하수처리장 방류수 색도 제거에 관한 연구 (A Study on the Color Removal in the Secondary Effluent)

  • 이면주;정영도;진준하
    • 환경위생공학
    • /
    • 제13권3호
    • /
    • pp.30-36
    • /
    • 1998
  • A study on the color removal by irradiation of ${\gamma}-ray$ was carried out to reclaim the secondary effluent for the purpose of industrial water. Coagulation, ozone and ion exchange methods were compared. It could know that irradiation method was the most effective in color removal. The color was removed by 87.5% at 0.5 Mrad and it was increase with dose. High removal efficiency could be obtained in low pH and low concentration of $CO3^{-2}$. This process can be applied to the treatment of secondary effluent and is considered to be one of the most useful tertiary treatment.

  • PDF

BAF를 이용한 2차 처리수의 재이용 가능성 및 강우시 하수처리장 월류수의 처리 (Reuse Possibility of By-pass Flow and Secondary Effluent using BAF)

  • 안지훈;박종복;김성원;박재홍;하준수;최의소
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.190-195
    • /
    • 2005
  • The laboratory and pilot scale BAFs (biological aerated filters) were operated with 0.3 hr to 1.1 hr EBCT(empty bed contact time) at a maximum filtration rate of $472m^3/m^2/day$ as a treatment method for reuse of secondary effluent and by-pass flow in this study. The effluent BOD and SS were generally 3.5 to 5 mg/L and 2 to 3 mg/L, respectively with 2ndary effluent, but the SS concentrations increased to 4 to 8 mg/L with the increased flow rates of by-pass flow. Potential nitrification rates were very high, but the nitrogen removal efficiencies were low due to the limited carbon sources. Bypass of a part of primary effluent seemed to be desirable to increase the nitrogen removal. Disinfection must be furnished for the reuse of BAF effluent.

CFD와 PIV test를 통한 원형 2차침전지 유입 및 유출배플 형상 최적화 (Optimization of influent and effluent baffle configuration of circular secondary clarifier using CFD and PIV test)

  • 최영균;배강형
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.73-81
    • /
    • 2014
  • One-dimensional flux theory (1DFT) is conventionally used for design of secondary clarifier of wastewater treatment plant. However, the 1DFT cannot describe turbulence, density current, shape parameters of the clarifier. In this study, we optimized the configurations of influent guide baffle and effluent baffle through the simulation using computational fluid dynamics (CFD) and its verification by particle image velocity (PIV) test. The energy dissipating inlet (EDI) without influent guide baffle ($0^{\circ}$) showed the best efficiency for minimizing downward velocity under the center well of the clarifier. The lowest velocity distribution around the effluent weir region could be obtained with the McKinney baffle (EB-2). The performances of the influent and effluent baffles were clearly verified by PIV test results.

방류수 재이용을 위한 합성투과 여재 여과 (Synthetic Permeable Medium Filtration for Secondary Effluent Reclamation)

  • 박기영;맹승규;김기팔;권지향;윤현희;안규홍
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.3-7
    • /
    • 2005
  • In the present study a feasibility of a novel filtration process using synthetic for secondary effluent reclamation was investigated. Polyurethane was chosen as a filter medium among tested three media. Compressibility and up-flow velocity were changed to determine the optimum operation for the system. An equation was introduced to express the relationship between the removal efficiency and up-flow velocity. In pilot study, the synthetic medium filtration with compression showed very stable effluent quality without clogging trouble, though the system operated with 3 times higher filtration rate and much longer backwashing interval than conventional systems.

하수처리장 2차 처리수의 고효율 인 제거를 위한 응집제 개선 (Improved Coagulant for High Efficiency Phosphorus Removal in Secondary Effluent of Waste Water Treatment Plant)

  • 최정승;이병하;김기팔;백대진
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.683-690
    • /
    • 2016
  • Modified coagulants were investigated for the removal of phosphorus from secondary effluent of wastewater treatment. The modified coagulants were prepared by mixing alkali earth metal ions such as calcium and magnesium. The basicity of a coagulant influenced on the removal of phosphorus, and coagulants with basicity of 5.9% showed a better removal of total phosphorus than that of 38.5%. Also, coagulants with alkali earth metals enhanced the performance of coagulation by 10% and resulted in 67.1% for total phosphorus removal. Moreover, the removal of suspended solids and chemical oxygen demand was improved using coagulants with low basicity and earth metal ions. Results of this study demonstrated that the use of coagulants with low basicity, and calcium and magnesium ions is recommended to improve wastewater effluent quality.

DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구 (Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System)

  • 이병호;김상희
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

약품역세를 적용한 하수재이용 막여과 시스템의 운전성능 평가 (Evaluation of operating performance of secondary effluents treatment membrane system adapted chemical backwashing)

  • 김영훈;이창하;전민정;이용수;이의종;남종우;김형수
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.335-342
    • /
    • 2011
  • Secondary effluent contains particle compounds which are comprised of microorganisms that occurs membrane fouling when the water is reused. This study evaluates the characteristics of membrane fouling of secondary effluent reuse. Effects of chemical backwashing are analyzed to reduce membrane fouling by regular chemical backwashing. As the result, major membrane foulants are verified EPS materials which include protein and polysaccharide that cause biofilm cake layer on the membrane. Also, sodium hypochlorite is applied to chemical backwashing. The backwashing improves recover rate when injected chemical concentration is increased and chemical backwashing cycle is amplified. Chemical backwashing cycle affects more than injected chemical concentration yet idle time does not noticeably influence on reducing membrane fouling.

하수처리장 운전조건의 통계분석 (Statistical Analysis of Sewage Plant Operation)

  • 이찬형;문경숙
    • 한국환경과학회지
    • /
    • 제11권1호
    • /
    • pp.63-68
    • /
    • 2002
  • In this study, we examined statistical analysis between sewage plant operations parameters and effluent quality We got six components from principle component analysis of the operation parameters and secondary effluent quality. 91.8% of the total variance was explained by the six components. The components were identified in the following order : 1) organic matter removal by aeration basin microbe, 2) settleability on secondary clarifier load, 3) removal of nutrients, 4) microbial number increasement and species diversity, 5) microbial activity in aeration basin, 6) oxidation in aeration basin.

갈대 및 부들 습지셀의 연못시스템 방류수 질소제거 비교 (Comparison of Nitrogen Removal Between Reed and Cattail Wetland Cells in a Treatment Pond System)

  • 양홍모
    • 한국환경농학회지
    • /
    • 제23권4호
    • /
    • pp.234-239
    • /
    • 2004
  • [ $NO_3$ ]-N and T-N removal rates of cattail wetland cells were compared with those of reed wetland cells. The examined cells were a part of a pond-wetland system composed of two ponds in series and six wetland cells in parallel. Each wetland cell was 25m in length and 6m in width. Cattails (Typha angustifolia) were transplanted into three cells and reeds Phragmites australis) into another three ones in June 2000. Water of Sinyang stream flowing into Kohung Estuarine lake located in the southern part of the Korean Peninsula was pumped into the primary pond, its effluent was discharged into the secondary pond Effluent from the secondary pond was funneled into each cell. Two cattail and reed cells were chosen for this research. Water quantity and quality of influnt and effluent were analyzed front May 2001 through October 2001. The volume of influent and effluent of the cells averaged about $20.0\;m^3/day$ and $19.3\;m^3/day$, respectively. Hydraulic retention time was approximately 1.5 days. Influent $NO_3$-N concentration for the four cells averaged 2.39 mg/L. Effluent $NO_3$-N concentration far the cattail and reed cells averaged 1.74 and 1.78 mg/L, respectively. Average $NO_3$-N retention rate for the cattail and reed cells by mass was 30 and 29%, respectively. Influent T-N concentration far the four cells averaged 4.13 mg/L. Effluent T-N concentration for the cattail and reed cells averaged 2.55 and 2.61 mgL respectively. Average T-N retention rate for the cattail and reed cells by mass was 39 and 38%, respectively. $NO_3$-N and T-N concentrations in effluent from the cattail cells were significantly low (p=0.04), compared with those from the reed cells. Cattail wetland cells were more efficient for $NO_3$-N and T-N abatement than reed ones.

하수 2차 처리수 재이용을 위한 hybrid 응집-UF 막분리 공정의 적용 (Application of Coagulation-UF Hybrid Membrane Process for Reuse of Secondary Effluent)

  • 이철우;손정기;손인식;한승우;강임석
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.605-612
    • /
    • 2005
  • The objective of this study was to evaluate the factors affecting the optimization of coagulation hybrid UF membrane processes for the reuse of secondary effluent from sewage treatment plant. The experimental results obtained from the UF membrane process showed that organic colloids in the size range of $0.2{\mu}m{\sim}1.0{\mu}m$ caused the most substantial influence on the fouling of UF membrane. When using a coagulation pretreatment to UF membrane, alum dosage of 50mg/L resulted in the least reduction in membrane permeate flux. Also, for the rapid mixing process, in-line mixer type was more efficient for organic removal than back mixer type. Therefore, it may be concluded that coagulation-UF hybrid membrane process comparing to UF alone process showed not only higher removal efficiency of organic matter, but also substantial improvement of permeate flux of UF membrane.