• Title/Summary/Keyword: Secondary Flow Rate

Search Result 288, Processing Time 0.028 seconds

Modeling Fate and Transport of Organic and Nitrogen Species in Soil Aquifer Treatment-(I) Model Development and Verification (토양/대수층 처리(soil aquifer treatment)에서 유기물과 질소화합물 제거와 이송 모델링-(I) 모델 개발 및 검증)

  • Kim Jung-Woo;Kim Jeong-Kon;Cha Woo-Suk;Choi Hee-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.9-15
    • /
    • 2005
  • Soil aquifer treatment is a water reuse technology that secondary or tertiary treated wastewater is infiltrated into the aquifer in which physical and biochemical reactions occur. Major consideration in SAT is the removal and transport of DOC and nitrogen species. In this study, reaction mechanism in SAT was examined considering nitrification, denitrification and organic oxidation. In addition, SAT modeling system was developed as the reaction mechanism was applied to groundwater flow and transport model. In verification of the reaction module by 1-dimensional unsaturated soil column test, the experimental data of all of the species, ammonium, nitrate, DOC and DO, were well matched with the simulation results. In sensitivity analysis, ammonium partition coefficient, dissolved oxygen inhibition constant and biomass decay rate affect ammonium, DOC and DO concentration of effluent, respectively.

The Efficiency of VAC(Vacuum-Assisted Closure) in Non-healing Wound (하지의 난치성 창상치유에 있어 VAC(Vacuum-Assisted Closure)의 유용성)

  • Park, Jung Min;Kwon, Yong Seok;Jung, Ki Hwan;Lee, Keun Cheol;Kim, Seok Kwun;An, Won Suk
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.727-732
    • /
    • 2005
  • The treatment of wounds of the lower extremity caused by diabetes or vascular dysfunction remains a difficult problem for the plastic surgeon. The use of negative pressure in wound healing is a relatively new method to facilitate chronic wound healing by secondary healing. The use of vacuum-assisted closure(VAC) system is purposed to reduce local edema, increase regional blood flow, enhance epithelial migration, preserve a moist wound environment, reduce bacterial colonization, promote granulation tissue formation, and mechanically enhance wound closure. The VAC also can be used as a dressing for anchoring an applied split thickness skin graft. We reviewed the data from 20 consecutive patients with non-healing wound in lower extremity at Dong-A University from March 2002 to December 2004. We used the VAC in 20 patients and compared the results with the control group. In the VAC using group, mean application duration was about 3 weeks and dressing change was done every other day. The follow-up period of patients ranged from 3 months to 30 months with a mean of 17 months. The points of comparison with control group are wound size, granulation tissue proliferation rate, operation method, preoperative time, postoperative healing time, complication, and cost. With those points, we propose to approve the efficiency of the VAC in non-healing wound. As a result, the VAC used in non-healing wound decrease wound size, accelerate granulation tissue formation, do a wound closure with less invasive operation method, make less postoperative complication, can make operation time shorter. Therefore it is cost effect. Our results demonstrate the usefulness of VAC as an adjunct in management of chronic wounds with other extrinsic factors.

The Removal of Si3N4 Particles from the Wafer Surface Using Supercritical Carbon Dioxide Cleaning (웨이퍼 표면의 Si3N4 파티클 제거를 위한 초임계 이산화탄소 세정)

  • Kim, Yong Hun;Choi, Hae Won;Kang, Ki Moon;Karakin, Anton;Lim, Kwon Teak
    • Clean Technology
    • /
    • v.24 no.3
    • /
    • pp.157-165
    • /
    • 2018
  • In this study, the removal of $Si_3N_4$ particles from the surface of a silicon wafer was investigated by using supercritical carbon dioxide, the IPA co-solvent and cleaning additive chemicals. First, the solubility of several surfactants and binders in supercritical carbon dioxide solubility and particle dispersibility in the binders were evaluated in order to confirm their suitability for the supercritical cleaning process. Particle removal experiments were carried out with adjusting various process parameters and reaction conditions. The surfactants used in the experiment showed little particle removal effect, producing secondary contamination on the surface of wafers. On the other hand, 5 wt% (with respect to $scCO_2$) of the cleaning additive mixture of trimethyl phosphate, IPA, and trace HF resulted in 85% of particle removal efficiency after $scCO_2$ flowing for 4 minutes at $50^{\circ}C$, 2000 psi, and the flow rate of $15mL\;min^{-1}$.

Verification Experiment of a Ground Source Multi-heat Pump at Cooling Mode (지열원 물대공기 멀티 히트펌프의 냉방 운전 특성에 관한 실증 연구)

  • Choi, Jong-Min;Kang, Shin-Hyung;Choi, Jae-Ho;Lim, Hyo-Jae;Moon, Je-Myung;Kwon, Young-Seok;Kwon, Hyung-Jin;Kim, Rock-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.297-304
    • /
    • 2009
  • The aim of this study is to investigate the cooling performance of ground source multi-heat pump systems with a vertical single U-tube GLHX(U-tube system) and a vertical double tube GLHX(double tube system), which were installed in a school building located in Cheonan. All systems were operated in a part load conditions for all day, and the maximum COP of the single U-tube system and the double tube system were 6.2 and 5.2 at cooling mode, respectively. The double tube GLHX designed by the GLHEPRO, commercial program, was estimated to have the same performance as the U-tube GLHX, because the inlet temperatures of each outdoor unit heat exchanger for the former was similar to the latter. However, it is needed to prove the long tenn performance. It is suggested that the new algorithms to control the flow rate of secondary fluid for GLHX according to load variation have to be developed in order to enhance the performance of the system.

Preparation of Bismuth Vanadate Pigment from Aqueous Solutions (습식법에 의한 Bismuth Vanadate 안료의 제조)

  • Kim, Jung-Teag;Kim, Tae-Won;Heo, Jea-Jun;Na, Seog-Eun;Joo, Jung-Pyo;Chun, Jae-Ki;Ju, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.114-120
    • /
    • 2006
  • Bismuth vanadate is one of the environmentally benign substitutes for conventional inorganic pigments composed of heavy metals. The effect of process parameters on the physical properties of bismuth vanadate pigment prepared from aqueous solutions of potassium vanadate and bismuth nitrate were experimentally examined. Two aqueous solutions were fed into precipitation chamber at the same flow rate, and precipitates were formed at primary pH of 4.5 and secondary pH of 7.0~7.5. After aging for 3 hours in reaction mixture, 3 hours' calcination at $400^{\circ}C$ gave bismuth vanadate pigment with a good color and hiding power. Increase in molybdenum concentration in reaction mixture increased the hiding power of the pigment, but the other minor constituents had minor effect on the physical properties of the pigment.

Pressure Recovery in a supersonic ejector of a high altitude testing chamber (초음속 이젝터의 압력회복에 관한 연구)

  • Omollo, Owino George;Kong, Chang-Duk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.833-837
    • /
    • 2010
  • This study aims at finding an optimal exhaust diffuser design of a high altitude testing chamber for a low bypass turbofan engine (F404-402) with thrust pound force of 17,700 and air mass flow rate of 66kg/s ejecting at a speed of Mach 1.66. The final proposed ejector size has better pressure recovery characteristics and targets to reduce operational cost at engine performance testing. Conventional high altitude test chamber layout was adopted and first drawn in two dimensions using Autocad software so as to determine the gas path, the ejector frontal size was then determined from gas dynamics equations considering traditional gas ejection method where both the engine exhaust and cell cooling air are exhausted via the ejector. Modification to a smaller ejector with an alternative secondary cell cooling exhaust port was then performed and modelled in 3D using Solid Works software.

  • PDF

Modeling of Billet Shape in Spray Forming Process (분무성형공정에서의 빌렛형상 모델링)

  • Jang, Dong-Hun;Gang, Sin-Il;Lee, Eon-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.961-970
    • /
    • 1997
  • A numerical method is presented to predict and analyze the shape of a growing billet produced from the "spray forming process" which is a fairly new near-net shape manufacturing process. It is important to understand the mechanism of billet growing because one can obtain a billet with the desired final shape without secondary operations by accurate control of the billet shape, and it can also serve as a base for heat transfer and deformation analysis. The shape of a growing billet is determined by the flow rate of the alloy melt, the mode of nozzle scanning which is due to cam profile, the initial positio of the spray nozzle, scanning angle, and the withdrawal speed of the substrate. In the present study, a theoretical model is first established to predict the shape of the billet and next the effects of the most dominent processing conditions, such as withdrawal speed of the substrate and the cam profile, on the shape of the growing billet are studied. Process conditions are obtained to produce a billet with uniform diameter and flat top surface, and an ASP30 high speed steel billet is manufactured using the same process conditions established from the simulation.imulation.

Verification experiment of a ground source multi-heat pump at cooling mode (지열원 시스템 히트펌프의 냉방 성능 특성에 관한 실증 연구)

  • Lim, Hyo-Jae;Kang, Shin-Hyung;Choi, Jae-Ho;Choi, Jong-Min;Moon, Je-Myung;Kwon, Young-Seok;Kwon, Hyung-Jin;Kim, Rock-Hee
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.21-26
    • /
    • 2008
  • Recently, small and medium-sized buildings have employed a multi-heat pump. The major benefits of the multi-heat pump over a conventional system are that it is easier system to maintain along with a diversification of facility use, and high comfortability. The performance of multi-heat pump systems can be enhanced by using geothermal energy instead of air source energy. This paper describes the multi-heat pumps applied in an ground source heat pump system for an actual building. The performance of a ground source multi-heat pump installed in the field was investigated in cooling mode. The maximum COP of the systems with single U-tube and double tube ground loop heat exchangers were 6.6 and 6.0, respectively. It is suggested that the new algorithms to control the flow rate of secondary fluid for ground loop heat exchanger have to be developed in order to enhance the performance of the system.

  • PDF

Outcome of 980 nm diode laser vaporization for benign prostatic hyperplasia: A prospective study

  • Mithani, M. Hammad;El Khalid, Salman;Khan, Shariq Anis;Sharif, Imran;Awan, Adnan Siddiq;Mithani, Shoaib;Majeed, Irfan
    • Investigative and Clinical Urology
    • /
    • v.59 no.6
    • /
    • pp.392-398
    • /
    • 2018
  • Purpose: To evaluate the initial experience and outcome of photo-selective vaporization of the prostate (PVP) for benign prostatic hyperplasia (BPH) in Pakistan with the use of a 980 nm diode laser. Materials and Methods: A prospective study was performed from November 2016 to December 2017. A total of 100 patients diagnosed with bladder outlet obstruction secondary to BPH who planned for PVP were enrolled in the study. PVP was carried out with a diode laser at 980 nm (Biolitec Diode 180W laser) in a continuous wave with a 600 nm (twister) fiber. Baseline characteristics and perioperative data were compared. Postoperative outcomes were evaluated by International Prostate Symptom Score (IPSS), post void residual (PVR) and maximum urinary flow rate (Qmax) at 3 and 6 months after surgery. Results: The mean age was $65.82{\pm}10.42$, mean prostate size was $67.35{\pm}16.42$, operative time was $55.85{\pm}18.01$ and total energy was $198.68{\pm}49.12kJ$. At 3 months and 6 months, significant improvements were noted (p<0.001) in IPSS $7.04{\pm}1.69$ (-18.92), Qmax $19.22{\pm}4.75mL/s$ (+13.09) and and PVR $18.89{\pm}5.39mL$ (-112.80). Most frequent problems were burning micturition (35%) and terminal dysuria (29%). No significant difference in postoperative hemoglobin was seen in patients who were on anti-platelet drugs. Conclusions: PVP with a diode laser is a safe and effective procedure for the treatment of BPH and is also safe in patients who are on anti-platelet agents.

A three-region movable-boundary helical coil once-through steam generator model for dynamic simulation and controller design

  • Shifa Wu;Zehua Li;Pengfei Wang;G.H. Su;Jiashuang Wan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.460-474
    • /
    • 2023
  • A simple but accurate mathematical model is crucial for dynamic simulations and controller design of helical coil once-through steam generator (OTSG). This paper presents a three-region movable boundary dynamic model of the helical coil OTSG. Based on the secondary side fluid conditions, the OTSG is divided into subcooled region (two control volumes), two-phase region (two control volumes) and superheated region (three control volumes) with movable boiling boundaries between each region. The nonlinear dynamic model is derived based on mass, energy and momentum conservation equations. And the linear model is obtained by using the transfer function and state space transformation, which is a 37-order model of five input and three output. Validations are made under full-power steady-state condition and four transient conditions. Results show good agreements among the nonlinear model, linear model and the RELAP5 model, with acceptable errors. This model can be applied to dynamic simulations and controller design of helical coil OTSG with constant primary-side flow rate.