methane-air premixed combustor and the controls by secondary fuel injection were examined. The main premixed flame is stabilized by a swirler with orifices for secondary injection installed on the central hub. For sensing purposes, a pressure transducer and a chemiluminescence sensor were placed on the appropriate positions. The acoustic characteristics and the source of the oscillation were analyzed by those signals. To test the controllability, two methods of actuations by secondary fuel injection were examined. One is the open loop control and the other is the closed loop control. The comparison of the reduction levels of p $_{rms}$ shows that the closed loop control with a phase-shift injection performs best in this condition.ition.n.

  • PDF

초음속 엔진 모델 연소기에서의 연소불안정 및 제어 시험 기법 (Method of Test for Combustion Instability and Control at Model Combustor of Supersonic Engine)

  • 최호진;황용석;진유인;박익수;윤현걸;강상훈;이양지
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.111-115
    • /
    • 2009
  • 초음속 엔진으로부터 구성한 모델 연소기를 설계/제작하여 연소시험 중 발생하는 연소불안정을 측정하고 화염안정화 장치를 이용하여 2차 연료를 분사하는 방법으로 연소불안정을 능동제어하는 기법에 관해 연구하였다. 연소실 압력측정이나 화염의 광학적 계측을 통해 연소불안정 주파수를 검출하였고, 고속으로 운용할 수 있는 마그네틱 밸브를 구동기로 선정하여 밸브 후단 압력 및 2차 분사되는 연료의 분무의 광학적 계측을 통해 연료 변조 특성을 확인하였다.

  • PDF

가솔린엔진의 전자제어 센서파형 측정을 통한 점화2차 파형 분석에 관한 실험적 연구 (An Experimental Study on the Secondary Waveform Analysis according to Measure of Electronic Control Waveform)

  • 유종식;김철수;차경옥
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.95-100
    • /
    • 2011
  • The test was done on cars travelling at speeds of 20km/h, 60km/h and 100km/h, the performance testing mode for chassis dynamometer. In this test, the secondary waveform were measured, including those using faulty MAP sensors, oxygen sensors and spark plugs. The results from these measurements and their analysis of secondary waveform can be summarized as follows: 1) The secondary waveform measured from the faulty oxygen sensor showed a lot of noise around peak voltage and in the rising and falling sections during spark line which means that the air fuel mixture was non-homogeneous. 2) The secondary waveform from the faulty MAP sensor showed the worst shape compared to other sensors, including variation of spark line, state of air-fuel mixture and velocity of flame front. 3) The spark line time of secondary waveform using a faulty spark plug displayed the shortest and smallest energy spark line, which means that a misfire occurred.